SECTION 07550
MODIFIED BITUMINOUS MEMBRANE ROOFING
 
 
Copyright 2011 - 2017 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** Polyglass USA, Inc.; membrane roofing products.
.
This section is based on the products of Polyglass USA, Inc., which is located at:
1111 W. Newport Center Dr.
Deerfield Beach, FL 33442
Toll Free Tel: 888-410-1375
Tel: 954-233-1330
Fax: 954-418-4453
Email: request info (arcat@polyglass.com)
Web: www.polyglass.us
[ Click Here ] for additional information.
With its origins as a roofing contracting business, Polyglass became a leading manufacturer of modified roofing membranes in Europe in the 1960s and introduced its products and technology to the United States in 1992. Since then, Polyglass has grown to be a leading innovator in the roofing industry.
Decades of practical experience in the application of roofing and waterproofing materials provide the strong foundation for understanding the importance of contractor satisfaction. Launching innovative technologies such as Polyglass' patented self-adhered ADESO(R) Technology in the 1990s positioned Polyglass as a leader in self-adhered modified bitumen membranes.
As the company continued its growth, it was acquired in 2008 by Mapei(R), a global manufacturer of adhesives, sealants and chemical products for the building industry. Since the acquisition, Polyglass U.S.A.'s headquarters moved to Deerfield Beach, Florida and the company continues to realize significant product development and company growth.
Polyglass U.S.A. Inc. does not practice architecture or engineering. This specification is being provided as a guideline as to the general use and application of product contained within this specification. Project or other conditions may be present that could affect the use and/or performance of the provided specification information that is beyond the knowledge or control of Polyglass U.S.A. Inc.
 
PART 1 GENERAL
 
1.1
SECTION INCLUDES
 
** NOTE TO SPECIFIER ** Delete items below not required for project.
 
A.
Modified Bituminous Membrane Self Adhered Roofing.
B.
Modified Bituminous Membrane Torch Applied Roofing.
C.
Modified Bituminous Membrane Hot Mopped Applied Roofing.
D.
Modified Bituminous Membrane Cold Adhesive Applied Roofing.
E.
Roof Insulation.
1.2
RELATED SECTIONS
 
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
A.
Section _______ - Roof Deck Substrate Preparation.
B.
Section 05300 - Metal Deck.
C.
Section 06100 - Rough Carpentry.
D.
Section 06114 - Wood Blocking and Curbing: Wood nailers and cant strips.
E.
Section 07220 - Insulation Board: Insulation and fastening.
F.
Section 07620 - Sheet Metal Flashing and Trim: Weather protection for base flashings.
G.
Section 07710 - Manufactured Roof Specialties: Counter flashing gravel stops, and fascias.
H.
Section 07724 - Roof Hatches: Frame and integral curb; Counter flashing.
I.
Section 08620 - Unit Skylights: Skylight frame and integral curb and counter flashing.
J.
Section 08630 - Metal-Framed Skylights: Skylight frame and integral curb and counter flashing.
K.
Section 08950 - Translucent Wall and Roof Assemblies: Counter flashing
L.
Section 08960 - Sloped Glazing Assemblies: Counter flashing.
M.
Section 15120 - Piping Specialties: Roof Drains, Sumps.
1.3
REFERENCES
 
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
A.
ASTM C 1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board.
B.
ASTM D 41 - Standard Specification for Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing.
C.
ASTM D 312 - Standard Specification for Asphalt used in Roofing.
D.
ASTM D 1970 - Specification for Sheet Materials, Self-Adhering Polymer Modified Bituminous, Used as Steep Roofing Underlayment for Ice Dam Protection.
E.
ASTM D 6162 - Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements.
F.
ASTM D 6163 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements.
G.
ASTM D 6164 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements.
H.
ASTM D 6222 - Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements.
I.
ASTM D 6223 - Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements.
J.
ASTM D 6757 - Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing.
K.
ASTM D 7897 - Standard Practice for Laboratory Soiling and Weathering of Natural Exposure on Solar Reflectance and Thermal Emittance.
L.
NRCA - The NRCA Roofing and Waterproofing Manual. National Roofing Contractors Association (NRCA) - Roofing and Waterproofing Manual.
M.
Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA) - Architectural Sheet Metal Manual.
N.
ANSI-SPRI ES-1 Wind Design Standard for Edge Systems used with Low Slope Roofing Systems.
O.
UL - Fire Resistance Directory.
P.
FM Approvals - Roof Coverings and/or RoofNav assembly database.
Q.
FBC - Florida Building Code.
R.
Miami-Dade Building Code Compliance - N.O.A. (Notice of Acceptance)
S.
Texas Department of Insurance - Product Evaluation.
1.4
CODE AND TEST REQUIREMENTS
A.
Perform work in accordance with all federal, state and local codes.
 
** NOTE TO SPECIFIER ** Edit the following paragraphs as required as appropriate to code, and the Owner, or Owner's Insurance Underwriter requirements. Insurance underwriters will assess Owner's building for floor and roof assembly types and determine insurance premiums accordingly. Delete paragraphs that are inapplicable.
 
B.
Exterior Fire Test Exposure: Provide a roofing system achieving a UL Class rating for roof slopes indicated on the Contract Drawings.
 
** NOTE TO SPECIFIER ** Delete roof class rating not required.
 
1.
UL Class A rating.
2.
UL Class B rating.
3.
UL Class C rating.
 
** NOTE TO SPECIFIER ** Retain the next paragraph if wind calculations are to be based on ASCE-7.
 
C.
Windstorm Classification: Provide a roofing system, which will achieve the required uplift resistance as calculated in accordance with the most current revision of ASCE 7 or as listed in the current FM Approvals - Approved Roof Coverings and/or RoofNav assembly database.
 
** NOTE TO SPECIFIER ** Delete roof wind uplift rating not required where recovering an existing roof.
 
1.
60 psf of uplift resistance.
2.
75 psf of uplift resistance.
3.
90 psf of uplift resistance.
4.
105 psf of uplift resistance.
5.
___ psf of uplift resistance.
 
** NOTE TO SPECIFIER ** Retain the next paragraph if wind calculations are to be based on FM ratings.
 
D.
FM Rating: Provide a roofing system, which will achieve the following rating as listed in the current FM Approval Guide.
 
NOTE TO SPECIFIER ** Select FM rating. Delete eight of the next nine paragraphs and insert rating where not listed.
 
1.
FM 1-60.
2.
FM 1-90.
3.
FM 1-105.
4.
FM 1-120.
5.
FM 1-135.
6.
FM 1-205.
7.
FM 1-270.
8.
FM 1-300.
9.
FM 1-___
 
** NOTE TO SPECIFIER ** Retain the following two paragraphs only if Polyglass Polyfresko highly reflective modified bitumen membrane is specified.
 
E.
Cool Roof Rating Council (CRRC) Reflectivity/thermal emittance shall meet the following minimum requirements:
1.
Initial Solar Reflectance Index (SRI) not less than 96 and Thermal Emittance not less than 0.90 when tested according to Cool rating Council's CRRC-1.
F.
LEED: The roof system shall meet the reflectivity and emissivity criteria to qualify for two points under the LEED credit category, Credit 7.2, Sustainable Sites - Heat Island Reduction (Roofs).
 
** NOTE TO SPECIFIER ** Retain the following paragraphs for roofing applications only.
 
G.
Roof system shall have been tested in compliance with the following codes and test requirements:
1.
Florida FBC (For use outside Miami-Dade and Broward Counties):
a.
Membrane Systems FL1654
b.
Roofing Underlayments FL5259
c.
Roofing Cements and Coatings FL10291
2.
Miami-Dade County:
a.
Self-Adhered Membrane Systems Over:
1)
Concrete Decks N.O.A.
2)
Lightweight Concrete Decks N.O.A.
3)
Recover Decks N.O.A.
4)
Steel Decks N.O.A.
5)
Wood Decks N.O.A.
b.
Torch, Mop, and Cold Adhesive Applied Membrane Systems Over:
1)
Concrete Decks N.O.A.
2)
Lightweight Concrete Decks N.O.A.
3)
Recover Decks N.O.A.
4)
Steel Decks N.O.A.
5)
Wood Decks N.O.A.
c.
Roofing Cements and Coatings
1)
Polyglass Coatings and Mastics N.O.A.
3.
International Code Council Evaluation Service (ICC-ES):
a.
Membrane Systems
1)
ESR-2018
4.
Texas Department of Insurance:
a.
Product Evaluation RC-96
5.
Underwriters Laboratories:
a.
Certification TGFU.R14571
6.
FM Approvals:
a.
FM Listed and Approved
1.5
SUBMITTALS
A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
1.
Preparation instructions and recommendations.
2.
Storage and handling requirements and recommendations.
3.
Installation instructions.
C.
Shop Drawings: Submit shop drawings including installation details of roofing, flashing, fastening and insulation, including notation of roof slopes and fastening patterns of insulation and base modified bitumen membrane, prior to job start.
D.
Design Pressure Calculations: Submit design pressure calculations for the roof area in accordance with ASCE 7-05 and local Building Code requirements. Include a roof system attachment analysis report, certifying the system's compliance with applicable wind load requirements before Work begins. Report shall be signed and sealed by a Professional Engineer registered in the State of the Project who has provided roof system attachment analysis for not less than 5 consecutive years.
E.
Verification Samples: For each modified bituminous membrane ply product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
F.
Manufacturer's Field Reports: Submit as required.
G.
Manufacturer's Certificates: Certify products meet or exceed specified requirements.
H.
Closeout Submittals: Provide manufacturer's maintenance instructions that include recommendations for periodic checking and adjustment of cable tension and periodic cleaning and maintenance of all railing and infill components.
1.6
QUALITY ASSURANCE
A.
Perform Work in accordance with NRCA Roofing and Waterproofing Manual.
B.
Manufacturer Qualifications: Manufacturer: Company specializing in manufacturing products specified in this section with minimum ten years documented experience.
C.
Installer Qualifications: Company specializing in performing Work of this section with minimum three years documented experience and approved as a Registered Applicator by the Modified Bituminous Membrane Roofing manufacturer.
1.7
PRE-INSTALLATION MEETINGS
A.
Convene minimum one week prior to commencing Work of this section.
B.
Review installation procedures and coordination required with related Work.
C.
Inspect and make notes of job conditions prior to installation:
1.
Record minutes of the conference and provide copies to all parties present.
2.
Identify all outstanding issues in writing designating the responsible party for follow-up action and the timetable for completion.
3.
Installation of roofing system shall not begin until all outstanding issues are resolved to the satisfaction of the Architect.
1.8
DELIVERY, STORAGE, AND HANDLING
A.
Deliver and store products in manufacturer's unopened packaging with labels intact until ready for installation.
B.
Store all roofing materials in a dry place, on pallets or raised platforms, out of direct exposure to the elements until time of application. Store materials at least 4 inches above ground level and covered with "breathable" tarpaulins.
C.
Stored in accordance with the instructions of the manufacturer prior to their application or installation. Store roll goods on end on a clean flat surface. No wet or damaged materials will be used in the application.
D.
Store at room temperature wherever possible, until immediately prior to installing the roll. During winter, store materials in a heated location with a 50 degree F (10 degree C) minimum temperature, removed only as needed for immediate use. Keep materials away from open flame or welding sparks.
E.
Avoid stockpiling of materials on roofs without first obtaining acceptance from the Architect/Engineer.
F.
Adhesive storage shall be between the range of above 40 degree F (4 degree C) and below 80 degree F (27 degree C). Area of storage shall be constructed for flammable storage.
1.9
COORDINATION
A.
Coordinate Work with installing associated metal flashings as work of this section proceeds.
1.10
PROJECT CONDITIONS
A.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
** NOTE TO SPECIFIER ** Select the warranty required from the following paragraphs and delete those not required. Various Polyglass warranties are available. Warranties range from limited materials warranties to limited and full-systems warranties. Additional charges are required for non-prorated, no dollar limit warranties.
 
1.11
WARRANTY
A.
Upon completion of the work, provide the Manufacturer's written and signed Limited Roofing Materials Warranty, warranting that, if a leak develops in the roof during the term of this warranty, due either to defective material, the manufacturer shall provide the Owner, at the Manufacturer's expense, with the material necessary to return the defective area to a watertight condition.
 
** NOTE TO SPECIFIER ** Delete warranty length not required.
 
1.
Warranty Period: 10 years from date of acceptance.
2.
Warranty Period: 12 years from date of acceptance.
B.
Upon completion of the work, provide the Manufacturer's written and signed Labor and Materials Warranty, warranting that, if a leak develops in the roof during the term of this warranty, due to defective material, the manufacturer shall provide the Owner, at the Manufacturer's expense, with the material necessary to return the defective area to a watertight condition, including labor to install such materials to remedy.
 
** NOTE TO SPECIFIER ** Delete warranty length not required.
 
1.
Warranty Period: 10 years from date of acceptance.
2.
Warranty Period: 12 years from date of acceptance.
3.
Warranty Period: 15 years from date of acceptance.
4.
Warranty Period: 20 years from date of acceptance.
C.
Upon completion of the work, provide the Manufacturer's written and signed Roofing System Warranty, warranting that, if a leak develops in the roof during the term of this warranty, due either to defective material or defective workmanship by the installing contractor, the manufacturer shall provide the Owner, at the Manufacturer's expense, with no dollar limit, the labor and material necessary to return the defective area to a watertight condition.
 
** NOTE TO SPECIFIER ** Delete warranty length not required.
 
1.
Warranty Period: 10 years from date of acceptance.
2.
Warranty Period: 12 years from date of acceptance.
3.
Warranty Period: 15 years from date of acceptance.
4.
Warranty Period: 20 years from date of acceptance.
 
** NOTE TO SPECIFIER ** Contractor warranties are recommended and are becoming more common (as specified by Registered Roof Consultants). Such warranties generally ensure a more vested interest in the integrity of the installation. However, this typically limits the number of contractors qualified and/or willing to bid the project.
 
D.
Contractor is to guarantee all work against defects in materials and workmanship for a period indicated following final acceptance of the Work.
1.
Warranty Period: 2 years.
PART 2 PRODUCTS
 
2.1
MANUFACTURERS
A.
Acceptable Manufacturer: Polyglass USA, Inc., which is located at: 1111 W. Newport Center Dr.; Deerfield Beach, FL 33442; Toll Free Tel: 888-410-1375; Tel: 954-233-1330; Fax: 954-418-4453; Email: request info (arcat@polyglass.com); Web: www.polyglass.us
 
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
** NOTE TO SPECIFIER ** Delete insulation if not required. Coordinate with Section07220 - Roof Insulation Board as required for the project.
 
2.2
INSULATION
 
** NOTE TO SPECIFIER ** Select the insulation required from the following paragraphs and delete those not required.
 
A.
Polyglass Polytherm: Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to non-asphaltic, fiber- reinforced organic felt facers. Polytherm is offered in a variety of thicknesses, providing long-term thermal resistance (LTTR) values from 5.7 to 26.8. Available in 4 foot by 8 foot (1220 mm by 2440 mm) and 4 foot by 4 foot (1220 mm by 1220 mm) panels. Manufactured in accordance with ASTM C 1289, Type II, Class 1, Grade 2 (20 psi), or Grade 3 (25 psi) and CAN/ULC-S704 type 2, Class 3 or Type 3, Class 3.
 
** NOTE TO SPECIFIER ** Insert the insulation thickness and thermal resistance required on the following paragraphs and delete those not required.
 
1.
Board Thickness: ______
2.
Thermal Resistance: _____
B.
Polyglass Tapered Polytherm: Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to non-asphaltic, fiber- reinforced organic felt facers. Tapered Polytherm is offered in a variety of slopes, to achieve positive drainage as well as long-term thermal resistance (LTTR). Available in 4 foot by 4 foot (1220 mm by 1220 mm) panels with 1/8 inch (3 mm), 1/4 inch (6 mm) and 1/2 inch (12 mm) per foot slope. Manufactured in accordance with ASTM C 1289, Type II, Class 1, Grade 2 (20 psi) 3, or Grade 3 (25 psi) and CAN/ULC-S704 type 2, Class 3 or Type 3, Class 3.
 
** NOTE TO SPECIFIER ** Select and complete one of the following paragraphs and delete the one not required.
 
1.
Per Foot Slope Required: ______
2.
Provide minimum slope indicated on the Drawings.
 
** NOTE TO SPECIFIER ** Select roof board if required from the following paragraphs and delete if not required.
 
2.3
ROOF COVER BOARD
A.
Securock Gypsum-Fiber Roof Board: Fiber reinforced gypsum panel available in 4 foot by 8 foot (1220 mm by 2440 mm) and 4 foot by 4 foot (1220 mm by 1220 mm) panels and board thickness of 1/4 inch (6 mm), 1/2 inch (12 mm) and 5/8 inch (16 mm), manufactured to conform to ASTM C 1278.
B.
DensDeck Prime Roof Board: Enhanced to provide a broader compatibility for adhered, self-adhered, hot-mopped, cold adhesive, and torch-applied modified bitumen membranes. Board thickness of 1/4 inch (6 mm), 1/2 inch (12 mm) and 5/8 inch (16 mm), manufactured to conform to ASTM C 1177.
C.
Wood Fiber ASTM C 209 (six sided asphalt impregnated only) Minimum 1/2 inch (12 mm) thickness.
 
** NOTE TO SPECIFIER ** Select the Roofing System required from the following paragraphs and delete those not required. Consult the following codes used in the spec numbers below in making selections:
Series: 100 = 1 ply, 200 = 2 plys, 300 = 3 plys, 400 = 4 plys.
Substrate Type: W = Wood, M = Metal, C = Concrete, L = Lightweight.
Insulation: I = Insulated.
Cover Boards: Optional.
System Types: SBS = SBS Modified System, APP = APP Modified Systems.
Attachment Methods: SA = Self Adhered, TOR Torch Applied, HOT, Hot Mopped, COL = Cold Adhesive.
 
2.4
SELF ADHERED ROOF SYSTEM
A.
Spec # 200 M I SA SA: Self Adhered, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following Cap Sheet paragraphs and delete the those not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular top surface and a split release film on the bottom surface.
4.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
5.
Flashing: Same material as used for roof membrane.
 
** NOTE TO SPECIFIER ** Select one of the following insulation paragraphs and delete those not required
 
6.
Insulation: As specified in Section 07220 - Roof Insulation Board.
7.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220 - Roof Insulation Board.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
8.
Cover Board: DensDeck Prime.
9.
Cover Board: Securock Roof Board.
B.
Spec # 200 W SA SA: Self Adhered, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following Cap Sheet paragraphs and delete the those not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
5.
Anchor Membrane: Polyanchor Synthetic Anchor Sheet.
6.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
7.
Cover Board: DensDeck Prime.
8.
Cover Board: Securock.
C.
Spec # 200 C I SA SA: Self Adhered, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following Cap Sheet paragraphs and delete the one not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
5.
Flashing: Same material as roof membrane.
6.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
7.
Cover Board: DensDeck Prime.
8.
Cover Board: Securock Roof Board
D.
Spec # 200 W I SA SA: Self Adhered, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following Cap Sheet paragraphs and delete the one not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
5.
Flashing: Same material as roof membrane.
6.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
7.
Cover Board: DensDeck Prime.
8.
Cover Board: Securock Roof Board
E.
Spec # 300 W I SA SA: Self Adhered, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Mid Ply: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
5.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
6.
Flashing: Same material as roof membrane.
7.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
8.
Cover Board: DensDeck Prime.
9.
Cover Board: Securock Roof Board
F.
Spec # 300 M I SA SA: Self Adhered, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete the one not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Mid Ply Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
5.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
6.
Flashing: Same material as roof membrane.
7.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
8.
Cover Board: DensDeck Prime.
9.
Cover Board: Securock Roof Board
G.
Spec # 300 C SA SA: Self Adhered, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Mid Ply Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
5.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
6.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
7.
Cover Board: DensDeck Prime.
8.
Cover Board: Securock Roof Board
H.
Spec # 300 W SA SA: Self Adhered, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Mid Ply: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
5.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
6.
Anchor Membrane: Polyanchor Synthetic Anchor Sheet
7.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete the one not required.
 
8.
Cover Board: DensDeck Prime.
9.
Cover Board: Securock.
I.
Spec # 300 C I SA SA: Self Adhered, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete the one not required.
 
1.
Cap Sheet: Elastoflex SA P SBS with granular top surface and a split release film on the bottom surface.
2.
Cap Sheet: Polyfresko G SA with a reflective granular top surface and a split release film on the bottom surface.
3.
Cap Sheet: Polyflex SA P with a granular-free top surface and a split release film on the bottom surface.
4.
Mid Ply Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on the top surface and a split release film on the bottom surface.
5.
Base Sheet: Elastoflex SA V SBS with a polyolefin film (with lay lines) on top surface and a split release film on the bottom surface.
6.
Flashing: Same material as roof membrane.
7.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
8.
Cover Board: DensDeck Prime.
9.
Cover Board: Securock Roof Board
2.5
TORCH APPLIED ROOF SYSTEM
A.
Spec # 200 W APP TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
3.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elatoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
4.
Base Sheet: Polyglass G2 Base.
5.
Base Sheet: Polyglass APP Base
6.
Base Sheet: Polyflex
7.
Base Sheet: Polyflex SA Base
8.
Base Sheet: Polybond
9.
Base Sheet: Elastoflex SA V
10.
Flashing: Polyglass Flashing.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
11.
Cover Board: DensDeck Prime.
12.
Cover Board: Securock Roof Board.
B.
Spec # 200 W I APP TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
3.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
4.
Base Sheet: Polyglass G2 Base.
5.
Base Sheet: Polyglass APP Base
6.
Base Sheet: Polyflex with top sanded surface.
7.
Base Sheet: Elastoflex SA V
8.
Base Sheet: Polyflex SA Base
9.
Flashing: Same material as roof membrane.
10.
Insulation: Polytherm; Tapered Polytherm or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
11.
Cover Board: DensDeck Prime.
12.
Cover Board: Securock Roof Board.
C.
Spec # 300 W APP TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surfac
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
3.
Mid Ply: Polyflex with top sanded surface.
4.
Mid Ply: Polybond with top sanded surface.
5.
Mid Ply: Polyglass APP Base.
 
** NOTE TO SPECIFIER ** The following base sheets are optional. Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Polyglass APP Base
9.
Base Sheet: Polyflex with top sanded surface.
10.
Base Sheet: Polybond with top sanded surface
11.
Base Sheet: Polyflex SA Base
12.
Base Sheet: Elastoflex SA V
13.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: DensDeck Prime.
15.
Cover Board: Securock Roof Board.
D.
Spec # 300 WI APP TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
3.
Mid Ply: Polyflex with top sanded surface.
4.
Mid Ply: Polybond with top sanded surface.
5.
Mid Ply: Polyglass APP Base.
 
** NOTE TO SPECIFIER ** The following base sheets are optional. Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Polyglass APP Base
9.
Base Sheet: Elastoflex SA V
10.
Base Sheet: Polyflex with top sanded surface.
11.
Base Sheet: Polybond with top sanded surface
12.
Base Sheet: Polyflex SA Base
13.
Flashing: Same material as roof membrane.
14.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
E.
Spec # 200 M I SBS TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Elastoflex SA V .
9.
Base Sheet: Elastobase
10.
Base Sheet: Elastobase P
11.
Base Sheet: Elastoflex S6
12.
Base Sheet: Elastoshield TS
13.
Base Sheet: Elastoshield S6 HT
14.
Flashing: Same material as roof membrane.
15.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
16.
Cover Board: DensDeck Prime.
17.
Cover Board: Securock Roof Board.
F.
Spec # 300 C SBS TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet/Mechanically Fastened: Elastoflex V SBS with top sanded surface.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastoflex SA V Plus or Elastoflex SA V
15.
Base Sheet: Elastobase
16.
Base Sheet: Elastobase P
17.
Base Sheet: Elastoflex S6
18.
Base Sheet: Elastoshield TS
19.
Base Sheet: Elastoshield S6 HT
20.
Flashing: Polyglass Flashing.
21.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
22.
Cover Board: DensDeck Prime.
23.
Cover Board: Securock Roof Board.
G.
Spec # 300 CI SBS TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet/Mechanically Fastened: Elastoflex V 2.0 mm SBS with sanded surface.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastoflex SA V
15.
Base Sheet: Elastobase
16.
Base Sheet: Elastobase P
17.
Base Sheet: Elastoflex S6
18.
Base Sheet: Elastoshield TS
19.
Base Sheet: Elastoshield S6 HT
20.
Flashing: Same material as roof membrane.
21.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
22.
Cover Board: DensDeck Prime.
23.
Cover Board: Securock Cover Board.
H.
Spec # 200 M I APP TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
3.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
4.
Base Sheet: Polyglass G2 Base.
5.
Base Sheet: Polyglass APP Base
6.
Base Sheet: Polyflex with top sanded surface.
7.
Base Sheet: Polyflex SA Base
8.
Base Sheet: Elastoflex SA V
9.
Flashing: Same material as roof membrane.
10.
Insulation: Polytherm; Tapered Polytherm or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
11.
Cover Board: DensDeck Prime.
12.
Cover Board: Securock Roof Board.
I.
Spec # 300 M I APP TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
3.
Mid Ply: Polyflex with top sanded surface.
4.
Mid Ply: Polybond with top sanded surface.
5.
Mid Ply: Polyglass APP Base.
 
** NOTE TO SPECIFIER ** The following base sheets are optional. Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Polyglass APP Base
9.
Base Sheet: Elastoflex SA V
10.
Base Sheet: Polyflex with top sanded surface.
11.
Base Sheet: Polyflex SA Base
12.
Base Sheet: Polybond with top sanded surface
13.
Flashing: Same material as roof membrane.
14.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
J.
Spec # 300 W I SBS TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet/Mechanically Fastened: Elastoflex V 2.0 mm SBS with sanded surface.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastoflex SA V
15.
Base Sheet: Elastobase
16.
Base Sheet: Elastobase P
17.
Base Sheet: Elastoflex S6
18.
Base Sheet: Elastoshield TS
19.
Base Sheet: Elastoshield S6 HT
20.
Flashing: Same material as roof membrane.
21.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
22.
Cover Board: DensDeck Prime.
23.
Cover Board: Securock Cover Board.
K.
Spec # 300 M I SBS TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet/Mechanically Fastened: Elastoflex V 2.0 mm SBS with sanded surface.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastoflex SA V
15.
Base Sheet: Elastobase
16.
Base Sheet: Elastobase P
17.
Base Sheet: Elastoflex S6
18.
Base Sheet: Elastoshield TS
19.
Base Sheet: Elastoshield S6 HT
20.
Flashing: Same material as roof membrane.
21.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
22.
Cover Board: DensDeck Prime.
23.
Cover Board: Securock Cover Board.
L.
Spec # 200 C SBS TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Elastoflex SA V .
9.
Base Sheet: Elastobase
10.
Base Sheet: Elastobase P
11.
Base Sheet: Elastoflex S6
12.
Base Sheet: Elastoshield TS
13.
Base Sheet: Elastoshield S6 HT
14.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
M.
Spec # 200 C I SBS TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Elastoflex SA V .
9.
Base Sheet: Elastobase
10.
Base Sheet: Elastobase P
11.
Base Sheet: Elastoflex S6
12.
Base Sheet: Elastoshield TS
13.
Base Sheet: Elastoshield S6 HT
14.
Flashing: Same material as roof membrane.
15.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
16.
Cover Board: DensDeck Prime.
17.
Cover Board: Securock Roof Board.
N.
Spec # 300 W SBS TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet/Mechanically Fastened: Elastoflex V 2.0 mm SBS with sanded surface.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastoflex SA V
15.
Base Sheet: Elastobase
16.
Base Sheet: Elastobase P
17.
Base Sheet: Elastoflex S6
18.
Base Sheet: Elastoshield TS
19.
Base Sheet: Elastoshield S6 HT
20.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
21.
Cover Board: DensDeck Prime.
22.
Cover Board: Securock Cover Board.
O.
Spec # 200 W I SBS TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
5.
Cap Sheet: Polyfresko G SBS with reflective granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Elastoflex SA V .
9.
Base Sheet: Elastobase
10.
Base Sheet: Elastobase P
11.
Base Sheet: Elastoflex S6
12.
Base Sheet: Elastoshield TS
13.
Base Sheet: Elastoshield S6 HT
14.
Flashing: Same material as roof membrane.
15.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
16.
Cover Board: DensDeck Prime.
17.
Cover Board: Securock Roof Board.
P.
Spec # 200 C APP TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
3.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
4.
Base Sheet: Polyglass G2 Base.
5.
Base Sheet: Polyglass APP Base
6.
Base Sheet: Polyflex with top sanded surface.
7.
Base Sheet: Elastoflex SA V
8.
Base Sheet: Polyflex SA Base
9.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
10.
Cover Board: DensDeck Prime.
11.
Cover Board: Securock Roof Board.
Q.
Spec # 200 C I APP TOR: Torch applied, two ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular top surface except at selvage, which is granule free.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
3.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
4.
Base Sheet: Polyglass G2 Base.
5.
Base Sheet: Polyglass APP Base
6.
Base Sheet: Polyflex with top sanded surface.
7.
Base Sheet: Elastoflex SA V
8.
Base Sheet: Polyflex SA Base
9.
Flashing: Same material as roof membrane.
10.
Insulation: Polytherm; Tapered Polytherm or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
11.
Cover Board: DensDeck Prime.
12.
Cover Board: Securock Roof Board.
R.
Spec # 300 C APP TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surface
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
3.
Mid Ply: Polyflex with top sanded surface.
4.
Mid Ply: Polybond with top sanded surface.
5.
Mid Ply: Polyglass APP Base.
 
** NOTE TO SPECIFIER ** The following base sheets are optional. Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Polyglass APP Base
9.
Base Sheet: Polyflex with top sanded surface.
10.
Base Sheet: Polybond with top sanded surface
11.
Base Sheet: Polyflex SA Base
12.
Base Sheet: Elastoflex SA V
13.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: DensDeck Prime.
15.
Cover Board: Securock Roof Board.
S.
Spec # 300 C I APP TOR: Torch applied, three ply Polyglass reinforced modified bituminous roofing system for installation over insulation on a new or accepted, prepared existing roof substrate. Base sheet mechanically fastened.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Polyflex G APP with granular surface.
2.
Cap Sheet: Polyfresko G APP with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
3.
Mid Ply: Polyflex with top sanded surface.
4.
Mid Ply: Polybond with top sanded surface.
5.
Mid Ply: Polyglass APP Base.
 
** NOTE TO SPECIFIER ** The following base sheets are optional. Select one of the following base sheet paragraphs and delete those not required.
 
6.
Base Sheet/Mechanically Fastened: Base ply Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
7.
Base Sheet: Polyglass G2 Base.
8.
Base Sheet: Polyglass APP Base
9.
Base Sheet: Elastoflex SA V
10.
Base Sheet: Polyflex with top sanded surface.
11.
Base Sheet: Polybond with top sanded surface
12.
Base Sheet: Polyflex SA Base
13.
Flashing: Same material as roof membrane.
14.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
2.6
HOT MOPPED ROOF SYSTEM
A.
Spec # 200 M I SBS HOT: Hop mopped, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface and a granule-free selvage.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with sand/sand, surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
13.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
B.
Spec # 200 W I SBS HOT: Hop mopped, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface and a granule-free selvage.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastobase or Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
13.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
15.
Cover Board: DensDeck Prime.
16.
Cover Board: Securock Roof Board.
C.
Spec # 300 M I SBS HOT: Hop mopped, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following capsheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase.
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
19.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
20.
Cover Board: DensDeck Prime.
21.
Cover Board: Securock Roof Board.
D.
Spec # 300 W I SBS HOT: Hop mopped, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase.
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
19.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
20.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
21.
Cover Board: DensDeck Prime.
22.
Cover Board: Securock Roof Board.
E.
Spec # 300 C I SBS HOT: Hop mopped, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase.
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
19.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
20.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
21.
Cover Board: DensDeck Prime.
22.
Cover Board: Securock Roof Board.
F.
Spec # 300 W SBS HOT: Hop mopped, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G 3.5mm with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase.
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
19.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
20.
Cover Board: DensDeck Prime.
21.
Cover Board: Securock Roof Board.
G.
Spec # 200 W SBS HOT: Hop mopped, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface and a granule-free selvage.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastobase or Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
13.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
14.
Cover Board: DensDeck Prime.
15.
Cover Board: Securock Roof Board.
H.
Spec # 200 C SBS HOT: Hop mopped, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface and a granule-free selvage.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastobase or Elastobase V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
13.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
14.
Cover Board: DensDeck Prime.
15.
Cover Board: Securock Roof Board.
I.
Spec # 300 C SBS HOT: Hop mopped, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase.
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastobase or Elastoflex V SBS with top and bottom provided with either sand/sand, sand/poly, poly/sand or polyolefin/polyolefin surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
19.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
20.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
21.
Cover Board: DensDeck Prime.
22.
Cover Board: Securock Roof Board.
2.7
COLD ADHESIVE APPLIED ROOFING SYSTEMS
A.
Spec # 200 M I SBS COL: Cold Adhesive applied, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
13.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
15.
Cover Board: DensDeck Prime
16.
Cover Board: Securock Roof Board
B.
Spec # 200 W I SBS COL: Cold Adhesive applied, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
13.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220..
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
15.
Cover Board: DensDeck Prime
16.
Cover Board: Securock Roof Board
C.
Spec # 300 M I SBS COL: Cold Adhesive applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular top surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
5.
Mid Ply: Elastobase
6.
Mid Ply: Elastobase P
7.
Mid Ply: Elastoflex S6
8.
Mid Ply: Elastoflex V
9.
Mid Ply: Elastoshield TS
10.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
11.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
12.
Base Sheet: Polyglass G2 Base.
13.
Base Sheet: Elastobase.
14.
Base Sheet: Elastobase P.
15.
Base Sheet: Elastoflex S6.
16.
Base Sheet: Elastoshield TS
17.
Base Sheet: Elastoshield S6 HT
18.
Flashing: Same material as roof membrane.
19.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
20.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
21.
Cover Board: DensDeck Prime
22.
Cover Board: Securock Roof Board
D.
Spec # 300 W I SBS COL: Cold Adhesive applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
5.
Mid Ply: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastobase.
15.
Base Sheet: Elastobase P.
16.
Base Sheet: Elastoflex S6.
17.
Base Sheet: Elastoshield TS
18.
Base Sheet: Elastoshield S6 HT
19.
Flashing: Same material as roof membrane.
20.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
21.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
22.
Cover Board: DensDeck Prime
23.
Cover Board: Securock Roof Board
E.
Spec # 300 C I SBS COL: Cold Adhesive applied, three ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G SBS with granular surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface.
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following mid ply sheet paragraphs and delete those not required.
 
5.
Mid Ply: Elastoflex S6 SBS with top and bottom provided with sand/sand surfaces.
6.
Mid Ply: Elastobase
7.
Mid Ply: Elastobase P
8.
Mid Ply: Elastoflex S6
9.
Mid Ply: Elastoflex V
10.
Mid Ply: Elastoshield TS
11.
Mid Ply: Elastoshield S6 HT
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
12.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
13.
Base Sheet: Polyglass G2 Base.
14.
Base Sheet: Elastobase.
15.
Base Sheet: Elastobase P.
16.
Base Sheet: Elastoflex S6.
17.
Base Sheet: Elastoshield TS
18.
Base Sheet: Elastoshield S6 HT
19.
Flashing: Same material as roof membrane.
20.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
21.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
22.
Cover Board: DensDeck Prime
23.
Cover Board: Securock Roof Board
F.
Spec # 200 C I SBS COL: Cold Adhesive applied, two ply Polyglass reinforced modified bituminous roofing system for installation over a new or accepted, prepared existing roof substrate.
 
** NOTE TO SPECIFIER ** Select one of the following cap sheet paragraphs and delete those not required.
 
1.
Cap Sheet: Elastoshield TS G with granular top surface.
2.
Cap Sheet: Elastoflex S6 G with granular top surface. Cap Sheet:
3.
Cap Sheet: Elastoflex V G with granular top surface.
4.
Cap Sheet: Elastoshield S6 HT G with granular top surface.
 
** NOTE TO SPECIFIER ** Select one of the following base sheet paragraphs and delete those not required.
 
5.
Base Sheet: Elastoflex V SBS with top and bottom provided with sand/sand surfaces.
6.
Base Sheet: Polyglass G2 Base.
7.
Base Sheet: Elastobase.
8.
Base Sheet: Elastobase P.
9.
Base Sheet: Elastoflex S6.
10.
Base Sheet: Elastoshield TS
11.
Base Sheet: Elastoshield S6 HT
12.
Flashing: Same material as roof membrane.
13.
Insulation: Polytherm; Tapered Polytherm; or Polyglass approved other as specified in Section 07220.
 
** NOTE TO SPECIFIER ** Cover Boards are Optional. If required select one of the following paragraphs and delete those not required.
 
14.
Cover Board: Six Sided Asphalt Impregnated Wood Fiber Board.
15.
Cover Board: DensDeck Prime
16.
Cover Board: Securock Roof Board
 
** NOTE TO SPECIFIER ** Select the membranes required for the Roof Systems specified in the Systems above. Consult the POLYGLASS Technical Services Department for fire rated assembly information. The following code applies to the Product Name designations specified:
S = Smooth, G = Granule, F = Fabric, PE = Polyethylene Film
MAS = Mechanically Attached System, MAS's Require a Base Sheet (Or Other Acceptable Fire Barrier) when seams are welded by open flame equipment.
SA = Self-Adhesive
 
2.8
MODIFIED BITUMINOUS ROOFING MEMBRANE
A.
Membranes with Conventional Technology:
1.
APP (Atactic Polypropylene) Membranes:
a.
Product Name: Polyflex
1)
Surface/Bottom: S / Polyolefin Film
2)
Use: Roofing & Flashing
3)
Install. Method: Torch
4)
Thickness (Nominal): 4.0 mm; 160 mils.
5)
Weight (Approx): 110 Ibs
6)
Length: 32 feet 10 inches
7)
Width: 39-3/8 inches'
8)
Roll Covers: 100 sf.
9)
UL/FM Classified
10)
ASTM: D 6222 Type I; ASTM D 6222 Type II
b.
Product Name: Polyflex G; Polyflex G FR
1)
Surface/Bottom: G / Polyolefin Film
2)
Use: Roofing & Flashing
3)
Install. Method: Torch
4)
Thickness (Nominal): 4.5 mm; 180 mils.
5)
Weight (Approx): 110 Ibs
6)
Length: 32 feet 10 inches
7)
Width: 39-3/8 inches
8)
Roll Covers: 100 sf.
9)
UL/FM Classified
10)
ASTM: D 6222; ASTM D 6222 Type II
c.
Product Name: Polyfresko G; Polyfresko G FR
1)
Reinforced With: Polyester
2)
Surface/ Bottom: Highly Reflective Granule/Polyolefin Film or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Torch
5)
Thickness (Nominal): 4.2 mm; 168 mils
6)
Weight (Approx): 110 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6222 Type I
12)
Solar Reflectance Index (SRI): 96
d.
Product Name: Polybond
1)
Surface/Bottom: G / Polyolefin Film
2)
Use: Roofing Flashing & Walkways
3)
Install. Method: Torch
4)
Thickness (Nominal): 3.5 mm; 140 mils.
5)
Weight (Approx): 90 Ibs
6)
Length: 32 feet 10 inches
7)
Width: 39-3/8 inches
8)
Roll Covers: 100 sf.
9)
UL/FM Classified
10)
ASTM: D 6222 Type I.
e.
Product Name: Polybond G; Polybond G FR
1)
Surface/Bottom: G / Polyolefin Film
2)
Use: Roofing
3)
Flashing & Walkways
4)
Install. Method: Torch
5)
Thickness (Nominal): 4.0 mm; 160 mils
6)
Weight (Approx): 103 Ibs
7)
Length: 32 feet 10 inches
8)
Width: 3 feet 3-3/8 inches
9)
Roll Covers: 100 sf.
10)
UL/FM Classified
11)
ASTM: D 6222 Type I.
f.
Product Name: Polyglass APP Base
1)
Surface/Bottom: S / Polyolefin Film
2)
Use: Base Sheet; Interply Sheet
3)
Install. Method: Torch/Mechanically Attached
4)
Thickness (Nominal): 2.0 MM; 80 mils
5)
Weight (Approx): 86 Ibs
6)
Length: 65 feet 8 inches
7)
Width: 39-3/8 inches
8)
Roll Covers: 200 sf.
9)
UL/FM Classified
10)
ASTM: D 6509
2.
SBS (Styrene-Butadiene-Styrene) Membranes
a.
Product Name: Elastoshield S6 HT G; Elastoshield S6 HT G FR
1)
Reinforced With: High strength combination fiberglass and polyester mat.
2)
Surface/Bottom: G/Polyolefin Film or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop/Film backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): Mop, 3.5mm; 140 mils; Torch: 4.5 mm; 180 mils
6)
Weight (Approx): Mop; 90 lbs; Torch; 114 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6162 Type III
b.
Product Name: Elastoshield S6 HT
1)
Reinforced With: High strength combination fiberglass and polyester mat.
2)
Surface/Bottom: Polyolefin Film or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop/Film backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): Mop, 3.5mm; 140 mils; Torch: 4.5mm; 180 mils
6)
Weight (Approx): Mop; 90 lbs; Torch; 114 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
ASTM Type: ASTM D 6162 Type III
c.
Product Name: Elastoshield TS
1)
Reinforced With: Polyester
2)
Surface/ Bottom: Polyolefin Film Or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop / Film Backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): 4.0 mm; 160 mils
6)
Weight (Approx): 105 102 lbs
7)
Length: 32 feet 8 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I; ASTM D 6164 Type II
d.
Product Name: Elastoshield TS G; Elastoshield TS G FR
1)
Reinforced With: Polyester
2)
Surface/ Bottom: G/Polyolefin Film Or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop / Film Backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): 4.5 mm; 180 mils
6)
Weight (Approx): 108 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I; ASTM D 6164 Type II
e.
Product Name: Elastoflex S6
1)
Reinforced With: Polyester
2)
Surface/ Bottom: Sand/Sand
3)
Uses: Base/Ply Sheet
4)
Install Method: Mop / Film Backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): 3.0 mm; 120 mils/ 2.2 mm; 90 mils
6)
Weight (Approx): 80 lbs / 94 lbs
7)
Length: 32 feet 10 inches / 49 feet 3 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf / 150 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I; ASTM D 6164 Type II
f.
Product Name: Elastoflex S6 G; Elastoflex S6 G FR
1)
Reinforced With: Polyester
2)
Surface/ Bottom: G/Polyolefin Film or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop / Film Backed Torch Grade/Cold Adhesive
5)
Thickness (Nominal): 3.5 mm; 140 mils / 4.0 mm; 160 mils
6)
Weight (Approx): 85 lbs / 102 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I; ASTM D 6164 Type II
g.
Product Name: Polyfresko G SBS; Polyfresko G SBS FR
1)
Reinforced With: Polyester
2)
Surface/ Bottom: Highly Reflective Granule/Polyolefin Film or Sand
3)
Uses: Roofing Flashing & Walkways
4)
Install Method: Mop / Film Backed Torch Grade/Cold Adhesive
5)
5Thickness (Nominal): 4.2 mm; 168 mils
6)
Weight (Approx): 110 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I; ASTM D 6164 Type II
12)
Solar Reflectance Index (SRI): 96
h.
Product Name: Elastoflex V
1)
Reinforced With: Glass
2)
Surface/ Bottom: Sand/Sand; Sand/Poly; Poly/Sand; Poly/Poly
3)
Uses: Base/Ply Sheet
4)
Install Method: Sand Backed, Mop, Film Backed Torch Applied,Cold Adhesive
5)
Thickness (Nominal): 2.2 mm; 90 mils / 3.0 mm; 120 mils
6)
Weight (Approx): 80 lbs / 85 lbs
7)
Length: 49 feet 3 2 inches / 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 150 sf / 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6163 Type I
i.
Product Name: Elastobase P
1)
Reinforced With: Polyester
2)
Surface/ Bottom: Sand/Sand; Sand/Poly; Poly/Sand; Poly/Poly
3)
Uses: Base/Ply Sheet
4)
Install Method: Sand Backed Mop/ Film Backed Torch Applied/Cold Adhesive
5)
Thickness (Nominal): 2.0 mm; 80 mils
6)
Weight (Approx): 94 lbs
7)
Length: 65 feet 8 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 200 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I
j.
Product Name: Elastobase
1)
Reinforced With: Glass
2)
Surface/ Bottom: Sand/Sand;Poly/Sand; Sand/Poly; Poly/Poly
3)
Uses: Base Sheet/Ply Sheet
4)
Install Method: Sand Backed Mop/ Film Backed Torch Applied/ Cold Adhesive
5)
Thickness (Nominal): 2.0 mm; 80 mils
6)
Weight (Approx): 96 lbs
7)
Length: 65 feet 8 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 200 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6163
k.
Product Name: Polyglass G2 Base
1)
Reinforced With: Glass
2)
Surface/ Bottom: Sand/Sand
3)
Uses: Base Sheet/Ply Sheet
4)
Install Method: Sand Backed Mop/Cold Applied
5)
Thickness (Nominal): 1.14 mm
6)
Weight (Approx): 82 lbs
7)
Length: 99 feet 6 2 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 300 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 4601
l.
Product Name: Polyglass Ply VI
1)
Reinforced With: Glass
2)
Surface/Bottom: Sand/Sand
3)
Uses: Ply Sheet
4)
Install Method: Hot Mopped
5)
Thickness: N/A
6)
Weight (Approx): 48 lbs
7)
Length: 162 feet 2 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 500 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 2178 Type VI
m.
Product Name: Polyglass Ply IV
1)
Reinforced With: Glass
2)
Surface/Bottom: Sand/Sand
3)
Uses: Ply Sheet
4)
Install Method: Hot Mopped
5)
Thickness: N/A
6)
Weight (Approx): 44 lbs
7)
Length: 162 feet 2 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 500 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 2178 Type IV
n.
Product Name: PolyAnchor
1)
Reinforced With: Heavyweight polymer fabric
2)
Surface/Bottom: Skid resistant
3)
Uses: Synthetic anchor membrane for both light commercial and residential use. Specifically designed to be used as an anchor sheet in low and steep slope application under Polyglass self-adhered membranes.
4)
Install Method: Mechanical fasteners appropriate for substrate.
5)
Thickness: N/A
6)
Weight (Approx): 34 lbs.
7)
Length: 250 feet
8)
Width: 48 inches
9)
Roll Covers (Approx): 1000 sf
10)
UL Classified
11)
ICC ESR-2018
12)
Miami Dade Code Compliance
B.
SA Self-Adhesive membranes with ADESO Technology
1.
APP (Atactic Polypropylene)
a.
Product Name: Polyflex SA P; Polyflex SA P FR
1)
Reinforced with Polyester
2)
Install Method: SA
3)
Surface/ Bottom: Granule/Split Release Film
4)
Uses: Roofing & Flashing Membrane
5)
Install Method: SA
6)
Thickness (Nominal): 3.5 mm; 140 mils
7)
Weight (Nominal): 90 lbs
8)
Length: 32 feet 10 inches
9)
Width: 3 feet 3-3/8 inches
10)
Roll Covers: 100 sf
11)
UL/FM Classified
12)
ASTM Type: ASTM 6222 Type I / ASTM D1970
b.
Product Name: Polyfresko G SA; Polyfresko G SA FR
1)
Reinforced With Polyester
2)
Surface/Bottom; Highly Reflective G/Split Release Film
3)
Uses: Roofing & Flashing Membrane
4)
Install Method: SA
5)
Thickness (Nominal): 3.5 mm; 140 mils
6)
Weight (Approx): 90 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
UL/FM Classified
10)
Roll Covers: 100 sf
11)
ASTM Type: ASTM D 6222 Type I; ASTM D 1970
12)
Solar Refectance Index (SRI): 96
c.
Product Name: Polyflex SA Base
1)
Reinforced with Fiberglass
2)
Surface/Bottom Mineral Surface/Split Release Film
3)
Uses: Base Sheet/Ply Sheet
4)
Install Method: SA
5)
Thickness (Nominal): 1.5mm; 60 mils
6)
Weight (Approx): 70 lbs
7)
Length: 65 feet 8 Inches
8)
Width: 39-3/8 inches
9)
UL/FM Classified
10)
Roll Covers: 100 sf
11)
ASTM Type: ASTM D 1970
2.
SBS (Styrene-Butadiene-Styrene)
a.
Product Name: Elastoflex SA P; Elastoflex SA P FR
1)
Reinforced With: Polyester
2)
Surface/ Bottom: G/Split Release Film
3)
Uses: Roofing & Flashing membrane
4)
Install Method: SA
5)
Thickness (Nominal): 3.5 mm
6)
Weight (Approx): 95 lbs
7)
Length: 32 feet 10 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 100 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6164 Type I / ASTM D1970
b.
Product Name: Elastoflex SA V Elastoflex SA V FR
1)
Reinforced With: Glass
2)
Surface/ Bottom: Polyolefin Film /Split Release Film
3)
Uses: Base/Ply Sheet
4)
Install Method: SA
5)
Thickness (Approx): 2.0 mm
6)
Weight (Nominal): 98 lbs
7)
Length: 65 feet 8 inches
8)
Width: 39-3/8 inches
9)
Roll Covers: 200 sf
10)
UL/FM Classified
11)
ASTM Type: ASTM D 6163 / ASTM D1970
 
** NOTE TO SPECIFIER ** Include the following paragraph and select the cap sheet color required for granulated cap sheet. Delete if not required.
 
C.
Colors for Granulated Cap Sheet
1.
Buff
2.
Black
3.
White
4.
Highly Reflective White (Polyfresko Cap Sheets)
 
** NOTE TO SPECIFIER ** Coordinate flashing details and materials with Polyglass "Specifications and Details" manual. Contact the manufacturer for additional information.
 
2.9
FLASHING MEMBRANE
A.
Metal Flashing conditions: Provide minimum 9 inch wide base/interply stripping sheets.
B.
Roof to Wall Flashings: Use a minimum of 1 ply of base/interply as reinforcement and cap sheet for all flashing systems.
 
** NOTE TO SPECIFIER ** Select surface coatings if required for the roof system specified. Contact the manufacturer for additional information.
 
2.10
SURFACE COATINGS
 
** NOTE TO SPECIFIER ** Where required, and as specified, POLYGLASS approved coatings may be applied to POLYGLASS Roofing systems in strict conformance with the specific manufacturer's recommended procedures. Coatings may be required to meet necessary code approvals. Please consult the POLYGLASS(R) Technical Services Department for fire rated assembly information.
 
A.
Surface Coating:
1.
Polyglass PG600
2.
Polyglass PG650
3.
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating.
4.
Polyplus 65 Premium Fibered Aluminum Roof Coating.
5.
Polybrite 70 Premium Grade Elastomeric Roof Coating.
6.
PG 700 White Elastomeric Roof Coating.
7.
Polyglass Polybrite 95 Silicone Roof Coating.
8.
Polyglass Polybrite 90 High Solids Silicone Roof Coating.
2.11
FASTENERS
A.
Fasteners and Plates: Provide FM Approved fasteners and plates and other devices as required to suit the system specified.
B.
Wood: Roofing nails of galvanized or stainless steel, of length to penetrate the wood by at least 3/4 inch (19 mm) on flashings and parapet walls.
C.
Masonry: Nail-in expansion type device with zinc body, plated steel nail, and mushroom head or approved equal and of length to embed into the masonry a minimum of 1 inch (25 mm).
D.
Insulation: Mechanical fasteners for securing of insulation to decking shall be approved by the insulation manufacturer for the system specified and shall be FM Approved and be in compliance with Appendix "E" of FM 4470 for corrosion resistance.
1.
Use the same brand fastener throughout the work.
2.
Provide the number of fasteners and layout as recommended by the manufacturer and per FM Approvals and/or RoofNav for wind uplift resistance.
3.
Determine length of fastener by the thickness of the decking and any fill and the thickness of the insulation. Fasteners shall be of sufficient length to achieve a minimum of 1 inch penetration.
E.
Pre-Assembled Fastener/Plate Combination: Case hardened carbon steel and use specific head, shank and thread diameters, point types and head styles meeting building code and FM approvals for corrosion and simulated wind uplift criteria requirements.
1.
Fasteners are designed for the attachment of insulation and membrane to steel (18-24 gauge), wood, and structural concrete.
2.
Provide to meet FM requirements, fastener shall penetrate the steel deck 3/4 inch (19 mm). Minimum penetration is 1 inch (25 mm) in wood, 3/4 inch (19 mm) through wood that is less than 3/4 inch (19 mm) thick and 1-1/4 inches (32 mm) in concrete.
2.12
PRIMER
A.
Asphalt Primer: Polyglass PG100 Asphalt Primer conforming to ASTM D 41.
1.
Primer shall be applied on all dissimilar materials except insulation.
2.
Description: General purpose penetrating asphalt primer used to promote adhesion prior to the application of hot-mopped, cold-applied, and self-adhesive membrane systems as well as roof cements, mastics, and asphalt-based adhesives.
B.
Water-Based Acrylic Primer: Polyglass WB-3000 Water-Based Acryic Primer
1.
Description: Low-VOC water-based acrylic primer that enhances the adhesion of self-adhered roof membranes to a variety of porous and non-porous substrates.
2.13
ASPHALT
A.
Asphalt shall be certified in full compliance with the requirements of Type III or IV asphalt listed in Table 1, ASTM D-312. Each container, or bulk, shipping ticket shall indicate the equiviscous temperature (EVT), the finished blowing temperature (FBT), and the flash point.
2.14
MISCELLANEOUS
A.
Adhesive/Sealant:
1.
Polyglass PG 500 Modified Cement. Meets or exceeds the requirements of ASTM D 4586 Asphalt Roof Cement Type I.
2.
Polyglass PolyPlus 50 Premium MB Flashing Cement. Meets or exceeds the requirements of ASTM D 4586 Asphalt Roof Cement Type I.
3.
Polyglass PolyPlus 35 or PG 350 Modified Adhesive. Meets or exceeds the requirements of ASTM D 3019 Type III Lap Adhesion.
 
** NOTE TO SPECIFIER ** Consult POLYGLASS Technical Services for current information regarding the acceptability of insulation for specific roofing membranes types or manufacturers. Acceptable insulations types include: perlite, polyisocyanurate (ISO), ISO/perlite composite, expanded polystyrene (EPS)/perlite composite, wood fiber, wood Fiber/ISO composite, glass fiber and cellular glass ("FoamGlass"). Contact POLYGLASS for insulations not listed here.
 
B.
Roofing Insulation: Provide roof insulation as specified in Section 07220.
PART 3 EXECUTION
 
3.1
EXAMINATION
A.
Do not begin installation until substrates have been properly prepared.
B.
Inspect and approve the deck condition, slopes and fastener backing if applicable, parapet walls, expansion joints, roof drains, stack vents, vent outlets, nailers and surfaces and elements.
C.
Verify that work penetrating the roof deck, or which may otherwise affect the roofing, has been properly completed.
D.
If substrate preparation and other conditions are the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
** NOTE TO SPECIFIER ** The Architect must verify the structural capability and integrity of the roof deck system and for the proper design relationship among other building components for compatibility with the roof system specified and with the applicable code. All deck surfaces shall be constructed in a manner which will permits a positive slope to drain. A minimum roof slope of 1/4 inch is recommended to maximize long-term performance of the roof system. Drains shall be of sufficient number and size, and located so as to provide satisfactory and rapid drainage of the entire roof surface within 24 to 48 hours of precipitation.
 
3.2
PREPARATION
A.
General: Clean surfaces thoroughly prior to installation.
1.
Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
2.
Fill substrate surface voids that are greater than 1/4 inch wide with an acceptable fill material.
3.
Roof surface to receive roofing system shall be smooth, clean, free from loose gravel, dirt and debris, dry and structurally sound.
4.
Wherever necessary, all surfaces to receive roofing materials shall be power broomed and vacuumed to remove debris and loose matter prior to starting work.
5.
Do not apply roofing during inclement weather. Do not apply roofing membrane to damp, frozen, dirty, or dusty surfaces.
 
** NOTE TO SPECIFIER ** Verify the pull-out capability by the applicable code and modify the following if required. If in doubt, contact the manufacturer's Technical Services Department.
 
6.
Fasteners and plates for fastening components mechanically to the substrate shall provide a minimum pull-out capacity of 300 lb. per fastener. Base or ply sheets attached with cap nails require a minimum pullout capacity of 40 lb. per nail.
7.
Prime decks where required, in accordance with requirements and recommendations of the primer and deck manufacturer.
 
** NOTE TO SPECIFIER ** Edit the following paragraphs as required. Include the surfaces to which the roofing will be applied and delete those not required. Contact the manufacturer's Technical Services Department for surfaces not listed.
 
B.
Metal Deck: Metal deck shall be installed as specified in Section 05300. Comply with the current requirements of FM Approvals in constructing and attaching the decking.
1.
Fastening of the deck should comply with the anticipated live and dead loads pertaining to the building as well as applicable Code.
2.
Steel decks shall be minimum 22-gauge factory galvanized or zinc alloy coated for protection against corrosion.
3.
Suitable FM Approvals Class1 insulation shall be mechanically attached as recommended by the insulation manufacturer.
C.
Wood Deck:
1.
Dimensional wood deck shall be minimum 1 inch thick, knotholes and cracks larger than 1/4 inch shall be covered with sheet metal. All boards shall be appropriately nailed and have adequate end bearing to the centers of beams/rafters.
2.
Plywood shall be a minimum 15/32 inch thick and conform to the standards and installation requirements of the American Plywood Association (APA).
3.
If no roof insulation is specified, provide a suitable dry sheathing paper, followed by a Polyglass approved base sheet nailed appropriately for the specified roof system, with 1 inch diameter caps and annular nails unless otherwise required by the applicable Code or Approval agency.
4.
Insulation is to be mechanically attached in accordance with the insulation manufacturer's recommendations and FM Approvals requirements unless otherwise required by the applicable Code.
D.
Precast concrete:
1.
Decks shall be clean, dry, fully cured and free of flaws and attached securely to the supporting structure as recommended by the deck manufacturer.
2.
All joints shall be caulked or grouted.
3.
Concrete surfaces to receive Polyglass roofing shall be fully primed at the rate of 1 gallon per 100 sq. ft.
4.
Deck joints shall be stripped in with a 12 inch wide strip of modified membrane unadhered a minimum of 2 inches immediately on either side of the joint.
E.
Lightweight insulating concrete:
1.
Deck surfaces shall be smooth, dry, clean and free of ice/frost, projections and depressions.
2.
Install Polyglass base sheet appropriate for the specific roof membrane system with suitable approved lightweight fasteners
F.
Poured reinforced concrete
1.
Shall be smooth, dry, clean and free of ice/frost, projections and depressions. Concrete shall be fully cured and the surface shall be broom cleaned and free of release/curing agents prior to commencement of work.
2.
Prepared concrete surfaces shall be primed with PG 100 ASTM Type D41 asphalt primer at a rate of approx. 1 gallon/100 sq. ft. All primed areas shall be fully dried before proceeding with the application of the roof system.
 
** NOTE TO SPECIFIER ** Edit the following two paragraphs as required. Contact Polyglass for recommendations in any situation, which involves other deck types for new or unusual deck construction.
 
G.
Other deck types:
H.
Re-Roofing Applications:
1.
Remove existing roof flashings from curbs and parapet walls down to the surface of the roof. Remove existing flashings at roof drains and roof penetrations.
2.
Remove all wet, deteriorated, blistered or delaminated roofing membrane or insulation and fill in any low spots occurring as a result of removal work to create a smooth, even surface for application of new roof membranes.
3.
Install new wood nailers as necessary to accommodate insulation/recovery board or new nailing patterns.
4.
When mechanically attached, the fastening pattern for the insulation/recovery board shall be as recommended by the specific product manufacturer.
5.
Re-roofing over coal tar pitch requires a mechanically attached recovery board or insulation and a base sheet prior to the application of Polyglass roofing system.
6.
Existing roof surfaces shall be primed as necessary with asphalt primer meeting ASTM D 41 and allowed to dry prior to installing the Polyglass roofing system.
I.
Insulation:
1.
All joints between layers should be staggered when multiple layers of insulation are installed. Insulation greater than 2.5 inches shall be installed in multiple layers.
2.
Insulation shall be kept dry at all times. Install only as much insulation as can be covered with completed roofing membrane before the end of the day's work or prior to onset of inclement weather.
3.
Edges shall butt tightly and all cuts shall fit neatly against adjoining surfaces to provide a smooth overall surface. Gaps of greater than 1/4 inch width shall be filled with insulation.
4.
Install tapered insulation around roof drains and penetrations to provide adequate slope for proper drainage.
5.
Mechanically attached insulation shall be fastened in accordance with FM Approvals requirements for the applicable geographic zone with the required number and type of fasteners and plates. Exception: where Polyglass requirements are more stringent than FM Approvals or third party manufacturers, Polyglass requirements shall be followed unless otherwise required by the applicable Code or Approval agency.
6.
When asphalt or cold adhesive attachment is specified, the proposed insulation shall be compatible with the roof substrate, the proposed bitumen and the requirements of the specific Polyglass membrane.
7.
Hot asphalt application:
a.
Maximum 4 foot by 4 foot insulation boards shall be attached with hot asphalt.
b.
Asphalt for insulation attachment shall meet ASTM D 312 Type III or IV criteria, as dictated by the roof slope or other design conditions.
c.
Expanded polystyrene (EPS) materials shall not be installed with hot bitumen products.
3.3
INSTALLATION
A.
Install modified bitumen membranes and flashings in accordance with manufacturer's instructions and with the recommendations provided by the National Roofing Contractors Association's Roofing & Waterproofing Manual, the Asphalt Roofing Manufacturers Association, and applicable codes.
B.
General: Do not installing modified bitumen membranes at temperatures lower than 40-45 degrees F wherever practicable. Where work is unavoidable at such temperatures the following precautions be taken:
1.
Take extra care during cold weather installation at ambient temperatures of 40-45 degrees F or below and when ambient temperatures are affected by wind or humidity, to ensure adequate bonding is achieved between the surfaces to be joined. This applies to both material seam welds and adhesion of the applied product to the appropriately prepared substrate as the substrate can be affected by such temperature constraints as well.
2.
In addition, unrolling of cold materials, under very low ambient conditions must be avoided to prevent the likelihood of unnecessary stress cracking. Rolls must be at least 40 degrees F at the time of application. Should the membrane roll become stiff or difficult to install, it should be replaced with a new roll from the heated storage area.
C.
Commence installation of the roofing system at the lowest point of the roof (or roof area), working up the slope toward the highest point. Lap sheets shingle fashion so as to constantly shed water
D.
Base and Ply Sheet Installation:
1.
Install in a manner approved for the specific product, e.g. fully adhered as self-adhered or with asphalt adhesive, torch applied or mechanically attached.
2.
Base or Inter-ply side laps are to be 3 inch minimum and usually delineated by a "lay line" for mopped, torch or mechanically attached application. End laps are typically 6 inches in all cases.
 
** NOTE TO SPECIFIER ** Edit the following three paragraphs as required to include the installation type required for the roofing materials specified.
 
E.
Self-Adhered Application: Base or ply sheet shall be installed per Polyglass specifications and installation guidelines appropriate for the specific substrate type and thickness.
F.
Torch Application: The use of shielded "Dragon-wagons", or moveable, flame-resistant wind shields are recommended to keep all surfaces and materials at a suitably warm temperature during torch application.
G.
Mop Application: Asphalt handling equipment should be insulated in order to minimize the drop in asphalt temperature.
1.
Asphalt must be at least 400 degrees F with a target temperature of 425 degrees F or 20 degrees F above the EVT (equiviscous temperature), whichever is higher, at the point of application.
2.
If minimum asphalt temperature of 400 degrees F cannot be maintained at the point of application, work should be discontinued.
3.
Do not overheat asphalt to compensate for cold weather conditions.
4.
Mopping should not progress more than 4 feet in front of the roll at any time.
H.
Cold Adhesive Application: Install base, ply and cap sheet with Polyglass Polyplus 35 or PG 350 Modified Bitumen Adhesive in accordance with Polyglass specifications and installation guidelines.
I.
Fibrous Cant Strips: Provide non-combustible perlite or glass fiber cant strips at all wall/curb detail treatments where angle changes are greater than 45 degrees. Cant may be set in approved cold adhesives, hot asphalt or mechanically attached with approved plates and fasteners.
J.
Wood Blocking, Nailers and Cant Strips: Provide wood blocking, nailers and cant strips as specified in Section 06114.
1.
Provide nailers at all roof perimeters and penetrations for fastening membrane flashings and sheet metal components.
2.
Wood nailers should match the height of any insulation, providing a smooth and even transition between flashing and insulation areas.
3.
Nailer lengths should be spaced with a minimum 1/8 inch gap for expansion and contraction between each length or change of direction.
4.
Nailers and flashings should be fastened in accordance with Factory Mutual "Loss Prevention Data Sheet 1- 49, Perimeter Flashing" and be designed to be capable of resisting a minimum force of 200 lbs/lineal foot in any direction.
K.
Metal Work: Provide metal flashings, counter flashings, parapet coping caps and thru-wall flashings as specified in Section 07620 or Section 07710. Install in accordance with the SMACNA "Architectural Sheet Metal Manual" or the NRCA Roofing Waterproofing manual.
L.
Termination Bar: Provide a metal termination bar or approved top edge securement at the terminus of all flashing sheets at walls and curbs. Fasten the bar a minimum of 8 inches o/c to achieve constant compression. Provide suitable, sealant at the top edge if required.
 
** NOTE TO SPECIFIER ** Coordinate flashing details with Polyglass "Specifications and Details" manual. Contact the manufacturer for additional information.
 
M.
Flashing: Use Polyglass flashing sheets and minimum 6 inch wide Polyglass stripping sheets. Install stripping sheet with a minimum of 3 inches in both horizontal and vertical surfaces. Install flashing sheets with a minimum of 6 inches on horizontal surface and extended a minimum of 12 inches above finished roof surface.
1.
Install flashing sheets by the same application method used for the roof membranes. In hot mop applications the flashing sheets may be installed by heat weld application provided the proper flashing materials are utilized.
2.
Heat and scrape granules when welding or adhering at cut areas and seams to granular surfaces at all flashings.
3.
Secure the top edge of the flashing sheet using a termination bar only when the wall surface above is waterproofed, or nailed 4 inches on center and covered with an acceptable counter flashing.
4.
Items related to re-roofing operations such as sheet metal gravel stops, roof vents, and similar items shall be incorporated into the new roof system in accordance with the recommendations described in the current issue of the POLYGLASS "Specifications and Details" manual.
N.
Roof Walkways: Walkways shall consist of an additional layer of similar Polyglass membrane of contrasting color granule surface. Provide walkways in areas indicated on the Drawings.
O.
Surface Coatings: Apply roof coatings in strict conformance with the specific manufacturer's recommended procedures.
P.
Provide any corrections to bring the roofing installation into conformance with Polyglass USA, Inc. requirements.
 
** NOTE TO SPECIFIER ** Include the following Field Quality Control paragraphs if a roofing systems warranty is required for the project.
 
3.4
FIELD QUALITY CONTROL
A.
Inspection: Manufacturer shall conduct field observations as deemed necessary by Polyglass for projects requiring Polyglass Roofing Systems Warranty. The number and frequency of field observations shall be as required by Polyglass USA, Inc. Technical Services Department.
B.
Contractor shall correct any deficiencies observed by Polyglass Technical Services to bring the roofing installation into specification conformance with Polyglass USA, Inc. warranty requirements.
3.5
CLEANING
A.
Clean-up and remove daily from the site all wrappings, empty containers, paper, loose particles and other debris resulting from these operations.
B.
Remove asphalt markings from finished surfaces.
C.
Repair or replace defaced or disfigured finishes caused by Work of this section.
3.6
PROTECTION
A.
Provide traffic ways, erect barriers, fences, guards, rails, enclosures, chutes and the like to protect personnel, roofs and structures, vehicles and utilities.
B.
Protect exposed surfaces of finished walls with tarps to prevent damage.
C.
Plywood for traffic ways required for material movement over existing roofs shall be not less than 5/8 inch (16 mm) thick.
D.
In addition to the plywood listed above, an underlayment of minimum 1/2 inch (13 mm) recover board is required on new roofing.
E.
Special permission shall be obtained from the Manufacturer before any traffic shall be permitted over new roofing.
END OF SECTION