Commercial Skylites
|
|
|
|
|
|
|
|
|
|
Model CM
|
.060” T6063 extruded aluminum frame and retaining angle with integral condensation gutter and weep holes to direct moisture to the exterior.
|
|
|
|
|
|
|
|
Model TCM
|
.060” T6063 thermally broken extruded aluminum frame and retaining angle with integral condensation gutter to help reduce interior moisture.
|
|
|
|
|
|
|
|
Model SF
|
3.25" , 5.25" , 9”, 12”
|
|
|
|
|
|
|
|
Model ISF
|
9”, 12” . T6063 .032” extruded aluminum inner and outer curb wall with 1” fiberglass insulation and .060” curb frame.
|
|
|
|
|
|
|
|
Model TSF
|
4”, 9”, 12”. T6063 thermally broken extruded aluminum curb wall and curb frame. 4” curb wall and frame is .070”, 9”/12” are .032” inner and outer curb wall with .060” curb frame.
|
|
|
|
|
|
|
|
Model EZISF
|
9”, 12”, All units have ¾” polyisocyanurate insulated curb walls, 1 X 4 wood nailer, 3” installation flange for EZ installation, integral condensation gutter, and weep holes to direct any moisture to the exterior.
|
|
|
|
|
|
|
|
Model EZSF
|
9”, 12”. All units have 1 X 4 wood nailer, 3” installation flange for EZ installation, integral condensation gutter, and weep holes to direct any moisture to the exterior.
|
|
|
|
|
|
Residential Skylites
|
|
|
|
|
|
|
|
|
|
Model CM
|
Standard colors are available in Acrylic, Polycarbonate and Multiwall Polycarbonate Sheet. Custom colors upon request.
|
|
|
|
|
|
|
|
Model TCM
|
Finish: Mill, Bronze Anodized, Clear Anodized, or White. Many anodized and custom finishes are available upon request.
|
|
|
|
|
|
|
|
Model SF-LP, SF-HP
|
3.25", 5.25". T6063 extruded aluminum frame and retaining angle. 3.25"/5.25" are .060”/.090” curb wall and curb frame.
|
|
|
|
|
|
|
|
Model TSF
|
4" . T6063 .070” thermally broken extruded aluminum curb wall and curb frame.
|
|
|
|
|
|
|
|
Model GTCM
|
Thermally broken aluminum frame construction with condensation gutter to help reduce interior moisture and create a more energy efficient skylight. Unit mounts to roof curb built by installer.
|
|
|
|
|
|
|
|
Model GTSF
|
Thermally broken aluminum frame construction 1” insulated frame and condensation gutter to help reduce interior moisture and create a more energy efficient skylight. Unit mounts directly to roof deck for easy installation.
|
|
|
|
|
|
|
|
Model GTVCM & GTVSF
|
Operable thermally broken aluminum frame construction with 1” insulated frame and condensation gutter to help reduce interior moisture and create a more energy efficient skylight. All operable units include an insect screen. Unit mounts directly to roof curb or roof deck for easy installation.
|
|
|
|
|
|
|
|
Model TVCM & TVSF
|
Operable thermally broken aluminum frame construction with 1” insulated frame and condensation gutter to help reduce interior moisture and create a more energy efficient skylight. All operable units include an insect screen. Unit mounts directly to roof curb or roof deck for easy installation.
|
|
|
|
|
|
Roof Systems
|
|
|
|
|
|
|
|
|
|
Model BV
|
All non-structural roof systems are made to size specifications supplied to American Skylites. Roof systems, as all American Skylites, are available with unlimited options from glazing and finish color to bay sizing and configuration.
|
|
|
|
|
|
|
|
Model HR
|
Roof systems, as all American Skylites, are available with unlimited options from glazing and finish color to bay sizing and configuration.
|
|
|
|
|
|
|
|
Model RM
|
Roof systems, as all American Skylites, are available with unlimited options from glazing and finish color to bay sizing and configuration. We make it easy to fit any opening whether it be for new construction or a replacement for an existing opening.
|
|
|
|
|
|
|
|
Model RL
|
All non-structural roof systems are made to size specifications supplied to American Skylites.
|
|
|
|
|
|
|
|
Model GS, Model TS
|
.060” T6063 extruded aluminum frame and .125” T6063 extruded aluminum retaining angle with integral condensation gutter and weep holes to direct moisture to the exterior. Unit mounts to roof curb by others. Available with options.
|
|
|
|
|
|
Fall Protection
|
|
|
|
|
|
|
|
|
|
Model TCM-FG
|
American Skylites manufactures skylights to meet OSHA guidelines for fall protection. OSHA guidelines specify that upon impact of a 200 lb. load dropped into mid-span of the domed skylight, no glazing disengagement or breakage of glazing material at a minimum force of 775 ft/lbs. will occur.
|
|
|
|
|
|
|
|
Model TSF-9-FG
|
American Skylites manufactures skylights to meet OSHA guidelines for fall protection. OSHA guidelines specify that upon impact of a 200 lb. load dropped into mid-span of the domed skylight, no glazing disengagement or breakage of glazing material at a minimum force of 775 ft/lbs. will occur.
|
|
|
|
|
|
|
|
Model TSF-12-FG
|
American Skylites manufactures skylights to meet OSHA guidelines for fall protection. OSHA guidelines specify that upon impact of a 200 lb. load dropped into mid-span of the domed skylight, no glazing disengagement or breakage of glazing material at a minimum force of 775 ft/lbs. will occur.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|