| Find over 500 more construction specifications | Arcat.com |
![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||
. This section is based on the products of companies which are part of ASSA ABLOY Door Security Solutions, which is located at: | ||||||||||||||||||||||||||||||||||||||||||||||||||
New Haven, CT 06511 Toll Free: (800) DSS-EZ4U Tel: (203) 624-5225 Fax: (203) 777-9042 Email: Web: http://www.assaabloydss.com. [ Click Here ] for additional information. | ||||||||||||||||||||||||||||||||||||||||||||||||||
Over and above product consultation and training, our sales and marketing experts bring you the resources of ASSA ABLOY, the world's largest company focusing solely on door security products. 13 Leading door and hardware brands, including Ceco Door, Corbin Russwin, Curries, Fleming, Folger Adam EDC, Graham, HES, McKinney, Norton, Rixson, Sargent, Securitron and Yale. Integrated life-safety and security solutions to meet end-users' most challenging problems. Nationwide network of local sales teams. Enhanced distributor support. Architectural education and specification consulting. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| PART 1 | GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | SECTION INCLUDES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Finish hardware and accessories for doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | RELATED SECTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Section 06100 - Rough Carpentry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Section 08110 - Steel doors and Frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Section 08120 - Aluminum Doors and Frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Section 08211 - Wood Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Division 16 - Electrical. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | GENERAL REQUIREMENTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Provide items, articles, materials, operations and methods listed, mentioned or scheduled herein or on drawings, in quantities as required to complete project. Provide hardware that functions properly. Prior to furnishing hardware, advise Architect of items that will not operate properly, are improper for conditions, or will not remain permanently anchored. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Include screws, special screws, bolts, special bolts, expansion shields, and other devices for proper application of hardware.. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | SUBMITTALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Hardware Schedule: Submit 5 copies of hardware schedule in vertical format as illustrated by the Sequence of Format for the Hardware Schedule as published by the Door and Hardware Institute. Schedules which do not comply will be returned for correction before checking. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Hardware schedule shall clearly indicate architect's hardware group and manufacturer of each item proposed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | The schedule shall be reviewed prior to submission by a certified Architectural Hardware Consultant (AHC), who shall affix their seal attesting to the completeness and correctness of the schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Provide 2 copies of illustrations from manufacturer's catalogs and data in brochure form. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Check specified hardware for suitability and adaptability to details and surrounding conditions. Indicate unsuitable or incompatible items and proposed substitutions in hardware schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide listing of manufacturer's template numbers for each item of hardware in hardware schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Furnish other Contractors and Subcontractors concerned with copies of final approved hardware schedule. Submit necessary templates and schedules as soon as possible to hollow metal, wood door, and aluminum door fabricators in accordance with schedule they require for fabrication. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Samples: Lever design or finish sample: Provide 3 samples if requested by architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Wiring Diagrams: Provide complete and detailed system operation and elevation diagrams specially developed for each opening requiring electrified hardware, except openings where only magnetic hold-opens or door position switches are specified. Provide these diagrams with hardware schedule submittal for approval. Provide detailed wiring diagrams with hardware delivery to jobsite. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Installation Instructions: Provide manufacturer's written installation and adjustment instructions for finish hardware. Send installation instructions to site with hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Contract Closeout Submittals: Comply with Section 01700 including specific requirements indicated below. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Operating and maintenance manuals: Submit 3 sets containing the following: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Catalog pages for each product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Name, address, and phone number of local representative for each manufacturer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Parts list for each product. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Copy of final approved hardware schedule, edited to reflect "As installed". | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Copy of final keying schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | As installed "Wiring Diagrams" for each opening connected to power, both low voltage and 110 volts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | One complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | QUALITY ASSURANCE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Manufacturer: Obtain each type of hardware (ie. latch and locksets, hinges, closers) from single manufacturer, although several may be indicated as offering products complying with requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Supplier: Recognized architectural finish hardware supplier, with warehousing facilities, who has been providing hardware for period of not less than 3 years. The supplier shall be, or employ, a certified Architectural Hardware Consultant (AHC), who is registered in the continuing education program as administered by the Door and Hardware Institute. The hardware schedule shall be prepared and signed by a certified AHC. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Installer: Firm with 3 years experience in installation of similar hardware to that required for this project, including specific requirements indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Regulatory Label Requirements: Provide nationally recognized testing agency label or stamp on hardware for labeled openings. Where UL requirements conflict with drawings or specifications, hardware conforming to UL requirements shall be provided. Conflicts and proposed substitutions shall be clearly indicated in hardware schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Handicapped Requirements: Doors to stairs (other than exit stairs), loading platforms, boiler rooms, stages and doors serving other hazardous locations shall have knurled or other similar approved marking of door lever handles or cross bars in accordance with local building codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Pre-Installation Conference: Prior to the installation of hardware, manufacturer's representatives for locksets, closers, and exit devices shall arrange and hold a jobsite meeting to instruct the installing contractor's personnel on the proper installation of their respective products. A letter of compliance, indicating when this meeting is held and who is in attendance, shall be sent to the Architect and Owner. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Finish areas designated by Architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Refinish mock-up area as required to produce acceptable work. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | DELIVERY, STORAGE AND HANDLING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Deliver hardware to jobsite in manufacturer's original packaging, marked to correspond with approved hardware schedule. Do not deliver hardware until suitable locked storage space is available. Check hardware against reviewed hardware schedule. Store hardware to protect against loss, theft or damage. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Deliver hardware required to be installed during fabrication of hollow metal, aluminum, wood, or stainless steel doors prepaid to manufacturer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.7 | PROJECT CONDITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.8 | WARRANTY | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Guarantee workmanship and material provided against defective manufacture. Repair or replace defective workmanship and material appearing within period of one year after Substantial Completion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide ten year factory warranty on door closer body against defects in material and workmanship from date of occupancy of Project. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Replace shortages and incorrect items with correct material at no additional cost to Owner. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | At completion of project, qualified factory representative shall inspect closer installations. After this inspection, letter shall be sent to Architect reporting on conditions, verifying that closers have been properly installed and adjusted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 2 | PRODUCTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | MANUFACTURERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers: Provide products manufactured by the companies listed with each type of hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Substitutions: Not permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Requests for substitutions will be considered in accordance with provisions of Section 01600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | BUTTS AND HINGES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Types: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Manufacturer: McKinney | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Type 1: T4A3795. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Type 2: TA2714. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Type 3: TA2314. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Type 4: T4A3786. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Type 5: T4A3386. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Application: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Exterior outswinging doors: Type 5 x NRP. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Exterior inswinging doors and vestibule doors: Type 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Interior doors with closers: Type 2 or 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Interior doors over 36 inches wide: Type 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Interior doors 36 inches or less without closer: Type 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Provide NRP (non-removable pins) at out-swinging lockable doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Size: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | 2-1/4 inch (57 mm) Doors: 5 inch by 5 inch (127 mm by 127 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | 1-3/4 inch (44 mm) Doors: 4-1/2 inch by 4-1/2 inch (114 mm by 114 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | 1-3/8 inch (35 mm) Doors: 3-1/2 inch by 3-1/2 inch (89 mm by 89 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Quantity: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | 2 - hinges per leaf for openings through 60 inches (1524 mm) high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | 1 - additional hinge per leaf for each additional 30 inches (762 mm) in height or fraction thereof. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | 4 - Dutch doors up to 90 inches (2289 mm) in height. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Drill 5/32 inch (4 mm) hole and use No. 12, 1-1/4 inch (32 mm) steel threaded to the head wood screws for hinges on wood doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | ELECTRIC HINGES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide electric hinges with standardized wire colors and concealed plug connectors to accommodate up to 12 wires. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Coordinate plug connectors so that they plug directly into wiring harnesses for connection to electric locking devices and power supplies. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide sufficient number of concealed wires to accommodate electric function of specified hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Locate electric hinges at second hinge from bottom. Where electric hinges are used in conjunction with exit devices, locate hinge nearest to exit device. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Provide mortar guard similar to McKinney MG-16 for each electric hinge scheduled. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.4 | CONTINUOUS GEARED HINGES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | MCK-12HD. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | MCK-25HD. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide one of the above two models of continuous hinges as appropriate for the type, inset, and thickness of door where specified. Coordinate hinge types with the door supplier. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.5 | STAINLESS STEEL CONTINUOUS HINGES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | MCK-FM300. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | MCK-HG305. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | MCK-HG310. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | MCK-HG311. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | MCK-HG315. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide one of the above models of continuous hinges as specified in Hardware Groups. Coordinate hinge types with the door supplier. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Where indicated in Hardware Groups, provide medical bearing (MB suffix) for continuous hinges. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.6 | FLOOR CLOSERS AND INTERMEDIATE PIVOTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rixson: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 27 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | M19. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Floor closers shall be complete with ball-bearing top pivot, floor plates, intermediate pivots and cement boxes unless indicated otherwise. One intermediate pivot for doors less than 91 inches (2311 mm) high. Two intermediate pivots for doors between 91 inches (2311 mm) and 121 inches (3073 mm) high. Intermediate pivots spaced equally not less than 25 inches (635 mm) or not more than 35 inches (889 mm) on center, for doors over 121 inches (3073 mm) high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide single-acting offset hung floor closers as specified in Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide floor closers with adjustable swing speed, latch speed, back-check, and automatic hold-open features. Closer shall have built in positive stop at specified degree of opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Floor closers shall meet maximum opening force requirements of ADA. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.7 | PIVOT SETS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Manufacturer: Rixson. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Offset, standard duty: 117. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Offset, heavy duty: 147. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Intermediate: M19. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Center, standard duty: 128-1/2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Center, heavy duty: 370. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Pivot sets shall be complete with oil-impregnated top pivot, unless indicated otherwise. For offset pivoted doors, provide one intermediate pivot for doors less than 91 inches (2311 mm) high. Two intermediate pivots for doors between 91 inches (2311 mm) and 121 inches (3073 mm) high. Intermediate pivots spaced equally not less than 25 inches (635 mm) or not more than 35 inches (889 mm) on center, for doors over 121 inches (3073 mm) high. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide pivot sets as specified in Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.8 | FLUSH BOLTS AND DUSTPROOF STRIKES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | FB01M. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | FB06M. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | FB10W. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | DPS1. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Non-labeled Openings: Provide 2 flush bolts FB01M for inactive leaf of pairs of locked and latched doors. Locate centerline of top bolt not more than 78 inches (1981 mm) from finished floor. Provide dustproof strike FB06M for bottom bolt. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Labeled Openings: Provide automatic flush bolt set FB06M or FB10W, as applicable, for inactive leaf of pairs of doors. Provide dustproof strike DPS1 for bottom bolt. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.9 | LOCKSETS - MORTISE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 8200 x LNL. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Yale: 8800FL x AUR. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Corbin/Russwin: ML2000 x NSA. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide lock functions specified in Hardware Groups, with following provisions: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Cylinders: Manufacturer's high security removable core 6-pin, meeting the requirements of UL437. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Locksets shall meet the requirements of ANSI/BHMA A156.13-1994, Operational Grade 1, and Security Grade 1. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Backsets: 2-3/4 inches (70 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Strikes: Provide wrought boxes and strikes with proper lip length to protect trim but not to project more than 1/8 inch (3 mm) beyond trim, frame or inactive leaf. Where required, provide open back strike and protected to allow practical and secure operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.10 | LOCKSETS - CYLINDRICAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 10-Line x LL. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Yale: 5400LN x AU. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Corbin/Russwin: CL3600 x NZD. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Cylinders: Manufacturer's high security removable core 6-pin, meeting the requirements of UL437. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Backsets: 2-3/4 inches (70 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Strikes: Provide wrought boxes and strikes with proper lip length to protect trim but not to project more than 1/8 inch (3 mm) beyond trim, frame or inactive leaf. Where required, provide open back strike and protected to allow practical and secure operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.11 | LOCKSETS - 11-LINE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer and Series (No Substitutions): | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 11-Line x LL. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Locksets shall be able to withstand 2400 inch pounds of torque applied to the locked lever without gaining access. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Locksets shall be cycle tested per ANSI A156.2, 1996, to two million cycles without any visible lever sag. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Locksets shall be able to fit a standard 2-1/8 inch (55 mm) bore without the use of thru-bolts. Standard rose size shall be 2-3/4 inches (70 mm) in diameter. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Lockset levers shall be made of solid material with no plastic fillers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Latchbolt head shall be one piece stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Latchbolt assemblies shall be encased within the lock body. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Cylinders: Sargent Signature Series, UL437 listed, high security 6-pin cylinders. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Backsets: 2-3/4 inches (70 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Strikes: Provide wrought boxes and strikes with proper lip length to protect trim but not to project more than 1/8 inch (3 mm) beyond trim, frame or inactive leaf. Where required, provide open back strike and protected to allow practical and secure operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Locksets shall have a seven year limited warranty. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.12 | ACCESS CONTROL MORTISE LOCKS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 8200. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide access control mortise lock series, type, and function where specified in hardware groups, with the provisions below. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Cylinders: Refer to keying requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Backsets: 2-3/4 inches (70 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Strikes: Provide wrought boxes and strikes with proper lip length to protect trim but not to project more than 1/8 inch (3 mm) beyond trim, frame or inactive leaf. Where required, provide open back strike and protected to allow practical and secure operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide access control products with non-volatile memory. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide keypad operated products with a minimum of 100 user codes (LK) or 500 user codes (LU). | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide keypad/proximity (PK) and proximity only (PA) products with a minimum of 500 user codes and the ability to audit the last 1,000 transactions via an RS-232 port. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | In addition to user codes, provide a Master Code as standard. The Master Code assigns emergency, supervisory, and user codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Lock shall have the ability to print the last fifteen entries (LK) via infrared printer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Provide SofLink Plus Software (LU, PK, PA) and computer cable kit (#52-2393), capable of working with Microsoft Windows operating systems (95 or higher), required to program time zone periods, holidays, automatic unlock with first entry, and listing 1,000 event transaction history - unlock, egress activation, entry into programming mode, date, time, user number, and door number. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Locking and unlocking of the lever handle shall be done by a motor-driven battery powered unit (solenoids not acceptable) contained completely within the body of the mortise lock. The inside lever is always free for egress. Provide lever design to match lockset levers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Provide regulated 9 VDC remote power package Model 3267. Power package to include Power Supply Module, Cable Assembly - Power Supply to Power Transfer, and Wall Plug in Transformer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | LED's on unit indicate status - unlocked and programming mode. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Provide weatherseal gasketing at exterior applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Provide twenty-five (25) HID Prox Card II for keypad/proximity (PK) and proximity only (PA) products. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Doors to stairs (other than exit stairs), loading platforms, boiler rooms, stages and doors serving other hazardous locations shall have knurled or other similar approved marking of door lever handles or cross bars in accordance with local building codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.13 | ACCESS CONTROL CYLINDRICAL LOCKSETS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 10-Line. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide cylindrical lock series and function where specified in hardware groups, with the provisions below. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Cylinders: Refer to keying requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Backsets: 2-3/4 inches (70 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Strikes: Provide wrought boxes and strikes with proper lip length to protect trim but not to project more than 1/8 inch (3 mm) beyond trim, frame or inactive leaf. Where required, provide open back strike and protected to allow practical and secure operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide access control products with non-volatile memory. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide keypad operated products with a minimum of 100 user codes (LK) or 500 user codes (LU). | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide keypad/proximity (PK) and proximity only (PA) products with a minimum of 500 user codes and the ability to audit the last 1,000 transactions via an RS-232 port. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | In addition to user codes, provide a Master Code as standard. The Master Code assigns emergency, supervisory, and user codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Provide the ability to print the last fifteen entries (LK) via infrared printer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Provide SofLink Plus Software (LU, PK, PA) and computer cable kit (#52-2393), capable of working with Microsoft Windows operating systems (95 or higher), required to program time zone periods, holidays, automatic unlock with first entry, and listing 1,000 event transaction history - unlock, egress activation, entry into programming mode, date, time, user number, and door number. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Locking and unlocking of the lever handle shall be done by a motor-driven battery powered unit (solenoids not acceptable) contained completely within the body of the cylindrical lock. The inside lever is always free for egress. Provide lever design to match lockset levers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Provide regulated 9 VDC remote power package Model 3267. Power package to include Power Supply Module, Cable Assembly - Power Supply to Power Transfer, and Wall Plug in Transformer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | LED's on unit indicate status - unlocked and programming mode. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Provide weatherseal gasketing at exterior applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Provide twenty-five (25) HID Prox Card II for keypad/proximity (PK) and proximity only (PA) products. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Doors to stairs (other than exit stairs), loading platforms, boiler rooms, stages and doors serving other hazardous locations shall have knurled or other similar approved marking of door lever handles or cross bars in accordance with local building codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.14 | SLIDING DOOR PRIVACY LOCKS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stanley: 101 PD, 150-62. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.15 | EMERGENCY DOOR STOP RELEASE AND STRIKE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: CSS-9. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide combination emergency stop and strike to allow door to swing open in opposite direction. Size for specific frame depth. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.16 | EXIT DEVICES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 80 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Yale: 7000 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Corbin-Russwin: ED5000 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide exit device series and functions as specified in Hardware Groups. Sargent product numbers are referenced in the Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | All exit devices shall be UL listed for panic. Exit devices for labeled doors shall be UL listed as "Fire Exit Hardware". | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Where lever trim is specified, provide lever design to match lockset levers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide cylinders for exit devices with locking trim and cylinder dogging. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Provide cylinder dogging feature for non-rated exit devices. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Provide keyed removable mullions, as specified in the Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.17 | ACCESS CONTROL EXIT DEVICES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 8800 Rim Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Sargent: 8900 Mortise Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide access control exit device series, type, and function where specified in hardware groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | All exit devices shall be UL listed for panic. Exit devices for labeled doors shall be UL listed as "Fire Exit Hardware". | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide exit devices factory cut to door width and height. Locate exit devices at a height recommended by the exit device manufacturer, allowable by governing building codes, and approved by the Architect. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide access control products with non-volatile memory. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Provide keypad operated products with a minimum of 100 user codes (LK) or 500 user codes (LU). | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Provide keypad/proximity (PK) and proximity only (PA) products with a minimum of 500 user codes and the ability to audit the last 1,000 transactions via an RS-232 port. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | In addition to user codes, provide a Master Code as standard. The Master Code assigns emergency, supervisory, and user codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Provide the ability to print the last fifteen entries (LK) via infrared printer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Provide SofLink Plus Software (LU, PK, PA) and computer cable kit (#52-2393), capable of working with Microsoft Windows operating systems (95 or higher), required to program time zone periods, holidays, automatic unlock with first entry, and listing 1,000 event transaction history - unlock, egress activation, entry into programming mode, date, time, user number, and door number. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Locking and unlocking of the lever handle shall be done by a motor-driven battery powered unit (solenoids not acceptable) contained completely within the body of the outside trim. Egress from the inside at all times. Provide lever design to match lockset levers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Provide regulated 9 VDC remote power package Model 3267. Power package to include Power Supply Module, Cable Assembly - Power Supply to Power Transfer, and Wall Plug in Transformer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | LED's on unit indicate status - unlocked and programming mode. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Provide weatherseal gasketing at exterior applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Provide twenty-five (25) HID Prox Card II for keypad/proximity (PK) and proximity only (PA) products. | |||||||||||||||||||||||||||||||||||||||||||||||||
| P. | Provide cylinder-dogging feature for non-rated exit devices. | |||||||||||||||||||||||||||||||||||||||||||||||||
| Q. | Provide keyed removable mullions, as specified in the Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| R. | Provide clear powder coating at exit devices used in full exterior application, highly corrosive areas, and where noted in the hardware groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| S. | Provide cylinders for exit devices with cylinder override and cylinder dogging. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.18 | HOSPITAL LATCHES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent; 115P. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide hospital latches as specified, with covers engraved "Push" and "Pull." | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide 5 inch backset for hospital latches, unless noted otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.19 | ELECTRIC STRIKES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | HES: 1006 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Folger-Adam: 310 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide electric strikes designed for use with the type locks shown at each opening where specified. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Electric Strikes shall be UL Listed as Burglary-Resistant Electric Door Strikes and where required shall be UL Listed as Electric Strikes for Fire Doors and Frames. Provide non fail-safe type electric strikes, unless specified otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide transformers and rectifiers for each strike as required. Verify voltage with electrical contractor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.20 | MAGNETIC LOCKS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Series: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Manufacturer: Sargent: Securitron: Folger Adam: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Series: 1584 62 9970LM. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Series: 1585 62(2) 9970LM (2). | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Magnetic locks shall meet ANSI/BHMA A156.23-1992 classification criteria including a minimum holding force of 1200 LBF. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Locks shall be equipped with a SPDT Magnetic Bond Sensing device to monitor whether sufficient magnetic holding force exists to ensure adequate locking. The bond sensor shall be fully concealed within the electromagnet to resist tampering or damage. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Magnetic Locks shall be equipped with a concealed adjustable time delay option to re-lock the door, adjustable from 1 to 90 seconds. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide power supplies for magnetic locks by the same manufacturer as locks. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.21 | KEYING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Master key or Grand master key cylinders and key in groups, unless otherwise specified. Factory masterkey with manufacturer retaining permanent keying records. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide 6 masterkeys for each masterkey set. Provide 3 change keys for each lock. Provide 2 control keys for core removal. Stamp keys "DO NOT DUPLICATE." | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Submit proposed keying schedule to Architect. If requested, meet with Owner and Architect to review schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide high security removable core cylinders, with patented key control, for each lock with construction masterkeying. Permanent cores shall be installed upon completion of the project. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Cylinders shall meet the requirements of UL437. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.22 | DOOR TRIM | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Push Plates: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney type P054 6 inches by 16 inch (152 mm by 406 mm) unless otherwise indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Where width of door stile prevents use of 6 inch (152 mm) wide plate, provide push plate one inch less than width of stile but not less than 4 inches (102 mm) wide. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Push Bars: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney type PB801, unless otherwise indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Pulls: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney Series OP9013, unless otherwise indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Where required, mount back to back with push bars. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Kick Plates and Armor Plates: Minimum of 0.050 inch (1.3 mm) thick, beveled 4 edges. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | At single doors provide width 1-1/2 inch (38 mm) less than door width on stop side and one inch less than door width on face side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | At pairs of doors provide width one inch (25 mm) less than door width on both sides. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Height of 10 inches (254 mm), unless otherwise indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Edge Guards: Minimum .050 inch (1.3 mm) thick, stainless steel, | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney type EG11 x 42 inches (1067 mm) high as noted in Hardware Groups. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.23 | COORDINATORS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Trimco: 3094. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide CSM Series coordinator for labeled pairs of doors equipped with automatic flush bolts and those with vertical rod/mortise lock fire exit device combinations with astragals. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide filler bars for total opening width, closer mounting brackets, carry bars, and special preparation for top latches where applicable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.24 | DOOR CLOSERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products for Exposed Closers: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 315/351-P10. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Norton: 7500/PR7500. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Yale: 4400/PR4400. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide non-sized closers, adjustable to meet maximum opening force requirements of ADA. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide drop plates, brackets, or adapters for arms as required to suit details. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Mount closers on room side of corridor doors, inside of exterior doors, and stair side of stairway doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide back-check for closers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Provide hold-open arms where indicated. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Provide closers for doors as noted in Hardware Groups and, in addition, provide closers for labeled doors whether or not specifically noted in group. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Provide closers meeting the requirements of UBC 7-2, 1997 and UL 10C positive pressure tests. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.25 | CLOSER/HOLDERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products for Exposed Closer/Holders: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 2468 and 2900. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Norton: 7700PT and 7210MPI. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Yale: 400PT and 4210MPI. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide non-sized closers, adjustable to meet maximum opening force requirements of ADA. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide drop plates, brackets, or adapters for arms as required to suit details. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Mount closers on room side of corridor doors, inside of exterior doors, and stair side of stairway doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide back-check for closers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Provide single-point or multi-point hold-open arms as specified. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Provide closer/holders meeting the requirements of UBC 7-2, 1997 and UL 10C positive pressure tests. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.26 | AUTOMATIC OPERATORS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 4000 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Norton: 6900 Series. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide automatic operators as specified in hardware groups. Provide complete with drop plates, brackets, or adapters for arms as required to suit details. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide wall-mounted actuator switches by the same manufacturer as the operator. Actuators shall be weather-resistant type at exterior applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.27 | BI-FOLDING DOOR HARDWARE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stanley: BF125. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Grant: 1260. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Lawrence: ED600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide complete hardware sets for each opening specified with bi-folding door hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Include track, hangers, fasteners, guides, and all hardware required for a complete installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.28 | SLIDING DOOR HARDWARE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stanley: Bi-Pass BP150. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Grant: 5150. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Lawrence: ED500. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide complete hardware sets for each opening specified with sliding door hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Include track, hangers, fasteners, guides, and all hardware required for a complete installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.29 | POCKET DOOR HARDWARE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stanley: PDF150. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide complete hardware sets for each opening specified with pocket door hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Include track, hangers, fasteners, guides, and all hardware required for a complete installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.30 | OVERHEAD STOPS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Manufacturer: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sargent: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Types: 1540, 1530, 590, 690. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Yale: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | 500V, 500, 900V, 100. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide 1540 Series overhead stops for doors equipped with regular arm surface type closer that swing more than 140 degrees before striking wall, and for doors that open against equipment, casework, sidelights, other objects that would make wall stops inappropriate. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide sex bolt attachments for mineral core door application. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.31 | WALL STOPS AND HOLDERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: Types WS01, DS20, DS22. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Provide WS01 Series wall stop as applicable, for each door leaf except where wall stops DS20 are specified in Hardware Groups, or where conditions require the use of an overhead stop. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide 1540 Series overhead stops for doors that swing more than 140 degrees before striking a wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Floor or base stops shall be used only where definitely specified or absolutely unavoidable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.32 | THRESHOLDS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney - MCK171A. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Where thresholds are specified in hardware groups, provide MCK171A thresholds unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Refer to drawings for special details. Provide accessories, shims and fasteners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Where thresholds occur at openings with one or more mullions, they shall be cut for the mullions and extended continuously for the entire opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.33 | WEATHERSTRIPPING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney: MCK315CN sweeps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | McKinney: MCK316AV jambs. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | McKinney: MCK348C door top drips. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Where weatherstripping is specified in hardware groups, provide MCK316AV unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide self-tapping fasteners for weatherstripping being applied to hollow metal frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Where sweeps are specified in hardware groups, provide MCK315CN unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Where rain drips are specified in hardware groups, provide MCK346C x full frame width, unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.34 | GASKETING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: McKinney, Pemko, and Reese Enterprises. Refer to drawings for special details. Provide accessories, shims and fasteners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney - MCKPK55D. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Where smoke gasket is specified in hardware groups, provide MCKPK55D, unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide gaskets for 20-minute doors and doors designated for smoke and draft control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Where frame applied intumescent seals are required by the manufacturer, provide gaskets that comply with UBC 7-2, 1997 and UL 10C positive pressure tests. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.35 | SOUND GASKETING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | McKinney Automatic Door Bottoms: MCK4301CRL. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | McKinney Jambs: MCK379CR. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Where gasketing is specified in hardware groups, provide MCK4301CRL and MCK379CR unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Provide self-tapping fasteners being applied to hollow metal doors and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Cutting or notching of sound gasket for stop mounted hardware shall not be permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.36 | MAGNETIC HOLDERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 1561. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rixson-Firemark: FM-998. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | HES: 8837. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Where magnetic holders are specified in the Hardware Groups, provide Rixson FM-998, LCN SEM 850, or Sargent 1561 unless detailed otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Verify voltage with Electrical Contractor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.37 | DOOR POSITION SWITCHES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Sargent: 3287. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Coordinate door and frame preparations with door and frame suppliers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Switches shall be installed in frame head approximately 4 inches (102 mm) from latching door edge. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.38 | LATCH PROTECTORS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturers and Products: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | M.A.G.: 8851-S. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rockwood: 320-32D. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Don-Jo: CLP-110-32D. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Latch protectors shall be stainless steel of the type required to work with the specified latch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.39 | KEY CABINET | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Provide key cabinets by Lund Equipment, Telkee Incorporated, or Key Control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Lund Deluxe wall type cabinet, Series 1200. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide cabinet with one hook for each lock or cylinder plus at least 50 percent extra hooks. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Provide each hook with one non-removable security key tag and one snap-on link duplicate key tag. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Provide tools, instruction sheets and accessories required to complete installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Owner will place keys in key cabinet and complete index cards furnished with key system. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.40 | KEY MANAGEMENT SOFTWARE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Provide Key Wizard key management software. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Software shall provide tracking, issuing, collecting and transferring information regarding keys, doors, and hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide training for Owner's personnel on the proper operation and application of the key management software. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.41 | FASTENERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Including, but not limited to, wood or machine screws, bolts, bolts, nuts, anchors, etc. of proper type, material, and finish required for installation of hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Use phillips head for exposed screws. Do not use aluminum screws to attach hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide self-tapping (TEC) screws for attachment of sweeps and stop-applied weatherstripping only. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.42 | TYPICAL FINISHES AND MATERIALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Finishes, unless otherwise specified: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Butts: Outswinging Exterior Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US32D (BHMA 630) on Stainless Steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Butts: Interior Doors and Inswinging Exterior Doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US26D (BHMA 652) on Steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Continuous Hinges: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US28 (BHMA 628) on Aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Flush Bolts: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US26D (BHMA 626) on Brass or Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Exit Devices: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US32D (BHMA 630) on Stainless Steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Locks and Latches: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US26D (BHMA 626) on Brass or Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Push Plates, Pulls and Push Bars: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US32D (BHMA 630) on Stainless Steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Coordinators: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | USP (BHMA 600) on Steel | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Kick Plates, Armor Plates, and Edge Guards: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US32D (BHMA 630) on Stainless Steel | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Overhead Stops and Holders: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US26D (BHMA 626) on Brass or Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Closers: Surface mounted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Sprayed Aluminum Lacquer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Latch Protectors: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US32D (BHMA 630) on Stainless Steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Miscellaneous Hardware: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | US26D (BHMA 626) on Brass or Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | All locksets and exit devices shall be finished with SARGuard by Sargent, an FDA recognized antimicrobial coating with built in protection to prevent the growth of a broad range of bacteria, mold, and mildew. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 3 | EXECUTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.1 | EXAMINATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Examine doors, frames, and related items for conditions that would prevent the proper application of finish hardware. Do not proceed until defects are corrected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.2 | INSTALLATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Install finish hardware in accordance with reviewed hardware schedule and manufacturer's printed instructions. Prefit hardware before finish is applied, remove and reinstall after finish is completed. Install hardware so that parts operate smoothly, close tightly and do not rattle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Installation of hardware shall comply with NFPA 80 and NFPA 101 requirements. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Set units level, plumb and true to line and location. Adjust and reinforce attachment to substrate as necessary for proper installation and operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Drill and countersink units which are not factory-prepared for anchorage fasteners. Space fasteners and anchors in accordance with industry standards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Set thresholds for exterior doors in full bed of butyl-rubber or polyisobutylene mastic sealant, forming tight seal between threshold and surface to which set. Securely and permanently anchor thresholds, using countersunk non-ferrous screws to match color of thresholds (stainless steel screws at aluminum thresholds). | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Lead Protection: Lead wrap hardware penetrating lead-lined doors. Levers and roses to be lead lined. Apply kick and armor plates with 3M adhesive #1357, as recommended by 3M Co., on lead-lined doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.3 | FIELD QUALITY CONTROL | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | After installation has been completed, provide services of qualified hardware consultant to check Project to determine proper application of finish hardware according to schedule. Also check operation and adjustment of hardware items. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Adjust door control devices to compensate for final operation of heating and ventilating equipment. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.4 | ADJUSTING AND CLEANING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | At final completion, hardware shall be left clean and free from disfigurement. Make final adjustment to door closers and other items of hardware. Where hardware is found defective repair or replace or otherwise correct as directed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Adjust door closers to meet opening force requirements of Uniform Federal Accessibility Standards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Final Adjustment: Wherever hardware installation is made more than one month prior to acceptance or occupancy of space or area, return to work during week prior to acceptance or occupancy, and make final check and adjustment of hardware items in such space or area. Clean operating items as necessary to restore proper function and finish of hardware and doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Instruct Owner's personnel in proper adjustment and maintenance of door hardware and hardware finishes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Clean adjacent surfaces soiled by hardware installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.5 | PROTECTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Provide for proper protection of items of hardware until Owner accepts Project as complete. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.6 | HARDWARE GROUPS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | The following schedule of hardware groups shall be considered a guide only, and the supplier is cautioned to refer to general conditions, special conditions, and the preamble to this section. It shall be the hardware supplier's responsibility to furnish all required hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Refer to the door schedule for hardware group required at each door opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.7 | HARDWARE GROUPS | |||||||||||||||||||||||||||||||||||||||||||||||||