MasterFormat: 95
Download this Coiling and Rolling Doors Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Raynor Coiling and Rolling Doors
 
         
SECTION 08330
 
         
COILING AND ROLLING DOORS
 
         
 
         
 
         
Copyright 2007 - 2011 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Raynor; commercial coiling and rolling doors.

This section is based on the products of Raynor, which is located at:
1101 East River Rd. P. O. Box 448
Dixon, IL 61021-0448
Toll Free Tel: 800-4-RAYNOR
Tel: 815-288-1431
Email: request info
Web: www.raynor.com
[ Click Here ] for additional information.
          For more than 60 years, architects and construction specifiers have counted on Raynor for doors and electric operators that meet the harshest environment and application demands. For your convenience, additional Raynor commercial specifications and drawings can be downloaded from www.raynor.com and are available on CD-ROM.

Raynor has more than 600 professional installing distributors in the United States and throughout 54 nations around the world. They pride themselves in excellent product knowledge, installation and service after the sale. Earn CE units and receive valuable knowledge about commercial doors by participating in an AIA/CES course. If you would like a Raynor Representative to contact you about presenting an AIA/CES course to your company, fill out an online form at www.raynor.com, or contact us at 1-800-4-RAYNOR.

Refer to specifications in this section for the following types of Raynor Overhead Doors: Coiling and rolling doors including DuraCoil, DuraShutter, DuraGrille, FireCoil, FireShutter, and Fabricoil. ArmorBriteTM is a trademark of Tiger DrylacŪ.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete types below not applicable to this project.
 
          A.Coiling doors.
 
          B.Coiling counter shutters.
 
          C.Coiling grilles.
 
          D.Coiling fire doors.
 
          E.Fire curtains.
 
          F.Traffic doors.
 
          G.Electric operators.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 05500 - Metal Fabrications: Miscellaneous for steel supports.
 
          B.Section 08710 - Door Hardware: Hardware, locks, access panels.
 
          C.Section 09900 - Painting: Field painting.
 
          D.Section 11150 - Parking Control Equipment: Parking control equipment for remote door controls.
 
          E.Section 16050 - Basic Electrical Materials and Methods: Electrical connections and service for powered door operators.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.American Society for Testing and Materials (ASTM) A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
 
          1.4SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Installation methods.
 
          C.Shop Drawings:
          1.Provide drawings indicating track details, head and jamb conditions, spring shafts, anchorage, accessories, finish colors, patterns and textures, operator mounts and other related information.
          2.Regulatory Requirements and Approvals: Provide shop drawings in compliance with local Authority Having Jurisdiction (AHJ).
 
          D.Certifications:
          1.Submit manufacturer's certificate that products meet or exceed specified requirements.
          2.Submit installer qualifications.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          E.Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
 
          F.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
 
          1.5QUALITY ASSURANCE
 
          A.Installer Qualifications: Utilize an installer having demonstrated experience on projects of similar size and complexity, and trained and authorized by the door manufacturer to perform the work of this section.
 
          1.6DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging until ready for installation.
 
          B.Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
 
          1.7PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Raynor, which is located at: 1101 East River Rd. P. O. Box 448 ; Dixon, IL 61021-0448; Toll Free Tel: 800-4-RAYNOR; Tel: 815-288-1431; Email: request info; Web: www.raynor.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
          2.2COILING AND ROLLING DOORS
          ** NOTE TO SPECIFIER ** Delete DuraCoil Optima if not required. DuraCoil Optima is for interior or exterior applications up to 40 ft in height with slat restrictions.
 
          A.DuraCoil Optima as manufactured by Raynor Garage Doors:
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand crank operation.
          3)Provide doors designed for hand chain operation.
          4)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Structural Performance Requirements:
          ** NOTE TO SPECIFIER ** Insert required wind load. p.s.f.
          a.Wind Loads: Uniform pressure of: ________ psf.
          3.Curtain Material: Interlocking steel slats, 18 gauge (0.047 inch minimum steel thickness), roll-formed from commercial quality hot-dipped galvanized (G-90) steel in compliance with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete slat types not required.
          a.Slat Type: Flat slat.
          b.Slat Type: Large curved slat.
          c.Slat Type: Insulated flat slat with back cover.
          1)Insulation: Polyisocyanurate with R-value 6.24 and U-value 0.160.
          ** NOTE TO SPECIFIER ** Delete back cover types not required.
          2)Back Covers: Galvanized steel, 24 gauge (0.023 inch minimum steel thickness) steel.
          3)Back Covers: Galvanized steel, 22 gauge (0.030 inch minimum steel thickness) steel.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of door opening.
          5.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Tan finish is available in flat slats and insulated flat slats only.
          7.Color and Finish: One finish coat of tan polyester paint applied over one coat of white epoxy primer.
          8.Color and Finish: ArmorBrite Powdercoat.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          9.Color and Finish: Galvanized.
          10.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          11.Bottom Bar and Seal: Two roll-formed galvanized steel angles, minimum 1-1/2 inches by 1-1/2 inches by 1/8 inch (38.1 mm x 38.1 mm x 3.2 mm) with single-contact type bottom astragal. Structural angle bottom bar to receive one coat of rust-inhibitive primer.
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels or retain only vision panel types required for the project. Number and locations of vision panels to comply with door elevation drawings.
          12.Vision Panels: 4 inches by 1 inch (101.6 mm by 25.4 mm) plexiglass, thickness as follows:
          a.1/8 inch (3.2 mm) thick for flat and curved slats.
          b.5/8 inch (15.9 mm) thick for insulated slats.
          ** NOTE TO SPECIFIER ** Delete curtain wear strips if not required.
          13.Curtain Wear Strips: Polyethylene tape (UHMW).
          14.Guide Assemblies: Three structural steel angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) and fitted with removable curtain stops. Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          15.Jamb Construction: Steel jambs with self-tapping fasteners.
          16.Jamb Construction: Wood jambs with lag bolt fasteners.
          17.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          18.Counterbalance System:
          a.Headplates: 3/16 inch (4.8 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion spring or weight counterbalance in following two paragraphs.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          ** NOTE TO SPECIFIER ** Weight Counterbalance is not available on insulated flat slats.
          2)FeatherLite weight counterbalance.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          19.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Square Hood: 24 gauge steel, finish-painted to match curtain.
          c.Weight Counterbalance Cover: 24 gauge steel, finish-painted to match curtain (for FeatherLite).
          d.Hood Baffle: Provide hood baffle with EPDM rubber seal to inhibit air infiltration through hood cavity.
          e.Headplate Cover: 24 gauge steel, finish-painted to match curtain.
          ** NOTE TO SPECIFIER ** Delete weather seals not required.
          20.Weather Seal: Guide brush seal.
          21.Weather Seal: Snap-on vinyl seal.
          ** NOTE TO SPECIFIER ** Retain or delete paragraphs below to suit project requirements.
          22.Locks: Furnish door system with the following:
          a.Locking Bar: To receive padlock provided by Owner; for doors operated with hand chain or hand crank.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: To receive padlock provided by Owner; for doors operated with hand chain.
          d.Cylinder Lock: For use with hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete DuraCoil Standard if not required. Interior and exterior applications in widths to 30 feet and heights to 30 feet.
 
          B.DuraCoil Standard as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand crank operation.
          3)Provide doors designed for hand chain operation.
          4)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Structural Performance Requirements
          ** NOTE TO SPECIFIER ** Insert required wind load. p.s.f.
          a.Wind Loads: Uniform pressure of: ________ psf.
          3.Curtain Material: Interlocking steel slats, roll-formed from commercial quality hot-dipped galvanized (G-90) steel in compliance with ASTM A-653, thickness as follows:
          ** NOTE TO SPECIFIER ** Delete gauge not required.
          a.Thickness: 22 gauge (0.030 inch minimum steel thickness) steel.
          b.Thickness: 20 gauge (0.036 inch minimum steel thickness) steel.
          ** NOTE TO SPECIFIER ** Delete slat types not required.
          c.Slat Type: Flat slat.
          d.Slat Type: Small curved slat.
          e.Slat Type: Large curved slat.
          f.Slat Type: Perforated flat slat, punched with 1/16 inch (1.6 mm) diameter holes across entire length and providing 31 percent open area per square foot of door.
          g.Slat Type: Insulated flat slat with back cover.
          1)Insulation: Polyisocyanurate with R-value 6.24 and U-value 0.160.
          ** NOTE TO SPECIFIER ** Delete back cover types not required.
          2)Back Covers: Galvanized steel, 24 gauge (0.023 inch minimum steel thickness) steel.
          3)Back Covers: Galvanized steel, 22 gauge (0.030 inch minimum steel thickness) steel.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of door opening.
          5.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** White finish is available in 22 gauge flat slats and insulated flat slats only.
          7.Color and Finish: One finish coat of white polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Tan finish is available in flat slats and insulated flat slats only.
          8.Color and Finish: One finish coat of tan polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Galvanized finish is available in 22 gauge flat slats and insulated flat slats only.
          9.Color and Finish: Galvanized.
          10.Color and Finish: ArmorBrite Powdercoat applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          11.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          12.Bottom Bar and Seal: Two roll-formed galvanized steel angles, minimum 1-1/2 inches by 1-1/2 inches by 1/8 inch (38.1 mm x 38.1 mm x 3.2 mm) with single-contact type bottom astragal. Structural angle bottom bar to receive one coat of rust-inhibitive primer.
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels or retain only vision panel types required for the project. Number and locations of vision panels to comply with door elevation drawings.
          13.Vision Panels: 4 inches by 1 inch (101.6 mm by 25.4 mm) plexiglass, thickness as follows:
          a.1/8 inch (3 mm) thick for flat and curved slats.
          b.5/8 inch (16 mm) thick for insulated slats.
          ** NOTE TO SPECIFIER ** Delete curtain wear strips if not required.
          14.Curtain Wear Strips: Polyethylene tape (UHMW).
          15.Guide Assemblies: Three structural steel angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 51 mm by 4.8 mm) and fitted with removable curtain stops. Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          16.Jamb Construction: Steel jambs with self-tapping fasteners.
          17.Jamb Construction: Wood jambs with lag bolt fasteners.
          18.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          19.Counterbalance System:
          a.Headplates: 3/16 inch (4.8 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion spring or weight counterbalance in following two paragraphs.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          ** NOTE TO SPECIFIER ** Weight Counterbalance is not available on insulated flat slats.
          2)FeatherLite weight counterbalance.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          20.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Square Hood: 24 gauge steel, finish-painted to match curtain.
          c.Weight Counterbalance Cover: 24 gauge steel, finish-painted to match curtain (for FeatherLite.
          d.Hood Baffle: Provide EPDM rubber seal to inhibit air infiltration through hood cavity.
          e.Headplate Cover: 24 gauge steel, finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete weather seals not required.
          21.Weather Seal: Guide brush seal.
          22.Weather Seal: Snap-on vinyl seal.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          23.Locks: Furnish door system with the following:
          a.Locking Bar: For manual doors and doors operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For doors operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete DuraCoil Basic if not required. Interior or exterior applications, 14 feet by 14 feet, maximum size.
 
          C.DuraCoil Basic as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand crank operation.
          3)Provide doors designed for hand chain operation.
          4)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Structural Performance Requirements:
          ** NOTE TO SPECIFIER ** Insert required wind load. p.s.f.
          a.Wind Loads: Uniform pressure of: ________ psf.
          3.Curtain Material: Flat interlocking steel slats, 24 gauge (0.023 inch minimum steel thickness), roll-formed from commercial quality hot-dipped galvanized (G-60) steel in compliance with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of door opening.
          5.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          7.Color and Finish: One finish coat of tan polyester paint applied over one coat of white epoxy primer.
          8.Endlocks: Zinc-plated stamped steel fastened with two zinc-plate steel rivets.
          9.Bottom Bar and Seal: Two roll-formed galvanized steel angles, minimum 1-1/2 inches by 1-1/2 inches by 1/8 inch (38.1 mm x 38.1 mm x 3.2 mm) with single-contact type bottom astragal.
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels. Number and locations of vision panels to comply with door elevation drawings.
          10.Vision Panels: 4 inches by 1 inch by 1/8 inch thick (101.6 mm by 25.4 mm by 3.2 mm) plexiglass.
          ** NOTE TO SPECIFIER ** Delete curtain wear strips if not required.
          11.Curtain Wear Strips: Polyethylene tape (UHMW).
          12.Guide Assemblies: Minimum 14 gauge roll-formed galvanized steel fastened to 11 gauge galvanized steel wall angle and fitted with removable curtain stops.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          13.Jamb Construction: Steel jambs with self-tapping fasteners.
          14.Jamb Construction: Wood jambs with lag bolt fasteners.
          15.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          16.Counterbalance System:
          a.Headplates: 10 gauge galvanized steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          1)Standard.
          2)High cycle.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          17.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Square Hood: 24 gauge steel, finish-painted to match curtain.
          c.Weight Counterbalance Cover: 24 gauge steel, finish-painted to match curtain.
          d.Hood Baffle: Provide EPDM rubber seal to inhibit air infiltration through hood cavity.
          e.Headplate Cover: 24 gauge steel, finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete weather seals not required.
          18.Weather Seal: Guide brush seal.
          19.Weather Seal: Snap-on vinyl seal.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          20.Locks: Furnish door system with the following:
          a.Locking Bar: For manual doors and doors operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For doors operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete DuraCoil Select if not required. Interior and exterior applications of 26 feet wide with slat restrictions.
 
          D.DuraCoil Select as manufactured by Raynor Garage Doors:
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand crank operation.
          3)Provide doors designed for hand chain operation.
          4)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Structural Performance Requirements:
          ** NOTE TO SPECIFIER ** Insert required wind load. p.s.f.
          a.Wind Loads: Uniform pressure of: ________ psf.
          3.Curtain Material: Interlocking slats, roll formed from the following:
          ** NOTE TO SPECIFIER ** Delete materials not required.
          a.Aluminum, 0.04 inch (1.02 mm) thick.
          b.Aluminum, 0.05 inch (1.3 mm) thick.
          c.Stainless steel, type 304, 22 gauge (0.027 inch) thick.
          d.Stainless steel, type 304, 20 gauge (0.033 inch) thick.
          ** NOTE TO SPECIFIER ** Delete slat types not required.
          e.Slat Type: Flat slat.
          ** NOTE TO SPECIFIER ** Perforated slats not available in stainless steel.
          f.Slat Type: Perforated aluminum flat slat, punched with 1/16 inch (1.6 mm) diameter holes across entire length and providing 31percent open area per square foot of door.
          g.Slat Type: Insulated flat slat with back cover.
          1)Insulation: Polyisocyanurate with R-value 6.24 and U-value 0.160.
          2)Back Covers: Aluminum, 0.04 inch (1.02 mm) minimum aluminum thickness.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of door opening.
          5.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: Clear anodized aluminum.
          7.Color and Finish: Stainless steel #4.
          8.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          9.Bottom Bar and Seal: Two metal angles, minimum 1-1/2 inches by 1-1/2 inches by 1/8 inch (38.1 mm x 38.1 mm x 3.2 mm) with single-contact type vinyl seal. Metal shall be as follows:
          ** NOTE TO SPECIFIER ** Delete materials not required.
          a.Aluminum angles with clear anodized finish.
          b.Stainless steel angles with #4 finish.
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels or retain only vision panel types required for the project. Number and locations of vision panels to comply with door elevation drawings.
          10.Vision Panels: 4 inches by 1 inch (101.6 mm by 25.4 mm) plexiglass, thickness as follows:
          a.1/8 inch (3 mm) thick for flat and curved slats.
          b.5/8 inch (16 mm) thick for insulated slats.
          11.Curtain Wear Strips: Polyethylene tape (UHMW).
          12.Guide Assemblies: Provide guide assemblies as follows:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs describing guide assemblies.
          a.Steel: Consisting of three structural steel angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) fitted with removable curtain stops and finished as follows:
          ** NOTE TO SPECIFIER ** Delete finish not required.
          1)One coat of rust-inhibitive primer.
          2)Galvanized finish.
          b.Stainless Steel: Consisting of three structural stainless steel angles, #4 finish, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) fitted with removable curtain stops.
          c.Aluminum: Consisting of aluminum extrusions, clear anodized, minimum 3 inches by 3 inches by 3/16 inch (76 mm by 76 mm by 4.8 mm) and fitted with removable curtain stops, and finished as follows:
          ** NOTE TO SPECIFIER ** Delete finish not required.
          1)Mill finish.
          2)Clear anodized finish.
          ** NOTE TO SPECIFIER ** Insert color in space provided.
          3)ArmorBrite Powdercoat finish. Color _________.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          13.Jamb Construction: Steel jambs with self-tapping fasteners.
          14.Jamb Construction: Wood jambs with lag bolt fasteners.
          15.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          16.Counterbalance System:
          a.Headplates: 3/16 inch (4.8 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion spring or weight counterbalance in following two paragraphs.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          ** NOTE TO SPECIFIER ** Weight Counterbalance is not available on insulated flat slats.
          2)FeatherLite weight counterbalance.
          ** NOTE TO SPECIFIER ** Delete weather seals not required.
          17.Weather Seal: Guide brush seal.
          18.Weather Seal: Snap-on vinyl seal.
          ** NOTE TO SPECIFIER ** Edit or delete paragraphs below to suit project requirements.
          19.Enclosures:
          a.Round Hood: 24 gauge galvanized steel, painted gray.
          b.Round Hood: 0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          c.Round Hood: 24 gauge stainless steel, #4 finish.
          d.Square Hood: 24 gauge galvanized steel, painted gray.
          e.Square Hood: 0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          f.Square Hood: 24 gauge stainless steel, #4 finish.
          g.Hood Baffle: Provide hood baffle EPDM rubber seal to inhibit air infiltration through hood cavity.
          h.Weight Counterbalance Cover: 24 gauge steel, finish-painted to match curtain.
          i.Headplate Cover: 24 gauge steel, finish painted to match curtain
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          20.Locks: Furnish door system with the following:
          a.Locking Bar: For manual doors and doors operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For doors operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete coiling counter shutters if not required.
 
          2.3COILING COUNTER SHUTTERS
          ** NOTE TO SPECIFIER ** Delete DuraShutter Standard if not required. DuraShutter Standard doors are for interior use only, up to 20 feet wide and 8 feet in height.
 
          A.DuraShutter Standard as manufactured by Raynor Garage Door.
          1.Shutters:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete shutter operation not required.
          1)Provide shutters designed for manual operation.
          2)Provide shutters designed for hand crank operation.
          3)Provide shutters designed for tube motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the shutter that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Curtain Material: Interlocking flat slats, roll formed 22 gauge (0.030 inch minimum steel thickness) commercial quality hot-dipped galvanized (G-90) steel complying with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          3.Mounting: To face of wall on each side of shutter opening.
          4.Mounting: Between jambs of wall opening.
          5.Mounting: Integral frame as follows:
          ** NOTE TO SPECIFIER ** Delete frame type not required.
          a.Painted Slip-in Frame: For use with a pre-existing finished opening.
          b.Painted Build-in Frame: For use with masonry wall construction.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          7.Color and Finish: ArmorBrite Powdercoat.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          8.Endlocks: Lateral movement of the slats to be contained by means of zinc-plated stamped steel endlocks fastened to slat.
          9.Bottom Bar and Seal: Roll-formed painted tubular steel type, with 1/4 inch (6.3 mm) thick protective strip to cushion impact of bottom bar on counter top. Finish to match shutter curtain.
          10.Guide Assemblies: Guides shall consist of 13 gauge (0.086 inch minimum steel thickness) steel, formed from galvanized steel and finished to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          11.Jamb Construction: Steel jambs with self-tapping fasteners.
          12.Jamb Construction: Wood jambs with lag bolt fasteners.
          13.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          14.Jamb Construction: Non-masonry jambs for drywall or plaster.
          15.Wear Strips: Rolling counter shutter shall be furnished with wool pile wear strips inside the guides to reduce premature wear and noise.
          16.Counterbalance System:
          a.Headplates: Mounting brackets shall be made from 10 gauge galvanized steel plate and attached to the wall and guide.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion springs or tube motors.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Tube Motor: 115 volt single phase tube motor with two button constant pressure open-close operation.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          17.Enclosures:
          a.Hood: Square hood enclosure fabricated from 24 gauge steel, finish-painted to match curtain.
          b.Weight Counterbalance Cover: 24 gauge steel, finish-painted to match curtain.
          c.Headplate Cover: 24-gauge steel finish-painted to match the curtain.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          18.Locks: Furnish shutter system with the following:
          a.Locking Bar: For manual shutters and hand crank shutters, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Shutters: Provide interlock switch with locking bar.
          c.Cylinder Lock: For use with manual and hand crank operated shutters.
          d.Cylinder Lock for Motor Operated Shutters: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete DuraShutter Select if not required. DuraShutter Select for interior or exterior applications, maximum 20 feet wide and 8 feet high.
 
          B.DuraShutter Select as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete shutter operation not required.
          1)Provide shutters designed for manual operation.
          2)Provide shutters designed for hand crank operation.
          3)Provide shutters designed for tube motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Structural Performance Requirements:
          ** NOTE TO SPECIFIER ** Insert required wind load. p.s.f.
          a.Wind Loads: Uniform pressure of: ________ psf.
          ** NOTE TO SPECIFIER ** Delete curtain material not required.
          3.Curtain Material: Interlocking flat slats, extruded aluminum, 0.05 inch (1.3 mm) thick.
          4.Curtain Material: Interlocking flat slats, roll formed stainless steel, 22 gauge (0.030 inch) thick.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          5.Mounting: To face of wall on each side of shutter opening.
          6.Mounting: Between jambs of wall opening.
          7.Mounting: Integral frame, as follows:
          ** NOTE TO SPECIFIER ** Delete frame type not required.
          a.Painted Slip-in Frame: For use with a pre-existing finished opening.
          b.Painted Build-in Frame: For use with masonry wall construction.
          c.Stainless Steel Slip-in Frame: For use with a pre-existing finished opening.
          d.Stainless Steel Build-in Frame: For use with masonry wall construction.
          ** NOTE TO SPECIFIER ** Delete color and finish not required. If ArmorBrite retained, include color.
          8.Color and Finish: Mill finish.
          9.Color and Finish: Clear anodized.
          10.Color and Finish: Bronze anodized.
          11.Color and Finish: Stainless steel #4.
          12.Color and Finish: ArmorBrite Powdercoat.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          ** NOTE TO SPECIFIER ** Endlocks are available for stainless steel slats only.
          13.Endlocks: Lateral movement of the slats to be contained by means of zinc-plated stamped steel endlocks fastened to slat.
          14.Bottom Bar and Seal: Tubular type, with 1/4 inch (6.3 mm) thick protective strip to cushion impact of bottom bar on counter top. Finish to match shutter curtain.
          15.Guide Assemblies: Guide shall be provided in the same material and finish as the shutter curtain, and be fitted with removable curtain stop. Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          16.Jamb Construction: Steel jambs with self-tapping fasteners.
          17.Jamb Construction: Wood jambs with lag bolt fasteners.
          18.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          19.Jamb Construction: Non-masonry jambs for drywall or plaster.
          20.Wear Strips: Rolling counter shutter shall be furnished with wool pile wear strips inside the guides to reduce premature wear and noise.
          21.Counterbalance System:
          a.Headplates: Mounting brackets shall be made from 10 gauge galvanized steel plate and attached to the wall and guide.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion springs or tube motors.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Tube Motor: 115 volt single phase tube motor with two button constant pressure open-close operation.
          22.Enclosures:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs for hoods.
          a.Square Hood: Square hood enclosure fabricated from 0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          b.Square Hood: Square hood enclosure fabricated from 24 gauge stainless steel, #4 finish.
          c.Headplate Cover: As follows:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          1)0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          2)24 gauge stainless steel, #4 finish.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          23.Locks: Furnish shutter system with the following:
          a.Locking Bar: For manual shutters and hand crank shutters, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Shutters: Provide interlock switch with locking bar.
          c.Cylinder Lock: For use with manual and hand crank operated shutters.
          d.Cylinder Lock for Motor Operated Shutters: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete coiling grilles if not required.
 
          2.4COILING GRILLES
          ** NOTE TO SPECIFIER ** Delete DuraGrille Standard if not required. DuraGrille Standard for interior or exterior applications, maximum 30 feet in width and 24 feet in height.
 
          A.DuraGrille Standard as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete grille operation not required.
          1)Provide grilles designed for manual operation.
          2)Provide grilles designed for hand crank operation.
          3)Provide grilles designed for hand chain operation.
          4)Provide grilles designed for jackshaft motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the grille that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          ** NOTE TO SPECIFIER ** Delete grille patterns not required.
          2.Grille Pattern: Straight Pattern: Horizontal aluminum rods 5/16 inch (7.9 mm), spaced vertically at 2 inch (50.8 mm) O.C. with vertical link assemblies spaced horizontally at 6 inch (152.4 mm) O.C. Lateral movement of the vertical link assemblies to be contained by C-clips. Vertical link assemblies to be held together by brass eyelets.
          3.Grille Pattern: Straight Pattern: Horizontal aluminum rods 5/16 inch (7.9 mm) spaced vertically at 2 inch (50.8 mm) O.C. with vertical link assemblies spaced horizontally at 9 inch (228.6 mm) O.C. Lateral movement of the vertical link assemblies to be contained by C-clips. Vertical link assemblies to be held together by brass eyelets.
          4.Grille Pattern: Brick Pattern: Horizontal aluminum rods 5/16 inch (7.9 mm) spaced vertically at 2 inch (50.8 mm) O.C., with links spaced horizontally at 6 inch (152.4 mm) O.C. to form a brick pattern with aluminum spacers at the top and bottom of each link.
          5.Grille Pattern: Brick Pattern: Horizontal aluminum rods 5/16 inch (7.9 mm), spaced vertically at 2 inch (50.8 mm) O.C., with links spaced horizontally at 9 inch (228.6 mm) O.C. to form a brick pattern with aluminum spacers at the top and bottom of each link.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          6.Mounting: To face of wall on each side of grille opening.
          7.Mounting: Between jambs of wall opening.
          8.Color and Finish: All non-plated components of the grille shall receive one coat of rust-inhibitive primer. Curtain finish shall be as follows:
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          a.Mill finish aluminum.
          b.Bronze anodized.
          c.Clear anodized.
          9.Endlocks: Lateral movement of the slats to be contained by means of zinc-plated stamped steel endlocks fastened to slat.
          10.Bottom Bar: Bottom of curtain reinforced with extruded aluminum tubular bottom bar in the following finish:
          ** NOTE TO SPECIFIER ** Delete bottom bar finishes not required.
          a.Mill finish.
          b.Bronze anodized.
          c.Clear anodized.
          11.Guide Assemblies:
          ** NOTE TO SPECIFIER ** Delete material and finish not required.
          a.Extruded aluminum (6063-T5) with bronze anodized finish.
          b.Extruded aluminum (6063-T5) with clear anodized finish.
          ** NOTE TO SPECIFIER ** Delete guide attachments not required.
          c.The extruded aluminum guides will be attached to structural steel angles.
          d.The extruded aluminum guides will be attached to structural steel support tubes.
          e.The extruded aluminum guides will be attached directly to jambs.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          12.Jamb Construction: Steel jambs with self-tapping fasteners.
          13.Jamb Construction: Wood jambs with lag bolt fasteners.
          14.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          15.Jamb Construction: Non-masonry jambs for drywall or plaster.
          16.Wear Strips: Rolling counter grille shall be furnished with wool pile wear strips inside the guides to reduce premature wear and noise.
          17.Counterbalance System:
          a.Headplates: 3/16 inch (4.8 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          1)Standard.
          2)High cycle.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          18.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Round Hood: 0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          c.Square Hood: 24 gauge steel, finish-painted to match curtain.
          d.Square Hood: 0.04 inch (1.02 mm) thick aluminum, finished to match curtain.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          19.Locks: Furnish grille system with the following:
          a.Locking Bar: For manual grilles and grilles operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Grilles: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For grilles operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with manual, hand chain and hand crank operated grilles.
          e.Cylinder Lock for Motor Operated Grilles: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete coiling fire doors if not required.
 
          2.5COILING FIRE DOORS
          ** NOTE TO SPECIFIER ** Delete FireCoil Optima if not required. Size of FireCoil Optima doors is up to 28 feet in width and 26 feet in height.
 
          A.FireCoil Optima as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand crank operation.
          3)Provide doors designed for hand chain operation.
          4)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Fire Resistance Rating:
          ** NOTE TO SPECIFIER ** Delete ratings not required. Indicate fire rating on Door Schedule in drawings.
          a.Three-hour rating, tested and listed by Factory Mutual (FM).
          b.Four-hour rating, tested and classified by Underwriters Laboratories (UL).
          c.Four-hour rating, tested and classified by Canadian Underwriters Laboratories (C-UL).
          d.Four-hour rating, tested and listed by International Standards Organization (ISO 3008).
          e.Four-hour rating, tested and listed by British Standards (BS476).
          f.Four-hour rating, tested and listed by California State Fire Marshal (CSFM).
          g.Four-hour rating, tested and listed by City of New York Material and Equipment Acceptance (MEA).
          3.Curtain Material: Interlocking steel slats, 18 gauge (0.047 inch minimum steel thickness), roll-formed from commercial quality hot-dipped galvanized (G-90) steel in compliance with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete slat type not required.
          a.Slat Type: Flat slat.
          b.Slat Type: Large contour slat.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of door opening.
          5.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          6.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Tan finish is available in flat slats only.
          7.Color and Finish: One finish coat of tan polyester paint applied over one coat of white epoxy primer.
          8.Color and Finish: ArmorBrite Powdercoat.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          9.Color and Finish: Galvanized.
          10.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          11.Bottom Bar and Seal: Two roll-formed galvanized steel angles, minimum 2 inches by 2 inches by 3/16 inch (50.8 mm x 50.8 mm x 4.8 mm). Bottom bar shall receive one coat of rust-inhibitive primer.
          12.Curtain Wear Strips: Polyethylene tape (UHMW).
          13.Guide Assemblies: Three structural steel angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) and fitted with removable curtain stops. Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          14.Jamb Construction: Steel jambs with self-tapping fasteners.
          15.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          16.Weather Seal: Guide brush seal.
          17.Counterbalance System:
          a.Headplates: 1/4 inch (6 mm) steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion spring or weight counterbalance in following two paragraphs.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)SureTest weight counterbalance.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          18.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Headplate Cover: 24 gauge steel finish-painted to match curtain.
          c.Flame Baffle: Provide flame baffle to comply with listing agency.
          19.Release System:
          a.Descent Control: Rolling fire door operation mechanism shall be disengaged during automatic closing of the door. Descent of door under fire conditions shall be controlled by the following:
          ** NOTE TO SPECIFIER ** Delete controls not required.
          1)Mechanical Oscillating Governor.
          2)Sure Test Viscous Governor (weight counterbalance only).
          3)Quick Test Centrifugal Governor.
          b.Release Type: Automatic closing of rolling fire door under fire conditions to be initiated by the following:
          ** NOTE TO SPECIFIER ** Delete release mechanisms not required.
          1)Fusible links.
          2)Thermal-manual links.
          3)Electro-thermal manual links with junction box.
          4)Electro-thermal manual links without junction box.
          5)FireShield (weight counterbalance only).
          6)Solid State Fail Safe Units LM90 Model A.
          7)Solid State Fail Safe Units LM90 Model B.
          8)Solid State Fail Safe Units LM90 Model B2.
          9)Solid State Fail Safe Units LM90 Model C.
          c.Detection Type: Device used in conjunction with the release type to initiate the automatic closing of rolling fire door shall be the following:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs below.
          1)Ionization smoke detector.
          2)Photoelectronic with heat sensor detector.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          20.Locks: Furnish door system with the following:
          a.Locking Bar: For manual doors and doors operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For doors operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with manual, hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete FireCoil Standard if not required. FireCoil Standard maximum size to 20 feet in width and 26 feet in height with slat restrictions.
 
          B.FireCoil Standard as manufactured by Raynor Garage Doors.
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for manual operation.
          2)Provide doors designed for hand chain operation.
          3)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Fire Resistance Rating:
          ** NOTE TO SPECIFIER ** Delete ratings not required. Indicate fire rating on Door Schedule in drawings.
          a.Three-hour rating, tested and listed by Factory Mutual (FM).
          b.Four-hour rating, tested and classified by Underwriters Laboratories (UL).
          c.Four-hour rating, tested and classified by Canadian Underwriters Laboratories (C-UL).
          d.Four-hour rating, tested and listed by International Standards Organization (ISO 3008).
          e.Four-hour rating, tested and listed by British Standards (BS476).
          f.Four-hour rating, tested and listed by California State Fire Marshal (CSFM).
          g.Four-hour rating, tested and listed by City of New York Material and Equipment Acceptance (MEA).
          ** NOTE TO SPECIFIER ** Delete 22 gauge curtain material if not required.
          3.Curtain Material: Interlocking steel slats, 22 gauge (0.03 inch minimum steel thickness), roll-formed from commercial quality hot-dipped galvanized (G-90) steel in compliance with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete slat types not required.
          a.Slat Type: Flat slat.
          b.Slat Type: Small contour slat.
          c.Slat Type: Large contour slat.
          ** NOTE TO SPECIFIER ** Depending on size, some doors may require 20 gauge steel. Contact manufacturer for more information. Delete 20 gauge curtain material if not required.
          4.Curtain Material: Interlocking steel slats, 20 gauge (0.036 inch minimum steel thickness), roll-formed from commercial quality hot-dipped galvanized (G-90) steel in compliance with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete slat types not required.
          a.Slat Type: Flat slat.
          b.Slat Type: Small contour slat.
          c.Slat Type: Large contour slat.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          5.Mounting: To face of wall on each side of door opening.
          6.Mounting: Between jambs of wall opening.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          7.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** White finish is available in 22 gauge flat slats only.
          8.Color and Finish: One finish coat of white polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Tan finish is available in flat slats only.
          9.Color and Finish: One finish coat of tan polyester paint applied over one coat of white epoxy primer.
          ** NOTE TO SPECIFIER ** Galvanized finish is available in 22 gauge flat slats only.
          10.Color and Finish: Galvanized.
          11.Color and Finish: ArmorBrite Powdercoat applied over once coat of epoxy primer.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          12.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          13.Bottom Bar and Seal: Two roll-formed galvanized steel angles, minimum 2 inches by 2 inches by 3/16 inch (50.8 mm x 50.8 mm x 4.8 mm). Structural angle bottom bar to receive one coat of rust-inhibitive primer.
          14.Curtain Wear Strips: Polyethylene tape (UHMW).
          15.Guide Assemblies: Three structural steel angles, minimum 3 inches by 2 inches by 3/16 inch (76 mm by 50.8 mm by 4.8 mm) and fitted with removable curtain stops. Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete one jamb construction not required.
          16.Jamb Construction: Steel jambs with self-tapping fasteners.
          17.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          18.Jamb Construction: Non-masonry jambs for drywall or plaster.
          19.Weather Seal: Guide brush seal.
          20.Counterbalance System:
          a.Headplates: 1/4 inch (6.4 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Provide head plates with one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete either torsion spring or weight counterbalance in following two paragraphs.
          1)Torsion Spring: Oil-tempered counterbalance with helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Weight counterbalance.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements.
          21.Enclosures:
          a.Round Hood: 24 gauge steel, finish-painted to match curtain.
          b.Headplate Cover: 24 gauge steel finish-painted to match curtain.
          c.Flame Baffle: Provide flame baffle to comply with listing agency.
          22.Release System:
          a.Descent Control: Rolling fire door operation mechanism shall be disengaged during automatic closing of the door. Descent of door under fire conditions shall be controlled by the following:
          ** NOTE TO SPECIFIER ** Delete controls not required.
          1)Mechanical Oscillating Governor.
          ** NOTE TO SPECIFIER ** The following paragraph is for use with weight counterbalance assemblies, only.
          2)Viscous Governor (weight counterbalance only).
          3)Quick Test Centrifugal Governor.
          b.Release Type: Automatic closing of rolling fire door under fire conditions to be initiated by the following:
          ** NOTE TO SPECIFIER ** Delete release mechanisms not required.
          1)Fusible links.
          2)Thermal-manual links.
          3)Electro-thermal manual links with junction box.
          4)Electro-thermal manual links without junction box.
          ** NOTE TO SPECIFIER ** The following paragraph is for use with weight counterbalance assemblies, only.
          5)FireShield (weight counterbalance only).
          6)Solid State Fail Safe Unit LM90 Model A.
          7)Solid State Fail Safe Unit LM90 Model B.
          8)Solid State Fail Safe Unit LM90 Model B2.
          9)Solid State Fail Safe Unit LM90 Model C.
          c.Detection Type: Device used in conjunction with the release type to initiate the automatic closing of rolling fire door shall be the following:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs below.
          1)Ionization smoke detector.
          2)Photoelectronic with heat sensor detector.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          23.Locks: Furnish door system with the following:
          a.Locking Bar: For manual doors and doors operated with hand chain or hand crank, to receive padlock provided by Owner.
          b.Locking Bar for Motor Operated Doors: Provide interlock switch with locking bar.
          c.Hand Chain Lock: For doors operated with hand chain, to receive padlock provided by Owner.
          d.Cylinder Lock: For use with manual, hand chain and hand crank operated doors.
          e.Cylinder Lock for Motor Operated Doors: Provide interlock switch with cylinder lock.
          ** NOTE TO SPECIFIER ** Delete fire curtains if not required.
 
          2.6FIRE CURTAINS
          ** NOTE TO SPECIFIER ** Delete FireCurtain Standard if not required.
 
          A.FireCurtain Standard as manufactured by Raynor Garage Doors.
          1.Shutters:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete shutter operation not required.
          1)Provide shutters designed for manual operation.
          2)Provide shutters designed for hand crank operation.
          3)Provide shutters designed for tube motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the shutter that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Fire Resistance Rating:
          ** NOTE TO SPECIFIER ** Delete ratings not required. Indicate fire rating on Door Schedule in drawings.
          a.Three-hour rating, tested and listed by Factory Mutual (FM).
          b.Three-hour rating, tested and classified by Underwriters Laboratories (UL).
          c.Three-hour rating, tested and classified by Canadian Underwriters Laboratories (C-UL).
          3.Curtain Material: Interlocking flat slats, roll formed from 22 gauge (0.030 inch minimum steel thickness) commercial quality hot-dipped galvanized (G-90) steel complying with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of shutter opening.
          5.Mounting: Between jambs of wall opening.
          6.Integral Frame: Provide frame as follows:
          ** NOTE TO SPECIFIER ** Delete frame type not required.
          a.Painted Slip-in Frame: For use with a pre-existing finished opening.
          b.Painted Build-in Frame: For use with masonry wall construction.
          ** NOTE TO SPECIFIER ** Delete color and finish not required.
          7.Color and Finish: One finish coat of gray polyester paint applied over one coat of white epoxy primer.
          8.Color and Finish: ArmorBrite Powdercoat.
          ** NOTE TO SPECIFIER ** Insert color below.
          a.Color: ____________.
          9.Endlocks: Zinc-plated malleable cast iron endlocks fastened with two zinc-plated steel rivets.
          10.Bottom Bar and Seal: Roll-formed painted tubular steel type, with 1/4 inch (6.3 mm) thick protective strip to cushion impact of bottom bar on counter top. Finish to match shutter curtain.
          11.Guide Assemblies: Guides shall consist of 13 gauge (0.086 inch minimum steel thickness) steel, formed from galvanized steel and finished to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          12.Jamb Construction: Steel jambs with self-tapping fasteners.
          13.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          14.Jamb Construction: Non-masonry jambs for drywall or plaster.
          15.Counterbalance System:
          a.Headplates: Mounting brackets shall be made from 10 gauge galvanized steel plate and attached to the wall and guide.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete counterbalance not required.
          1)Torsion Spring: Oil-tempered helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Tube Motor: 115 volt single phase Raynor FireEclipse Tube Motor with two button constant pressure "open-close" operation.
          ** NOTE TO SPECIFIER ** Edit paragraph below to suit project requirements.
          16.Enclosures:
          a.Square Hood: 24 gauge steel, finish-painted to match curtain.
          b.Headplate Cover: 24 gauge steel finish-painted to match curtain.
          c.Flame Baffle: Provide flame baffle to comply with listing agency.
          17.Release System:
          a.Descent Control: Rolling fire counter shutter operation mechanism shall be disengaged during automatic closing of the shutter. Descent of shutter under fire conditions shall be controlled by a centrifugal governor.
          b.Release Type: Automatic closing of rolling fire shutter under fire conditions to be initiated by the following:
          ** NOTE TO SPECIFIER ** Delete release mechanisms not required.
          1)Fusible links.
          2)Thermal-manual links.
          3)Electro-thermal manual links with junction box.
          4)Electro-thermal manual links without junction box.
          5)LM90 Model A.
          ** NOTE TO SPECIFIER ** The following paragraph is an option for use with the FireEclipse tube motor, only.
          6)FireShield (for use with FireEclipse tube motor.)
          c.Detection Type: Device used in conjunction with the release type to initiate the automatic closing of rolling fire shutter shall be the following:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs below.
          1)Ionization smoke detector.
          2)Photoelectronic with heat sensor detector.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          18.Locks: Furnish counter shutter with the following:
          a.Locking Bar: For manual and hand crank shutters, to receive padlock provided by Owner.
          b.Cylinder Lock: For use with manual and hand crank operated shutters.
          ** NOTE TO SPECIFIER ** Delete FireCurtain Select if not required.
 
          B.FireCurtain Select as manufactured by Raynor Garage Doors.
          1.Shutter Operators:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete shutter operation not required.
          1)Provide shutters designed for manual operation.
          2)Provide shutters designed for hand crank operation.
          3)Provide shutters designed for tube motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the shutter that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Fire Resistance Rating:
          ** NOTE TO SPECIFIER ** Delete ratings not required. Indicate fire rating on Door Schedule in drawings.
          a.Three-hour rating, tested and listed by Factory Mutual (FM).
          b.Three-hour rating, tested and classified by Underwriters Laboratories (UL).
          c.Three-hour rating, tested and classified by Canadian Underwriters Laboratories (C-UL).
          3.Curtain Material: Interlocking flat slats, roll formed from 22 gauge (0.030 inch minimum steel thickness) commercial quality hot-dipped galvanized (G-90) steel complying with ASTM A-653.
          ** NOTE TO SPECIFIER ** Delete mounting not required.
          4.Mounting: To face of wall on each side of shutter opening.
          5.Mounting: Between jambs of wall opening.
          6.Integral Frame: Provide frame as follows:
          ** NOTE TO SPECIFIER ** Delete frame type not required.
          a.Painted Slip-in Frame: For use with a pre-existing finished opening.
          b.Painted Build-in Frame: For use with masonry wall construction.
          c.Stainless Steel Slip-in Frame: For use with a pre-existing finished opening.
          d.Stainless Steel Build-in Frame: For use with masonry wall construction.
          7.Color and Finish: Stainless steel #4 finish.
          8.Endlocks: Zinc-plated stamped steel endlocks fastened to slat.
          9.Bottom Bar and Seal: Roll-formed tubular Stainless Steel #4 type, with 1/4 inch (6.3 mm) thick protective strip to cushion impact of bottom bar on counter top. Finish to match shutter curtain.
          10.Guide Assemblies: Guide shall be provided in the same material and finish as the shutter curtain, and be fitted with removable curtain stop.
          . ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          11.Jamb Construction: Steel jambs with self-tapping fasteners.
          12.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          13.Jamb Construction: Non-masonry jambs for drywall or plaster.
          14.Counterbalance System:
          a.Headplates: Mounting brackets shall be made from 10 gauge galvanized steel plate and attached to the wall and guide.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs describing counterbalance options.
          1)Torsion Spring: Oil-tempered helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Tube Motor: 115 volt single phase Raynor FireEclipse Tube Motor with two button constant pressure "open-close" operation.
          ** NOTE TO SPECIFIER ** Edit paragraph below to suit project requirements.
          15.Enclosures:
          a.Square Hood: 24 gauge stainless steel, finished to match curtain.
          b.Headplate Cover: 24 gauge steel finish-painted to match curtain.
          c.Flame Baffle: Provide flame baffle to comply with listing agency.
          16.Release System:
          a.Descent Control: Rolling fire counter shutter operation mechanism shall be disengaged during automatic closing of the shutter. Descent of shutter under fire conditions shall be controlled by a centrifugal governor.
          b.Release Type: Automatic closing of rolling fire shutter under fire conditions to be initiated by the following:
          ** NOTE TO SPECIFIER ** Delete release mechanisms not required.
          1)Fusible links.
          2)Thermal-manual links.
          3)Electro-thermal manual links with junction box.
          4)Electro-thermal manual links without junction box.
          5)LM90 Model A.
          ** NOTE TO SPECIFIER ** The following paragraph is an option for use with the FireEclipse tube motor, only.
          6)FireShield (for use with FireEclipse tube motor.)
          c.Detection Type: Device used in conjunction with the release type to initiate the automatic closing of rolling fire shutter shall be the following:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs below.
          1)Ionization smoke detector.
          2)Photoelectronic with heat sensor detector.
          ** NOTE TO SPECIFIER ** Revise or delete paragraphs below to suit project requirements.
          17.Locks: Furnish counter shutter with the following:
          a.Locking Bar: For manual and hand crank shutters, to receive padlock provided by Owner.
          b.Cylinder Lock: For use with manual and hand crank operated shutters.
          ** NOTE TO SPECIFIER ** Delete Fabricoil Basic Doors if not required. Fabricoil Basic doors for interior or exterior application in maximum size of 12 feet by 14 feet. Not for high negative pressure installations.
 
          2.7TRAFFIC DOORS
 
          A.Fabricoil Basic Doors as manufactured by Raynor Garage Doors:
          1.Doors:
          a.Operation:
          ** NOTE TO SPECIFIER ** Delete door operation not required.
          1)Provide doors designed for hand chain operation.
          2)Provide doors designed for electric motor operation.
          b.Drive Orientation: Orient the drive from the following side when facing the side of the door that has the counterbalance or hood exposed:
          ** NOTE TO SPECIFIER ** Delete one of the following paragraphs.
          1)Left-hand.
          2)Right-hand.
          2.Curtain Material: One-ply PVC fabric.
          3.Mounting: To face of wall on each side of shutter opening.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs for color.
          4.Color: Orange.
          5.Color: Blue.
          6.Bottom Bar and Seal: Hot-rolled steel angle, minimum 2 inches by 2 inches by 3/16 inch (50.8 mm x 50.8 mm x 4.8 mm). Bottom bar contained within guides by means of UHMW breakaway tabs. Bottom of door equipped with yellow electric sensing edge. Bottom bar shall be finished with rust inhibitive primer.
          a.ArmorBrite Powdercoat finish. Color _________________.
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no vision panels. Number and locations of vision panels to comply with door elevation drawings.
          7.Vision Panels: Clear PVC, 24 inches (610 mm) high, full width of curtain.
          ** NOTE TO SPECIFIER ** Delete curtain wear strips if not required.
          8.Curtain Wear Strips: Polyethylene tape (UHMW).
          9.Guide Assemblies: Fabricate from hot-rolled steel angle, minimum thickness of 3/16 inch (4.8 mm). Finish to match curtain.
          ** NOTE TO SPECIFIER ** Delete jamb construction not required.
          10.Jamb Construction: Steel jambs with self-tapping fasteners.
          11.Jamb Construction: Wood jambs with lag bolt fasteners.
          12.Jamb Construction: Masonry jambs with anchor bolt fasteners.
          13.Guide Brush Seal: 2 inch brush in aluminum retainer along vertical edges.
          14.Header Brush Seal: 1-3/4 inch brush in aluminum retainer along top horizontal header.
          ** NOTE TO SPECIFIER ** Delete bottom astragal not required.
          15.Bottom Astragal: Looped rubber astragal.
          16.Bottom Astragal: Yellow wireless electric reversing edge.
          17.Counterbalance System:
          a.Headplates: 3/16 inch (4.8 mm), minimum, steel plate, attached to wall angle of guide assembly with 1/2 inch (12.7 mm) diameter class 5 case hardened bolts. Inside of drive bracket fitted with sealed ball bearing. Head plates to receive one coat of rust-inhibitive primer.
          b.Barrel: Minimum 4-1/2 inches (114.3 mm) O.D. and 0.120 inch (3.1 mm) wall thickness structural steel pipe. Deflection of pipe under full load shall not exceed 0.03 inch (0.8 mm) per foot of span.
          c.Counterbalance: Provide counterbalance mechanism as follows:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs describing counterbalance options.
          1)Torsion Spring: Hand Chain operated rolling traffic door shall be counterbalanced by oil-tempered helical torsion springs, grease packed and mounted on a continuous steel torsion shaft.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a)Standard.
          b)High cycle.
          2)Motor: Electrically operated rolling traffic door shall be counterbalanced by means of the electric motor.
          ** NOTE TO SPECIFIER ** Edit or delete paragraph below to suit project requirements for enclosures.
          18.Enclosures:
          a.Round Hood: 24 gauge steel.
          ** NOTE TO SPECIFIER ** Delete finishes not required. If retaining ArmorBrite, insert color.
          1)Finish: Gray paint.
          2)Finish: Tan paint.
          3)Finish: ArmorBrite Powdercoat finish. Color ____________.
          4)Finish: Galvanized.
          b.Square Hood: 24 gauge steel.
          ** NOTE TO SPECIFIER ** Delete finishes not required. If retaining ArmorBrite, insert color.
          1)Finish: Gray paint.
          2)Finish: Tan paint.
          3)Finish: ArmorBrite Powdercoat finish. Color ____________.
          4)Finish: Galvanized.
          c.Headplate Cover: 24 gauge steel, finish-painted to match curtain.
          d.Motor Cover: 24 gauge steel, finish-painted to match curtain.
          19.Locks: Dual slide bolts.
          ** NOTE TO SPECIFIER ** Delete electric operators if not required.
 
          2.8OPERATORS
          ** NOTE TO SPECIFIER ** PowerHoist Optima operators (relay logic) feature a heavy-duty gear drive running in oil for high reliability and efficient operation. They are designed for larger sectional doors and higher cycle applications. Delete if not required.
 
          A.Raynor PowerHoist Optima with Contactor Style Motor Starter:
          1.Type: Jackshaft with manual chain hoist.
          ** NOTE TO SPECIFIER ** Delete rating not required.
          2.Motor Horsepower Rating: Continuous 1/2 HP.
          3.Motor Horsepower Rating: Continuous 3/4 HP.
          4.Motor Horsepower Rating: Continuous 1 HP.
          5.Motor Horsepower Rating: Continuous 1-1/2 HP.
          6.Motor Horsepower Rating: Continuous 2 HP.
          ** NOTE TO SPECIFIER ** Delete electrical not required.
          7.Electrical Requirements: 115 volt single phase.
          8.Electrical Requirements: 230 volt single phase.
          9.Electrical Requirements: 230 volt three phase.
          10.Electrical Requirements: 460 volt three phase.
          11.Duty Cycle: 30 cycles/hour.
          12.Control Wiring: 24 volt control with provisions for connection of safety edge to reverse and external radio control hook-up.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
          b.Custom wiring, consult factory.
          ** NOTE TO SPECIFIER ** PowerHoist Standard (relay logic) belt-drive operators are designed for medium- to high-cycle applications and for normal- to large-size sectional doors. Delete if not required.
 
          B.Raynor PowerHoist Standard:
          ** NOTE TO SPECIFIER ** Delete type not required.
          1.Type: Jackshaft.
          2.Type: Jackshaft with manual chain hoist.
          ** NOTE TO SPECIFIER ** Delete rating not required.
          3.Motor Horsepower Rating: Continuous 1/3 HP.
          4.Motor Horsepower Rating: Continuous 1/2 HP.
          5.Motor Horsepower Rating: Continuous 3/4 HP.
          ** NOTE TO SPECIFIER ** Delete electrical not required.
          6.Electrical Requirements: 115 volt single phase.
          7.Electrical Requirements: 230 volt single phase.
          8.Electrical Requirements: 230 volt three phase.
          9.Electrical Requirements: 460 volt three phase.
          10.Duty Cycle: 30 cycles/hour.
          11.Control Wiring: 24 volt control with provisions for connection of safety edge to reverse and external radio control hook-up.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
          b.Custom wiring, consult factory.
          ** NOTE TO SPECIFIER ** PowerHoist Basic (relay logic) belt drive operators are designed for operating sectional or rolling steel doors up to 14 feet high in light duty applications. Delete if not required.
 
          C.Raynor PowerHoist Basic with Relay Style Motor Controller:
          ** NOTE TO SPECIFIER ** Delete type not required.
          1.Type: Jackshaft.
          2.Type: Jackshaft with manual chain hoist.
          3.Motor Horsepower Rating: Intermittent 1/2 HP.
          4.Electrical Requirements: 115 volt single phase.
          5.Duty Cycle: 10 cycles/hour.
          6.Control Wiring: 24 volt control with provisions for connection of safety edge to reverse, and external radio control hook-up.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
          ** NOTE TO SPECIFIER ** ControlHoist Optima operators (solid state) feature a heavy-duty gear drive running in oil for high reliability and efficient operation. They are designed for larger sectional doors and higher cycle applications.
 
          D.Raynor ControlHoist Optima with Solid State Motor Controller:
          1.Type: Jackshaft with manual chain hoist.
          2.Motor Horsepower Rating: Continuous 1/2 HP.
          3.Motor Horsepower Rating: Continuous 3/4 HP.
          4.Motor Horsepower Rating: Continuous 1 HP.
          5.Motor Horsepower Rating: Continuous 1-1/2 HP.
          6.Motor Horsepower Rating: Continuous 2 HP.
          ** NOTE TO SPECIFIER ** Delete electrical not required.
          7.Electrical Requirements: 115 volt single phase.
          8.Electrical Requirements: 230 volt single phase.
          9.Electrical Requirements: 230 volt three phase.
          10.Electrical Requirements: 460 volt three phase.
          11.Duty Cycle: 30 cycles/hour.
          12.Control Wiring: Solid state 24 volt control with provisions to select up to 6 standard wiring types plus delay on reverse, mid stop, maximum run timer, and door lock feature.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
          b.Custom wiring, consult factory.
          ** NOTE TO SPECIFIER ** ControlHoist Standard belt-drive operators are designed for medium- to high-cycle applications and for normal- to large-size sectional doors.
 
          E.Raynor ControlHoist Standard with Solid State Motor Controller:
          ** NOTE TO SPECIFIER ** Delete type not required.
          1.Type: Jackshaft.
          2.Type: Jackshaft with manual chain hoist.
          ** NOTE TO SPECIFIER ** Delete rating not required.
          3.Motor Horsepower Rating: Continuous 1/3 HP.
          4.Motor Horsepower Rating: Continuous 1/2 HP.
          5.Motor Horsepower Rating: Continuous 3/4 HP.
          6.Electrical Requirements: 115 volt single phase.
          7.Electrical Requirements: 230 volt single phase.
          8.Electrical Requirements: 230 volt three phase.
          9.Electrical Requirements: 460 volt three phase.
          10.Duty Cycle: 30 cycles/hour.
          11.Control Wiring: Solid state 24 volt control with provisions to select up to 6 standard wiring types plus delay on reverse, mid stop, maximum run timer.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
          b.Custom wiring, consult factory.
          ** NOTE TO SPECIFIER ** ControlHoist BASIC belt drive operators are designed for operating sectional or rolling steel doors up to 14 feet high in light duty applications.
 
          F.Raynor ControlHoist BASIC with Solid State Motor Controller:
          ** NOTE TO SPECIFIER ** Delete type not required.
          1.Type: Jackshaft.
          2.Type: Jackshaft with manual chain hoist.
          3.Motor Horsepower Rating: Intermittent 1/2 HP.
          4.Electrical Requirements: 115 volt single phase.
          5.Duty Cycle: 10 cycles/hour.
          6.Control Wiring: Solid state 24 volt control with provisions to select up to 4 standard wiring types plus maximum run timer and provisions for connection of a separate delayed light.
          ** NOTE TO SPECIFIER ** Delete control not required.
          a.Three button momentary contact "open-close-stop".
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared. Verify that site conditions are acceptable for installation of doors, operators, controls and accessories. Ensure that openings are square, flush and plumb.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
 
          B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
          ** NOTE TO SPECIFIER ** Coordinate article below with manufacturer's recommended installation requirements. All door installations should be performed by an authorized Raynor Dealer. Consult Raynor to obtain local dealer contact information. Preparation of door openings should comply with submitted Raynor requirements.
 
          3.3INSTALLATION
 
          A.General: Install door, track and operating equipment complete with all necessary accessories and hardware according to shop drawings, manufacturer's instructions.
 
          B.Lubricate bearings and sliding parts, assure weather tight fit around door perimeter and adjust doors for proper operation, balance, clearance and similar requirements.
 
          3.4PROTECTION
 
          A.Clean installed products in accordance with manufacturer's instructions prior to Owner's acceptance. Remove and legally dispose of construction debris from project site.
 
          B.Remove temporary coverings and protection of adjacent work areas. Repair or replace installed products damaged prior to or during installation.
 
          C.Protect installed products until completion of project.
 
          D.Touch-up, repair or replace damaged products before Substantial Completion.
          ** NOTE TO SPECIFIER ** Retain, edit or delete paragraph below to suit project requirements and specifier practice. Specify the tests and inspections required for installed or completed work. Establish number and duration of periodic site visits with Owner and manufacturer, and specify below. Consult with manufacturer for services required. Coordinate paragraph below with Division 1 Quality Assurance Section and Part 1 Quality Assurance Submittals.
 
          3.5FIELD QUALITY CONTROL
 
          A.Manufacturer's Field Services: At Owner's request, provide manufacturer's field service consisting of product installation and use recommendations, and periodic site visits to observe and ensure product installation is done in accordance with manufacturer's recommendations.
 
         
END OF SECTION