. This section is based on the products of Overhead Door Corp., which is located at: 2501 S. State Hwy. 121 Suite 200 Lewisville, TX 75067 Toll Free Tel: 800-929-3667 Tel: 469-549-7100 Fax: 972-906-1499 Email: request info Web: www.overheaddoor.com [Click Here ] for additional information. Overhead Door Corporation pioneered the upward-acting door industry, inventing the first upward-acting door in 1921 and the first electric door opener in 1926. Today, we continue to be the industry leader through the strength of our product innovation, superior craftsmanship and outstanding customer support, underscoring a legacy of quality, expertise and integrity. That's why design and construction professionals specify Overhead Door Corporation products more often than any other brand. The section includes Overhead Door Corporation's rolling service door product line ensures that your project specifications will be met with ease and style. Ideal for situations where sideroom and headroom are at a premium, our upward-coiling service doors fit openings up to 1500 SF and are available with the industry's widest array of slat profiles, curtain materials and colors, offering a virtually endless array of options to satisfy both aesthetic considerations and working requirements. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| PART 1 | GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | SECTION INCLUDES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Overhead coiling service doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Overhead coiling ventilated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Overhead coiling insulated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Overhead coiling sheet doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | RELATED SECTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Section 05500 - Metal Fabrications: Support framing and framed opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Section 06200 - Finish Carpentry: Wood jamb and head trim. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Section 08710 - Door Hardware: Product Requirements for cylinder core and keys. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Section 09900 - Painting: Field applied finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Section 16130 - Raceway and Boxes: Conduit from electric circuit to door operator and from door operator to control station. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Section 16150 - Wiring Connections: Power to disconnect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | REFERENCES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | ASTM A 653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | ASTM A 666 - Standard Specification for Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | ASTM A 924 - Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric). | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | NEMA 250 - Enclosures for Electrical Equipment (1000 Volts Maximum). | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | NEMA MG 1 - Motors and Generators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | DESIGN / PERFORMANCE REQUIREMENTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Wind Loads: Design door assembly to withstand wind/suction load of 20 psf (958 Pa) without damage to door or assembly components. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Operation: Design door assembly, including operator, to operate for not less than 20,000 cycles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | SUBMITTALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Submit under provisions of Section 01300. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Product Data: Manufacturer's data sheets on each product to be used, including: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Preparation instructions and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Storage and handling requirements and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Details of construction and fabrication. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Installation instructions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Shop Drawings: Include detailed plans, elevations, details of framing members, anchoring methods, required clearances, hardware, and accessories. Include relationship with adjacent construction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Manufacturer's Certificates: Certify products meet or exceed specified requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Operation and Maintenance Data: Submit lubrication requirements and frequency, and periodic adjustments required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | QUALITY ASSURANCE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Manufacturer Qualifications: Company specializing in performing Work of this section with a minimum of five years experience in the fabrication and installation of security closures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Installer Qualifications: Installer Qualifications: Company specializing in performing Work of this section with minimum three years and approved by manufacturer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Finish areas designated by Architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Refinish mock-up area as required to produce acceptable work. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.7 | DELIVERY, STORAGE, AND HANDLING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Store products in manufacturer's unopened packaging until ready for installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Protect materials from exposure to moisture. Do not deliver until after wet work is complete and dry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Store materials in a dry, warm, ventilated weathertight location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.8 | PROJECT CONDITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.9 | COORDINATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Coordinate Work with other operations and installation of adjacent materials to avoid damage to installed materials. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 2 | PRODUCTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | MANUFACTURERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer: Overhead Door Corp., which is located at: 2501 S. State Hwy. 121 Suite 200 ; Lewisville, TX 75067; Toll Free Tel: 800-929-3667; Tel: 469-549-7100; Fax: 972-906-1499; Email: request info; Web: www.overheaddoor.com | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Substitutions: Not permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Requests for substitutions will be considered in accordance with provisions of Section 01600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | OVERHEAD COILING SERVICE DOORS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Light Commercial Doors: Overhead Door Corporation, 600 Series Coil-Away Service Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed galvanized steel slats, flat crown profile type CAW, 26 gauge for widths up to 12 feet 4 inches (3.75 m), 24 gauge for widths up to 16 feet (4.88 m). End of each slat shall be locked from lateral movement by a staking lock system. (Galvanized alternate malleable end locks.) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Curtain slats and hood shall be galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | White polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Brown polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: Vinyl bottom seal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: Extruded aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: Roll-formed galvanized steel shapes attached to continuous galvanized steel wall angle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: Galvanized steel to support counterbalance and curtain. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel and supporting the curtain with deflection limited to 0.03 inch per foot of span. Spring tension shall be adjustable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Hood: Not Required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Hood: 24 gauge galvanized steel with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Manual push up for doors up to 100 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain hoist for doors over 100 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | N/A. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Key operation with open, close, and stop controls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Push-button and key operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Controls for interior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Controls for exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Controls for both interior and exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Controls surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8) | Controls flush mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Special Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Vehicle detector operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Radio control operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Card reader control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Photocell operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Door timer operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Commercial light package. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Explosion and dust ignition proof control wiring. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Locking: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Interior bottom bar slide bolt for manually operated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Exterior slide lock for manually operated mini-warehouse doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Chain keeper locks for chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Interior slide bolt lock for electric operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Cylinder lock for electric operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Wall Mounting Condition: Face-of-wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Commercial Doors: Overhead Door Corporation, 615 Series Service Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement. Curved profile type C-187 for doors up to 16 feet 4 inches (4.98 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Fabricated of 24 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Fabricated of 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Curtain slats and hood shall be galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Gray polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Tan polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Powder coating finish in color as selected by Architect from manufacturer's standard colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: Vinyl bottom seal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Extruded aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Two galvanized steel angles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: Roll-formed galvanized steel shapes attached to continuous galvanized steel wall angle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: Galvanized steel to support counterbalance and curtain. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Hood: 24 gauge galvanized steel with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Manual push up for doors up to 108 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain hoist for doors over 108 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Pneumatic sensing edge, with DABB only. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge, with DABB only. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Key operation with open, close, and stop controls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Push-button and key operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Controls for interior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Controls for exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Controls for both interior and exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Controls surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8) | Controls flush mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Special Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Vehicle detector operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Radio control operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Card reader control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Photocell operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Door timer operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Commercial light package. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Explosion and dust ignition proof control wiring. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Locking: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Interior bottom bar slide bolt for manually operated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain keeper locks for chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Interior slide bolt lock for electric operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Cylinder lock for electric operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Wall Mounting Condition: Face-of-wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Commercial Doors with Weatherstripping: Overhead Door Corporation, 616 Series Service Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement. Flat profile type F-265 for doors up to 16 feet 4 inches (4.98 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Fabricated of 24 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Fabricated of 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Curtain slats and hood shall be galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Gray polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Tan polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Powder coating finish in color as selected by Architect from manufacturer's standard colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Vinyl bottom seal, exterior guide, and internal hood seals. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Lintel seals. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Extruded aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Two galvanized steel angles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: Three galvanized steel angles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: Cold rolled galvanized steel to support counterbalance, curtain and hood for doors up to 12 feet (3.66 m) high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Brackets: Painted galvanized hot rolled steel plate for doors over 12 feet (3.66 m) high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Hood: 24 gauge galvanized steel with intermediate supports as required. Provide with internal hood baffle weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Manual push up for doors up to 108 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain hoist for doors over 108 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Pneumatic sensing edge, with DABB only. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge, with DABB only. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Key operation with open, close, and stop controls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Push-button and key operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Controls for interior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Controls for exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Controls for both interior and exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Controls surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8) | Controls flush mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Special Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Vehicle detector operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Radio control operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Card reader control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Photocell operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Door timer operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Commercial light package. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Explosion and dust ignition proof control wiring. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Locking: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Interior bottom bar slide bolt for manually operated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain keeper locks for chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Interior slide bolt lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Cylinder lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Wall Mounting Condition: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Face-of-wall mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Between jambs mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Provide open with no cover. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Provide with Plexiglas covers over openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Industrial Doors: Overhead Door Corporation, 610 Series Service Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Curved profile type C-187 for doors up to 15 feet 4 inches (4.67 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 22 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | 20 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Curved profile type C-275 for doors up to and between 15 feet 4 inches (4.67 m) and 18 feet 4 inches (5.59 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 22 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 16 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Curved profile type C-275 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 20 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 16 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Curved profile type C-275 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 16 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 16 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Flat profile type F-265 for doors up to 18 feet 4 inches (5.59 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 22 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Flat profile type F-265 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 20 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Flat profile type F-265 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 16 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| h. | For fenestrated service doors, provide slats with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| i. | For ventilated service doors, provide slats with 1/16 inch (16 mm) diameter perforations 3/32 inch (2.4 mm) on center staggered rows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a) | Gray polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b) | Tan polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c) | Powder coating finish in color as selected by Architect from manufacturer's standard colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless Steel: Slats and hood shall be stainless steel finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: 2B mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: No. 4 satin finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum: Slats and hood shall be aluminum finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: Clear anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Finish: Bronze anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Vinyl bottom seal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Guide weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Extruded aluminum for doors up to 15 feet 4 inches (4.67 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Two primed steel angles for doors over 15 feet 4 inches (4.67 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Two galvanized steel angles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Roll-formed primed steel shapes attached to continuous primed steel wall angle up to 15 feet 4 inches (4.67 m) wide or high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Three structural steel angles with minimum thickness of 3/16 inch (5 mm) for doors over 15 feet 4 inches (4.67 m) wide or high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Hot rolled steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Galvanized steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Hood: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 24 gauge galvanized steel with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless steel, 24 gauge hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Manual push up for doors up to 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain hoist for doors up to 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Chain hoist for doors over 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Crank operation for doors over 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Pneumatic sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Key operation with open, close, and stop controls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Push-button and key operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Controls for interior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Controls for exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Controls for both interior and exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Controls surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8) | Controls flush mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Special Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Vehicle detector operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Radio control operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Card reader control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Photocell operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Door timer operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Commercial light package. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Explosion and dust ignition proof control wiring. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Locking: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Interior bottom bar slide bolt for manually operated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain keeper locks for chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Interior slide bolt lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Cylinder lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Wall Mounting Condition: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Face-of-wall mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Between jambs mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Provide open with no cover. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Provide with Plexiglas covers over openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Heavy Duty Industrial Doors: Overhead Door Corporation, 620 Series Stormtite Service Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Flat profile type F-265 for doors up to 18 feet 4 inches (5.59 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 22 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Flat profile type F-265 for doors between 18 feet 4 inches (5.59 m) and 25 feet 4 inches (7.72 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 20 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 18 gauge aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Flat profile type F-265 for doors between 25 feet 4 inches (7.72 m) and 40 feet (12.19 m) wide, fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 16 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 18 gauge aluminum. (Maximum width of 27 feet (8.23 m).) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a) | Gray polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b) | Tan polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c) | Powder coating finish in color as selected by Architect from manufacturer's standard colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless Steel: Slats and hood shall be stainless steel finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: 2B mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: No. 4 satin finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum: Slats and hood shall be aluminum finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: Clear anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Finish: Bronze anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Vinyl bottom seal, exterior guide and internal hood seals. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Interior guide weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Lintel weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Extruded aluminum for doors up to 15 feet 4 inches (4.67 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Two primed steel angles for doors over 15 feet 4 inches (4.67 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Two galvanized steel angles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: Guides weatherstripped with a vinyl weather seal at each jamb on the exterior curtain side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Roll-formed primed steel shapes attached to continuous primed steel wall angle up to 15 feet 4 inches (4.67 m) wide or high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Three structural steel angles with minimum thickness of 3/16 inch (5 mm) for doors over 15 feet 4 inches (4.67 m) wide or high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Hot rolled prime painted steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Galvanized steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Hood: Provide with internal hood baffle weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 24 gauge galvanized steel with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless steel, 24 gauge hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Manual push up for doors up to 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Chain hoist for doors up to 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Chain hoist for doors over 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Crank operation for doors over 96 SF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Pneumatic sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Key operation with open, close, and stop controls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Push-button and key operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Controls for interior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Controls for exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Controls for both interior and exterior location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Controls surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8) | Controls flush mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Special Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Vehicle detector operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Radio control operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Card reader control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | Photocell operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | Door timer operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | Commercial light package. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Explosion and dust ignition proof control wiring. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Locking: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Interior bottom bar slide bolt for manually operated doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Interior bottom bar slide bolt with chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Chain keeper locks for chain hoist operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Interior slide bolt lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Cylinder lock for electric operation with interlock switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Wall Mounting Condition: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Face-of-wall mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Between jambs mounting. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Vision Lites: Provide with 3 inch by 5/8 inch (76 mm by 16 mm) uniformly spaced openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Provide open with no cover. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Provide with Plexiglas covers over openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | INSULATED OVERHEAD COILING SERVICE DOORS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Overhead Coiling Stormtite Insulated Service Doors: Overhead Door Corporation 625 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Curtain: Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Flat profile type F-265I for doors up to 40 feet (12.19 m) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Front slat fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 24 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 22 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | 20 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4) | 18 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5) | 22 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6) | 20 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7) | Aluminum .040 inch (1 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Back slat fabricated of: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 24 gauge galvanized steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | 24 gauge stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Aluminum .024 inch (.06 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Slat cavity filled with CFC-free foamed-in-place, polyurethane insulation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Finish: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Galvanized Steel: Slats and hood galvanized in accordance with ASTM A 653 and receive rust-inhibitive, roll coating process, including 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Top Coat Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a) | Gray polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b) | Tan polyester top coat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c) | Powder coating finish in color as selected by Architect from manufacturer's standard colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless Steel: Slats and hood shall be stainless steel finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: 2B mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: No. 4 satin finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum: Slats and hood shall be aluminum finished as follows. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Finish: Clear anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3) | Finish: Bronze anodized finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherseals: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Vinyl bottom seal, exterior guide and internal hood seals. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Interior guide weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Lintel weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Bottom Bar: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Two prime painted steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Two galvanized steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Two stainless steel angles minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides.. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Extruded aluminum angle minimum thickness 1/8 inch (3 mm) bolted back to back to reinforce curtain in the guides. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guides: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Three prime painted structural steel angles with minimum thickness of 3/16 inch (4.76 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Three galvanized structural steel angles with minimum thickness of 3/16 inch (4.76 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Guides weatherstripped with a vinyl weather seal at each jamb, on the exterior curtain side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Guides weatherstripped with a vinyl weather seal at each jamb, on the exterior curtain side and interior curtain side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Brackets: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Hot rolled prime painted steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Galvanized steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Stainless steel to support counterbalance, curtain and hood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Counterbalance: Helical torsion spring type housed in a steel tube or pipe barrel, supporting the curtain with deflection limited to 0.03 inch per foot of span. Counterbalance is adjustable by means of an adjusting tension wheel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Hood: Provide with internal hood baffle weatherseal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 24 gauge galvanized steel with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Stainless steel, 24 gauge hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Aluminum hood with intermediate supports as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Manual Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain hoist. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Crank operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sensing Edge Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Pneumatic sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Electric sensing edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Operator Controls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Push-button operated control stations with open, close, and stop buttons. | |||||||||||||||||||||||||||||||||||||||||||||||||