MasterFormat: 95
SpecWizard: customize this spec    Download this Overhead Coiling Doors Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Overhead Door Corporation Overhead Coiling Doors
 
         
SECTION 08330
 
         
OVERHEAD COILING DOORS
 
         
Copyright 2006 - 2012 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Overhead Door Corporation; overhead coiling door products.
.
This section is based on the products of Overhead Door Corporation, which is located at:
2501 S. State Highway 121 Bus. Suite 200
Lewisville, TX 75067
Toll Free Tel: 800-929-3667
Tel: 469-549-7100
Email: request info
Web: www.overheaddoor.com
[Click Here ] for additional information.

Overhead Door Corporation pioneered the upward-acting door industry, inventing the first upward-acting door in 1921 and the first electric door opener in 1926. Today, we continue to be the industry leader through the strength of our product innovation, superior craftsmanship and outstanding customer support, underscoring a legacy of quality, expertise and integrity. That's why design and construction professionals specify Overhead Door Corporation products more often than any other brand.

The section includes Overhead Door Corporation's rolling service door product line ensures that your project specifications will be met with ease and style. Ideal for situations where sideroom and headroom are at a premium, our upward-coiling service doors fit openings up to 1500 SF and are available with the industry's widest array of slat profiles, curtain materials and colors, offering a virtually endless array of options to satisfy both aesthetic considerations and working requirements.

This specification also includes RapidSlat TM advanced rolling service doors that are an extension of the rolling steel product line and provides customers with speed and product longevity. It includes the same general construction as Overhead Door’s rolling steel line with enhancements to provide increased speed, security and durability. These innovations include: Maximum performance and functionality with minimum maintenance requirements; • Two-year or 300,000-cycle limited warranty coverage; Five-year limited warranty on motor.

 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Overhead coiling service doors.
 
          B.Overhead coiling insulated doors.
 
          C.Overhead coiling sheet doors.
 
          D.Advanced Rolling Service Doors.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 05500 - Metal Fabrications: Support framing and framed opening.
 
          B.Section 06200 - Finish Carpentry: Wood jamb and head trim.
 
          C.Section 08710 - Door Hardware: Product Requirements for cylinder core and keys.
 
          D.Section 09900 - Painting: Field applied finish.
 
          E.Section 16130 - Raceway and Boxes: Conduit from electric circuit to door operator and from door operator to control station.
 
          F.Section 16150 - Wiring Connections: Power to disconnect.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ASTM A 653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
 
          B.ASTM A 666 - Standard Specification for Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar.
 
          C.ASTM A 924 - Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process.
 
          D.ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
 
          E.NEMA 250 - Enclosures for Electrical Equipment (1000 Volts Maximum).
 
          F.NEMA MG 1 - Motors and Generators.
 
          1.4DESIGN / PERFORMANCE REQUIREMENTS
          ** NOTE TO SPECIFIER ** Select the door(s) specified from the following four paragraphs and delete those not required. Pressures specified are standard, designs are available for pressures to 75 psf and for operation up to 100,000 cycles. Contact the manufacturer for additional information.
 
          A.Overhead coiling service doors:
          1.Wind Loads: Design door assembly to withstand wind/suction load of 20 psf (958 Pa) without damage to door or assembly components.
          2.Operation: Design door assembly, including operator, to operate for not less than 20,000 cycles.
 
          B.Overhead coiling insulated doors:
          1.Wind Loads: Design door assembly to withstand wind/suction load of 20 psf (958 Pa) without damage to door or assembly components.
          2.Operation: Design door assembly, including operator, to operate for not less than 20,000 cycles.
 
          C.Overhead coiling sheet doors:
          ** NOTE TO SPECIFIER ** Select windload for Series 790 doors only from the following paragraph. Delete if not applicable.
          1.Wind Loads: Design door assembly for Series 790 doors to withstand wind/suction load of 25/37.5 psf (1197/1796 Pa) without damage to door or assembly components.
          2.Operation: Design door assembly, including operator, to operate for not less than 10,000 cycles.
 
          D.Advanced Rolling Service doors:
          ** NOTE TO SPECIFIER ** Miami Dade FBC available on all sizes. Contact manufacturer for additional information.
          1.Windload: Design door assembly to withstand wind/suction load of 20 psf (958 Pa) without damage to door or assembly components. Does not apply to doors with optional wearstrip guides.
          2.Operation: Design door assembly, including operator, to operate for not less than 200,000 cycles.
 
          E.Single-Source Responsibility: Provide doors, tracks, motors, and accessories from one manufacturer for each type of door. Provide secondary components from source acceptable to manufacturer of primary components.
 
          F.Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. acceptable to authority having jurisdiction as suitable for purpose specified.
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Details of construction and fabrication.
          4.Installation instructions.
 
          C.Shop Drawings: Include detailed plans, elevations, details of framing members, anchoring methods, required clearances, hardware, and accessories. Include relationship with adjacent construction.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          D.Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
 
          E.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) long, representing actual product, color, and patterns.
 
          F.Manufacturer's Certificates: Certify products meet or exceed specified requirements.
 
          G.Operation and Maintenance Data: Submit lubrication requirements and frequency, and periodic adjustments required.
 
          1.6QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: Company specializing in performing Work of this section with a minimum of five years experience in the fabrication and installation of security closures.
 
          B.Installer Qualifications: Installer Qualifications: Company specializing in performing Work of this section with minimum three years and approved by manufacturer.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          C.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
          3.Refinish mock-up area as required to produce acceptable work.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging until ready for installation.
 
          B.Protect materials from exposure to moisture. Do not deliver until after wet work is complete and dry.
 
          C.Store materials in a dry, warm, ventilated weathertight location.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          1.9COORDINATION
 
          A.Coordinate Work with other operations and installation of adjacent materials to avoid damage to installed materials.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Overhead Door Corporation, which is located at: 2501 S. State Highway 121 Bus. Suite 200 ; Lewisville, TX 75067; Toll Free Tel: 800-929-3667; Tel: 469-549-7100; Email: request info; Web: www.overheaddoor.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
          2.2OVERHEAD COILING SERVICE DOORS
          ** NOTE TO SPECIFIER ** Overhead Door Corporation 600 Series Light Commercial Service Doors are available up to a standard maximum width of 16 feet and a standard maximum height of 16 feet. Overhead Door Corporation 610 and 620 Series Industrial and Heavy Industrial Service Doors are available up to a standard maximum width of 40 feet and a standard maximum height of 30 feet. Edit as required to suit project requirements.
          ** NOTE TO SPECIFIER ** 600 Series doors are suitable for light commercial, mini warehouse and economy projects.
 
          A.Light Commercial Doors: Overhead Door Corporation, 600 Series Coil-Away Service Doors.
          1.Curtain: Interlocking roll-formed galvanized steel slats, flat crown profile type CAW, 26 gauge for widths up to 12 feet 4 inches (3.75 m), 24 gauge for widths up to 16 feet (4.88 m). End of each slat shall be locked from lateral movement by a staking lock system. (Galvanized alternate malleable end locks.)
          2.Finish:
          a.Curtain slats and hood shall be galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)White polyester.
          b)Brown polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3)Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer.
          3.Weatherseals: Vinyl bottom seal.
          4.Bottom Bar: Extruded aluminum.
          5.Guides: Roll-formed galvanized steel shapes attached to continuous galvanized steel wall angle.
          ** NOTE TO SPECIFIER ** Select one of the following two finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          6.Brackets: Galvanized steel to support counterbalance and curtain.
          7.Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel and supporting the curtain with deflection limited to 0.03 inch per foot of span. Spring tension shall be adjustable.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          8.Hood: Not Required.
          9.Hood: 24 gauge galvanized steel with intermediate supports as required.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          10.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following manual operation paragraphs and delete the ones not required.
          a.Manual push up for doors up to 100 SF.
          b.Chain hoist for doors over 100 SF.
          ** NOTE TO SPECIFIER ** Include the following paragraph is electric motor operation is required and delete if not required.
          11.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)N/A.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close, and stop controls.
          3)Push-button and key operated control stations with open, close, and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          12.Windload Design:
          ** NOTE TO SPECIFIER ** Select the following paragraph or delete if not required. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification.
          a.FBC certification FL#_______.
          13.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Two interior bottom bar slide bolts for manually operated doors.
          b.Exterior slide lock for manually operated mini-warehouse doors.
          c.Chain keeper locks for chain hoist operation.
          d.Interior slide bolt lock for electric operation.
          e.Cylinder lock for electric operation.
          14.Wall Mounting Condition: Face-of-wall.
          ** NOTE TO SPECIFIER ** 610 Series doors are suitable for heavy duty industrial and other similar projects.
 
          B.Industrial Doors: Overhead Door Corporation, 610 Series Service Doors.
          1.Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement.
          ** NOTE TO SPECIFIER ** Select one of the following profile paragraphs as required and delete the ones not required.
          a.Curved profile type C-187 for doors up to 15 feet 4 inches (4.67 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 22 gauge galvanized steel is standard.
          1)24 gauge galvanized steel.
          2)22 gauge galvanized steel.
          3)20 gauge galvanized steel.
          4)18 gauge galvanized steel.
          5)22 gauge stainless steel.
          6)20 gauge stainless steel.
          7)18 gauge aluminum.
          b.Curved profile type C-275 for doors up to and between 15 feet 4 inches (4.67 m) and 18 feet 4 inches (5.59 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 22 gauge galvanized steel is standard.
          1)22 gauge galvanized steel.
          2)20 gauge galvanized steel.
          3)18 gauge galvanized steel.
          4)16 gauge galvanized steel.
          5)22 gauge stainless steel.
          6)20 gauge stainless steel.
          7)16 gauge aluminum.
          c.Curved profile type C-275 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 20 gauge galvanized steel is standard.
          1)20 gauge galvanized steel.
          2)18 gauge galvanized steel.
          3)16 gauge galvanized steel.
          4)20 gauge stainless steel.
          5)14 gauge aluminum.
          d.Curved profile type C-275 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 18 gauge galvanized steel is standard.
          1)18 gauge galvanized steel.
          2)16 gauge galvanized steel.
          3)14 gauge aluminum. Maximum width is 27 feet.
          e.Flat profile type F-265 for doors up to 18 feet 4 inches (5.59 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 22 gauge galvanized steel is standard.
          1)22 gauge galvanized steel.
          2)20 gauge galvanized steel.
          3)18 gauge galvanized steel.
          4)16 gauge galvanized steel.
          5)22 gauge stainless steel.
          6)20 gauge stainless steel.
          7)18 gauge aluminum.
          f.Flat profile type F-265 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 20 gauge galvanized steel is standard.
          1)20 gauge galvanized steel.
          2)18 gauge galvanized steel.
          3)16 gauge galvanized steel.
          4)20 gauge stainless steel.
          5)16 gauge aluminum.
          g.Flat profile type F-265 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 18 gauge galvanized steel is standard.
          1)18 gauge galvanized steel.
          2)16 gauge galvanized steel.
          3)16 gauge aluminum. Maximum width is 27 feet.
          ** NOTE TO SPECIFIER ** Fenestrated and ventilated doors are optional. Select one of the following paragraphs as required and delete the one not required. Delete entirely if not required. Requires curved profile C-275 or flat profile C-265 slat minimum 18 gauge.
          h.For fenestrated service doors, provide slats with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings.
          i.For ventilated service doors, provide slats with 1/16 inch (16 mm) diameter perforations 3/32 inch (2.4 mm) on center staggered rows.
          2.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs for the slat and hood material required and delete the ones not required.
          a.Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester.
          b)Tan polyester.
          c)White polyester.
          d)Brown polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3)Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer.
          b.Stainless Steel: Slats and hood shall be stainless steel finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: 2B mill finish.
          2)Finish: No. 4 satin finish.
          c.Aluminum: Slats and hood shall be aluminum finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: Mill finish.
          2)Finish: Clear anodized finish.
          3)Finish: Bronze anodized finish.
          4)Finish: Powder coat, PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3.Weatherseals:
          a.Vinyl bottom seal.
          ** NOTE TO SPECIFIER ** Guide weatherseals are optional delete if not required.
          b.Guide weatherseal.
          4.Bottom Bar:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the ones not required. Galvanized steel angles are optional for all doors.
          a.Extruded aluminum for doors up to 15 feet 4 inches (4.67 m) wide.
          b.Two primed steel angles for doors over 15 feet 4 inches (4.67 m) wide.
          c.Two galvanized steel angles.
          5.Guides: Roll-formed galvanized steel shapes attached to continuous galvanized steel wall angle.
          ** NOTE TO SPECIFIER ** Select one of the following two finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          6.Brackets:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Hot rolled steel to support counterbalance, curtain and hood.
          b.Galvanized steel to support counterbalance, curtain and hood.
          7.Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel.
          8.Hood:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the ones not required.
          a.24 gauge galvanized steel with intermediate supports as required.
          b.Stainless steel, 24 gauge hood with intermediate supports as required.
          c.Aluminum hood with intermediate supports as required.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          9.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following manual operation paragraphs and delete the ones not required.
          a.Manual push up for doors up to 96 SF.
          b.Chain hoist for doors up to 96 SF.
          c.Chain hoist for doors over 96 SF.
          d.Crank operation.
          ** NOTE TO SPECIFIER ** Include the following paragraph is electric motor operation is required and delete if not required.
          10.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Pneumatic sensing edge.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close, and stop controls.
          3)Push-button and key operated control stations with open, close, and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification and insert below.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL#______.
          12.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Two interior bottom bar slide bolts for manually operated doors.
          b.Chain keeper locks for chain hoist operation.
          c.Interior slide bolt lock for electric operation with interlock switch.
          d.Cylinder lock.
          13.Wall Mounting Condition:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Face-of-wall mounting.
          b.Between jambs mounting.
          ** NOTE TO SPECIFIER ** Vision lites are optional. Select open or covered openings. Delete if not required.
          14.Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings.
          a.Provide open with no cover.
          b.Provide with Plexiglas covers over openings.
          ** NOTE TO SPECIFIER ** 620 Series doors are suitable for heavy duty industrial and other similar projects requiring weatherstripping.
 
          C.Heavy Duty Industrial Doors: Overhead Door Corporation, 620 Series Stormtite Service Doors.
          1.Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement.
          ** NOTE TO SPECIFIER ** Select one of the following profile paragraphs as required and delete the ones not required.
          a.Flat profile type F-265 for doors up to 18 feet 4 inches (5.59 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 22 gauge galvanized steel is standard.
          1)22 gauge galvanized steel.
          2)20 gauge galvanized steel.
          3)18 gauge galvanized steel.
          4)16 gauge galvanized steel.
          5)22 gauge stainless steel.
          6)20 gauge stainless steel.
          7)18 gauge aluminum.
          b.Flat profile type F-265 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 20 gauge galvanized steel is standard.
          1)20 gauge galvanized steel.
          2)18 gauge galvanized steel.
          3)16 gauge galvanized steel.
          4)20 gauge stainless steel.
          5)16 gauge aluminum.
          c.Flat profile type F-265 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 18 gauge galvanized steel is standard.
          1)18 gauge galvanized steel.
          2)16 gauge galvanized steel.
          3)16 gauge aluminum. (Maximum width of 27 feet (8.23 m).
          2.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs for the slat and hood material and finish required and delete the ones not required.
          a.Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester.
          b)Tan polyester.
          c)White polyester.
          d)Brown polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3)Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer.
          b.Stainless Steel: Slats and hood shall be stainless steel finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: 2B mill finish.
          2)Finish: No. 4 satin finish.
          c.Aluminum: Slats and hood shall be aluminum finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: Mill finish.
          2)Finish: Clear anodized finish.
          3)Finish: Bronze anodized finish.
          4)Finish: Powder coat, PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3.Weatherseals:
          a.Vinyl bottom seal, exterior guide and internal hood seals.
          ** NOTE TO SPECIFIER ** Guide and lintel weatherseals are optional delete if not required.
          b.Interior guide weatherseal.
          c.Lintel weatherseal.
          4.Bottom Bar:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the ones not required. Galvanized steel angles are optional for all doors.
          a.Extruded aluminum for doors up to 15 feet 4 inches (4.67 m) wide.
          b.Two primed steel angles for doors over 15 feet 4 inches (4.67 m) wide.
          c.Two galvanized steel angles.
          5.Guides: Roll-formed galvanized steel shapes.
          ** NOTE TO SPECIFIER ** Select one of the following two finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          6.Brackets:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Hot rolled prime painted steel to support counterbalance, curtain and hood.
          b.Galvanized steel to support counterbalance, curtain and hood.
          7.Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel.
          8.Hood: Provide with internal hood baffle weatherseal.
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the ones not required.
          a.24 gauge galvanized steel with intermediate supports as required.
          b.Stainless steel, 24 gauge hood with intermediate supports as required.
          c.Aluminum hood with intermediate supports as required.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          9.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following manual operation paragraphs and delete the ones not required.
          a.Manual push up for doors up to 96 SF.
          b.Chain hoist for doors up to 96 SF.
          c.Chain hoist for doors over 96 SF.
          d.Crank operation.
          ** NOTE TO SPECIFIER ** Include the following paragraph if electric motor operation is required and delete if not required.
          10.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Pneumatic sensing edge.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close, and stop controls.
          3)Push-button and key operated control stations with open, close, and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification and insert below.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL# ___.
          12.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Two interior bottom bar slide bolts for manually operated doors.
          b.Interior bottom bar slide bolt with chain hoist operation.
          c.Chain keeper locks for chain hoist operation.
          d.Interior slide bolt lock for electric operation with interlock switch.
          e.Cylinder lock for electric operation with interlock switch.
          13.Wall Mounting Condition:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Face-of-wall mounting.
          b.Between jambs mounting.
          ** NOTE TO SPECIFIER ** Vision lites are optional. Select open or covered openings. Delete if not required.
          14.Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings.
          a.Provide open with no cover.
          b.Provide with Plexiglas covers over openings.
 
          2.3INSULATED OVERHEAD COILING SERVICE DOORS
 
          A.Overhead Coiling Stormtite Insulated Service Doors: Overhead Door Corporation 625 Series.
          1.Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement.
          a.Flat profile type F-265i for doors up to 40 feet (12.19 m) wide.
          b.Front slat fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 24 gauge galvanized steel is standard.
          1)24 gauge galvanized steel.
          2)22 gauge galvanized steel.
          3)20 gauge galvanized steel.
          4)18 gauge galvanized steel.
          5)22 gauge stainless steel.
          6)20 gauge stainless steel.
          7)Aluminum .040 inch (1 mm).
          c.Back slat fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. 24 gauge galvanized steel is standard.
          1)24 gauge galvanized steel.
          2)24 gauge stainless steel.
          3)Aluminum .024 inch (.06 mm).
          d.Slat cavity filled with CFC-free foamed-in-place, polyurethane insulation.
          1)R-Value: 7.7, U-Value: 0.13.
          2)Sound Rating: STC-21.
          2.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs for the slat and hood material required and delete the ones not required.
          a.Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester.
          b)Tan polyester.
          c)White polyester.
          d)Brown polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3)Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer.
          b.Stainless Steel: Slats and hood shall be stainless steel finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: 2B mill finish.
          2)Finish: No. 4 satin finish.
          c.Aluminum: Slats and hood shall be aluminum finished as follows.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Finish: Mill finish.
          2)Finish: Clear anodized finish.
          3)Finish: Bronze anodized finish.
          4)Finish: Powder coat, PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          3.Weatherseals:
          a.Vinyl bottom seal, exterior guide and internal hood seals.
          ** NOTE TO SPECIFIER ** Guide and lintel weatherseals are optional delete if not required.
          b.Interior guide weatherseal.
          c.Lintel weatherseal.
          4.Bottom Bar:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Two prime painted steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides.
          b.Two galvanized steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides.
          c.Two stainless steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides.
          d.Extruded aluminum angle minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides.
          5.Guides: Three Structural steel angles.
          ** NOTE TO SPECIFIER ** Select one of the following two finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          6.Brackets:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Hot rolled prime painted steel to support counterbalance, curtain and hood.
          b.Galvanized steel to support counterbalance, curtain and hood.
          c.Stainless steel to support counterbalance, curtain and hood.
          7.Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel.
          8.Hood: Provide with internal hood baffle weatherseal.
          ** NOTE TO SPECIFIER ** Select one of the following three paragraphs and delete the ones not required.
          a.24 gauge galvanized steel with intermediate supports as required.
          b.Stainless steel, 24 gauge hood with intermediate supports as required.
          c.Aluminum hood with intermediate supports as required.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          9.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following manual operation paragraphs and delete the ones not required.
          a.Chain hoist.
          b.Crank operation.
          * NOTE TO SPECIFIER ** Include the following paragraph is electric motor operation is required and delete if not required.
          10.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)Pneumatic sensing edge.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close, and stop controls.
          3)Push-button and key operated control stations with open, close, and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification and insert below.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL# ___.
          12.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
          a.Chain keeper locks for chain hoist operation.
          b.Interior slide bolt lock for electric operation with interlock switch.
          c.Cylinder lock for electric operation with interlock switch.
          13.Wall Mounting Condition:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Face-of-wall mounting.
          b.Between jambs mounting.
          ** NOTE TO SPECIFIER ** Vision lites are optional. Select open or covered openings. Delete if not required.
          14.Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings.
          a.Provide with double Plexiglas covers over openings.
          ** NOTE TO SPECIFIER ** Overhead Door Corporation 790CW Series Commercial Winload Doors are available up to a standard maximum width of 20 feet and a standard maximum height of 16 feet. Overhead Door Corporation 780CW Series Commercial Doors are available up to a standard maximum width of 16 feet and a standard maximum height of 16 feet. Overhead Door Corporation 770SS Series Self-Storage Doors are available up to a standard maximum width of 10 feet and a standard maximum height of 10 feet. Select door type required and edit as required to suit project requirements. Delete doors not required.
 
          2.4OVERHEAD COILING SHEET DOORS
 
          A.Overhead Coiling Commercial Windloaded Sheet Doors: Overhead Door Corporation 790 Series.
          1.Curtain: Roll formed, 26 gauge galvanized steel, per ASTM A 653, SQ Grade 80, Galvanized G-30. Sections interlocked and permanently seamed together to form a continuous curtain. Provided with a PVC edge strip stapled on the edge of curtain's exterior side to minimize steel-to-steel contact, enhance door operation, and minimize curtain nesting and scratching. Curtain shall have 9 gauge ductile iron windlocks on each edge of the curtain spaced according to door size and the application's windloading requirements.
          2.Finish:
          a.Curtain slats shall receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          b.Top Coat Color:
          ** NOTE TO SPECIFIER ** Select one of the following color paragraphs and delete the ones not required. Reference manufacturers OHD Color Chart: R900-667.
          1)White.
          2)Glossy White.
          3)Patriot Red.
          4)Garnet Red.
          5)Brick Red.
          6)Royal Blue.
          7)Polar Blue.
          8)Forest Green.
          9)Hunter Green.
          10)Desert Tan.
          11)Buckskin Cream.
          12)Silhouette Grey.
          13)Teal.
          14)Walnut Brown.
          15)Bronze.
          16)Harvest Orange.
          17)Autumn Orange.
          18)As selected by the Architect from the manufacturers standard colors.
          c.Guides, angles, bottom bar stops, headplates and rings galvanized. Aluminum bottom bar clear anodized.
          3.Bottom Bar: Extruded aluminum reinforced with 1-1/2 inch by 2 inch (38 mm by 51 mm) roll formed steel angle and provided with a flexible PVC bulb type astragal to ensure a consistent seal along the floor. Extrusion designed to interlock with door curtain.
          4.Bottom Bar Stops: Bottom bar stops of "quick connect" design that allows the curtain to be inserted into the "universal" guide and lock into place with one fastener. Bottom bar stops shall be 12 gauge.
          5.Guides: Guides roll-formed from 14-gauge grade 50 galvanized steel. Guides 3 inches (76 mm) wide with UHMW polypropylene rub strips on each edge of the guide. Through hole, universal design shall allow easy access from the front of the guide for fastener attachment to the door jamb material. Guides of universal design for use in concrete, wood, steel or masonry jambs Guides pre-punched to accept "quick connect" attachment of the bottom bar stops.
          ** NOTE TO SPECIFIER ** Select one of the following two headplate paragraphs and delete the one not required. Stamped headplate is standard heavy duty headplate is optional.
          6.Headplates: Stamped 11 gauge steel, mounted directly to the wall to support the door shaft and ensure smooth door roll operation.
          7.Heavy Duty Headplates: 0.187 inch (4.76 mm) thick welded steel, mounted directly to the wall to support the door shaft and ensure smooth door roll operation.
          8.Counterbalance: Counterbalance assembly with "stepped" steel rings designed to ensure a tight and uniform curtain wrap. Rings include steel roller bearings for enhanced door operation and cycle life. 3-3/8 inch (86 mm) I.D. springs lubricated at factory to enhance long life and door operation. Shaft 1-5/16 inch (35 mm) diameter to minimize door deflection. Counterbalance assembly design to allow quick assembly of "non-handed" chain hoist on either side of door on the job site.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          9.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          a.Manual push up.
          b.Chain hoist with 6:1 reduced drive.
          ** NOTE TO SPECIFIER ** Include the following paragraph is electric motor operation is required and delete if not required.
          10.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)N/A.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close and stop controls.
          3)Push-button and key operated control stations with open, close and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          11.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. Dual exterior curtain lock is optional.
          a.Standard Interior bottom bar slide bolt on each end of the door's bottom bar assembly.
          b.Optional Dual Exterior curtain locks, 770 series slide bolt lock.
 
          B.Overhead Coiling Commercial Sheet Doors: Overhead Door Corporation 780 Series.
          1.Curtain: Roll formed, 26 gauge galvanized steel, per ASTM A 653 SQ Grade 80, Galvanized G-30. Sections interlocked and permanently seamed together to form a continuous curtain. Provided with a PVC edge strip stapled on the edge of curtain's exterior side to minimize steel-to-steel contact, enhance door operation, and minimize curtain nesting and scratching.
          2.Finish:
          a.Curtain slats shall receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          b.Top Coat Color:
          ** NOTE TO SPECIFIER ** Select one of the following color paragraphs and delete the ones not required. Reference manufacturers OHD Color Chart: R900-667.
          1)White.
          2)Glossy White.
          3)Patriot Red.
          4)Garnet Red.
          5)Brick Red.
          6)Royal Blue.
          7)Polar Blue.
          8)Forest Green.
          9)Hunter Green.
          10)Desert Tan.
          11)Buckskin Cream.
          12)Silhouette Grey.
          13)Teal.
          14)Walnut Brown.
          15)Bronze.
          16)Harvest Orange.
          17)Autumn Orange.
          18)As selected by the Architect from the manufacturers standard colors.
          c.Guides, angles, bottom bar stops, headplates and rings galvanized. Aluminum bottom bar clear anodized.
          3.Bottom Bar: Extruded aluminum reinforced with 1-1/2 inch by 2 inch (38 mm by 51 mm) roll formed steel angle and provided with a flexible PVC bulb type astragal to ensure a consistent seal along the floor. Extrusion designed to interlock with door curtain.
          4.Bottom Bar Stops: Bottom bar stops of "quick connect" design that allows the curtain to be inserted into the "universal" guide and lock into place with one fastener. Bottom bar stops shall be 12 gauge.
          5.Guides: Guides roll-formed from 18-gauge steel. Guides 3 inches (76 mm) wide with UHMW polypropylene rub strips on each edge of the guide. Through hole, universal design shall allow easy access from the front of the guide for fastener attachment to the door jamb material. Guides of universal design for use in concrete, wood, steel or masonry jambs Guides pre-punched to accept "quick connect" attachment of the bottom bar stops.
          ** NOTE TO SPECIFIER ** Select one of the following two headplate paragraphs and delete the one not required. Stamped headplates are standard. Heavy duty headplates are optional.
          6.Headplates: Stamped 11 gauge steel, mounted directly to the wall to support the door shaft and ensure smooth door roll operation.
          7.Heavy Duty Headplates: 0.187 inch (4.76 mm) thick welded steel, mounted directly to the wall to support the door shaft and ensure smooth door roll operation.
          8.Counterbalance: Counterbalance assembly with "stepped" steel rings designed to ensure a tight and uniform curtain wrap. Rings include steel roller bearings for enhanced door operation and cycle life. 3-3/8 inch (86 mm) I.D. springs lubricated at factory to enhance long life and door operation. Shaft 1-5/16 inch (35 mm) diameter to minimize door deflection. Counterbalance assembly design to allow quick assembly of "non-handed" chain hoist on either side of door on the job site.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for manual operation or electric motor operation and delete the one not required.
          9.Manual Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          a.Manual push up.
          b.Chain hoist with 6:1 reduced drive.
          ** NOTE TO SPECIFIER ** Include the following paragraph is electric motor operation is required and delete if not required.
          10.Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
          a.Sensing Edge Protection:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          1)N/A.
          2)Electric sensing edge.
          b.Operator Controls:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Push-button operated control stations with open, close, and stop buttons.
          2)Key operation with open, close, and stop controls.
          3)Push-button and key operated control stations with open, close, and stop buttons.
          ** NOTE TO SPECIFIER ** Select one of the following location paragraphs and delete the one not required.
          4)Controls for interior location.
          5)Controls for exterior location.
          6)Controls for both interior and exterior location.
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          7)Controls surface mounted.
          8)Controls flush mounted.
          c.Special Operation:
          ** NOTE TO SPECIFIER ** Select one of the following operation paragraphs and delete the one not required.
          1)Vehicle detector operation.
          2)Radio control operation.
          3)Card reader control.
          4)Photocell operation.
          5)Door timer operation.
          6)Commercial light package.
          7)Explosion and dust ignition proof control wiring.
          d.Motor Voltage: 115/230 single phase, 60 Hz.
          11.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. Dual exterior curtain lock is optional.
          a.Standard Interior bottom bar slide bolt on each end of the door's bottom bar assembly.
          b.Optional Dual Exterior curtain locks, 770 series slide bolt lock.
 
          C.Overhead Coiling Self Storage Sheet Doors: Overhead Door Corporation 770 Series.
          1.Curtain: Roll formed, 26 gauge galvanized steel, per ASTM A 653 SQ Grade 80, Galvanized G-30. Sections interlocked and permanently seamed together to form a continuous curtain. Provided with a PVC edge strip stapled on the edge of curtain's exterior side to minimize steel-to-steel contact, enhance door operation, and minimize curtain nesting and scratching.
          2.Finish:
          a.Curtain slats shall receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat.
          b.Top Coat Color:
          ** NOTE TO SPECIFIER ** Select one of the following color paragraphs and delete the ones not required. Reference manufacturers OHD Color Chart: R900-667.
          1)White.
          2)Glossy White.
          3)Patriot Red.
          4)Garnet Red.
          5)Brick Red.
          6)Royal Blue.
          7)Polar Blue.
          8)Forest Green.
          9)Hunter Green.
          10)Desert Tan.
          11)Buckskin Cream.
          12)Silhouette Grey.
          13)Teal.
          14)Walnut Brown.
          15)Bronze.
          16)Harvest Orange.
          17)Autumn Orange.
          18)As selected by the Architect from the manufacturers standard colors.
          c.Guides, angles, bottom bar stops, headplates and rings galvanized. Aluminum bottom bar clear anodized.
          3.Bottom Bar: Extruded aluminum reinforced with 1-1/2 inch by 1-1/2 inch (38 mm by 38 mm) roll formed steel angle and provided with a flexible PVC bulb type astragal to ensure a consistent seal along the floor. Extrusion designed to interlock with door curtain.
          4.Bottom Bar Stops: Bottom bar stops shall be of "quick connect" design that allows the curtain to be inserted into the "universal" guide, then locked into place without the use of fasteners. Bottom bar stops shall be 14 gauge.
          5.Guides: Guide roll-formed from 18-gauge steel. Guides 1-5/8 inches (41 mm) wide with UHMW polypropylene rub strips on each edge of the guide. Through hole, universal design shall allow easy access from the front of the guide for fastener attachment to the door jamb material. Guides of universal design for use in concrete, wood, steel or masonry jambs Guides pre-punched to accept "quick connect" attachment of the headplate and bottom bar stops.
          6.Headplates: Headplates of "quick connect" design for quick assembly to the guides. Headplates 14-gauge steel and includes steel roller bearings to prevent steel-to-steel contact for improved door operations and extended door shaft life.
          7.Counterbalance: Counterbalance assembly with “stepped” designed steel rings to ensure a tight and uniform curtain wrap. 3-3/8 inch (86 mm) I.D. springs lubricated at factory to enhance long life and door operation. Shaft 1-5/16 inch (35 mm) diameter with .065 inch (1.65 mm) wall thickness to minimize door deflection
          8.Operation: Manual push up.
          9.Locking:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required. Dual exterior curtain lock is optional.
          a.Standard Interior bottom bar slide bolt on each end of the door's bottom bar assembly.
          b.Optional Dual Exterior curtain locks, 770 series slide bolt lock.
 
          2.5ADVANCED ROLLING SERVICE DOORS
          ** NOTE TO SPECIFIER ** RapidSlat Series 611 Service Doors are designed for exterior and interior openings that require a high-speed, high-cycle door. Available in a maximum height of 20 feet and a maximum width of 20 feet. Standard windload design 20 PSF. Note that windload design does not apply when wear strip guides are used. Windload ratings up to and including Miami-Dade County and/or FBC will be available available Q1 2010. Contact the manufacturer for additional information.
 
          A.RapidSlat Series 611 Service Doors by Overhead Door Corporation.
          1.Curtain: Interlocking roll-formed metal slats as specified with endlocks attached to each end of alternate slats to prevent lateral movement.
          ** NOTE TO SPECIFIER ** Select one of the following profiles and thickness paragraphs; and delete the ones not required.
          a.Curved Profile type C-187 for doors up to 15 feet 4 inches wide shall be fabricated:
          1)22 gauge powder coated steel.
          2)20 gauge powder coated steel.
          3)18 gauge powder coated steel.
          4)22 gauge stainless steel.
          5)20 gauge stainless steel.
          6).040 inch aluminum.
          b.Curved Profile type C-275 for doors up to 20 feet wide shall be fabricated of:
          1)22 gauge powder coated steel.
          2)20 gauge powder coated steel.
          3)18 gauge powder coated steel.
          4)22 gauge stainless steel.
          5)20 gauge stainless steel.
          6).050 inch aluminum.
          c.Flat Profile type F-265 for doors up to 20 feet wide fabricated of:
          1)22 gauge powder coated steel.
          2)20 gauge powder coated steel.
          3)18 gauge powder coated steel.
          4)22 gauge stainless steel.
          5)20 gauge stainless steel.
          6).050 inch aluminum.
          d.For fenestrated service doors, provide slats with 3 inch by 5/8 inch uniformly spaced openings and fabricated of:
          1)18 gauge Curved Profile Type C-275.
          2)18 gauge Flat Profile Type F-265.
          e.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester.
          b)Tan polyester.
          2)Powder coat: PowderGuard
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          a)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          b)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          2.Bottom Bar: Two metal angles, minimum thickness 3/16 inch, bolted back to back to reinforce curtain in the guides and incorporating a 2-wire, self-monitoring, fail safe, electric sensing edge with a yellow/black striped vinyl cover. Angles shall be:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the ones not required.
          a.Primed black painted galvanized steel.
          b.Powder coated steel.
          c.Powder coated extruded aluminum.
          d.Stainless steel.
          3.Guides: Three Structural steel angles.
          ** NOTE TO SPECIFIER ** Select one of the following four finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Premium: Weather resistant polyester powder coat.
          c.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          d.Finish: Stainless steel.
          ** NOTE TOSPECIFIER ** Note that motor HP is dependant on the door size(s) required. Contact manufacturer for HP requirements.
          4.Motor: Direct drive, hypoid gear motor/brake assembly sized for openings. Provide with a manual hand crank for operation during power outages. Operator and drive assembly is factory pre-assembled and provided with low voltage factory wiring with quick connect wiring harnesses where applicable.
          a.Opening Speed: 20 inches per second.
          b.Closing Speed: 12 inches per second.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          c.Electrical Characteristics: 208/230V AC, three phase per motor/drive.
          d.Electrical Characteristics: 460V AC, 3 phase per motor/drive.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          e.Left hand mount.
          f.Right hand mount.
          5.Control Panel: Provide electronic Variable Frequency drive controller with microprocessor self-diagnostics. Two line LCD readout indicates door action, alarm conditions, and fault conditions. Time delay self close timer and non-resettable cycle counter is included. Enclosure is NEMA 4X rated.
          6.Door Roll: Directly driven, springless roll shall be steel tube with integral shafts, keyed on the Drive End and supported by self-aligning greaseable sealed bearings. Door shall not require any counterbalance device.
          7.Hood: Protecting drive motor, barrel, chain, stop lock brake and sprocket from dirt and debris and extending between the support brackets. Fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following hood material paragraphs; and delete the ones not required. Standard hood assembly is 24 gauge black painted steel.
          a.24 gauge black painted steel.
          b.24 gauge powder coated steel.
          c.Stainless Steel with brush finish.
          d.Powder coated aluminum.
          ** NOTE TO SPECIFIER ** Select the following paragraph for exterior mounted doors; and delete if not required.
          e.Provide with sloped top for exterior mounting.
          8.Brackets: Provide metal brackets to support motor, curtain, and hood and fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following bracket material paragraphs; and delete the ones not required. Standard is black painted steel.
          a.Black painted steel.
          b.Powder coated aluminum.
          c.Stainless Steel.
          9.Safety Devices: Provide door with following safety devices:
          a.Photoelectric sensors that cast an invisible beam across the door opening and reverses the downward motion of the door when an object enters the path of the beam.
          b.Self-monitoring 2-wire, black/yellow striped electric fail-safe sensing edge reverses downward motion upon impact.
          c.Automatic stop lock brake eliminates uncontrolled curtain travel independent of other safeties.
          10.Actuators:
          a.One Open/Close/Stop push button station incorporated into Control Panel.
          ** NOTE TO SPECIFIER ** Complete the following paragraph for optional equipment as required; and delete if not required. Specify optional push buttons, loop detectors, radio control, motion detectors, or any combination thereof as required. Considerable thought should be given to the choice of actuators based on the type of traffic and traffic flow through the opening. Contact the manufacturer for additional information.
          b.Loop detectors.
          c.Radio control.
          d.Push buttons.
          e.Motion detectors.
          f.Pull cords.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL# ___.
          ** NOTE TO SPECIFIER ** RapidSlat Series 621 Stormtite Doors are designed for exterior and interior openings that require a high-speed, high-cycle door. Available in a maximum height of 20 feet and a maximum width of 20 feet. Standard windload design 20 PSF. Note that windload design does not apply when wear strip guides are used. Windload ratings up to and including Miami-Dade County will be available FBC available Q1 2010. Contact the manufacturer for additional information.
 
          B.RapidSlat Series 621 Stormtite Doors by Overhead Door Corporation.
          1.Curtain: Interlocking roll-formed metal slats as specified with endlocks attached to each end of alternate slats to prevent lateral movement.
          a.Flat Profile type F-265 for doors up to 20 feet wide fabricated of:
          1)22 gauge powder coated steel.
          2)20 gauge powder coated steel.
          3)18 gauge powder coated steel.
          4)22 gauge stainless steel.
          5)20 gauge stainless steel.
          6).050 inch aluminum.
          b.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester.
          b)Tan polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          3)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          4)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          2.Bottom Bar: Two metal angles, minimum thickness 3/16 inch, bolted back to back to reinforce curtain in the guides and incorporating a 2-wire, self-monitoring, fail safe, electric sensing edge with a yellow/black striped vinyl cover. Angles shall be:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the ones not required.
          a.Primed black painted galvanized steel.
          b.Powder coated steel.
          c.Powder coated extruded aluminum.
          d.Stainless steel.
          3.Guides: Three Structural steel angles.
          ** NOTE TO SPECIFIER ** Select one of the following four finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Premium: Weather resistant polyester powder coat.
          c.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          d.Finish: Stainless steel.
          ** NOTE TOSPECIFIER ** Note that motor HP is dependant on the door size(s) required. Contact manufacturer for HP requirements.
          4.Motor: Direct drive, hypoid gear motor/brake assembly sized for openings. Provide with a manual hand crank for operation during power outages. Operator and drive assembly is factory pre-assembled and provided with low voltage factory wiring with quick connect wiring harnesses where applicable.
          a.Opening Speed: 20 inches per second.
          b.Closing Speed: 12 inches per second.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          c.Electrical Characteristics: 208/230V AC, three phase per motor/drive.
          d.Electrical Characteristics: 460V AC, 3 phase per motor/drive.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          e.Left hand mount.
          f.Right hand mount.
          5.Control Panel: Provide electronic Variable Frequency drive controller with microprocessor self-diagnostics. Two line LCD readout indicates door action, alarm conditions, and fault conditions. Time delay self close timer and non-resettable cycle counter is included. Enclosure is NEMA 4X rated.
          6.Door Roll: Directly driven, springless roll shall be steel tube with integral shafts, keyed on the Drive End and supported by self-aligning greaseable sealed bearings. Door shall not require any counterbalance device.
          7.Hood: Protecting drive motor, barrel, chain, stop lock brake and sprocket from dirt and debris and extending between the support brackets. Fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following hood material paragraphs; and delete the ones not required. Standard hood assembly is 24 gauge black painted steel.
          a.24 gauge black painted steel.
          b.24 gauge powder coated steel.
          c.Stainless Steel with brush finish.
          d.Powder coated aluminum.
          ** NOTE TO SPECIFIER ** Select the following paragraph for exterior mounted doors; and delete if not required.
          e.Provide with sloped top for exterior mounting.
          8.Brackets: Provide metal brackets to support motor, curtain, and hood and fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following bracket material paragraphs; and delete the ones not required. Standard is black painted steel.
          a.Black painted steel.
          b.Powder coated aluminum.
          c.Stainless Steel.
          9.Safety Devices: Provide door with following safety devices:
          a.Photoelectric sensors that cast an invisible beam across the door opening and reverses the downward motion of the door when an object enters the path of the beam.
          b.Self-monitoring 2-wire, black/yellow striped electric fail-safe sensing edge reverses downward motion upon impact.
          c.Automatic stop lock brake eliminates uncontrolled curtain travel independent of other safeties.
          10.Actuators:
          a.One Open/Close/Stop push button station incorporated into Control Panel.
          ** NOTE TO SPECIFIER ** Complete the following paragraph for optional equipment as required; and delete if not required. Specify optional push buttons, loop detectors, radio control, motion detectors, or any combination thereof as required. Considerable thought should be given to the choice of actuators based on the type of traffic and traffic flow through the opening. Contact the manufacturer for additional information.
          b.Loop detectors.
          c.Radio control.
          d.Push buttons.
          e.Motion detectors.
          f.Pull cords.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL# ___.
          ** NOTE TO SPECIFIER ** RapidSlat Series 626 Stormtite Insulated Doors are designed for exterior and interior openings that require a high-speed, high-cycle door. Available in a maximum height of 20 feet and a maximum width of 20 feet. Standard windload design 20 PSF. Note that windload design does not apply when wear strip guides are used. Windload ratings up to and including Miami-Dade County will be available FBC available Q1 2010. Contact the manufacturer for additional information.
 
          C.RapidSlat Series 626 Stormtite Insulated Doors by Overhead Door Corporation.
          1.Curtain: Interlocking roll-formed metal slats as specified with endlocks attached to each end of alternate slats to prevent lateral movement.
          a.Flat Profile insulated type F-265i with 24 gauge back covering for doors up to 20 feet wide fabricated of:
          1)22 gauge powder coated steel.
          2)20 gauge powder coated steel.
          3)18 gauge powder coated steel.
          4)22 gauge stainless steel.
          5)20 gauge stainless steel.
          6).050 inch aluminum.
          b.Insulation: Slat cavity shall be filled with CFC-free, foamed-in-place, polyurethane insulation.
          1)R-Value: 7.7, U-Value: 0.13.
          2)Sound Rating: STC-21.
          c.Finish:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs for Polyester top coat or Powder top coat and delete the one not required. Polyester top coat is standard.
          1)Polyester Top Coat.
          a)Gray polyester..
          b)Tan polyester.
          2)Powder coat: PowderGuard.
          ** NOTE TO SPECIFIER ** PowderGuard weather resistant polyester powder coat available in 197 colors; custom color match and EZ Clean treatment options available. See Tiger Drylac RAL Colors* Brochure for color selection. PowderGuard Weathered Finish available in 11 color options, see PowderGuard Finish brochure for color selection.
          3)PowderGuard Premium: Weather resistant polyester powder coat color as selected by the Architect.
          4)PowderGuard Weathered Finish: Industrial textured powder coat provides a thicker, more scratch resistant coat. Applied to entire door system including slats, guides, bottom bar and head plate.
          2.Bottom Bar: Two metal angles, minimum thickness 3/16 inch, bolted back to back to reinforce curtain in the guides and incorporating a 2-wire, self-monitoring, fail safe, electric sensing edge with a yellow/black striped vinyl cover. Angles shall be:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the ones not required.
          a.Primed black painted galvanized steel.
          b.Powder coated steel.
          c.Powder coated extruded aluminum.
          d.Stainless steel.
          3.Guides: Three Structural steel angles.
          ** NOTE TO SPECIFIER ** Select one of the following four finish paragraphs and delete the one not required.
          a.Finish: PowderGuard Weathered finish with iron/black powder.
          b.Finish: PowderGuard Premium: Weather resistant polyester powder coat.
          c.Finish: PowderGuard Zinc Finish for guides, bottom bar and head plate.
          d.Finish: Stainless steel.
          ** NOTE TOSPECIFIER ** Note that motor HP is dependant on the door size(s) required. Contact manufacturer for HP requirements.
          4.Motor: Direct drive, hypoid gear motor/brake assembly sized for openings. Provide with a manual hand crank for operation during power outages. Operator and drive assembly is factory pre-assembled and provided with low voltage factory wiring with quick connect wiring harnesses where applicable.
          a.Opening Speed: 20 inches per second.
          b.Closing Speed: 12 inches per second.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          c.Electrical Characteristics: 208/230V AC, three phase per motor/drive.
          d.Electrical Characteristics: 460V AC, 3 phase per motor/drive.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs; and delete the one not required.
          e.Left hand mount.
          f.Right hand mount.
          5.Control Panel: Provide electronic Variable Frequency drive controller with microprocessor self-diagnostics. Two line LCD readout indicates door action, alarm conditions, and fault conditions. Time delay self close timer and non-resettable cycle counter is included. Enclosure is NEMA 4X rated.
          6.Door Roll: Directly driven, springless roll shall be steel tube with integral shafts, keyed on the Drive End and supported by self-aligning greaseable sealed bearings. Door shall not require any counterbalance device.
          7.Hood: Protecting drive motor, barrel, chain, stop lock brake and sprocket from dirt and debris and extending between the support brackets. Fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following hood material paragraphs; and delete the ones not required. Standard hood assembly is 24 gauge black painted steel.
          a.24 gauge black painted steel.
          b.24 gauge powder coated steel.
          c.Stainless Steel with brush finish.
          d.Powder coated aluminum.
          ** NOTE TO SPECIFIER ** Select the following paragraph for exterior mounted doors; and delete if not required.
          e.Provide with sloped top for exterior mounting.
          8.Brackets: Provide metal brackets to support motor, curtain, and hood and fabricated of:
          ** NOTE TO SPECIFIER ** Select one of the following bracket material paragraphs; and delete the ones not required. Standard is black painted steel.
          a.Black painted steel.
          b.Powder coated aluminum.
          c.Stainless Steel.
          9.Safety Devices: Provide door with following safety devices:
          a.Photoelectric sensors that cast an invisible beam across the door opening and reverses the downward motion of the door when an object enters the path of the beam.
          b.Self-monitoring 2-wire, black/yellow striped electric fail-safe sensing edge reverses downward motion upon impact.
          c.Automatic stop lock brake eliminates uncontrolled curtain travel independent of other safeties.
          10.Actuators:
          a.One Open/Close/Stop push button station incorporated into Control Panel.
          ** NOTE TO SPECIFIER ** Complete the following paragraph for optional equipment as required; and delete if not required. Specify optional push buttons, loop detectors, radio control, motion detectors, or any combination thereof as required. Considerable thought should be given to the choice of actuators based on the type of traffic and traffic flow through the opening. Contact the manufacturer for additional information.
          b.Loop detectors.
          c.Radio control.
          d.Push buttons.
          e.Motion detectors.
          f.Pull cords.
          11.Windload Design:
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the one not required. Standard windload is 20 PSF. Note that if wear strip guides are used the windload warranty does not apply. Contact the manufacturer for current data on Miami-Dade County and/or FBC Certification.
          a.Standard windload shall be 20 PSF.
          b.Miami-Dade County NOA ___.
          c.FBC certification FL# ___.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Verify opening sizes, tolerances and conditions are acceptable.
 
          B.Examine conditions of substrates, supports, and other conditions under which this work is to be performed.
 
          C.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
 
          B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
 
          B.Use anchorage devices to securely fasten assembly to wall construction and building framing without distortion or stress.
 
          C.Securely and rigidly brace components suspended from structure. Secure guides to structural members only.
 
          D.Fit and align assembly including hardware; level and plumb, to provide smooth operation.
          ** NOTE TO SPECIFIER ** Select the following paragraph for electric operation of coiling doors and delete if not required.
 
          E.Coordinate installation of electrical service with Section 16150. Complete wiring from disconnect to unit components.
 
          F.Coordinate installation of sealants and backing materials at frame perimeter as specified in Section 07900.
 
          G.Install perimeter trim and closures.
 
          H.Instruct Owner’s personnel in proper operating procedures and maintenance schedule.
 
          3.4ADJUSTING
 
          A.Test for proper operation and adjust as necessary to provide proper operation without binding or distortion.
 
          B.Adjust hardware and operating assemblies for smooth and noiseless operation.
 
          3.5CLEANING
 
          A.Clean curtain and components using non-abrasive materials and methods recommended by manufacturer.
 
          B.Remove labels and visible markings.
 
          C.Touch-up, repair or replace damaged products before Substantial Completion.
 
          3.6PROTECTION
 
          A.Protect installed products until completion of project.
 
         
END OF SECTION