| Find over 500 more construction specifications | Arcat.com |
![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||
This section is based on the products of Hurd Windows & Doors, Inc., which is located at: 575 S. Whelen Ave. Toll Free Tel: 800-2BE-HURD Medford, WI 54451 Tel: (715) 748-2011 Fax: (715)748-6043 Email: Hurdinfo1@2behurd.com Web: www.hurd.com The only thing we can never be sure of is the weather. We build our windows and doors to protect you from Mother Nature's whims. That's why we're proud to be an Energy Star Partner, dedicated to designing, building and promoting energy efficiency into our windows and doors. For more information about the Energy StarŪ rating and what it means, visit www.energystar.gov. So, that's all fine and well, but specifically, how good is a Hurd window? Well, the National Fenestration Rating Council has established testing criteria that determine window performance in three areas: thermal performance, solar heat gain and visible light transmittance. Now, when you want to find out how good a Hurd window is, all you have to do is check the NFRC label on them. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| PART 1 | GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | SECTION INCLUDES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Hurricane-resistant clad wood windows, glazing, hardware and trim. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | RELATED SECTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Section 01330 - Submittal Procedures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Section 01600 - Product Requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Section 06100 - Rough Carpentry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Section 06200 - Finish Carpentry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Section 07900 - Joint Sealers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Section 08810 - Glass and Glazing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Section 09900 - Painting: Interior painting of primed wood frame, door and trim. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | REFERENCES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | AAMA - American Architectural Manufactures Association: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | AAMA/NWWDA 101/I.S. 2-97 - Voluntary Standard for Aluminum and Poly Vinyl Chloride (PVC) Wood Windows and Glass Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | AAMA/WDMA/CSA 101./I.S.2/A440-05 - Standard/Specification for Windows, Doors and Unit Skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | AAMA 2604 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | ASTM - American Society for Testing and Materials: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | ASTM C1036 - Standard Specification for Flat Glass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | ASTM C1048 - Standard Specifications for Heat-Treated Glass - Kind HS, Kind FT Coated and Uncoated Glass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | ASTM E283 - Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Difference Across the Specimen. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | ASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | ASTM E547 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | ASTM E2188 - Standard Test Method for Insulating Glass Unit Performance. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | ASTM E2189 - Standard Test Method for Testing Resistance to Fogging in insulated Glass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | ASTM E 1886-02 --- Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | ASTM E 1996-02 --- Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | IGCC - Insulated Glass Certification Council. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | NFRC - National Fenestration Rating Council: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | NFRC -100 - Procedure for Determining Fenestration Product U - Factors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | NFRC - 200 - Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | NFRC - 500 - Procedure for Determining Fenestration Product Condensation Resistance Values. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | NWWDA - National Wood Window & Door Association: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | AAMA/NWWDA 101/I.S. 2-97 - Voluntary Standard for Aluminum and Poly Vinyl Chloride (PVC) Wood Windows and Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | SMA - Screen Manufacturers Association: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | SMA 1201- Specifications for Insect Screens for Windows, Sliding doors and Swinging Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | WDMA - Windows and Door Manufacturers Association: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | WDMA I.S.4 - Industry Standard for Water-Repellent Preservative Non -Pressure Treatment for Millwork. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | FBC TAS 201 - Impact Test Procedures; Florida Building Code; l994. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | FBC TAS 202 - Criteria for Testing Impact and Non Impact Resistant Building Envelope Components Using Uniform Static Air Pressure; Florida Building Code; 1994. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | FBC TAS 203 - Criteria for Testing Products Subject To Cyclic Wind Pressure Loading; Florida Building Code; 1994. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | DEFINITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Performance Class Designations: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | R (Residential): Commonly used in one and two-family dwellings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | LC (Light Commercial): Commonly used in low-rise multi dwellings, low rise professional offices, libraries and low-rise motels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | C (Commercial): Commonly used in lighter use industrial building and factories, hotels and retail sales buildings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | HC (Heavy Commercial): Commonly used in hospitals, schools, institutions, dormitories, government or public buildings, and other buildings where heavy use of fenestration products is expected. Also commonly used on mid-rise buildings with increased loading requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | AW (Architectural): Commonly used in hospitals, schools, institutions, and public buildings, or on high-rise and mid-rise buildings to meet increased loading requirements. Also commonly used in buildings where possible misuse of the fenestration products is expected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Performance Grade Designations: Actual design pressure that is designated by a number following the type and class designation in pounds force per square foot. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Minimum test size: The smallest size unit permitted for performance class (gateway test size). Products must be tested at the minimum test size or at a size larger than minimum test size to comply with requirements for performance class. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | PERFORMANCE REQUIREMENTS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Air infiltration (air leakage) shall not exceed the following when tested at 1.57 psf when tested in accordance with ASTM E283: 0.30 cfm per square foot of frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Water penetration resistance - There shall be no water penetration when tested at the desired/ specified pressure in accordance with ASTM E547. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Structural load testing - Product shall meet the damaged and permanent deflection pass/fail criteria as stated in AAMA/NWWDA 101/I.S. 2-97 or AAMA/WDMA/CSA 101 I.S.2/A440-05 when tested in accordance with ASTM E330. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | SUBMITTALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Shop Drawings: Submit under provisions of Section 01300. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Product Data: Submit manufacturer's catalog data on each product to be used in accordance with Section 01330. Include glazing system and two complete sets of color chips representing manufacturer's full range of available colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Samples: Submit corner section in accordance with Section 01330. Include glazing system and two complete sets of color chips representing manufacturer's full range of available colors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.7 | QUALITY ASSURANCE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Manufacturer Qualifications: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | A manufacturer capable of fabricating wood windows that meet or exceed performance requirements indicated and of documenting this performance by inclusion in lists and by labels, test reports, and calculations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Installer Qualifications: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | An installer acceptable to wood window manufacturer for installation of units required for this Project. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Product Requirements: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Comply with AAMA/WDMA 101/I.S.2/NAFS, "North American Fenestration Standard Voluntary Performance Specification for Windows, Skylights and Glass Doors" for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Comply with published recommendations of glass manufacturers and with GANA's "Glazing Manual" unless more stringent requirements are indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.8 | DELIVERY, STORAGE, AND HANDLING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Store products in manufacturer's unopened packaging in an upright position off the ground in a clean, dry area until ready for installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Prime or seal wood surfaces if more that 30 days between delivery and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.9 | PROJECT CONDITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Field Measurements: Verify wood window openings by field measurements before fabrication and indicate measurements on Shop Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.10 | WARRANTY | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Warranty Period: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Two Year Warranty: Glass Stress Cracks. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | See Hurd Windows and Doors, Inc. Product Warranty for details and exclusions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Ten Year Limited Life Time Warranty: Non-Glass Components. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | See Hurd Windows and Doors, Inc. Product Warranty for details and exclusions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Twenty Year Limited Life Time Warranty: Insulated Glass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | See Hurd Windows and Doors, 1nc. Product Warranty for details and exclusions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 2 | PRODUCTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | MANUFACTURERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer: Hurd Windows & Doors, Inc., which is located at: 575 S. Whelen Ave. ; Medford, WI 54451; Toll Free Tel: 800-2BE-HURD; Tel: 715-748-2011; Fax: 715-748-6043; Email: request info; Web: www.hurd.com | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Substitutions: Not permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Requests for substitutions will be considered in accordance with provisions of Section 01600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | APPLICATIONS/SCOPE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Refer to Window Schedule on the drawings for application and location. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Awning: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Energy Saver Awning Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 48-3/16 inches (1224 mm) by 36 -3/16 inches (919 mm). Single/Mulled units. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). Aluminum Clad Energy Saver Awning Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-70, maximum size 48-3/16 inches (1224 mm) by 36 3/16 inches (919 mm). Single/Mulled units. Glass Type A Monolithic 8.6mm (5/16 inches) Annealed Lami (3mm AN; 0.90 inches Saflex. PVB Interlayer; 3mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Corrosion-resistant dual arm operator of 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Encore folding handle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Concealed sliding nylon shoe hinges applied directly to sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Gear operator provides smooth operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Stainless steel hinge track for maximum support. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Guide bar operable system. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Sash locks: Two locks standard. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Weatherproofing: Perimeter weatherstrip on frame and sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Casement: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Energy Saver Casement Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 36 inches (914 mm) by 72 inches (1829 mm). Single/Mulled units up to 4-wide. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +55/-55 Wind Zone 4, Missile Level D, Operator / maximum size 36 inches (914 mm) by 72 inches (1829 mm) Picture / maximum size 60 inches (1524 mm) by 72 inches (1829 mm) Operator/fixed units in any combination up to 4-wide. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Energy Saver Casement Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70, maximum size 36 inches (914 mm) by 72 inches (1829 mm). Single/Mulled units up to 4-wide. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-85. maximum size 36 inches (914 mm) by 60 inches (1524 mm). Single/Mulled units up to 4-wide. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.75 inches Storm Interlayer, 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Performance: +65/-70. Operator / maximum size 36 inches (914 mm) by 72 inches (1829 mm) Picture / maximum size 60 inches (1524 mm) by 72 inches (1829 mm) Operator/fixed units in any combination up to 4-wide. Glass Type F Monolithic 14.04mm (9/16 inches) Annealed Lami ( 6mm AN; 0.090. PVB Interlayer, 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Corrosion-resistant dual arm operator of 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | DLX single lever multi lock system. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Concealed sliding nylon shoe hinges applied directly to sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Gear operator provides smooth operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Stainless steel hinge track for maximum support. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Weatherproofing: Perimeter weatherstrip on frame and sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Positive locking mechanism draws sash tight against weatherstrip. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Arch Head Casement: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Energy Saver Arch Head Casement Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 36 inches (914 mm) by 72 inches (1829 mm). Single/Mulled units. (This product NOT approved for Dade County.) Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Energy Saver Arch Head Casement Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +50/-50. maximum size 36 inches (914 mm) by 72 inches (1829 mm). Single/Mulled Units up to 4-Wide. (This product NOT approved for Dade County.) Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Jamb width 4-9/16 inches (116mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Corrosion-resistant dual arm operator of 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | DLX single lever multi lock system. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Concealed sliding nylon shoe hinges applied directly to sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Gear operator provides smooth operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Stainless steel hinge track for maximum support. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Roton hinges applied to Clad Arch Head Casements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Weatherproofing: Perimeter weatherstrip on frame and sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Positive locking mechanism draws sash tight against weatherstrip. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Optional extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Fixed Casement: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Energy Saver Fixed Casement Windows as manufactured by Hurd Windows and Doors, 1nc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +50/-50 Wind Zone 4, Missile Level D, maximum size 60 3/16 inches (1529 mm) by 72 3/16 inches (1834 mm). Single/Mulled units. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 54 3/16 inches (1376 mm) by 72 3/16 inches (1834 mm). Single/Mulled units. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 72 3/16 inches (1834 mm) by 60 3/16 inches (1529 mm). Single/ Mulled units. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance: +55/-55 Wind Zone 4, Missile Level D, maximum size 66 3/16 inches (1681 mm) by 66 3/16 inches (1681 mm). Single/Mulled units. Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Performance: +65/-70 Wind Zone 4, Missile Level D & Dade, maximum size 47 3/16 inches (1199 mm) by 91 3/16 inches (2316 mm). Single/Mulled units. Glass Type FF 1.049 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.6mm inches Heat Strength Lami (4mm HS; 0.090 inches Saflex PVB; 4mm HS Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Energy Fixed Casement Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-80. maximum size 65 3/16 inches (1656 mm) by 101 3/16 inches (2570 mm). Single Units Only. Glass Type G Monolithic 14.1mm (9/16 inches) Heat strengthened Lami (6mmHS; 0.075 Storm Interlayer; 6mm HS). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-70. maximum size 60 3/16 inches (1529 mm) by 72 3/16 inches (1834 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Performance: +61.8/-66.5. maximum size 60 3/16 inches (1529 mm) by 72 3/16 inches (1834 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance: +65/-70. maximum size 54 3/16 inches (1376 mm) by 72 3/16 inches (1834 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Performance: +65/-70. maximum size 72 3/16 inches (1834 mm) by 60 3/16 inches (1529 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Performance: +65/-70. maximum size 66 3/16 inches (1681 mm) by 66 3/16 inches (1681 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Performance: +65/-85. maximum size 48 3/16 inches (1224 mm) by 60 3/16 inches (1529 mm). Single Units Only. Glass Type E Monolithic 13.7mm (9/16 inches) Annealed Lami (6mm AN; 0.075 Strom Interlayer; 6mm AN) | |||||||||||||||||||||||||||||||||||||||||||||||||
| h. | Performance: +65/-70. maximum size 36 3/16 inches (919 mm) by 72 3/16 inches (1834 mm). Single Units Only. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Weatherproofing: Perimeter weatherstrip on frame and sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Optional extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Single Hung: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Single Hung Windows Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70 Wind Zone 4, Missile Level D, maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Single Hung Windows Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70. maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type A Monolithic 8.6mm (5/16 inches) Annealed Lami (3mm AN; 0.90 inches Saflex PVB Interlayer; 3mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Fixed top sash with a custodial side load re-movable bottom sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | No jamb liners. Exposed wood jamb. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Block and tackle balance mechanism. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Sweep Locks: Positive locking mechanism. (two locks standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Optional finger lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Weatherproofing: Weatherstrip located on bottom rails, head jamb, top check rail and top and bottom stiles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interlocking sash at meeting rail. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Single Hung Arched: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Single Hung Arched Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +60/-65 Wind Zone 4, Missile Level D, maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Single Hung Arched Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70. maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type A Monolithic 8.6mm (5/16 inches) Annealed Lami (3mm AN; 0.90 inches Saflex PVB Interlayer; 3mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Fixed top sash with a custodial side load re-movable bottom sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | No jamb liners. Exposed wood jamb. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Block and tackle balance mechanism. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Sweep Locks: Positive locking mechanism. (two locks standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Optional finger lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Weatherproofing: Weatherstrip located on bottom rails, head jamb, top check rail and top and bottom stiles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interlocking sash at meeting rail. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Single Hung Springline: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Single Hung Springline Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +50/65 Wind Zone 4, Missile Level D, maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type AA 15/16 inches Insul-3mm Temp Interior Lite; 0.438 Air Space; 8.6 Annealed Lami (3mm AN; 0.090 inches Saflex PVB; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Single Hung Springline Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +50/-65.maximum size 41 5/16 inches (1049 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type A Monolithic 8.6mm (5/16 inches) Annealed Lami (3mm AN; 0.90 inches Saflex PVB Interlayer; 3mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Fixed top sash with a custodial side load re-movable bottom sash. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | No jamb liners. Exposed wood jamb. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Block and tackle balance mechanism. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Sweep Locks: Positive locking mechanism. (two locks standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Optional finger lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Weatherproofing: Weatherstrip located on bottom rails, head jamb, top check rail and top and bottom stiles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interlocking sash at meeting rail. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Single Hung Picture: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Single Hung Picture Windows, Kingsview Series as manufactured by Hurd Windows and Doors, 1nc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70 Wind Zone 4, Missile Level D, maximum size 61 5/16 inches (1557 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type BB 1.023 inches Insul-6mm Temp Interior Lite; 0.438 inches Air Space; 8.3mm Annealed Lami (3mm AN; 0.075 inches Storm Interlayer; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Single Hung Picture Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70. maximum size 61 5/16 inches (1557 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type H-Monolithic 14.7mm (9/16 inches) Heat Strengthened Lami (6mm HS 100 HPJ Interlayer; 6mm HS) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Weatherproofing: Weatherstrip located on side jambs, top and bottom rails. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Interlocking sash at meeting rail. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Single Hung Sash'n Frame: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Single Hung Sash'n Frame Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70 Wind Zone 4, Missile Level D, maximum size 61 5/16 inches (1557 mm) by 76 5/8 inches (1946 mm). (This product NOT approved for Dade County.) Glass Type BB 1.023 inches Insul-6mm Temp Interior Lite; 0.438 inches Air Space; 8.3mm Annealed Lami (3mm AN; 0.075 inches Storm Interlayer; 3mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Single Hung Sash'n Frame Windows, Kingsview Series as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-70 maximum size 82 5/8 inches (2099 mm) by 29 5/16 inches (745 mm) (This product NOT approved for Dade County.) Glass Type A Monolithic 8.6mm (5/16 inches) Annealed Lami (3mm AN; 0.90 inches Saflex PVB Interlayer; 3mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Weatherproofing: Weatherstrip located on side jambs, top and bottom rails. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Rectangular shapes | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Angular shapes only available over awnings, casements and double hungs at this time. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Special Shapes: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Aluminum Clad Classic Direct Set / Circle Top Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance:+55/-55 Wind Zone 4, Missile Level D, maximum size 96 inches (2438 mm) by 48 inches (1219 mm). (This product NOT approved for Dade County.) Glass Type GG 1.08 inches Insul-6mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami (4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Aluminum Clad Classic Direct Set / Circle Top Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +80/-80. maximum size 96 inches (2438 mm) by 60 inches (1524 mm). Single Units Only Glass Type D-Monolithic 12.17mm (7/16 inches) Annealed Lami (5mm AN; 0.100 HPJ Interlayer; 5mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-70. maximum size 48 inches (1219 mm) by 72 3/16 inches (1834 mm). Mulled Units Up to 4-Wide. Glass Type H-Monolithic 14.7mm (9/16 inches) Heat Strengthened Lami (6mm HS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Aluminum Clad Energy Saver Direct Set / Circle Top Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Insulated Glass Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-85 Wind Zone 4, Missile Level D and Dade County, maximum size 61 13/16 inches (1570 mm) by 97 13/16 inches (2484 mm). Single Units Only. Glass Type HH-1.26 inches Insul-6mm Temp Interior Lite; 0.438 inches Air Space; 14.1mm Heat Strengthen Lami ( 6mm HS; 0.075 inches Storm Interior Layer; 6mm HS Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 31 13/16 inches (808 mm) by 85 13/16 inches (2180 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 33 13/16 inches (859 mm) by 77 13/16 inches (1976 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 37 13/16 inches (960 mm) by 71 13/16 inches (1824 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 41 13/16 inches (1062 mm) by 67 13/16 inches (1722 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 49 13/16 inches (1265 mm) by 60 13/16 inches (1545 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Performance: +65/-70 Wind Zone 4, Missile Level D and Dade County, maximum size 45 13/16 inches (1164 mm) by 63 13/16 inches (1621 mm). Single/Mulled Units Only. Glass Type CC-1.034 inches Insul-4mm Temp Interior Lite; 0.438 inches Air Space; 10.3mm Annealed Lami ( 4mm AN; 0.090 inches Saflex PVB; 4mm AN Ext. Lite). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Aluminum Clad Energy Saver Direct Set / Circle Top Windows as manufactured by Hurd Windows and Doors, Inc. FeelSafe Monolithic Impact Product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Performance: +65/-80. maximum size 61 13/16 inches (1570 mm) by 97 13/16 inches (2484 mm). Single Units Only. Glass Type G Monolithic 14.1mm (9/16 inches) Heat strengthened Lami (6mmHS; 0.075 Storm Interlayer; 6mm HS). | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Performance: +65/-70. maximum size 27 13/16 inches (706 mm) by 85 13/16 inches (2180 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Performance: +65/-70. maximum size 29 13/16 inches (757 mm) by 79 13/16 inches (2027 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance: +65/-70. maximum size 31 13/16 inches (808 mm) by 71 13/16 inches (1824 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Performance: +65/-70. maximum size 33 13/16 inches ( 859 mm) by 67 13/16 inches (1722 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Performance: +65/-70. maximum size 49 13/16 inches (1265 mm) by 51 13/16 inches (1316 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Performance: +65/-70. maximum size 45 13/16 inches (1164 mm) by 63 13/16 inches (1621 mm). Single/Mulled Units. Glass Type B Monolithic 10.3mm (3/8 inches) Annealed Lami (4mm AN; 0.90 inches Saflex PVB Interlayer; 4mm AN). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Jamb width 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Weatherproofing: Weatherstrip located on side jambs, top and bottom rails. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Rectangular shapes | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Angular Shapes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Extension Jambs: 4-3/4 inches (120 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Extension Jambs: 5 inches (127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Extension Jambs: 5-1/8 inches (130 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Extension Jambs: 5-5/16 inches (135 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Extension Jambs: 6-7/16 inches (138 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Extension Jambs: 6-9/16 inches (141 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Extension Jambs: 6-3/4 inches (171 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Extension Jambs: 7 inches (178 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Extension Jambs: 7-1/8 inches (181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Extension Jambs: 7-1/4 inches (184 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Extension Jambs: 7-3/8 inches (187 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Extension Jambs: Width as indicated on the Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Aluminum structural nailing fin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Pine interior casing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Pine rosettes. Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Oak interior casing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 26. | Oak rosettes. Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Insect Screen: Extruded-aluminum or formed-tubular-aluminum members, mesh fabric. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Frame Color: Match cladding color. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Frame Color: Gold Tone. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Frame Color: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Color: Bright Brass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Color: Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Frame Color: Brushed Chrome. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Frame Color: Oil Rubbed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Frame Color: Antique Brass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Frame Color: Polished Chrome. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Frame Color: Brushed Nickel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Frame Color: Champagne. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Frame Color: Coppertone. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Fiberglass charcoal colored mesh. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Aluminum mesh. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Screen Blinds: Combination screen and blind in one removable frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Blind Size: 1 inch (25 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Blind Size: 5/8 inch (16 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Frame Color: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Color: Pebble Tan. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Color: Spartan Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Blind Color: True White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Blind Color: Antique White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Blind Color: Fawn. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Blind Color: Greige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Blind Color: Off White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Blind Color: Silver. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Blind Color: Pewter. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Blind Color: Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Blind Color: Alabaster. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Blind Color: Sand. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Blind Color: Pebble Tan. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Blind Color: Granite. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Blind Color: Gray. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Blind Color: Pure Silver. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Blind Color: Dark Gray. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Blind Color: Umber. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | GLAZING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Factory-Glazed Fabrication: Comply with requirements of Section 08810 and with AAMA/WDMA 101/I.S.2/NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Safety Glass: Provide laminated and tempered products complying with testing requirements in 16 CFR 1201, for Category II materials. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Glass Type: Hurd FeelSafe Laminated Insulated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Color: Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Color: Gray. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Color: Green. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Color: Obscure - White Laminated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Glass Type: Hurd FeelSafe Laminated Low E Insulated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Color: Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Color: Gray. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Color: Green. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Glass Type: Hurd FeelSafe Laminated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Color: Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Color: Gray. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Color: Green. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Color: Obscure - White Laminated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Glass Type: Clear Climate Control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Glass Type: Clear Sun Blocker. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Glass Type: Clear Super Sun Blocker. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Glass Type: Clear ClimaGuard SPF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Grille Type: Interior removable wood with Queen Anne design. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Grille Type: Interior removable wood with Rectangular design. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Grille Type: Interior removable wood with custom design. Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Grille Type: Within airspace of insulated glass units with Queen Anne design. (Available only on Hurd FeelSafe Laminated Insulated Glass.) | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Grille Type: Within airspace of insulated glass units with Rectangular design. (Available only on Hurd FeelSafe Laminated Insulated Glass.) | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Grille Type: Within airspace of insulated glass units with custom design. Refer to drawings. (Available only on Hurd FeelSafe Laminated Insulated Glass.) | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Grille Type: Hurd Divided Lite (HDL) combination of applied wood interior grille, spacer within airspace of insulated glass units, with applied exterior grille, Queen Anne design. | |||||||||||||||||||||||||||||||||||||||||||||||||
| P. | Grille Type: Hurd Divided Lite (HDL) combination of applied wood interior grille, spacer within of insulated glass units, with applied exterior grille, Rectangular design. | |||||||||||||||||||||||||||||||||||||||||||||||||
| Q. | Grille Type: Hurd Divided Lite (HDL) combination of applied wood interior grille, spacer within airspace of insulated glass units, with applied exterior grille, Custom design. Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| R. | Grille Muntin Airspace Profile: Contour, 11/16 inch (17.5 mm) width. | |||||||||||||||||||||||||||||||||||||||||||||||||
| S. | Grille Muntin Airspace Profile: Contour, 1 inch (25.4 mm) width. | |||||||||||||||||||||||||||||||||||||||||||||||||
| T. | Grille Muntin Airspace Profile: Flat (rectangular). 5/8 inch (16mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| U. | Grille Muntin Profile: Traditional, 5/8 inch (16 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| V. | Grille Muntin Profile: Regal, 1 inch (25 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| W. | Grille Muntin Profile: Super Regal, 1-1/4 inches (32 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| X. | Grille HDL Muntin Profile: Traditional, 5/8 inch (16 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| Y. | Grille HDL Muntin Profile: Regal, 1 inch (25 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| Z. | Grille HDL Muntin Profile: Super Regal, 1-1/4 inches (32 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| AA. | Grille HDL Muntin Profile: Putty, 1 inch (25 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.4 | CONSTRUCTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Interior: Solid wood species. Finish as scheduled. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Pine. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Alder (clear). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Mahogany. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Douglas Fir. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Red Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Lyptus. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | White Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Other species on request. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Exterior Surface: Aluminum cladding; manufacturer's standard extruded-aluminum cladding, mechanically bonded to exterior exposed wood members. Provide aluminum alloy and temper recommended by manufacturer for strength, corrosion resistance, and application of required finish, but not less than 22,000 psi (150 MPa) ultimate tensile strength, and not less than 16,000 psi (110 MPa) minimum yield strength. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Profile: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Jamb Profile Width: 4-9/16 inches (116 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Trim: Prairie. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Trim: Tradesman | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Trim: Craftsman. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Trim: Continental. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Trim: Tradesman II. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Trim: Colonial. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Trim: Regal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Trim: Provincial. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Trim: Tudor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Trim: Heritage. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Trim: Heritage II. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Trim: Traditional. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Trim: Contemporary. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Extension Jambs: As indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Drip Cap: Extruded aluminum drip cap. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Brick Mould or Casing: Aluminum exterior clad brick mould or casing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Brick mould: 2 inches (51 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Ovolo: 2-1/2 inches (64 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Brick mould: 3-1/2 inches (89 mm). (Rectangle only). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Flat Casing: 3-1/2 inches (89 mm). (Rectangle only). | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Weatherproofing: Provide perimeter weatherstrip on operable and fixed panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.5 | FINISH | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Interior Finish: Natural wood, species as selected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Interior Finish: Primed wood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Interior Finish: White factory finish. | |||||||||||||||||||||||||||||||||||||||||||||||||