MasterFormat: 95
SpecWizard: customize this spec    Download this Concrete Roof Tile Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
MonierLifetile Concrete Roof Tile
 
         
SECTION 07321
 
         
CONCRETE ROOF TILE
 
         
          ** NOTE TO SPECIFIER ** MonierLifetile; Standard weight and light weight concrete roof tile.
.
This section is based on the products of MonierLifetile, which is located at:
7575 Irvine Center Dr. Suite 100
Irvine, CA 92618
Toll Free Tel: 800-571-TILE (8453)
Tel: 949-756-1605
Fax: 949-756-2401
Email: request info
Web: www.monierlifetile.com
[ Click Here ] for additional information.

MonierLifetile(tm) was formed in 1997 as a joint venture between long-time industry leaders Monier Inc. and Boral Lifetile 1nc. Monier was founded in 1965 and Lifetile in 1962. The company is the largest manufacturer of premium-quality roof tile in the United States. MonierLifetile(tm) offers a broad selection of concrete roof tile and Roof System Components for both new construction and reroof. MonierLifetile is committed to providing our customers with a tile roof, not just roof tile. The underlying foundation for a tile roof is just as vital as the tile that completes it. Our goal is to provide an optimal roof installation by offering tile and component products that make such an installation possible. When used together, MonierLifetile roof tile and Roof System Components can provide a long-lasting and better performing tile roof.

For tile profiles (shapes), the specifier should review the manufacturer's literature or website. Colors should be verified based on the plant where the tile will be made.

The relevant building codes covering tile installations are:
South Florida Building Code (SFBC): Chapter 23 & 34.
Standard Building Code (SBC): Chapter 12 & 32; 1996.
Uniform Building Code (UBC): Chapter 15 & Appendix; 1997.
.

 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Concrete roof tiles and roof system components.
 
          B.Metal roof flashing.
 
          C.Underlayments and self seal membrane.
 
          D.Related roof accessories.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 06100 - Rough Carpentry; Roof sheathing and nailers.
 
          B.Section 07220 - Roof and Deck Insulation.
 
          C.Section 07600 - Flashing and Sheet Metal.
 
          D.Section 07710 - Roof Specialties; Roof gutters and downspouts.
 
          E.Section 07720 - Roof Accessories.
 
          F.Section 08600 - Skylights.
 
          G.Division 15 - Mechanical: Mechanical work projecting through roof.
 
          H.Division 16: - Electrical: Electrical work projecting through roof.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ASTM A 90 - Standard Test Method for Weight (Mass) of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings; 2001.
 
          B.ASTM A 525 - Standard Specification for General Requirements for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process; 1993.
 
          C.ASTM A 641 - Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire; 1998.
 
          D.ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
 
          E.ASTM C 1492 - Standard Specification for Concrete Roof Tile.
 
          F.ASTM D 226 - Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing; 1997a.
 
          G.ASTM D 249 - Standard Specification for Asphalt Roll Roofing (Organic Felt) Surfaced with Mineral Granules; 1989 (reapproved 1996).
 
          H.ASTM D 2626 - Standard Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet Used in Roofing; 1997b.
 
          I.AWPA C2 - Lumber, Timber, Bridge Ties and Mine Ties -- Preservative Treatment by Pressure Processes; 2001.
 
          J.Tile Roofing Institute (TRI) - Standard Installation Guides for Concrete and Clay Roof Tile in Cold Weather Applications. 1998
 
          K.FRSA/TRI - Concrete and Clay Roof Tile Installation Manual Second Edition (For Florida High Wind Applications, 125 mph). January 1998.
 
          L.ICC ER 2656 (ICBO-ES) - International Code Council Evaluation Services.
 
          M.ICBO ER-6034P Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions
 
          N.International Code Council Evaluation Services - ICC ES 9460C (SBCCI-ES)
 
          O.ICC AC 180 - Acceptance Criteria for Clay and Concrete Roof Tiles. September, 2002.
 
          P.Florida Building Code, Product Approval - FL 560
 
          Q.City of Los Angles Research Report - LA RR 23700
 
          R.CAN/CSA-A220.1-M91 - Installation of Concrete Roof Tiles.
          ** NOTE TO SPECIFIER ** Roofing tiles conform to the requirements as listed in the following paragraphs. Edit as required for the roof tile selected and the project conditions. Consult with manufacturer for additional information.
 
          1.4DESIGN REQUIREMENTS
          ** NOTE TO SPECIFIER ** The following paragraph applies to MonierLifetile, Roma, Classic "100," Homestead, Mission "S," Shake, Slate, Split Shake, Duralite Shake, Duralite Slate, Split Slate, Country Shake, Country Slate, Country Split Shake, Country Split Slate, Cedarlite, Colonial Slate, Shingle Blend, Sierra Shake, Super Shake, Atlantis Shake and Slate, Espana, Espana Tejas, Capri, Villa, Duralite Villa, Vanguard Roll, Bermuda, Mission Barrel, Spanish "S", Sentry Classic and Traditions. Roofing tiles. Edit as required for the project conditions. Consult with manufacturer for additional information.
 
          A.Roofing tile materials and installation shall conform to the requirements of ICC ER 2656, ICC ER 9460C and LA RR 23700.
          ** NOTE TO SPECIFIER ** The following paragraph applies to MonierLifetile Concrete Roof Tile products as listed. Edit as required for the project conditions and the tile specified in Part 2 of this specification. Delete the listing and products that are not applicable. Consult with manufacturer for additional information if required.
 
          B.Roofing tile materials and installation shall conform to the requirements of Miami Dade County Notice of Acceptance (NOA) as follows:
          1.NOA 02-0328.04 - Duralite Shake & Slate.
          2.NOA 02-0328.05 - Duralite Villa.
          3.NOA 02-1205.04 - Mission "S", Espana.
          4.NOA 02-1205.05 - Villa, Vanguard Roll, Capri.
          5.NOA 02-1205.06 - Flat Shake & Slate, Sierra Shake, Super Shake, Colonial Slate & Shingle Blend.
          6.NOA 02-1205.07 - Spanish "S".
          7.NOA 02-1211.06 - Cedarlite.
          8.NOA 02-1211.07 - Mission Barrel.
          9.NOA 02-1211.08 - Atlantis Shake & Slate.
          10.NOA 04-0512.04 - MonierLifetile Madera.
          ** NOTE TO SPECIFIER ** The following paragraph applies to the following: Regular Weight MonierLifetile: Villa, Mission S, Classic 100, Shake and Slate, Vanguard Roll Tile, Spanish S, Bermuda, Mission Barrel, Espana, Capri, Colonial Slate, Shingle Blend, Sierra Shake, Super Shake, Atlantis Shake and Slate Concrete Roofing Tiles. Also applies to Lightweight MonierLifetile: Premium Duralite Villa, Premium Duralite Shake and Slate and Cedarlight Concrete Roofing Tiles. Edit as required for the project conditions. Consult with manufacturer for additional information.
 
          C.Roofing tile materials and installation shall conform to the SBCCI Standard for Hurricane Resistant Residential Construction, SSTD10-99, the International Building Code for One and Two Family Dwelling Code and the Florida Building Code 2001.
 
          D.Roofing tile materials and installation shall conform to the requirements of the applicable building code.
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.[ Product Data ]: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Installation methods.
 
          C.Shop Drawings: Indicate metal flashing profiles, joint locations, fastening locations, and installation details. Indicate tile layout with location of cut and special shaped tiles identified.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected in the specification.
 
          D.Selection Samples: For each finish product specified, two complete sets of tile colors representing manufacturer's full range of available colors and patterns.
 
          E.Verification Samples: For each finish product specified, two full size samples representing actual product, color, and patterns.
 
          F.Certificates of Compliance: Submit to certify compliance with referenced standards.
 
          1.6QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: Minimum five years documented experience producing concrete roof tile and member of National Tile Roofing Manufacturer's Association.
 
          B.Installer Qualifications: Minimum five years documented experience installing products specified in this section and/or supervision by a manufacturers authorized installation representative.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          C.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Mock-up shall be a minimum of a 10 foot (3.05 M) by 10 foot (3.05 M) area and include the edge, ridge, valley and other typical transition conditions anticipated.
          3.Do not proceed with remaining work until installation workmanship and appearance is approved by Architect.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          4.Mock-up may not remain as part of Work.
          5.Accepted mock-up may remain as part of Work.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging until ready for installation.
 
          B.Deliver products to project site in manufacturer's unopened pallets, labeled with data indicating compliance with specified requirements.
 
          C.Maintain dry storage area for products of this section until installation of products.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          B.Do not overload the roof. Distribute stacks of tile uniformly on roof at not greater than 12 inches (305 mm) in height.
 
          1.9WARRANTY
 
          A.Roof Tile: MonierLifetile's Limited Lifetime, Fully Transferable, Non-Prorated Product Warranty against defects in roof tile for the life of the structure.
          ** NOTE TO SPECIFIER ** Include the following if required for project. Verify that the installer will offer this warrantee in the location of the project. Delete if not required.
 
          B.Installation Warranty: Warrants products of this section, as installed, to be in accord with the Contract Documents and free from faults and defects in materials and workmanship for a period of 3 years after completion.
          ** NOTE TO SPECIFIER ** Include the following if required for project. Delete if not required.
 
          1.10EXTRA MATERIALS
 
          A.Provide an additional 1 percent of installed roof tiles, but not less than one full square, for Owner's use in roof maintenance.
 
          B.Furnish extra materials packaged with protective covering for storage and identified with labels clearly describing contents.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: MonierLifetile, which is located at: 7575 Irvine Center Dr. Suite 100 ; Irvine, CA 92618; Toll Free Tel: 800-571-TILE (8453); Tel: 949-756-1605; Fax: 949-756-2401; Email: request info; Web: www.monierlifetile.com
          ** NOTE TO SPECIFIER ** Select paragraph(s) representing the manufacturing and distribution center for the product specified and delete the others. Please note that each plant manufactures a different selection of profiles and colors and although any profile/color is available anywhere in the U.S., appropriate shipping costs will apply. Refer to tile profiles for plant(s) in the region of the projects location.
 
          B.Manufacturing and Distribution Facility:
          1.Arizona Region:
          a.Phoenix Plant, 1832 S. 51st Avenue, Phoenix, AZ 85043. Te1: 603-269-2288, Toll Free: 800-845-9921.
          2.Florida Region:
          a.Pompano Beach Plant, 1369 Hammondville Road, Pompano Beach, FL 33069. Tel: 954-786-5380, Toll Free: 800-818-0974;
          b.Boca Raton Plant, 135 N.W. 20th Street, Boca Raton, FL 33431. Tel: 561-338-8200, Toll Free: 800-585-8453;
          c.Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405, Toll Free: 800-282-3633.
          3.Hawaii Region:
          a.Hawaii, Hawaii Docks, Tacoma Plant, 10920 Steele Street Lakewood WA 98499. Tel: 800-699-8453.
          4.Heartland Region:
          a.Kansas City Plant, 12600 E. 98th Street, Kansas City, MO 64138. Tel: 861-767-3267, Toll Free: 866-204-8426.
          5.Northeast Region:
          a.Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405, Toll Free: 800-282-3633.
          6.Northern California Region:
          a.Gilroy Plant, 6500 Brem Lane, Gilroy, CA 95020. Tel: 408-847-2721. Tel: 800-841-5044.
          b.Lathrop Plant, 642 Roth Road, Lathrop, CA 95330. Te1: 209-983-1600. Tel: 800-669-8453.
          c.Stockton Plant, 9508 South Harlan, French Camp, CA 95231, Mailing: PO Box 6037, Stockton, CA 95206. Te1: 209-982-1473. Tel: 800-669-8453.
          d.Satellite Yard, 151 Roth Road, Lathrop, CA 95330. Tel: 800-669-8453.
          7.Pacific Northwest Region:
          a.Tacoma Plant, 10920 S. Steele St., Lakewood, WA 98499. Te1: 253-581-3666, Toll Free Te1: 800-451-0500.
          8.Rocky Mountain Region:
          a.Denver Plant, 10121 Dallas Street, Henderson, CO 80640. Tel: 303-286-3856.
          9.Southeast Region:
          a.Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405, Toll Free: 800-282-3633.
          10.Southern California Region:
          a.Rialto Plant: 3511 North Riverside Avenue, Rialto, CA 92377. Te1: 909-822-4407. Te1: 800-769-8453.
          11.Southern Nevada Region:
          a.Henderson Plant, 430 Eastgate, Henderson, NV 95020. Tel: 702-564-8453, Toll Free: 800-224-3560.
          12.Texas Region:
          a.Katy Plant, 30595 FM 529, Brookside, TX 77434. Te1: 281-371-2634, Toll Free: 866-204-8426.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          C.Substitutions: Not permitted.
 
          D.Requests for substitutions will be considered in accordance with provisions of Section 01600.
          ** NOTE TO SPECIFIER ** The following Concrete Roof Tile and Accessory Materials paragraphs represent the Manufacturing and Distribution locations for each MonierLifetile Region. Select the Region(s) representing the project location and delete those that are not applicable. Edit the products listed to suit the project requirements.

** NOTE TO SPECIFIER ** The following paragraphs represents the standard weight tile, lightweight tile and accessory materials available in MonierLifetile's Arizona Region, Phoenix Plant, 1832 S. 51st Avenue, Phoenix, AZ 85043. Tel: 603-269-2288 and 800-845-9921. Select the Weight and the Profile required and delete those not required.
 
          2.2CONCRETE ROOF TILE - ARIZONA
          ** NOTE TO SPECIFIER ** Standard weight tiles weigh 600 lbs/square or more. Delete all but one of the following tile profiles. If more than one is required, be sure to indicate where each is to be used on the drawings or the specifications.
 
          A.Standard Weight Tile: Mission "S" profile.
          1.Finishing Tile: Provide manufacturer's Capri Trim, Hip Starter and Capri Apex 3-Way tiles.
          2.Size: 16-1/2 inches (419 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 90 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 850 lbs (386 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Refer to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
 
          B.Standard Weight Tile: Boosted Barcelona profile.
          ** NOTE TO SPECIFIER ** Boosted Barcelona is an application of Barcelona which, when added to Barcelona field tile, creates the appearance of a mortar-boosted tile.
          1.Size: 13-1/2 inches (323 mm) by 6-1/2 inches (165 mm), nominal.
          2.Coverage: 10 percent application, 20 percent application, 30 percent application.
          3.Installed weight per square including field tile: 10 percent application, 936 lbs (425 kg), 20 percent application, 972 lbs (441 kg), 30 percent application, 1,008 lbs (457 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          4.Color and Finish: ________________.
          5.Color and Finish: As selected by the Architect.
 
          C.Standard Weight Tile: Saxony Slate profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4-Way tiles.
          2.Size: 16-1/2 inches (419 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 88 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 950 lbs (431 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
 
          D.Standard Weight Tile: Saxony Shake profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4-Way tiles.
          2.Size: 16-1/2 inches (419 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 88 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 950 lbs (431 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
 
          E.Standard Weight Tile: MonierLifetile Madera profile.
          1.Finishing Tile: Provide manufacturer's Rake, Hip/Ridge and Tapered Eave Starter tiles.
          2.Size: 13-1/2 inches (323 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 120 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 935 lbs (424 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** Lightweight tiles weigh no more than 600 lbs/square and are not recommended for use in areas with severe winter weather. Refer to the Manufacturer's map for locations where Lightweight products are recommended.
 
          F.Lightweight Tile: Cedarlite profile.
          1.Finishing Tile: Provide manufacturer's Rake, Hip/Ridge and Tapered Eave Starter tiles.
          2.Size: 13-1/2 inches (323 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 120 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 580 lbs (263 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
 
          G.Lightweight Tile: Duralite Barcelona profile.
          1.Finishing Tile: Provide manufacturer's Capri Trim, Hip Starter Capri and Apex 3-Way tiles.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 89 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 590 lbs (268 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Northern California Plant: Satellite Yard, 151 Roth Road, Lathrop, CA 95330. Tel: 800-669-8453. Select the Weight and the Profile required and delete those not required.
 
          H.Lightweight Tile: Duralite Villa profile.
          1.Finishing Tile: Provide manufacturer's Capri Trim, Hip Starter Capri and Apex 3-Way tiles.
          2.Size: 17 inches (432 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 87 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 590 lbs (263 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Northern California Gilroy Plant, 6500 Brem Lane, Gilroy, CA 95020. Te1: 408-847-2721 and 800-841-5044. Select the Weight and the Profile required and delete those not required.
 
          I.Lightweight Tile: Duralite Saxony Shake profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4-Way tiles.
          2.Size: 17 inches (432 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 85 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 596 lbs (270 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Northern California Gilroy Plant, 6500 Brem Lane, Gilroy, CA 95020. Tel: 408-847-2721 and 800-841-5044. Select the Weight and the Profile required and delete those not required.
 
          J.Lightweight Tile: Duralite Saxony Split Shake profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4-Way tiles.
          2.Size: 17 inches (432 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 85 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 596 lbs (270 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Northern California Gilroy Plant, 6500 Brem Lane, Gilroy, CA 95020. Tel: 408-847-2721 and 800-841-5044. Select the Weight and the Profile required and delete those not required.
 
          K.Lightweight Tile: Duralite Saxony Slate profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4-Way tiles.
          2.Size: 17 inches (432 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 85 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 596 lbs (270 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          NOTE TO SPECIFIER: MonierLifetile offers a complete line of Roof System Components that are recommended to ensure an optimal roof installation. Select the Accessory Material items which are appropriate for the project and the system selected. Consult with the manufacturer for additional information on Roof System Components.
 
          2.3ACCESSORY MATERIALS - ARIZONA
          ** NOTE TO SPECIFIER ** Select the required underlayment from the following paragraphs and delete paragraphs not relevant to this project.
 
          A.Underlayment:
          1.Type No. 30, complying with ASTM D 226.
          2.Type No. 40 base sheet, complying with ASTM D 2626.
          3.Type No. 90, complying with ASTM D 249.
          4.Modified bitumen single ply membrane, minimum 40 mils (1.02 mm) thick.
          5.MonierLifetile Roof System Components: MLT TileSeal Self Adhering Underlayment.
          6.Granular surface SBS modified bitumen membrane, minimum 40 mils (1.02 mm) thick at selvage edge.
 
          B.Nails: Conforming to ASTM A 641, Class 1. Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
          1.Type: Aluminum.
          2.Type: Copper or stainless steel.
          3.Type: Hot dipped galvanized.
          NOTE TO SPECIFIER: The MonierLifetile Roof System Components Collection offers the Quik Drive Screw Gun for a quick, easy and cost effective installation. Consult with manufacturer for additional information.
 
          C.Screw Fasteners: Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten.
          1.MonierLifetile Roof System Components: Quik Drive complying with ASTM 641, Class 1, with 2 inch or 2-1/2 inch (51 mm or 64 mm) Screws, Roofing Specific.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
          2.Fastener Type: Corrosion resistant fasteners formed from aluminum.
          3.Fastener Type: Corrosion resistant fasteners formed from coated or plated steel.
          4.Fastener Type: Corrosion resistant fasteners formed from copper.
          5.Fastener Type: Corrosion resistant fasteners formed from silicone bronze brass.
          6.Fastener Type: Corrosion resistant fasteners formed from stainless steel.
          ** NOTE TO SPECIFIER ** Select the required flashing material from the following paragraphs and delete those not required. Coordinate with flashing specified in other sections of the specification.
 
          D.Flashings:
          1.MonierLifetile Roof System Components: Ribbed Tile Pan - 26 gauge Galvanized Sheet Steel side wall flashing.
          2.MonierLifetile Roof System Components:
          a.Wakaflex universal flashing for abutments at chimneys, walls and other rising structures.
          b.Flash Bar metal flashing for chimneys and other roof to wall structures.
          ** NOTE TO SPECIFIER ** Select one of the following Material paragraphs and delete those not required.
          3.Material, Unless Otherwise Indicated. Steel sheet galvanized to G90/Z275 complying with ASTM A 653/A 653M; 26 gage, 0.018 inch (0.45 mm) minimum thickness.
          4.Material, Unless Otherwise Indicated: Sheet copper, 16 oz/square foot minimum thickness.
          5.Material, Unless Otherwise Indicated: Sheet lead, 2.5 pounds per square foot (12 kg/sq m) minimum thickness.
          6.Valley Flashings:
          a.MonierLifetile Roof System Components: Ribbed Valley Metal 1 inch Center Diverter, 26 gauge, Galvanized Sheet Steel.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Type: Single center diverter.
          c.Type: Double center diverter.
          ** NOTE TO SPECIFIER ** For extreme water flows, wider valley flashing may be necessary.
          d.Width: 24 inches (610 mm), minimum.
          e.Height of Center Diverter: 1 inch (25 mm), minimum.
          f.Height of Center Diverter: 1-1/2 inch (38 mm), minimum.
          g.Edge Returns: 1 inch (25 mm), minimum.
          h.Lap Joints: 6 inches (152 mm), minimum.
          ** NOTE TO SPECIFIER ** Select one of the following Plumbing Stack paragraphs or edit to suit project requirements.. The first is for malleable flashing for medium and high profile tiles. The second is for flat tiles.
          7.Plumbing Stacks and Other Pipes Penetrating Roof for Medium and High Profile Tiles: Lead sheet, 2.5 pounds per square foot (12 kg/sq m) minimum thickness; or dead soft aluminum sheet, 0.032 inch (0.8 mm) minimum thickness.
          8.Plumbing Stacks and Other Pipes Penetrating Roof for Flat Profile Tiles: Same type as for other flashings.
          NOTE TO SPECIFIER: Select adhesive if required, delete if not required.
 
          E.Adhesive:
          1.Asphalt plastic roof cement, Type II, non-asbestos, non-running, heavy body material composed of asphalt and other mineral ingredients, formulated for use with concrete roof tile.
          2.Concrete tile adhesive, must be identified by manufacturer as specifically formulated as a concrete roof tile adhesive.
          a.MonierLifetile Roof System Components: OSI RT 600 Adhesive, Black.
          ** NOTE TO SPECIFIER ** Select the eve closure required from the following paragraphs and delete those not required. The first two paragraphs apply to Standard Weight MonierLifetile Madera and Lightweight Cedarlite tile only; delete if not required.
 
          F.Eave Closures:
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile and fascia treatment.
          1.Prefabricated combination metal eave closure and drip, fastened at minimum 12 inches (305 mm) on center along eave.
          a.MonierLifetile Roof System Components: Eave Closure "T" - Metal.
          2.Prefabricated eave closure, fastened at minimum 18 inches (457 mm) on center along eave.
          3.Prefabricated EPDM synthetic rubber closure; profile to match tile.
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          4.Prefabricated metal eave closure; profile to match tile, fastened at minimum 18 inches (457 mm) on center along eave.
          a.MonierLifetile Roof System Components: Vented Eave Riser - Metal.
          b.MonierLifetile Roof System Components: Eave Closures - Metal.
 
          G.Eave Closures: Raised wood fascia/starter strip as indicated on drawings, fasten with minimum 3 fasteners per 38 inch (965 mm) strip.
 
          H.Horizontal Battens:
          NOTE TO SPECIFIER: Select battens required from the following paragraphs and delete those not required,
          1.MonierLifetile Roof System Components: Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 8 feet (2.44 m).
          2.MonierLifetile Roof System Components: Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 8 feet (2.44 m).
          3.MonierLifetile Roof System Components: Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 4 feet (1.22 m).
          4.MonierLifetile Roof System Components: Batten Extenders 18 inches (457 mm).
          ** NOTE TO SPECIFIER ** Select one of the following two material paragraphs and delete the one not required.
          5.Material: Standard or better Douglas Fir.
          6.Material: Standard or better Douglas Fir, pressure treated, and complying with AWPA C2 for above ground use.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          7.Size: 1 inch (25 mm) by 2 inches (51 mm), for standard installation.
          8.Size: 1 inch (25 mm) by 4 inches (102 mm), over vertical strapping.
          9.Do not use bowed or twisted battens.
 
          I.Vertical Strapping: Set at 24 inches (610 mm), maximum, on center.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Edit the third paragraph only for sizes between the sizes in the first and second paragraph.
          1.Size: 1/4 inch (6 mm) by 1-3/8 inch (35 mm).
          2.Size: 2 inches (51 mm) by 4 inches (102 mm).
          3.Size: ____________.
 
          J.Anchor Battens: Standard or better Douglas Fir.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. The first paragraph is for use only up to 16 inch spacing for vertical strapping.
          1.Size: 1 inch (25 mm) by 2 inches (51 mm).
          2.Size: 1 inch (25 mm) by 4 inches (102 mm).
          3.Size: 2 inches (51 mm) by 2 inches (51 mm).
 
          K.Hip & Ridge
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          1.MonierLifetile Roof System Components: Figaroll - Ridge Vent & Weather Block.
          2.MonierLifetile Roof System Components: 11 inch by 33 inch (279 by 838 mm) Zephyr Roll, Ridge Vent and Weather Block, Miami-Dade County Approved.
          3.MonierLifetile Roof System Components: 13.4 inch by 33 inch (340 by 839 mm) Zephyr Roll, Ridge Vent and Weather Block, Miami-Dade County Approved.
          4.MonierLifetile Roof System Components: Ridge Riser - Elevates ridge board to proper height.
 
          L.Rake & Gable End
          1.MonierLifetile prefabricated Rake and Ridge tile. Choose to match tile profile and color.
          NOTE TO SPECIFIER: The following two paragraphs apply to Standard Weight MonierLifetile Madera and Lightweight Cedarlite tile only.
          2.MonierLifetile Roof System Components: Metal Rake Trim.
          3.MonierLifetile Roof System Components: Gable End Rubber Wedges.
 
          M.Field Venting
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          1.MonierLifetile Roof System Components: Ubbink Vents.
          2.MonierLifetile Roof System Components: Zephyr Vents.
          ** NOTE TO SPECIFIER ** The following paragraphs represents the standard weight tile and accessory materials available in MonierLifetile's Florida Region; Pompano Beach Plant, 1369 Hammondville Road, Pompano Beach, FL 33069. Tel: 954-786-5380 and 800-818-0974; Boca Raton Plant, 135 N.W. 20th Street, Boca Raton, FL 33431. Tel: 561-338-8200 and 800-585-8453; Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Te1: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required. If more than one is required, be sure to indicate where each is to be used on the drawings or the specifications.
 
          2.4CONCRETE ROOF TILE - FLORIDA
          ** NOTE TO SPECIFIER ** Standard weight tiles weigh 600 lbs/square or more. Delete all but one of the following tile profiles. If more than one is required, be sure to indicate where each is to be used on the drawings or the specifications.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Pompano Beach Plant, 1369 Hammondville Road, Pompano Beach, FL 33069. Tel: 954-786-5380 and 800-818-0974. Select the Weight and the Profile required and delete those not required.
 
          A.Standard Weight Tile: Vanguard Roll profile.
          1.Finishing Tile: Provide manufacturer's Roll Rake and Roll Ridge tiles.
          2.Size: 16-1/2 inches (419 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 91 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 820 lbs (372 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Boca Raton Plant, 135 N.W. 20th Street, Boca Raton, FL 33431. Te1: 561-338-8200 and 800-585-8453. Select the Weight and the Profile required and delete those not required.
 
          B.Standard Weight Tile: Spanish S profile (FACS prefix).
          1.Finishing Tile: Provide manufacturer's SS cut and SS ridge tiles.
          2.Size: 18 inches by 10-1/2 inches, nominal.
          3.Coverage: 105 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 900 lbs (408 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Boca Raton Plant, 135 N.W. 20th Street, Boca Raton, FL 33431. Tel: 561-338-8200 and 800-585-8453. Select the Weight and the Profile required and delete those not required.
 
          C.Standard Weight Tile: Atlantis profile.
          1.Finishing Tile: Provide manufacturer's Thickbutts Ridge, Whole Starter, Half Starter, Whole Finisher and Half Finisher tiles.
          2.Size: 16 inches by 10 inches, nominal.
          3.Coverage: 123 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 1100 lbs (499 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          D.Standard Weight Tile: Espana profile.
          1.Finishing Tile: Provide manufacturer's Capri Trim, Hip Starter and Capri Apex 3-Way tiles.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 89 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 900 lbs (408 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
 
          E.Standard Weight Tile: Boosted Barcelona profile.
          ** NOTE TO SPECIFIER** Boosted Barcelona is an application of Barcelona which, when added to Barcelona field tile, creates the appearance of a mortar-boosted tile.
          1.Size: 13-1/2 inches (323 mm) by 6-1/2 inches (165 mm), nominal.
          2.Coverage: 10 percent application, 20 percent application, 30 percent application.
          3.Installed weight per square including field tile: 10 percent application, 936 lbs (425 kg), 20 percent application, 972 lbs (441 kg), 30 percent application, 1,008 lbs (457 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          4.Color and Finish: ________________.
          5.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Te1: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          F.Standard Weight Tile: Capri profile.
          1.Finishing Tile: Provide manufacturer's Rake, Ridge, Capri Trim, Hip Starter and Capri Apex 3-Way.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 94 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 1000 lbs (454 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          G.Standard Weight Tile: Saxony Slate profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4 Way tiles.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 94 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 1000 lbs (454 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          H.Standard Weight Tile: Saxony Shake profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4 Way tiles.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 94 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 1000 lbs (454 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          I.Standard Weight Tile: Saxony Split Shake profile.
          1.Finishing Tile: Provide manufacturer's 90 degree Rake, 3-Sided Ridge, 3-Sided Hip Starter and Apex 3 or 4 Way tiles.
          2.Size: 17 inches (432 mm) by 12-3/8 inches (314 mm), nominal.
          3.Coverage: 94 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight per square: Approximately 1000 lbs (454 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          ** NOTE TO SPECIFIER ** The tile in the following paragraph is available from MonierLifetile's Lake Wales Plant, 200 Story Road, Lake Wales, FL 33853. (P.O. Box 632, Lake Wales, FL 33859-0632), Tel: 863-678-9405 and 800-282-3633. Select the Weight and the Profile required and delete those not required.
 
          J.Standard Weight Tile: MonierLifetile Madera profile.
          1.Finishing Tile: Provide manufacturer's Rake, Hip/Ridge and Tapered Eave Starter tiles.
          2.Size: 13-1/2 inches (323 mm) by 13 inches (330 mm), nominal.
          3.Coverage: 120 field tiles per 100 square feet (9.29 sm) of roof area.
          4.Installed weight: Approximately 935 lbs (424 kg).
          ** NOTE TO SPECIFIER ** Select the paragraph for the color and finish required and delete those not required. Go to the Manufacturer's regional collection brochure for the colors available.
          5.Color and Finish: ________________.
          6.Color and Finish: As selected by the Architect.
          NOTE TO SPECIFIER: MonierLifetile offers a complete line of Roof System Components that are recommended to ensure an optimal roof installation. Select the Accessory Material items which are appropriate for the project and the system selected. Consult with the manufacturer for additional information on Roof System Components.
 
          2.5ACCESSORY MATERIALS - FLORIDA
          ** NOTE TO SPECIFIER ** Select the required underlayment from the following paragraphs and delete paragraphs not relevant to this project.
 
          A.Underlayment:
          1.Type No. 40 base sheet, complying with ASTM D 2626.
          2.Type No. 90, complying with ASTM D 249.
          3.Modified bitumen single ply membrane, minimum 40 mils (1.02 mm) thick.
          4.MonierLifetile Roof System Components: MLT TileSeal Self Adhering Underlayment.
          5.Granular surface SBS modified bitumen membrane, minimum 40 mils (1.02 mm) thick at selvage edge.
 
          B.Nails: Conforming to ASTM A 641, Class 1. Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
          1.Type: Aluminum.
          2.Type: Copper or stainless steel.
          3.Type: Hot dipped galvanized.
          NOTE TO SPECIFIER: The MonierLifetile Roof System Components Collection offers the Quik Drive Screw Gun for a quick, easy and cost effective installation. Consult with manufacturer for additional information.
 
          C.Screw Fasteners: Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten.
          ** NOTE TO SPECIFIER ** Select one of the following fastener paragraphs and delete those not required.
          1.MonierLifetile Roof System Components: Quik Drive 2-1/2 inch or 3 inch (64 mm or 76.2 mm) Screws, Roofing Specific, Miami Dade County Approved.
          2.MonierLifetile Roof System Components: Quik Drive complying with ASTM 641, Class 1, with 2 inch or 2-1/2 inch (51 mm or 64 mm) Screws.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
          3.Fastener Type: Corrosion resistant fasteners formed from aluminum.
          4.Fastener Type: Corrosion resistant fasteners formed from coated or plated steel.
          5.Fastener Type: Corrosion resistant fasteners formed from copper.
          6.Fastener Type: Corrosion resistant fasteners formed from silicone bronze brass.
          7.Fastener Type: Corrosion resistant fasteners formed from stainless steel.
          ** NOTE TO SPECIFIER ** Select to match profile of chosen concrete roof tile. Contact MonierLifetile for storm clip recommendations.
 
          D.Storm Clips:
          1.MonierLifetile Roof System Components: Wind Clips - Galvanized.
          2.Storm Clips _______________.
          ** NOTE TO SPECIFIER ** Select the required flashing material from the following paragraphs and delete those not required. Coordinate with flashing specified in other sections of the specification.
 
          E.Flashings:
          1.MonierLifetile Roof System Components: Ribbed Tile Pan - 26 gauge Galvanized Sheet Steel side wall flashing.
          2.MonierLifetile Roof System Components: Wakaflex universal flashing for abutments at chimneys, walls and other rising structures.
          3.MonierLifetile Roof System Components: Flash Bar metal flashing for chimneys and other roof to wall structures.
          ** NOTE TO SPECIFIER ** Select one of the following Material paragraphs and delete those not required.
          4.Material, Unless Otherwise Indicated. Steel sheet galvanized to G90/Z275 complying with ASTM A 653/A 653M; 26 gage, 0.018 inch (0.45 mm) minimum thickness.
          5.Material, Unless Otherwise Indicated: Sheet copper, 16 oz/square foot minimum thickness.
          6.Material, Unless Otherwise Indicated: Sheet lead, 2.5 pounds per square foot (12 kg/sq m) minimum thickness.
          7.Valley Flashings:
          a.MonierLifetile Roof System Components: Ribbed Valley Metal 1-1/2" Ctr. Diverter, 26 gauge, Galvanized Sheet Steel.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Type: Single center diverter.
          c.Type: Double center diverter.
          ** NOTE TO SPECIFIER ** For extreme water flows, wider valley flashing may be necessary.
          d.Width: 24 inches (610 mm), minimum.
          e.Height of Center Diverter: 1 inch (25 mm), minimum.
          f.Height of Center Diverter: 1-1/2 inch (38 mm), minimum.
          g.Edge Returns: 1 inch (25 mm), minimum.
          h.Lap Joints: 6 inches (152 mm), minimum.
          ** NOTE TO SPECIFIER ** Select one of the following Plumbing Stack paragraphs or edit to suit project requirements.. The first is for malleable flashing for medium and high profile tiles. The second is for flat tiles.
          8.Plumbing Stacks and Other Pipes Penetrating Roof for Medium and High Profile Tiles: Lead sheet, 2.5 pounds per square foot (12 kg/sq m) minimum thickness; or dead soft aluminum sheet, 0.032 inch (0.8 mm) minimum thickness.
          9.Plumbing Stacks and Other Pipes Penetrating Roof for Flat Profile Tiles: Same type as for other flashings.
          NOTE TO SPECIFIER: Select adhesive if required, delete if not required.
 
          F.Adhesive:
          1.Asphalt plastic roof cement, Type II, non-asbestos, non-running, heavy body material composed of asphalt and other mineral ingredients, formulated for use with concrete roof tile.
          2.Concrete tile adhesive, must be identified by manufacturer as specifically formulated as a concrete roof tile adhesive.
          ** NOTE TO SPECIFIER ** Select the eave closure required from the following paragraphs and delete those not required.
 
          G.Eave Closures:
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile and fascia treatment.
          1.Prefabricated combination metal eave closure and drip, fastened at minimum 12 inches (305 mm) on center along eave.
          a.MonierLifetile Roof System Components: Eave Closure "T" - Metal.
          2.Prefabricated eave closure, fastened at minimum 18 inches (457 mm) on center along eave.
          3.Prefabricated EPDM synthetic rubber closure; profile to match tile.
          a.MonierLifetile Roof System Components: Eave Closure, Rubber.
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          4.Prefabricated metal eave closure; profile to match tile, fastened at minimum 18 inches (457 mm) on center along eave.
          NOTE TO SPECIFIER: The following paragraph is recommended for inland areas, not coastal areas.
          a.MonierLifetile Roof System Components: Vented Eave Riser - Metal.
          b.MonierLifetile Roof System Components: Eave Closures - Metal.
 
          H.Eave Closures: Raised wood fascia/starter strip as indicated on drawings, fasten with minimum 3 fasteners per 38 inch (965 mm) strip.
 
          I.Horizontal Battens:
          NOTE TO SPECIFIER: Select battens required from the following paragraphs and delete those not required,
          1.MonierLifetile Roof System Components: Batten Extenders 18 inches (457 mm).
          2.MonierLifetile Roof System Components: Pressure Treated Battens 1 inch (25 mm) by 2 inches (51 mm) by 4 feet (1.22 m).
          ** NOTE TO SPECIFIER ** Delete one of the following three material paragraphs and delete those not required.
          3.Material: Standard or better Douglas Fir.
          4.Material: Standard or better Douglas Fir, pressure treated, and complying with AWPA C2 for above ground use.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          5.Size: 1 inch (25 mm) by 2 inches (51 mm), for standard installation.
          6.Size: 1 inch (25 mm) by 4 inches (102 mm), over vertical strapping.
          7.Do not use bowed or twisted battens.
 
          J.Vertical Strapping: Set at 24 inches (610 mm), maximum, on center.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Edit the third paragraph only for sizes between the sizes in the first and second paragraph.
          1.Size: 1/4 inch (6 mm) by 1-3/8 inch (35 mm).
          2.Size: 2 inches (51 mm) by 4 inches (102 mm).
          3.Size: ____________.
 
          K.Anchor Battens: Standard or better Douglas Fir.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. The first paragraph is for use only up to 16 inch spacing for vertical strapping.
          1.Size: 1 inch (25 mm) by 2 inches (51 mm).
          2.Size: 1 inch (25 mm) by 4 inches (102 mm).
          3.Size: 2 inches (51 mm) by 2 inches (51 mm).
 
          L.Hip & Ridge
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          1.MonierLifetile Roof System Components: Figaroll - Ridge Vent & Weather Block.
          2.MonierLifetile Roof System Components: 11 inch by 33 inch (279 by 838 mm) Zephyr Roll, Ridge Vent and Weather Block, Miami-Dade County Approved.
          3.MonierLifetile Roof System Components: 13.4 inch by 33 inch (340 by 839 mm) Zephyr Roll, Ridge Vent and Weather Block, Miami-Dade County Approved.
          4.MonierLifetile Roof System Components: Ridge Riser - Elevates ridge board to proper height.
 
          M.Rake & Gable End
          1.MonierLifetile prefabricated Rake and Ridge tile. Choose to match tile profile and color.
          NOTE TO SPECIFIER: The following two paragraphs apply to Standard Weight MonierLifetile Madera tile only.
          2.MonierLifetile Roof System Components: Metal Rake Trim.
          3.MonierLifetile Roof System Components: Gable End Rubber Wedges.
 
          N.Field Venting
          NOTE TO SPECIFIER: Select to match profile of concrete roof tile.
          1.MonierLifetile Roof System Components: Ubbink Vents.
          2.MonierLifetile Roof System Components: Zephyr Vents.
          ** NOTE TO SPECIFIER ** The following paragraphs represent the standard weight tile, light weight tile and Roof System Components products available in MonierLifetile's Hawaii Region: Hawaii, Hawaii Docks, Tacoma Plant, 10920 Steele Street Lakewood WA 98499. Tel: 800-699-8453. Select the Weight and the Profile required and delete those not required.
 
          2.6CONCRETE ROOF TILE - HAWAII
          ** NOTE TO SPECIFIER ** Standard weight tiles weigh 600 lbs/square or more. Delete all but one of the following tile profiles. If more than one is required, be sure to indicate where each is to be used on the drawings or the specifications.
 
          A.Standard Weight Tile: Boosted Barcelona profile.
          NOTE TO SPECIFIER: Boosted Barcelona is an application of Barcelona which, when added to Barcelona field tile, creates the appearance of a mortar-boosted tile.
          1.Size: 13-1/2 inches (323 mm