MasterFormat: 95
SpecWizard: customize this spec    Download this Glass Floor System Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Innovative Building Products, Inc. Glass Floor System
 
         
SECTION 04818
 
         
GLASS FLOOR SYSTEMS
 
         
Copyright 2005 - 2011 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Innovative Building Products, Inc., a Berkshire Hathaway company; IBP Glass Block Grid and GlassWalk SG Systems.
.
This section is based on the "IBP Glass Block Grid and the GlassWalk(tm) SG Systems" manufactured by Innovative Building Products, Inc., which is located at:
          3024 Acme Brick Plaza
Fort Worth, TX 76109
Phone Toll Free: (800) 932-2263
Phone: (817) 332-4101
Fax: (817) 332-1406
Email: info@ibpglassblock.com
Web Site: www.ibpglassblock.com
[click Here] for additional information.
          The IBP Glass Paver Grid System allows you open up an area to pedestrian traffic without creating "dead space" below. Light passes through an IBP floor, so more natural light reaches the space underneath an important consideration for walkways and the colorful underfloor lighting can create a striking effect.
The IBP Glass Paver Grid System sets real glass block in a precision engineered, custom-manufactured aluminum grid that allows both for building movement and for expansion/contraction of glass block and surrounding materials.
IBP now offers a floor system engineered for the next generation in structural glass: laminated units 1 inch thick. The heart of the GlassWalk™ structural glass floor system is the modular IBP aluminum frame. For most installations, IBP supplies two-ply laminated glass units: a top layer tempered for impact resistance and a heat-strengthened bottom layer, bonded with a clear resin interlayer. GlassWalk(tm) SG system is rated for glass units up to a 48 inches clear span with a 48 inches width (a full 16 SF area) or up to a 89 inches clear span in a 5 inch width.


 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Glass paver floor system, consisting of structural extruded aluminum grid and glass pavers, and all other items necessary for a complete assembly.
 
          B.Structural glass floor system, consisting of structural extruded aluminum grid and laminated structural glass units, and all other items necessary for a complete assembly.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 03300 - Cast-in-Place Concrete: Concrete structure and slabs.
 
          B.Section05100 - Structural Steel: Support Structure and Containment Rings.
 
          C.Section 06110 - Rough Carpentry: Wood Frame Support Structure.
 
          D.Section 07900 - Joint Sealers: Sealant installation requirements.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes.
 
          B.ASTM D 2000 - Standard Classification System for Rubber Products in Automotive Applications
 
          1.4SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Installation methods.
 
          C.Shop Drawings: Show plan, sections, details, location and spacing of anchors, and relationship to adjoining work.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          D.Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
 
          E.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
 
          1.5DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging until ready for installation.
 
          B.Store materials in dry place, off the ground, where temperature will not exceed 90 degrees F (32 degrees C).
 
          C.Handle material in manner that will prevent damage to finished surfaces. Do not install scratched or damaged components.
 
          1.6PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          1.7WARRANTY
 
          A.Provide manufacturer's standard 5-year warranty.
 
          B.Provide 5-year installer's warranty against faulty workmanship.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Innovative Building Products, Inc., IBP GlassWalk Floor System, (a Berkshire Hathaway company) 3024 Acme Brick Plaza; Ft. Worth, TX 76109; Toll Free Tel: (800) 932-2263; Tel: (817) 332-4101; Fax: (817) 332-1406; Email: info@ibpglassblock.com Web Site: www.glasswalkfloors.com or www.ibpglassblock.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
          ** NOTE TO SPECIFIER ** Select the materials required from the following paragraphs. Delete the paragraphs not required.
 
          2.2MATERIALS - GLASS PAVER FLOOR SYSTEM
 
          A.Glass Paver Support Grid: Field assembled, extruded aluminum two-way hollow structural grid, sized to fit glass pavers with one paver to a module, and perimeter frame.
          1.Finish:
          ** NOTE TO SPECIFIER ** Select the color required from the following paragraphs. Delete the paragraph not required.
          a.Clear anodized, matt silver finish.
          b.Custom color as selected.
 
          B.Glass Pavers: Solid glass units, Size, color and pattern as follows:
          ** NOTE TO SPECIFIER ** Select the size required from the following paragraphs. Delete the paragraph not required.
          1.Size: Nominal 6 inch (152 mm) by 6 inch (152 mm) by 1 inch (25 mm) thick.
          ** NOTE TO SPECIFIER ** Select the color and pattern required from the following paragraphs. Delete the paragraphs not required.
          a.Color and pattern:
          1)As selected from manufacturers standard range.
          2)Clearview
          3)Daisy Button
          4)Delphi
          5)Clearview Sand Blasted
          6)Daisy Button Sandblasted
          7)Delphi Sandblasted.
          2.Size: Nominal 8 inch (203 mm) by 8 inch (203 mm) by 1 inch (22 mm) thick.
          ** NOTE TO SPECIFIER ** Select the color and pattern required from the following paragraphs. Delete the paragraph not required.
          a.Color and pattern:
          1)As selected from manufacturers standard range.
          2)Color and pattern: Concentric Circle Pattern.
          3)Color and pattern: Concentric Circle Pattern, Sand Blasted.
 
          C.Paver Boots: Molded EPDM sleeve and setting accessory conforming to ASTM D2000.
 
          D.Sealant: Dow Corning Corp. "799" sealant.
 
          E.Accessories: Provide all sealants, flashings, anchors, fasteners, and other items necessary for complete installation.
          ** NOTE TO SPECIFIER ** Select the materials required from the following paragraphs. Delete the paragraphs not required.
 
          2.3MATERIALS - STRUCTURAL GLASS FLOOR SYSTEM
 
          A.Glass Floor Support Grid: Field assembled, extruded aluminum two-way hollow structural grid, sized to fit glass floor unit with one unit to a module, and perimeter frame.
          1.Finish:
          ** NOTE TO SPECIFIER ** Select the color required from the following paragraphs. Delete the paragraph not required.
          a.Clear anodized, matt silver finish.
          b.Custom color as selected.
 
          B.Laminated Glass Floor Units: Laminated glass units, nominally 1 inch thick with a top layer tempered for impact resistance and a heat strengthened bottom layer bonded with a clear resin interlayer. Size, color and pattern as follows:
          ** NOTE TO SPECIFIER ** GlassWalk SG system is available in glass units up to a 48 inches clear span with a 48 inches width (16 SF area) or up to a 89 inches clear span in a 5 inch width. Coordinate the actual size and load requirement with the manufacturer. Select or edit the size required from the following paragraphs. Delete the paragraphs not required.
          1.Size:
          a.Nominal 48 inch (1219 mm) by 48 inch (1219 mm) by 1 inch (25 mm) thick.
          b.Nominal 89 inch (2261 mm) by 5 inch (127 mm) by 1 inch (25 mm) thick.
          c.Nominal size as indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Select the color and pattern required from the following paragraphs. Delete the paragraphs not required.
          2.Color and finish:
          a.Color:
          ** NOTE TO SPECIFIER ** Select the color required and delete the paragraph not required.
          1)Clear Glass.
          2)Obscurity pattern.
          b.Type:
          ** NOTE TO SPECIFIER ** Select the type required and delete the paragraph not required.
          1)Standard.
          2)Low Iron Glass.
          c.Finish:
          ** NOTE TO SPECIFIER ** Select the finish required and delete the paragraphs not required.
          1)Non slip, Traction Control, ceramic frit pattern, Circle Dot.
          2)Non slip, Traction Control ceramic frit pattern, Mezzo.
          3)Non slip, Traction Control, ceramic frit pattern, Horizontal Perforation.
          4)Non slip, Traction Control, ceramic frit pattern, Boiler Plate.
          5)Non slip, Traction Control, ceramic frit pattern, Custom as selected by the Architect.
 
          C.Cushions: Extruded silicone.
 
          D.Sealant: Dow Corning Corp. "799" sealant.
 
          E.Accessories: Provide all sealants, flashings, anchors, fasteners, and other items necessary for complete installation.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until supporting structure has been properly prepared.
 
          B.If structure is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
 
          B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result under the project conditions.
 
          3.3INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
          ** NOTE TO SPECIFIER ** The following 7 paragraphs refer to the glass paver system edit as required or delete if not required.
 
          B.Assemble glass block grid floor system according to instructions furnished by manufacturer into prepared supporting structure containment ring.
 
          C.Set grid frame so that top surface of grid and pavers is flush with adjoining floor surfaces, unless otherwise indicated.
 
          D.Insert paver units into paver boots and set in grid modules.
 
          E.Install sealant in accordance with the sealant manufacturers printed instructions.
 
          F.Apply sealant around exterior face of glass pavers completely filling channel. Tool sealant flush with surface.
 
          G.Seal joints between grid members.
 
          H.Apply sealant between perimeter frame and adjoining construction.
          ** NOTE TO SPECIFIER ** The following 6 paragraphs refer to the structural glass floor system edit as required or delete if not required.
 
          I.Assemble floor system according to instructions furnished by manufacturer into prepared supporting structure containment ring.
 
          J.Set grid frame so that top surface of grid and glass units is flush with adjoining floor surfaces, unless otherwise indicated.
 
          K.Insert structural glass units on silicone cushions and set in grid members.
 
          L.Install sealant in accordance with the sealant manufacturers printed instructions.
 
          M.Apply sealant to completely fill channel around each glass unit and joints between aluminum grid members and wipe flush with top surface.
 
          N.Apply sealant between perimeter frame and adjoining construction.
 
          3.4CLEANING
 
          A.Clean exposed surfaces of aluminum grid with clean, soft cloth and mild hand soap using gentle rubbing action. Do not use abrasive or solvent type cleaners, detergents, or paint removers.
 
          B.Remove labels from glass pavers and clean with soft cloth and water.
 
          3.5PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
 
         
END OF SECTION