MasterFormat: 95
SpecWizard: customize this spec    Download this Hurricane Resistant Doors Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Hurd Windows & Doors, Inc. Hurricane Resistant Doors
 
         
SECTION 08396
 
         
HURRICANE RESISTANT DOORS
 
         
          ** NOTE TO SPECIFIER ** Hurd Windows & Doors, Inc.; Wood, aluminum clad and vinyl clad windows, doors and sliding patio doors.
.
This section is based on the products of Hurd Windows & Doors, Inc., which is located at:
575 S. Whelen Ave.
Medford, WI 54451
Toll Free Tel: 800-2BE-HURD
Tel: 715-748-2011
Fax: 715-748-6043
Email: request info
Web: www.hurd.com
[ Click Here ] for additional information.

The only thing we can never be sure of is the weather. We build our windows and doors to protect you from Mother Nature's whims. That's why we're proud to be an Energy Star Partner, dedicated to designing, building and promoting energy efficiency into our windows and doors. For more information about the Energy Star® rating and what it means, visit www.energystar.gov.

So, that's all fine and well, but specifically, how good is a Hurd window? Well, the National Fenestration Rating Council has established testing criteria that determine window performance in three areas: thermal performance, solar heat gain and visible light transmittance. Now, when you want to find out how good a Hurd window is, all you have to do is check the NFRC label on them.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Storm resistant wood doors, hardware, sidelights and trim.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 01330 - Submittal Procedures.
 
          B.Section 01600 - Product Requirements.
 
          C.Section 06100 - Rough Carpentry.
 
          D.Section 06200 - Finish Carpentry.
 
          E.Section 07900 - Joint Sealers.
 
          F.Section 08810 - Glass and Glazing.
 
          G.Section 09900 - Painting.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.AAMA - American Architectural Manufactures Association:
          1.AAMA/NWWDA 101/I.S. 2-97 - Voluntary Standard for Aluminum and Poly Vinyl Chloride (PVC) Wood Windows and Glass Doors.
          2.AAMA/WDMA/CSA 101./I.S.2/A440-05 - Standard/Specification for Windows, Doors and Unit Skylights.
          3.AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels.
          4.AAMA 2604 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels.
          5.AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels.
 
          B.ASTM - American Society for Testing and Materials:
          1.ASTM C1036 - Standard Specification for Flat Glass.
          2.ASTM C1048 - Standard Specifications for Heat-Treated Glass - Kind HS, Kind FT Coated and Uncoated Glass.
          3.ASTM E283 - Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Difference Across the Specimen.
          4.ASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference.
          5.ASTM E547 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference.
          6.ASTM E2188 - Standard Test Method for Insulating Glass Unit Performance.
          7.ASTM E2189 - Standard Test Method for Testing Resistance to Fogging in insulated Glass.
 
          C.IGCC - Insulated Glass Certification Council.
 
          D.NFRC - National Fenestration Rating Council:
          1.NFRC -100 - Procedure for Determining Fenestration Product U - Factors.
          2.NFRC - 200 - Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence.
          3.NFRC - 500 - Procedure for Determining Fenestration Product Condensation Resistance Values.
 
          E.NWWDA - National Wood Window & Door Association:
          1.AAMA/NWWDA 101/I.S. 2-97 - Voluntary Standard for Aluminum and Poly Vinyl Chloride (PVC) Wood Windows and Doors.
 
          F.SMA - Screen Manufacturers Association:
          1.SMA 1201- Specifications for Insect Screens for Windows, Sliding doors and Swinging Doors.
 
          G.WDMA - Windows and Door Manufacturers Association:
          1.WDMA I.S.4 - Industry Standard for Water-Repellent Preservative Non -Pressure Treatment for Millwork.
 
          H.FBC TAS 201 - Impact Test Procedures; Florida Building Code; l994.
 
          I.FBC TAS 202 - Criteria for Testing Impact and Non Impact Resistant Building Envelope Components Using Uniform Static Air Pressure; Florida Building Code; 1994.
 
          J.FBC TAS 203 - Criteria for Testing Products Subject To Cyclic Wind Pressure Loading; Florida Building Code; 1994.
 
          1.4DEFINITIONS
 
          A.Performance Class Designations:
          1.R (Residential): Commonly used in one and two-family dwellings.
          2.LC (Light Commercial): Commonly used in low-rise multi dwellings, low rise professional offices, libraries and low-rise motels.
          3.C (Commercial): Commonly used in lighter use industrial building and factories, hotels and retail sales buildings.
          4.HC (Heavy Commercial): Commonly used in hospitals, schools, institutions, dormitories, government or public buildings, and other buildings where heavy use of fenestration products is expected. Also commonly used on mid-rise buildings with increased loading requirements.
          5.AW (Architectural): Commonly used in hospitals, schools, institutions, and public buildings, or on high-rise and mid-rise buildings to meet increased loading requirements. Also commonly used in buildings where possible misuse of the fenestration products is expected.
 
          B.Performance Grade Designations: Actual design pressure that is designated by a number following the type and class designation in pounds force per square foot.
 
          C.Minimum test size: The smallest size unit permitted for performance class (gateway test size). Products must be tested at the minimum test size or at a size larger than minimum test size to comply with requirements for performance class.
 
          1.5PERFORMANCE REQUIREMENTS.
 
          A.Air infiltration (air leakage) shall not exceed the following when tested at 1.57 psf (75 Pa) when tested in accordance with ASTM E283: 0.30 cfm/sf (.013 L/s per square meter) of frame.
 
          B.Water Penetration Resistance: There shall be no water penetration when tested at the desired/ specified pressure in accordance with ASTM E547.
 
          C.Structural Load Testing: Product shall meet the damaged and permanent deflection pass/fail criteria as stated in AAMA/NWWDA 101/I.S. 2-97 or AAMA/WDMA/CSA 101 I.S.2/A440-05 when tested in accordance with ASTM E330.
 
          1.6SUBMITTALS
 
          A.Shop Drawings: Submit under provisions of Section 01300.
 
          B.Product Data: Submit manufacturer's catalog data on each product to be used. Include glazing system and two complete sets of color chips representing manufacturer's full range of available colors.
 
          C.Samples: Submit corner section. Include glazing system and two complete sets of color chips representing manufacturer's full range of available colors.
 
          D.Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door; construction details, including those for stiles, rails, panels, moldings and other pertinent construction.
 
          1.7QUALITY ASSURANCE
 
          A.Manufacturer Qualifications:
          1.A manufacturer capable of fabricating wood doors that meet or exceed performance requirements indicated and of documenting this performance by inclusion in lists and by labels, test reports, and calculations.
 
          B.Installer Qualifications:
          1.An installer acceptable to wood door manufacturer for installation of units required for this Project.
 
          C.Product Requirements:
          1.Comply with AAMA/WDMA 101/I.S.2/NAFS, "North American Fenestration Standard Voluntary Performance Specification for Windows, Skylights and Glass Doors," for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated.
          2.Comply with published recommendations of glass manufacturers and with GANA's "Glazing Manual" unless more stringent requirements are indicated.
          3.Construction shall resist Wind-borne Debris Regions for wind zones per ASCE 7-98.
          4.Construction shall resist hurricane wind speeds for category hurricanes per National Hurricane Center standards.
 
          1.8DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging in an upright position off the ground in a clean, dry area until ready for installation.
 
          B.Prime or seal wood surfaces if more that 30 days between delivery and installation.
 
          1.9PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          B.Field Measurements: Verify wood window openings by field measurements before fabrication and indicate measurements on Shop Drawings.
 
          1.10WARRANTY
 
          A.Warranty Period:
          ** NOTE TO SPECIFIER ** Delete warranty period not required or available for product specified.
          1.Two Year Warranty: Glass Stress Cracks.
          a.Refer to Hurd Windows and Doors, Inc. Product Warranty for details and exclusions.
          2.Ten Years Limited Life Time Warranty: Non-Glass Components.
          a.Refer to Hurd Windows and Doors, 1nc. Product Warranty for details and exclusions.
          3.Twenty Year Limited Life Time Warranty: Insulated Glass.
          a.Refer to Hurd Windows and Doors, Inc. Product Warranty for details and exclusions.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Hurd Windows & Doors, Inc., which is located at: 575 S. Whelen Ave. ; Medford, WI 54451; Toll Free Tel: 800-2BE-HURD; Tel: 715-748-2011; Fax: 715-748-6043; Email: request info; Web: www.hurd.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
          2.2APPLICATIONS/SCOPE
 
          A.Refer to Door Schedule on the drawings for application and location.
          ** NOTE TO SPECIFIER ** Delete French sliding door if not required.
 
          B.French Sliding Patio Door:
          ** NOTE TO SPECIFIER ** This product NOT approved for Dade County. Delete if not required.
          1.Aluminum Clad Energy Saver French Sliding Patio Doors as manufactured by Hurd Windows and Doors Inc.
          a.Performance: +55/-65 Wind Zone 4, Missile Level D, maximum size 40 inches (1016 mm) by 82-1/4 inches (2089 mm). Glass Type DD 1.04 inches Insulated – 6mm Temp Interior Lite; .438 inch Air Space; 8.6 mm Annealed Laminated (3 mm AN; .090 inch PVB; 3mm AN Exterior Lite).
          ** NOTE TO SPECIFIER ** This product NOT approved for Dade County. Delete if not required.
          2.Aluminum Clad Energy Saver Outswing French Patio Doors as manufactured by Windows and Doors, Inc. FeelSafe Insulated Glass Product.
          a.Performance: +55/-70. Wind Zone 4, Missile Level D, maximum size 28 inches (711 mm) by 82-1/4 inches (2089 mm). Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Laminated (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN).
          b.Performance: +55/-65. Wind Zone 4, Missile Level D, maximum size 40 inches (1016 mm) by 82-1/4 inches (2089 mm). Glass Type C Monolithic 11.9mm (7/6 inches) Annealed Laminated (5mm AN; 0.75 inches Storm Interlayer; 5mm AN).
          3.Jamb width 4 9/16 inches (116mm) - Clad.
          4.Weatherproofing: Weatherstrip at meeting stiles, head, sides and bottom.
          5.Fully adjustable tandem steel ball bearing rollers on operating door panel.
          6.Simple door panel removal.
          7.Pultruded fiberglass sill design.
          8.Cam lock and keeper located on meeting stiles.
          9.Zinc die-cast Steel exterior sash pull located on operable sash.
          10.Security foot bolt.
          ** NOTE TO SPECIFIER ** Delete finish not required.
          a.Bronze.
          b.White.
          ** NOTE TO SPECIFIER ** Delete extension jamb not required.
          11.Extension Jambs: 4-3/4 inches (120 mm).
          12.Extension Jambs: 5 inches (127 mm).
          13.Extension Jambs: 5-1/8 inches (130 mm).
          14.Extension Jambs: 5-5/16 inches (135 mm).
          15.Extension Jambs: 6-7/16 inches (138 mm).
          16.Extension Jambs: 6-9/16 inches (141 mm).
          17.Extension Jambs: 6-3/4 inches (171 mm).
          18.Extension Jambs: 7 inches (178 mm).
          19.Extension Jambs: 7-1/8 inches (181 mm).
          20.Extension Jambs: 7-1/4 inches (184 mm).
          21.Extension Jambs: 7-3/8 inches (187 mm).
          22.Extension Jambs: Width as indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete if not required.
          23.Extruded aluminum drip cap.
          ** NOTE TO SPECIFIER ** Delete outswing French patio door if not required.
 
          C.Outswing French Patio Door:
          ** NOTE TO SPECIFIER ** Delete door type not required.
          1.Aluminum Clad Classic Outswing French Patio Doors as manufactured by Windows and Doors, Inc. FeelSafe Insulated Glass Product.
          a.Performance: +55/-55 Wind Zone 4, Missile Level, maximum size 36 inches (914 mm) by 96 inches (2438 mm). Glass Type AA 15/16 inch Insulated – 3mm Temp Interior Lite; .438 inch Air Space; 8.6 mm Annealed Laminated (3mm AN; .090 inch Saflex PVB; 3mm AN Ext. Lite).
          ** NOTE TO SPECIFIER ** This product NOT approved for Dade County. Delete if not required.
          2.Aluminum Clad Classic Outswing French Patio Doors as manufactured by Windows and Doors, Inc. FeelSafe Monolithic Product.
          a.Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 36 inches (914 mm) by 96 inches (2438 mm). Glass Type FF 1.076 inch Insulated – 3mm Temp Interior Lite; .438 inch Air Space; 12.1mm Annealed Laminated (5mm AN; .100” HPJ; 5mm AN Ext. Lite).
          3.Aluminum Clad Classic Outswing French Patio Doors as manufactured by Windows and Doors, Inc. FeelSafe Monolithic Product.
          1Performance: +70/-70, maximum size 36 inches (914 mm) by 96 inches (2438 mm). Glass Type D Monolithic 12.17mm (7/16 inches) Annealed Laminated (5mm AN; .100 HPJ Interlayer; 5mm AN).
          ** NOTE TO SPECIFIER ** This product NOT approved for Dade County. Delete if not required.
          4.Aluminum Clad Energy Saver Outswing French Patio Doors as manufactured by Windows and Doors, Inc. FeelSafe Monolithic Product.
          a.Performance: +70/-70, maximum size 36 inches (914 mm) by 96 inches (2438 mm). Glass Type D Monolithic 12.17 mm (7/17 inches) Annealed Laminated (5 mm AN; .100 HPJ Interlayer; 5mm AN).
          5.Jamb width 4-9/16 inches (116 mm).
          6.Weatherproofing: Perimeter weatherstrip on operable and fixed panels.
          7.Sash profile 4-1/2 inches (114 mm).
          8.Bottom rail profile 7-1/2 inches (191 mm) or 9-1/2 inches (243 mm) - Clad.
          9.Pultruded fiberglass sill design.
          10.Butt hinge system
          11.Mortised lock and key deadbolt with 2-3/8 inches (60 mm) back set.
          ** NOTE TO SPECIFIER ** Five point locking lever is standard on all heights - Clad.
          12.Five point locking lever.
          ** NOTE TO SPECIFIER ** Delete jamb type not required.
          13.Extension jambs: 4-3/4 inches (120 mm).
          14.Extension jambs: 5 inches (127 mm).
          15.Extension jambs: 5-1/8 inches (130 mm).
          16.Extension jambs: 5-5/16 inches (135 mm).
          17.Extension jambs: 6-7/16 inches (138 mm).
          18.Extension jambs: 6-9/16 inches (141 mm).
          19.Extension jambs: 6-9/16 inches (141 mm). Clad sill nosing applied.
          20.Extension Jambs: 6-3/4 inches (171 mm).
          21.Extension Jambs: 7 inches (178mm)
          22.Extension Jambs: 7-1/8 inches (181 mm).
          23.Extension Jambs: 7-1/4 inches (184 mm).
          24.Extension Jambs: 7-3/8 inches (187 mm).
          25.Extension Jambs: Width as indicated on Drawings.
          ** NOTE TO SPECIFIER ** Delete if not required.
          26.Extruded drip cap.
          27.Aluminum structural nailing fin.
          ** NOTE TO SPECIFIER ** Delete height not required.
 
          D.Height: 6 feet 10 inches (2083 mm) height.
 
          E.Height: 7 feet 2 inches (2184 mm) height panels.
 
          F.Height: 8 feet 0 inches (2438 mm) height panels.
          ** NOTE TO SPECIFIER ** Delete screen if not required.
 
          G.Insect Screen: Extruded-aluminum or formed-tubular-aluminum members, mesh fabric.
          1.Frame Color: Match cladding color.
          ** NOTE TO SPECIFIER ** Delete mesh not required.
          2.Fiberglass charcoal colored mesh.
          3.Aluminum mesh.
          ** NOTE TO SPECIFIER ** For Sliding, Sliding French, and Inswing Doors. No screen available for outswing doors. Delete if not required.
          4.Hinged aluminum storm/ screen door.
 
          2.3GLAZING
 
          A.Factory-Glazed Fabrication: Comply with requirements of Section 08810 and with AAMA/WDMA 101/I.S.2/NAFS.
          ** NOTE TO SPECIFIER ** Tempering for safety glazing. Delete if not required.
          1.Safety Glass: Provide laminated and tempered products complying with testing requirements in 16 CFR 1201, for Category II materials.
          ** NOTE TO SPECIFIER ** Delete glazing not required.
 
          B.Glass Type: Hurd FeelSafe Laminated Insulated.
          ** NOTE TO SPECIFIER ** Delete color not required.
          1.Color: Clear.
          2.Color: Bronze.
          3.Color: Gray.
          4.Color: Green.
          5.Color: Obscure - White Laminated.
 
          C.Glass Type: Hurd FeelSafe Laminated Low E Insulated.
          ** NOTE TO SPECIFIER ** Delete color not required.
          1.Color: Clear.
          2.Color: Bronze.
          3.Color: Gray.
          4.Color: Green.
 
          D.Glass Type: Hurd FeelSafe Laminated.
          1.Color: Clear.
          2.Color: Bronze.
          3.Color: Gray.
          4.Color: Obscure - White Laminated.
          ** NOTE TO SPECIFIER ** Surround only for removable grilles. Delete grille type and design not required.
 
          E.Grille Type: Interior removable with Queen Anne design.
 
          F.Grille Type: Interior removable with Rectangular design.
 
          G.Grille Type: Interior removable with custom design. Refer to drawings.
          ** NOTE TO SPECIFIER ** Airspace design for laminated insulated design only. Available only on Hurd FeelSafe Laminated Insulated Glass. Delete grille type and design not required.
 
          H.Grille Type: Within airspace of insulated glass units with Queen Anne design.
          ** NOTE TO SPECIFIER ** Airspace design for laminated insulated design only. Available only on Hurd FeelSafe Laminated Insulated Glass. Delete grille type and design not required.
 
          I.Grille Type: Within airspace of insulated glass units with Rectangular design.
          ** NOTE TO SPECIFIER ** Airspace design for laminated insulated design only. Available only on Hurd FeelSafe Laminated Insulated Glass. Delete grille type and design not required.
 
          J.Grille Type: Within airspace of insulated glass units with custom design. Refer to drawings.
          ** NOTE TO SPECIFIER ** Delete grille type and design not required.
 
          K.Grille Type: Applied grille of laminated glass units with Queen Anne design.
 
          L.Grille Type: Applied grille of laminated glass units with Rectangular design.
 
          M.Grille Type: Applied grille of laminated glass units with custom design. Refer to drawings.
          ** NOTE TO SPECIFIER ** Contour and Flat available for grilles in airspace. Traditional, Regal and Super Regal available for applied grilles. Delete grille muntin profile not required.
 
          N.Grille Muntin Profile: Contour.
 
          O.Grille Muntin Profile: Flat.
 
          P.Grille Muntin Profile: Traditional.
 
          Q.Grille Muntin Profile: Regal.
 
          R.Grille Muntin Profile: Super Regal.
 
          2.4CONSTRUCTION
 
          A.Interior: Solid wood species. Finish as scheduled.
          ** NOTE TO SPECIFIER ** Delete species not required.
          1.Pine.
          2.Maple.
          3.Alder (clear).
          4.Mahogany.
          5.Cherry.
          6.Douglas Fir.
          7.Red Oak.
          8.Lyptus.
          9.White Oak.
          ** NOTE TO SPECIFIER ** Other species on request.
          10.Refer to Drawings
 
          B.Exterior Surface: Primed wood.
 
          C.Exterior Surface: Clear pine.
          ** NOTE TO SPECIFIER ** Additional Features: Extension jambs up to 7-3/8 inches (187 mm) and extruded aluminum drip cap. Delete if not required.
 
          D.Exterior Surface: Aluminum cladding; manufacturer's standard extruded-aluminum cladding, mechanically bonded to exterior exposed wood members. Provide aluminum alloy and temper recommended by manufacturer for strength, corrosion resistance, and application of required finish, but not less than 22,000 psi (150 MPa) ultimate tensile strength, and not less than 16,000 psi (110 MPa) minimum yield strength.
 
          E.Trim Profile:
          ** NOTE TO SPECIFIER ** Delete trim not required.
          1.Trim: Prairie.
          2.Trim: Tradesman
          3.Trim: Craftsman.
          4.Trim: Continental.
          5.Trim: Tradesman II.
          6.Trim: Colonial.
          7.Trim: Regal.
          8.Trim: Provincial.
          9.Trim: Tudor.
          10.Trim: Heritage.
          11.Trim: Heritage II.
          12.Trim: Traditional.
          13.Trim: Contemporary.
 
          F.Brick Mould or Casing: Aluminum exterior clad brick mould or casing.
          ** NOTE TO SPECIFIER ** Delete brick mould not required.
          1.Brick mould: 2 inches (51 mm).
          2.Ovolo: 2-1/2 inches (64 mm).
          3.Brick mould: 3-1/2 inches (89 mm). (Rectangle only).
          4.Flat Casing: 3-1/2 inches (89 mm). (Rectangle only).
 
          2.5FINISH
          ** NOTE TO SPECIFIER ** Delete interior finish not required.
 
          A.Interior Finish: Natural wood, species as selected.
 
          B.Interior Finish: Primed wood.
 
          C.Interior Finish: White factory finish.
          ** NOTE TO SPECIFIER ** Standard Cladding Finish. Delete if not required.
 
          D.Standard Cladding Finish: AAMA 2603.
          ** NOTE TO SPECIFIER ** Delete colors not required.
          1.Color: White.
          2.Color: Eggshell.
          3.Color: Sand.
          4.Color: Green.
          5.Color: Brick Red.
          6.Color: Bronze.
          7.Color: Jet Black.
          **NOTE TO SPECIFIER** Standard Optional Cladding Finish. Delete if not required.
 
          E.Standard Optional Cladding Finish: AAMA 2603.
          1.Color: Bone White.
          2.Color: Colonial White.
          3.Color: Burnt Sun.
          4.Color: Dijon.
          5.Color: Dried Wheat.
          6.Color: Sandstone.
          7.Color: Light Sea Wolf Beige.
          8.Color: Slate Gray.
          9.Color: Aspen Moss.
          10.Color: Sage Brown.
          11.Color: Natural Brown.
          12.Color: Desert Rose.
          13.Color: River Rouge Red.
          14.Color: Boysenberry.
          15.Color: Quaker Bronze.
          16.Color: Patina Green.
          17.Color: Legacy Blue.
          18.Color: Military Blue.
          19.Color: Yorktown.
          20.Color: Charcoal Gray.
          21.Color: Custom special color.
          ** NOTE TO SPECIFIER ** Optional Special Cladding Finish. Delete if not required.
 
          F.Optional Special Cladding Finish: AAMA 2605.
          ** NOTE TO SPECIFIER ** Delete colors not required.
          1.Color: White.
          2.Color: Eggshell.
          3.Color: Sand.
          4.Color: Green.
          5.Color: Brick Red.
          6.Color: Bronze.
          7.Color: Jet Black.
          8.Color: Bone White.
          9.Color: Colonial White.
          10.Color: Burnt Sun.
          11.Color: Dijon.
          12.Color: Dried Wheat.
          13.Color: Sandstone.
          14.Color: Light Sea Wolf Beige.
          15.Color: Slate Gray.
          16.Color: Aspen Moss.
          17.Color: Sage Brown.
          18.Color: Natural Brown.
          19.Color: Desert Rose.
          20.Color: River Rouge Red.
          21.Color: Boysenberry.
          22.Color: Quaker Bronze.
          23.Color: Patina Green.
          24.Color: Legacy Blue.
          25.Color: Military Blue.
          26.Color: Yorktown.
          27.Color: Charcoal Gray.
          28.Color: Silver (mica).
          29.Color: Champagne Bronze (mica).
          30.Color: Champagne Rose (mica).
          31.Color: Copper Wire (mica).
          32.Color: Gray Velvet (mica).
          33.Color: Custom special color.
          ** NOTE TO SPECIFIER ** Upgrade cladding finish. Delete if not required.
 
          G.Standard Anodized Finish: AAMA 611.
          ** NOTE TO SPECIFIER ** Delete colors not required.
          1.Color: Clear.
          2.Color: Champagne.
          3.Color: Light Bronze.
          4.Color: Medium Bronze.
          5.Color: Dark Bronze.
          ** NOTE TO SPECIFIER ** Upgrade cladding finish. Delete if not required.
 
          H.Optional Anodized Finish: AAMA 611.
          ** NOTE TO SPECIFIER ** Delete colors not required.
          1.Color: Extra Dark Bronze.
          2.Color: Black.
          3.Color: Copper.
 
          2.6HARDWARE
 
          A.Rollers: Fully adjustable tandem steel ball-bearing rollers.
 
          B.Locking Hardware: Elite C Handle
          1.Finish: Antique Brass.
          2.Finish: Bright Brass.
          3.Finish: Brushed Chrome.
          4.Finish: Polished Chrome.
          5.Finish: Oil Rubbed.
          ** NOTE TO SPECIFIER ** Standard for Clad French Sliding Patio Doors.
          6.Finish: White.
 
          C.Hinges:
          ** NOTE TO SPECIFIER ** Standard for Clad Outswing Patio Doors.
          1.Provide 5 knuckle butt hinge on outswing patio doors.
          ** NOTE TO SPECIFIER ** Delete locking hardware not required.
 
          D.Locking Hardware:
          1.Provide Hoppe five-point locking hardware.
          2.Provide flush bolt at head and sill of inactive leaf.
 
          E.Finish:
          ** NOTE TO SPECIFIER ** Delete finish not required. Gold Tone is standard finish, others are options.
          1.Finish: Antique Brass
          2.Finish: Bright Brass
          3.Finish: Brushed Chrome.
          4.Finish: Brushed Chrome.
          5.Finish: Polished Chrome
          6.Finish: Oil Rubbed.
          7.Finish: White.
 
          2.7FABRICATION
 
          A.Comply with WDMA I.S.6, "Industry Standard for Wood Stile and Rail Doors".
 
          B.Fabricate wood doors in sizes indicated.
 
          C.Fabricate wood doors that are reglazable.
 
          D.Weather Stripping: Provide full-perimeter weather stripping for each operable and or stationary panel, unless otherwise indicated.
 
          E.Factory machine doors for openings and for hardware that is not surface applied.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
 
          B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
 
          3.4PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
 
          C.Finished Doors: Replace doors that are damaged or do not comply with requirements. Doors may be repaired or refinished if work complies with requirements and shows no evidence of repair or refinishing.
 
         
END OF SECTION