MasterFormat: 95
SpecWizard: customize this spec    Download this Metal Roof And Wall Panels Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Aeicor Metal Products, a Div. of Southern Metal Products, LLC Metal Roof And Wall Panels
 
         
SECTION 07410
 
         
METAL ROOF AND WALL PANELS
 
         
Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".
          ** NOTE TO SPECIFIER ** Aeicor Metal Products; standing seam, board and batten, fascia soffit, curved panel and walkway covers.
.
This section is based on the products of Aeicor Metal Products, which is located at:
          450 W. McNab Rd.
Fort Lauderdale, FL 33309
Tel: (954) 974-3300
Fax: (954) 247-3491
Email: bmeise@aeicormetals.com.
Web: http://www. 1800hurricane.com/aeicor.
[ Click Here ] for additional information.
          AEICOR has manufactured and installed metal roof and soffit systems throughout the Southeastern United States since 1978.

Standing Seam Systems:
Auto-Lock - Ideally suited for single-pitched roof runs. These systems are mechanically seamed in the field.
Snap Cap - These two-Piece systems are ideal for multi-pitched roof runs. The snap-on seam cover facilitates replacement of storm-damaged panels.
Board And Batten Systems:
Fascia/Soffit Systems:
Curved Panel Systems:
Walkway Covers:
.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Standing seam system.
 
          B.Board and batten system.
 
          C.Curved panel system.
 
          D.Fascia/soffit system.
 
          E.Walkway cover.
 
          F.Equipment screens.
 
          G.Canopies.
 
          H.Associated flashings, fasteners, clips, sealants and accessories.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 05120 - Structural Steel: Tolerances for primary and secondary building structure supporting framework.
 
          B.Section 05300 - Structural Metal Roof and Floor Decking: Roof decking material and installation.
 
          C.Section 05400 - Structural Steel Stud Framing: Exterior wall framing.
 
          D.Section 06100 - Rough Carpentry: Blocking and miscellaneous framing.
 
          E.Section 06125 - Wood Decking: Wood deck material and installation.
 
          F.Section 07210 - Building Insulation: Rigid insulation at insulated walls and roof decks.
 
          G.Section 07620 - Sheet Metal Flashing and Trim: Installation requirements.
 
          H.Section 07710 - Gutters and Downspouts: Roof edge coordination and attachment provisions.
 
          I.Section 07900 - Joint Sealants: Installation requirements.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.American Society for Testing and Materials (ASTM) D523 - Standard Test Method for Specular Gloss.
 
          B.American Society for Testing and Materials (ASTM) D659 - Standard Guide for Testing Industrial Water-Reducible Coatings.
 
          C.American Society for Testing and Materials (ASTM) D822 - Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings.
 
          D.American Society for Testing and Materials (ASTM) D2244 - Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates.
 
          E.Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA) - Architectural Sheet Metal Manual.
 
          F.Underwriters Laboratories (UL) - Building Materials Director.
 
          G.Underwriters Laboratories (UL) 580 - Wind Uplift Classification.
 
          1.4SYSTEM REQUIREMENTS
          ** NOTE TO SPECIFIER ** Standing seam UL 90 only. Delete if not required.
 
          A.Uplift Requirements:
          1.Design wind uplift load capacity of panel system capable of resisting the negative uplift pressure as follows:
          a.Provide UL rated roofing system that has been tested in accordance with UL 580 test procedure.
          ** NOTE TO SPECIFIER ** Rating for Auto-Lock Structural Profile and Auto-Lock High Profile only. Delete if not required.
          b.UL-90, 1 inch (25 mm) seam height.
          c.UL-90, 1-1/2 inch (38 mm) seam height.
          d.UL-90, 2 inch (51 mm) seam height.
          ** NOTE TO SPECIFIER ** Rating for Auto-Lock Structural Profile where rating based on Project wind loading. Delete if not required.
          2.Design wind uplift load capacity of panel system capable of resisting the negative and positive uplift pressure as calculated for the Project.
          ** NOTE TO SPECIFIER ** Verify ambient and surface temperature ranges for project. Delete if not required.
 
          B.Thermal Movements: Provide sheet metal roofing that allows for thermal movements resulting from 120 degrees F (49 degrees C) ambient change; 180 degrees F (82 degrees C) material surfaces range without permanent buckling, opening of joints, hole elongation, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects.
          1.Provide clips that resist rotation and avoid shear stress as a result of sheet metal roofing thermal movements.
          2.Provide slip critical details that prevent tension build-up causing buckling, oil canning and "popping" of system components.
 
          C.Because of inconsistencies in the alloys and galvanizing process, the light gauge metals used to roll form architectural panels and the uneven substrates over which these panels are applied, manufacturer can not control a certain amount of waviness, or oil canning, evident on longer panels, particularly when sunlight hits them at certain times of the day. This shall not be construed as a product defect and shall not be cause for rejection.
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.[ Product Data ]: Manufacturer's data sheets on each product to be used, including:
          1.Data substantiating materials comply with requirements.
          2.Detailed specification of construction and fabrication.
          3.Manufacturer's installation instructions.
          ** NOTE TO SPECIFIER ** Rating for Auto-Lock Structural Profile and Auto-Lock High Profile only. Delete if not required.
          4.Certified test reports indicating compliance with performance requirements specified herein and as follows:
          a.Certification by the manufacturer that the roofing assembly is listed by UL for the wind uplift rating specified with relevant construction number indicated.
          5.Clip fastener pull-out tests.
          6.Preparation instructions and recommendations.
          7.Storage and handling requirements and recommendations.
          8.Installation methods.
 
          C.Shop Drawings: Indicate dimensions, description of materials and finishes, general construction, specific modifications, component connections, anchorage methods, hardware, and installation procedures, plus the following specific requirements.
          1.Indicate material profile, jointing pattern, jointing details, fastening methods, and installation details.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          D.Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
 
          E.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square representing actual product, color, and patterns.
 
          1.6QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: Manufacturer shall have a minimum of 10 years experience supplying metal roofing/siding to the region where the work is to be done.
 
          B.Installer Qualifications:
          1.Acceptable to, licensed or certified by manufacturer.
          2.Not less than 5 years experience with systems.
          3.Successfully completed not less than 5 comparable scale projects using this system.
 
          C.Regulatory Requirements: Comply with local Building Code requirements if more restrictive than those specified.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          D.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
          3.Refinish mock-up area as required to produce acceptable work.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Protect against damage and discoloration.
 
          B.Handle panels with non-marring slings.
 
          C.Do not bend panels.
 
          D.Store panels above ground, with one end elevated for drainage.
 
          E.Protect panels against standing water and condensation between adjacent surfaces.
 
          F.If panels become wet, immediately separate sheets, wipe dry with clean cloth, and allow to air dry.
 
          G.Remove any strippable film coating prior to installation and do not allow it to remain on the panels in extreme cold, heat or in direct sunlight.
 
          H.Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          1.9WARRANTY
 
          A.Manufacturer shall stand behind installed system for the periods described herein, starting from Date of Substantial Completion against all the conditions indicated below. When notified in writing from Owner, Manufacturer shall, promptly and without inconvenience and cost to Owner, correct said deficiencies.
          1.Material warranty:
          a.20 years from date of Substantial Completion.
          ** NOTE TO SPECIFIER ** Signal Red Color finish warranty only. Delete if not required.
          b.10 years from date of Substantial Completion.
          c.Finish coating shall not peel, blister, chip, crack or check in finish, and shall not chalk in excess of 8 numerical ratings when measured in accordance with ASTM D659.
          d.Finish coating shall not change color or fade in excess of 5 NBS units as determined by ASTM D2244 and ASTM D822.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Aeicor Metal Products, a Div. of Southern Metal Products, LLC, which is located at: 450 W. McNab Rd. ; Fort Lauderdale, FL 33309; Toll Free Tel: 800-432-1803; Tel: 954-974-3300; Fax: 954-247-3491; Email: request info; Web: www.aeicormetals.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.2STANDING SEAM SYSTEMS
          ** NOTE TO SPECIFIER ** Minimum Pitch: Contact Factory. Purlin Spacing: Contact factory. Delete if not required.
 
          A.Auto-Lock Structural Profile: Mechanically seamed concealed fastener structural panel.
          1.As manufactured by Aeicor Metal Products.
          2.Wind Class: UL 90.
          3.Seam Height: 2 inches (51 mm).
          ** NOTE TO SPECIFIER ** Delete characteristic not required.
          4.Pan Width: 12 inches (305 mm).
          5.Pan Width: 16 inches (406 mm).
          6.Pan Width: 18 inches (457 mm).
          7.Pan Profile: Smooth.
          8.Pan Profile: Ribbed.
          9.Metal: 22 gauge (0.759 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          10.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          11.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          12.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          13.Metal: 16 oz. copper.
          14.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Minimum Pitch: 1/12. Purlin spacing: 5 feet with 14 inch pan, 4 feet with 20 inch pan. Delete if not required.
 
          B.Auto-Lock High Profile: Mechanically seamed concealed fastener panel.
          1.SS-1 as manufactured by Aeicor Metal Products.
          2.Wind Class: UL 90.
          3.Seam Height: 1-1/2 inches (38 mm).
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 14 inches (356 mm).
          5.Pan Width: 16 inches (406 mm).
          6.Pan Width: 20 inches (508 mm).
          7.Pan Profile: Smooth.
          8.Pan Profile: Ribbed.
          9.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          10.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          12.Metal: 16 oz. copper.
          13.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Minimum Pitch: 2-1/2 /12. Purlin spacing: 2 feet with 15 inch pan, 18 inches with 21 inch pan. Delete if not required.
 
          C.Auto-Lock Low Profile: Mechanically seamed concealed fastener panel.
          1.SS-2 as manufactured by Aeicor Metal Products.
          2.Wind Class: UL-90.
          3.Seam Height: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 15 inches (381 mm).
          5.Pan Width: 21 inches (533 mm).
          6.Pan Profile: Smooth.
          7.Pan Profile: Ribbed.
          8.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          9.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          10.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 16 oz. copper.
          12.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Minimum Pitch: 3 /12. Purlin spacing: 2 feet with 16 inch pan, 18 inches with 22 inch pan. Delete if not required.
 
          D.Snap Cap High Profile: Cap seamed concealed fastener panel.
          1.SS-3 as manufactured by Aeicor Metal Products.
          2.Wind Class: UL-90.
          3.Seam Height: 1-1/2 inches (38 mm).
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 16 inches (406 mm).
          5.Pan Width: 22 inches (559 mm).
          6.Pan Profile: Smooth.
          7.Pan Profile: Ribbed.
          8.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          9.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          10.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 16 oz. copper.
          12.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Minimum Pitch: 3 /12. Purlin spacing: Maximum 27 inches (689 mm). Delete if not required.
 
          E.Snap Cap Low Profile: Cap seamed concealed fastener flat panel.
          1.SS-4 as manufactured by Aeicor Metal Products.
          2.Wind Class: UL-90.
          3.Seam Height: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 12 inches (305 mm).
          5.Pan Width: 16 inches (406 mm).
          6.Pan Width: 22 inches (559 mm).
          7.Pan Profile: Smooth.
          8.Pan Profile: Ribbed.
          9.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish
          b.Finish: Kynar factory painted finish.
          10.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          12.Metal: 16 oz. copper.
          13.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.3BOARD AND BATTEN SYSTEMS
          ** NOTE TO SPECIFIER ** Minimum Pitch: 3 /12. Delete if not required.
 
          A.Board and Batten: Cap seamed concealed fastener panel.
          1.BB-1 as manufactured by Aeicor Metal Products.
          2.Batten Profile: 1-7/8 inches (48 mm) by 1 inch (25 mm) high.
          3.Batten Profile: 1-7/8 inches (48 mm) by 2 inch (51 mm) high.
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 12 inches (305 mm).
          5.Pan Width: 18 inches (457 mm).
          6.Pan Width: 24 inches (610 mm).
          7.Pan Profile: Smooth.
          8.Pan Profile: Ribbed.
          9.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          10.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          12.Metal: 16 oz. copper.
          13.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.4CURVED PANEL SYSTEMS
          ** NOTE TO SPECIFIER ** Minimum radius of 3 feet (915 mm).
 
          A.Curved Standing Seam: Mechanically seamed concealed fastener convex and concave curved panel.
          1.CP-4 as manufactured by Aeicor Metal Products.
          2.Wind Class: UL-90.
          3.Seam Height: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          4.Pan Width: 12 inches (305 mm).
          5.Pan Profile: Smooth.
          6.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish
          b.Finish: Kynar factory painted finish.
          7.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          8.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          9.Metal: 16 oz. copper.
          10.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.5FASCIA/SOFFIT SYSTEMS
          ** NOTE TO SPECIFIER ** Purlin spacing: 30 inches (762 mm) with 12 inch (305 mm) pan, 24 inches (610 mm) with 18 inch (457 mm) pan. Delete if not required.
 
          A.Fascia/Soffit: Concealed fastener panel.
          1.SP1-Flat as manufactured by Aeicor Metal Products.
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          2.Pan Width: 12 inches (305 mm).
          3.Pan Width: 18 inches (457 mm).
          4.Pan Profile: Smooth.
          5.Soffit Ventilation: None.
          6.Soffit Ventilation: Louvered panel.
          7.Soffit Ventilation: Perforated panel.
          8.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          9.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          10.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 16 oz. copper.
          12.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Purlin spacing: 30 inches (762 mm) with 12 inch (305 mm) pan, 24 inches (610 mm) with 18 inch (457 mm) pan. Delete if not required.
 
          B.Fascia/Soffit: Concealed fastener panel.
          1.SP3-Grooved as manufactured by Aeicor Metal Products.
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          2.Pan Width: 12 inches (305 mm).
          3.Pan Width: 18 inches (457 mm).
          4.Pan Profile: Ribbed.
          5.Soffit Ventilation: None.
          6.Soffit Ventilation: Louvered panel.
          7.Soffit Ventilation: Perforated panel.
          8.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          a.Finish: Mill finish.
          b.Finish: Kynar factory painted finish.
          9.Metal: 0.032 inch (0.813 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          10.Metal: 0.040 inch (1.024 mm) aluminum - Alloy 3105-H14.
          a.Finish: Kynar factory painted finish.
          11.Metal: 16 oz. copper.
          12.Metal: 20 oz. copper.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.6WALKWAY COVER
 
          A.Design: Refer to drawings for profiles and construction.
 
          B.Material and Finish:
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          1.Metal: 22 gauge (0.759 mm) GalvalumeType AZ55 (Premium).
          2.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          3.Finish: Mill finish.
          4.Finish: Kynar factory painted finish.
          5.Metal: .040 inch (1.024 mm) Aluminum - Alloy 3105-H14.
          6.Metal: .032 inch (0.813 mm) Aluminum - Alloy 3105-H14.
          7.Finish: Kynar factory painted finish.
          8.Metal: 16 oz. Copper
          9.Metal: 20 oz. Copper
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.7EQUIPMENT SCREENS
 
          A.Design: Refer to drawings for profiles and construction.
 
          B.Material and Finish:
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          1.Metal: 22 gauge (0.759 mm) GalvalumeType AZ55 (Premium).
          2.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium).
          3.Finish: Mill finish.
          4.Finish: Kynar factory painted finish.
          5.Metal: .040 inch (1.024 mm) Aluminum - Alloy 3105-H14.
          6.Metal: .032 inch (0.813 mm) Aluminum - Alloy 3105-H14.
          7.Finish: Kynar factory painted finish.
          8.Metal: 16 oz. Copper.
          9.Metal: 20 oz. Copper.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          2.8CANOPIES
 
          A.Design: Refer to drawings for profiles and construction.
 
          B.Material and Finish:
          ** NOTE TO SPECIFIER ** Delete characteristics not required.
          1.Metal: 22 gauge (0.759 mm) GalvalumeType AZ55 (Premium)
          2.Metal: 24 gauge (0.607 mm) GalvalumeType AZ55 (Premium)
          3.Finish: Mill finish
          4.Finish: Kynar factory painted finish.
          5.Metal: .040 inch (1.024 mm) Aluminum - Alloy 3105-H14.
          6.Metal: .032 inch (0.813 mm) Aluminum - Alloy 3105-H14.
          7.Finish: Kynar factory painted finish.
          8.Finish: Polyester factory painted finish.
          9.Metal: 16 oz. Copper
          10.Metal: 20 oz. Copper
 
          2.9MATERIALS
          ** NOTE TO SPECIFIER ** Delete material and accessories not required.
 
          A.Base Metal:
          1.Aluminum-zinc coated steel conforming to ASTM A792 SQ Grade 50B with AZ55 coating (Galvalume).
          2.Aluminum: Alloy 3004 conforming to ASTM B 209, H34 temper.
 
          B.Accessories:
          1.Provide manufacturer's standard accessories and other items essential to completeness of roof installation including anchor clips, trim, ridge and hip caps, closures, flashing, and fascia.
          2.Form flashings from same gauge and finish as roof panels.
          ** NOTE TO SPECIFIER ** Delete if batten system not required.
 
          C.Battens: Shall be of same material, finish and length as panels.
 
          D.Closures, Flashing and Trim: Shall be of same material, gauge, finish and panels.
 
          E.Concealed Clips:
          1.Clips as determined by manufacturer to suit specified performance requirements.
          2.Gable clips.
          3.Design clips for unlimited, unimpeded panel movement confirmed by testing, certified by an independent professional engineer.
          a.Testing: 100,000 cycles with 2 inch (51 mm) minimum panel movement in relation to anchored clip.
 
          F.Fasteners
          1.Screws: as determined by manufacturer to suit specified performance requirements.
          2.Blind Rivets: Solid-threaded, sealed stem type with EPDM washer under head.
          3.Exposed rivets shall match color finish of panel.
          4.Wood Deck - #8 x 1 inch (25 mm) spoiler tip screw (plated or stainless) 12 inches (305 mm) o/c.
          5.Metal Deck or Purlins - #8 x 1/2 inch (12 mm) Tek screws (plated or stainless) 12 inches (305 mm) o/c.
          6.For copper roofs, use stainless steel fasteners.
          ** NOTE TO SPECIFIER ** Delete if spaced structural panel system not required.
 
          G.Deflection Clips:
 
          H.Closures:
          1.Precut profile closure from cross-linked, closed cell polyethylene composition foam.
          2.Protect and support ridge and hip foam closures by a formed metal closure manufactured from same material, with same color and finish as roofing.
          3.Ridge closures: Factory-fabricated and hip closures field cut.
 
          I.Sealants: Provide products that do not contain oil, asbestos, or asphalt.
          1.Factory-Applied Sidelap Sealant: Non-drying, non-skinning, synthetic polymer-based, designed for metal-to-metal concealed joints.
          2.Field-Applied Panel End Sealant: Extruded polymeric butyl tape, non-skinning and not easily displaced under compression.
          3.Exposed Sealant: Single component, skinning, polyurethane joint sealant, with color to match panel.
 
          J.Slip - Sheeting: Red Rosin Paper at areas where roof system contacts weather treated wood blocking.
 
          2.10FABRICATION FOR SHEET METAL ROOFING
 
          A.Steel to be stretcher leveled and handled to minimize stress and waviness of sheet steel.
 
          B.Fabricate exposed items of pre-finished sheet metal, color to match panels.
 
          C.Hem exposed edges on underside 1/2 inch (12 mm) miter and seam corners.
 
          D.Provide for thermal expansion and contraction of the Work.
 
          E.Panning of panel ends is required at ridge, hip, and headwall conditions when slope is less than 3:12.
 
          F.Fabricate vertical faces with bottom edge formed outward 1/4 inch and hemmed to form drip.
 
          G.Panels shall be factory formed to required length, not to exceed 45 feet (13716 mm). Metal flashings and trim shall be factory formed from the same materials, gauge and finish as the roofing panels.
 
          H.Roofing panels shall be factory formed. Field formed panels are not acceptable.
 
          2.11FINISH
          ** NOTE TO SPECIFIER ** Delete Kynar finish if not required
 
          A.PVDF Exterior Coating:
          1.70 percent Kynar 500 coating baked on to a nominal dry-film thickness of 1.0 mil.
          2.20 percent reflective gloss (ASTM D523). (Low Gloss).
          3.0.3 mil baked on primer.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
          1.Inspect installed work of other trades and verify that work required is complete.
          2.Verify that installation will be made in accordance with approved shop drawings and manufacturer's instructions.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
          ** NOTE TO SPECIFIER ** Delete if not required
 
          A.Roof deck substrate specified in Section 06100.
          ** NOTE TO SPECIFIER ** Delete deck not required
          1.Solid 5/8 inch (16 mm) minimum thickness plywood substrate.
          a.Provide one layer of felt with horizontal overlaps and end laps staggered between layers.
          b.Lay parallel to ridgeline with 2 1/2 inches (64 mm) horizontal laps and 6 inches (152 mm) vertical laps.
          c.Start application at low point; work up roof laying plies in shingle fashion.
 
          B.Clean surfaces thoroughly prior to installation.
 
          C.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
          1.Follow roof panel manufacturer's directions.
          2.Lap panels away from prevailing wind direction.
          3.Do not stretch or compress panel side-laps.
          4.Secure panels without warp or deflection.
          5.Clean and dry surfaces prior to applying sealant.
          6.Exposed fasteners, except to fasten flashings, at fixed points, or as indicated on Drawings, will not be allowed.
 
          B.Cutting and Fitting:
          1.Neat, square and true. Torch cutting is prohibited where cut is exposed to final view.
          2.Openings 6 inches (153 mm) and larger in any direction: Shop fabricate and reinforce to maintain load capacity.
          3.Where necessary to saw-cut panels, debur cut edges.
 
          C.Flashing:
          1.Follow manufacturer's directions and architect approved Shop Drawings.
          2.Overlap roof panels at least 6 inches (153 mm).
          3.Install flashings to allow for thermal movement.
          4.Remove strippable protective film, if used, immediately preceding flashing installation.
 
          D.Dissimilar Metals:
          1.Where sheet metal is in contact with dissimilar metals, execute juncture to facilitate drainage and minimize possibility of galvanic action.
          2.At point of contact with dissimilar metal, coat metal with protective paint or tape placed between metals.
 
          E.Field apply sealant to penetrations, transitions, and other locations necessary (not batten seam) for airtight, waterproof installation.
 
          3.4PROTECTION
 
          A.Protect installed products until completion of project.
          1.Require workmen who will be walking on Roofing Panels to wear clean, soft-soled work shoes that will not pick up stones or other abrasive material, which could cause damage or discoloration.
          2.Protect work of other trades against damage and discoloration.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
 
         
END OF SECTION