MasterFormat: 95
SpecWizard: customize this spec    Download this Door Hardware Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
DORMA  Architectural Hardware Door Hardware
 
         
SECTION 08710
 
         
DOOR HARDWARE
 
         
Copyright 2007 - 2012 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** DORMA Architectural Hardware; Architectural door hardware products.
.
This section is based on the products of DORMA Architectural Hardware, which is located at:
Dorma Dr. Drawer AC
Reamstown, PA 17567-0411
Toll Free Tel: 800-523-8483
Tel: 717-336-3881
Email: request info
Web: www.dorma-usa.com
[ Click Here ] for additional information.

Built on a tradition of innovation and responsiveness, DORMA Architectural Hardware markets a wide range of state-of-the-art and aesthetically-pleasing door controls, exit devices, locks and electronic control hardware. Manufactured in the company's ISO 9001** certified facilities in Reamstown, Pennsylvania and Steeleville, Illinois, DORMA Architectural Hardware is delivering the next generation of door system technology, including surface closers, concealed closers, locks and key systems, exit devices, low energy operators, coordinator/closer systems, fire/life safety, overhead stops/holders, electronic access control and pivots.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Hinges and Pivots.
 
          B.Mortise Locksets and Deadbolts.
 
          C.Cylindrical Locksets and Deadbolts.
 
          D.Dead Bolts.
 
          E.Cylinders.
 
          F.Keying.
 
          G.Exit Devices.
 
          H.Surface Door Closers.
 
          I.Concealed Door Closers.
 
          J.Low Energy Operators.
 
          K.Fire/Life Safety Devices.
 
          L.Miscellaneous Trim.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 05100 - Structural Metal Framing: Door Frames.
 
          B.Section 06100 - Rough Carpentry: Door Frames.
 
          C.Section 07840 - Fire Seals: Fire rated gaskets at perimeter of doors.
 
          D.Section 08100 - Metal Doors and Frames.
 
          E.Section 08200 - Wood and Plastic Doors.
 
          F.Section 08410 - Aluminum Entrance Systems, except cylinders.
 
          G.Section 08720 - Weatherstripping: Weatherstripping and thresholds.
 
          H.Section 13710 - Intrusion Detection: Security system.
 
          I.Section 13720 - Security Access: Card access system.
 
          J.Section 16100 - Wiring Methods: Electric lock control wiring.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ANSI A117.1 - American National Standard for Accessible and Useable Buildings and Facilities.
 
          B.ANSI/BHMA A156.1, "Butts and Hinges" (copyrighted by BHMA, ANSI approved).
 
          C.ANSI/BHMA A156.2 - American National Standard for Bored and Preassembled Locks & Latches.
 
          D.ANSI/BHMA A156.3 - American National Standard for Exit Devices.
 
          E.ANSI/BHMA A156.4 - American National Standard for Door Controls - Closers.
 
          F.ANSI/BHMA A156.5 - American National Standard for Auxiliary Locks and Associated Products.
 
          G.ANSI/BHMA A156.6, "Architectural Door Trim" (copyrighted by BHMA, ANSI approved).
 
          H.ANSI/BHMA A156.7, "Template Hinge Dimensions" (copyrighted by BHMA, ANSI approved).
 
          I.ANSI/BHMA A156.8, "Door Controls - Overhead Holders" (copyrighted by BHMA, ANSI approved).
 
          J.ANSI/BHMA A156.13 - American National Standard for Mortise Locks and Latches Series 1000.
 
          K.ANSI/BHMA A156.15 - Life Safety Closer/Holder/Release Devices.
 
          L.ANSI/BHMA A156.16 - Auxiliary Hardware.
 
          M.ANSI/BHMA A156.18 - Materials and Finishes.
 
          N.ANSI A156.19 - American National Standard for Power Assist and Low Energy Power Operated Doors.
 
          O.ANSI A156.23 - American National Standard for Electromagnetic Locks
 
          P.ANSI A156.24 - American National Standard for Delayed Egress Locks
 
          Q.ANSI A156.25 - American National Standard for Electrified Locking Devices
 
          R.ANSI A156.28 - American National Standard for Keying Systems
 
          S.ANSI A156.29 - American National Standard for Exit Locks and Alarms, Exit Locks with Exit Alarms and Alarms for Exit Devices
 
          T.ANSI A156.31 - American National Standard for Electric Strikes and Frame Mounted Actuators
 
          U.NFPA 80 - Standard for Fire Doors, Fire Windows.
 
          V.NFPA 252 - Standard Methods of Fire Tests of Door Assemblies.
 
          W.Underwriters Laboratories (UL). - Fire Resistance Directory.
 
          X.ANSI/UL 10C - Standard for Safety for Positive Pressure Fire Tests of Door Assemblies.
 
          1.4PERFORMANCE REQUIREMENTS
          ** NOTE TO SPECIFIER ** Delete any references below not relevant to this project; add others as required.
 
          A.Fire Rated Openings: Provide door hardware listed by UL or Intertek Testing Services (Warnock Hersey Listed), or other testing laboratory approved by applicable authorities.
          1.Comply with NFPA 80 for fire ratings indicated, based on testing according to NFPA 252.
          2.Comply with UL10C, Positive Pressure Fire Tests of Door Assemblies.
 
          B.Accessibility Requirements: Comply with requirements of Local building code, and Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities.
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.Product Data: Manufacturer's catalog cuts on each product to be used.
 
          C.Shop Drawings: Indicate locations and mounting heights of each type of hardware, schedules, electrical characteristics and connection requirements.
 
          D.Schedule:
          1.Submit schedule indicating each type of hardware for each door.
          2.List manufacturer's name with each manufacturer's hardware number together with finishes in US standards.
          3.Show door number/location, handing, door and frame material, manufacture and catalog numbers, all finishes and keying information. Explain fully all abbreviations.
 
          E.Shop Drawings:
          1.Indicate locations and mounting heights of each type of hardware.
          2.Supply templates to door and frame manufacturer(s) to enable proper and accurate sizing and locations of cut-outs for hardware.
          3.Detail any conditions requiring custom extended lip strikes, or any other special or custom conditions.
          ** NOTE TO SPECIFIER ** Include the following paragraph only where required for electrical devices specified. Delete if not required.
          4.Wiring diagrams including point to point and riser diagrams, function statements and system descriptions for all electrical hardware
 
          F.Verification Samples: For each finish product specified.
          1.If required by the Architect, submit one sample of each type of typical hardware required illustrating style, color, and finish.
          2.Approved samples may be incorporated into Work.
 
          G.Closeout Submittals:
          1.Project Record Documents: Schedule showing actual locations of installed cylinders and their master key code.
          2.Parts lists and maintenance instructions including data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.
          3.Keys: Deliver with identifying tags to Owner by security shipment direct from hardware supplier.
 
          1.6QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: A manufacturer with a minimum of ten years experience manufacturing door hardware.
 
          B.Supplier Qualifications: A supplier with a minimum of two years demonstrated experience in the sale and distribution of builders' hardware for commercial projects and who has successfully completed at least three projects of similar complexity to the project specified.
 
          C.Hardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services required for the project.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Package hardware items individually with necessary fasteners and installation templates when necessary; label and identify each package with door opening code to match hardware schedule.
 
          B.Store products in manufacturer's unopened packaging until ready for installation.
 
          C.Protect materials from exposure to moisture. Do not deliver until after wet work is complete and dry.
 
          D.Store materials in a dry, warm, ventilated weathertight location.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          1.9WARRANTY
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.Provide factory warranty against defects in material and workmanship as follows:
          1.Overhead Surface Closers, Grade 1, 25 Year Warranty.
          2.Overhead Concealed closers 10 Year Warranty.
          3.Floor Closers 25 Year Warranty.
          4.Mortise locks, Grade 1, 10 Year Warranty.
          5.Cylindrical locks, Grade 1, 10 Year Warranty.
          6.Cylindrical locks, Grade 2, 5 Year Warranty.
          7.Standard and Interchangeable Cylinders, 2 Year Warranty.
          8.Patented Key Control SKC Cylinders, Lifetime Warranty.
          9.Electrical components 2 Year Warranty.
 
          1.10MAINTENANCE MATERIALS
 
          A.Provide special wrenches and tools applicable to each different or special hardware component.
 
          1.11COORDINATION
 
          A.Coordinate work with other directly affected components involving manufacture or fabrication of internal reinforcement for door hardware and recessed items.
          ** NOTE TO SPECIFIER ** Include the following paragraph only where required for electrical devices specified. Delete if not required.
 
          B.Coordinate work with other directly affected components involving electrical wiring and components.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: DORMA Architectural Hardware, which is located at: Dorma Dr. Drawer AC ; Reamstown, PA 17567-0411; Toll Free Tel: 800-523-8483; Tel: 717-336-3881; Email: request info; Web: www.dorma-usa.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
          ** NOTE TO SPECIFIER ** Select hinges and pivots required from the following paragraphs and delete those not required. Identify detail options on the Hardware Schedule. Coordinate with DORMA website for current literature for Pivot descriptions.
 
          2.2HINGES AND PIVOTS
 
          A.Hinges: ANSI A156.1, full mortise template type complying with following general requirements unless otherwise scheduled.
          1.Widths: Sufficient to clear trim projection when door swings 180 degrees.
          2.Number: Furnish minimum three hinges to 90 inches (2 286 mm) high, four hinges to 120 inches (3 048 mm) high for each door leaf.
          a.Fire Rated Doors To 86 inches (2 184 mm) High: Minimum three ball bearing hinges.
          b.Residential Wood Doors: Furnish minimum two hinges.
          3.Size and Weight: 4-1/2 inch (114 mm) heavy weight typical for 1-3/4 inch (44 mm) doors.
          a.Doors Over 40 inches (1 016 mm) Wide: Extra heavy weight ball or oilite bearing hinges.
          b.Doors 1-3/8 inch (35 mm) Thick: 3-1/2 inch (89 mm) size.
          c.Doors 2 inch (50 mm) Thick: 5 inch (125 mm) extra heavy weight ball or oilite bearing.
          d.Doors Over 48 inches (1 220 mm) Wide: 5 inch (125 mm) extra heavy weight ball or oilite bearing.
          4.Pins: Furnish nonferrous hinges with non-removable pins (NRP) at exterior and locked outswinging doors, non-rising pins at interior doors.
          5.Tips: Furnish with matching plug.
          ** NOTE TO SPECIFIER ** Select Hinge material(s) from the following paragraphs and delete those not required.
          6.Material: Steel - Polished and plated.
          7.Material: Steel - Bonderized and prime coated to receive paint.
          8.Material: Brass - Polished and plated.
          9.Material: Stainless Steel - Polished and satin finished.
 
          B.LM Series Pivots: ANSI A156.4, center and offset pivots
          1.CO7032 Center Pivoted, 440 lb Door Maximum. DORMA LM Series CP440, CPA440.
          2.CO7131 Offset Pivoted, Side Jamb Bottom Pivot, 350 lb Door Maximum. DORMA LM Series OPJ350.
          3.CO7162 Offset Pivoted, 440/200 lb Door Maximum. DORMA LM Series OP440.
          4.CO7172 Offset Pivoted, Side Jamb Bottom Pivot, 350 lb Door Maximum. DORMA LM Series OPJ350.
          5.CO7202 Offset Pivoted, Labeled Fire Doors, 350 lb Door Maximum. DORMA LM Series OPF440.
          6.CO7321 Offset Pivoted, Intermediate Pivot DORMA LM Series 75220, 15220.
          7.CO7321 Offset Pivoted, Intermediate Pivot, 20 minute Labeled Fire Doors DORMA LM Series 75222.
          8.CO7371 Offset Pivoted, Intermediate Pivot, Labeled Fire Doors DORMA LM Series 75233.
          9.C07601 Pocket Pivoted, DORMA LM Series 75520 bronze pocket pivot for 90 degree pocket doors.
          10.C07611 Pocket Pivoted, DORMA LM Series 75523 steel pocket pivot for 90 degree pocket doors, UL listed for 20 minute wood fire doors and 3 hour rated steel fire doors.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          11.Finish: As specified in the Door Hardware Schedule.
          12.Standard Sprayed Finish: As selected by the Architect.
          13.Custom Paint Finish: Optional Special color as selected by the Architect.
          14.Finish: 689 (Aluminum).
          15.Finish: 690 (Dark Bronze).
          16.Finish: 691 (Light Bronze).
          17.Finish: 693 (Black).
          18.Finish: 695 (Dark Duronodic Bronze).
          19.Finish: 696 (Gold).
          20.Finish: 600 Primer.
          21.Plated Finish: Brass: 605 (Bright).
          22.Plated Finish: Brass: 606 (Satin).
          23.Plated Finish: Bronze: 611 (Bright).
          24.Plated Finish: Bronze: 612 (Satin).
          25.Plated Finish: Bronze: 613 (Dark).
          26.Plated Finish: Nickel: 618 (Bright).
          27.Plated Finish: Nickel: 619 (Satin).
          28.Plated Finish: Chrome: 625 (Bright).
          29.Plated Finish: Chrome: 626 (Satin).
 
          2.3MORTISE LOCKSETS AND DEADBOLTS
 
          A.Lockset: DORMA ML9000 Series.
          1.Standards:
          a.ANSI Conformance - ANSI A156.13, Operational Grade 1, Security Grade 1.
          ** NOTE TO SPECIFIER ** Listed for A label and lesser class doors, 4 feet by 8 feet maximum per leaf. Locks also listed for 1-1/2 hour rated or lesser doors, 4 feet by 9 feet maximum per leaf.
          b.U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive pressure applications.
          c.U.L. and C.U.L. listed for UL 10B/10C.
          d.Lever trim meets A117.1 and ADA requirements.
          2.Features:
          a.Stainless steel latch.
          b.Stainless steel dead bolt.
          c.Hardened steel rollers in dead bolt.
          d.Security spacer between inside and outside lever.
          e.Steel lock case and internal components.
          f.Full length face plate.
          g.All trim through-bolted through the lock case.
          h.Accepts standard and interchangeable core cylinders.
          3.Function:
          ** NOTE TO SPECIFIER ** Select Lockset Function(s) and identify on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions. Delete one of the next two paragraphs and include lockset functions on hardware schedule as required.
          a.As noted on the hardware schedule attached to this section.
          b.As noted on the hardware schedule on the Drawings.
          c.ML9010 - F01 Passage Set
          d.ML9040 - F22 Privacy Lock
          e.ML9050 - F04 Single Cylinder Office Lock
          f.ML9060 - F09 Double Cylinder Entrance or Stairwell Lock
          g.ML9070 - F05 Single Cylinder Classroom Lock
          h.ML9080 - F07 Single Cylinder Storeroom Lock
          i.ML9001 - Single Dummy Trim
          j.ML9953 - F20 Single Cylinder Deadbolt Entrance Lock
          k.MB9960 - F17 Dead Bolt Cylinder by Turn Piece
          l.MB9962 - F16 Dead Bolt Cylinder both sides.
          4.Trim:
          ** NOTE TO SPECIFIER ** Select Lever and trim option(s) as required for the project and delete those not required.
          a.Lever: LRA, 2-1/4 inch (57 mm) rose.
          b.Lever: LRB, 2-9/16 inch (65 mm) rose.
          c.Lever: LRH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.
          d.Lever: LRM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.
          e.Lever: LCA, 2-1/4 inch (57 mm) rose.
          f.Lever: LCB, 2-9/16 inch (65 mm) rose.
          g.Lever: LCH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.
          h.Lever: LCM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.
          i.Lever: LTA, 2-1/4 inch (57 mm) rose.
          j.Lever: LTB, 2-9/16 inch (65 mm) rose.
          k.Lever: LTH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.
          l.Lever: LTM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.
          m.Lever: LGA, 2-1/4 inch (57 mm) rose.
          n.Lever: LGB, 2-9/16 inch (65 mm) rose.
          o.Lever: LGH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.
          p.Lever: LGM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.
          5.Lock Cylinder:
          ** NOTE TO SPECIFIER ** Select cylinder as required for the project and delete the one not required.
          a.DORMA standard keyway with two nickel silver keys.
          b.Interchangeable Core.
          c.Patented SKC key system.
          6.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Brass: 605 (Bright).
          c.Brass: 606 (Satin).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Chrome: 626 (Satin).
          g.Stainless: 630 (Satin).
 
          2.4CYLINDRICAL LOCKSETS AND DEADBOLTS
 
          A.Lockset: DORMA CL800 Series, Heavy Duty.
          1.Standards:
          a.ANSI Conformance - ANSI A156.2, Series 4000, Grade 1.
          ** NOTE TO SPECIFIER ** Locksets with 1/2 inch (12.5 mm) throw latch bolts are listed for A label and lesser class single doors, 4 feet by 10 feet maximum. Locks with 3/4 inch (19 mm) throw latch bolts are listed for A label and lesser class double doors, 4 feet by 10 feet per leaf maximum.
          b.U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive pressure applications.
          c.U.L. and C.U.L. listed for UL 10B/10C.
          d.Lever trim meets ANSI A117.1 and ADA requirements.
          2.Features:
          a.Stainless steel latch.
          b.Auxiliary deadlocking latch bolt.
          c.Cast stainless steel latch retractor with bronze bearings.
          d.Lock chassis constructed of steel and stainless steel components.
          e.Key-in-lever lock through-bolted.
          3.Function:
          ** NOTE TO SPECIFIER ** Select Lockset Function(s) and identify on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions. Delete one of the next two paragraphs and include lockset functions on hardware schedule as required.
          a.As noted on the hardware schedule attached to this section.
          b.As noted on the hardware schedule on the Drawings.
          c.CL810 - F75 Passage Set
          d.CL840 - F76A Privacy Lock
          e.CL853 - F109 Entrance/Office Lock
          f.CL860 - F88 Double Cylinder Vestibule Lock
          g.CL870 - F84 Classroom Lock
          h.CL801 (BE) - Single Dummy Trim.
          4.Trim:
          ** NOTE TO SPECIFIER ** Select Lever and trim option(s) as required for the project and delete those not required.
          a.Lever: LR, 3-7/16 inch (87 mm) rose.
          b.Lever: LC, 3-7/16 inch (87 mm) rose.
          c.Lever: LG, 3-7/16 inch (87 mm) rose.
          5.Lock Cylinder:
          ** NOTE TO SPECIFIER ** Select cylinder as required for the project and delete the one not required.
          a.DORMA standard keyway with two nickel silver keys.
          b.Interchangeable core.
          c.Patented SKC key system.
          6.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Brass: 605 (Bright).
          c.Brass: 606 (Satin).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Chrome: 626 (Satin).
          g.Chrome: 625 (Polished).
          ** NOTE TO SPECIFIER ** Select Dead Bolts required and identify on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions.
 
          2.5DEAD BOLTS
 
          A.Tubular Auxiliary Dead Bolts: DORMA DB800 Series.
          1.Features:
          a.Solid steel reinforced strike plate.
          2.Backset: 2-3/4 inch (70 mm) backset 1 inch (25.5 mm) throw dead bolt with hardened steel roller.
          3.Lock Cylinder:
          ** NOTE TO SPECIFIER ** Select cylinder as required for the project and delete the one not required.
          a.DORMA standard keyway with two nickel silver keys.
          b.Interchangeable core.
          c.Patented SKC key system.
          4.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Chrome: 626 (Satin).
          c.Brass: 605 (Bright).
          d.Brass: 606 (Satin).
          e.Bronze: 612 (Satin).
          f.Bronze: 613E (Satin.
 
          B.Tubular Auxiliary Dead Bolts: DORMA DB600 Series.
          1.Standards:
          a.ANSI Conformance - ANSI A156.5, Grade 2.
          2.Features:
          a.Solid steel reinforced strike plate.
          b.Adjustable 2-3/4 inch (70 mm) to 2-3/8 inch (60 mm) backset 1 inch (25.5 mm) throw dead bolt with hardened steel roller.
          3.Lock Cylinder:
          ** NOTE TO SPECIFIER ** Select cylinder as required for the project and delete the one not required.
          a.DORMA standard keyway with two nickel silver keys.
          b.Interchangeable core.
          c.Patented SKC key system.
          4.Latch Bolt: 1 inch (25.5 mm) Throw Latch Bolt:
          ** NOTE TO SPECIFIER ** Select option(s) as required for the project and delete the ones not required.1-1/8 square corner dead bolt standard for 600 Series dead bolts.
          a.1-1/8 inch (28.5 mm) by 2-1/4 inch (57 mm) front 1 inch (25.5 mm) diameter, 1 inch (25.5 mm) throw dead bolt with adjustable 2-3/8 inch (60 mm) to 2-3/4 inch (70 mm) backset. Square corner.
          b.1-1/8 inch (28.5 mm) by 2-1/4 inch (57 mm) front 1 inch (25.5 mm) diameter, 1 inch (25.5 mm) throw dead bolt with adjustable 2-3/8 inch (60 mm) to 2-3/4 inch (70 mm) backset. Drive in.
          5.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Chrome: 626 (Satin).
          c.Brass: 605 (Bright).
          d.Brass: 606 (Satin).
          e.Bronze: 612 (Satin).
          f.Bronze: 613E (Satin).
          ** NOTE TO SPECIFIER ** Select Conventional Core, Interchangeable Core or Patented Key Control cylinders from the following paragraphs and delete the ones not required. Identify on the Hardware Schedule. Coordinate with DORMA website or current literature.
 
          2.6CYLINDERS
          ** NOTE TO SPECIFIER ** DORMA conventional cylinders are available in rim, mortise, or key-in-knob.lever configurations. All cylinders are six pin.
 
          A.Conventional Lock Cylinder: ANSI A156.5, Grade 1, 6 pin cylinders.
          ** NOTE TO SPECIFIER ** DORMA 9000 Series, 800 Series and 700 Series are available with small format interchangeable core cylinders.
 
          B.Interchangeable Core Lock Cylinder: ANSI A156.5.
          1.Pin Count: 7 Pin.
          ** NOTE TO SPECIFIER ** DORMA SKC keys and cylinders are available for use with Standard and Interchangeable core lock systems. DORMA SKC cylinders are available for both small format interchangeable core (SFIC) and conventional (non-IC) cylinder applications. This product can be used wherever key control and key tracking are required.
 
          C.Patented Key Control Cylinders: DORMA SKC (Serialized Key Control) Cylinders, ANSI A156.5, Grade 1, seven nickel-silver pin cylinders.
 
          2.7KEYING
 
          A.Keying:
          ** NOTE TO SPECIFIER ** Select keying system(s) required from the following paragraphs and delete those not required.
          1.Keying: Factory Keyed to existing system..
          2.Keying: Factory Keyed as directed by Architect.
          3.Keying: Factory Keyed in like-groups
          4.Keying: Factory Keyed differently.
          5.Keying: Factory Master keyed.
          6.Keying: Factory Grand master keyed.
          7.Keying: Factory Great grand master keyed.
          ** NOTE TO SPECIFIER ** Select one of the following paragraphs for construction keying if required. Delete if not required.
          8.Include construction keying.
          9.Interchangeable Core with temporary construction cores.
          ** NOTE TO SPECIFIER ** Select one of the following two key paragraphs and delete the one not required. Select the second paragraph only for use with DORMA SKC Cylinders.
 
          B.Keys:
          1.Nickel silver. Stamp keys with "DO NOT DUPLICATE".
          2.Nickel silver. Each DORMASKC key and key blank is engraved with a unique serial number at the factory. Serial numbers are never repeated, allowing identification and tracking of each key.
          ** NOTE TO SPECIFIER ** Select systems applicable and delete those not required. Modify the number of key as required for the project.
          3.Supply keys in the following minimum quantities:
          a.Master keys 2.
          b.Grand master keys 2.
          c.Great grand master keys 10.
          d.Construction keys 10.
          e.Change keys 2.
 
          C.Key Cabinet:
          1.Construction: Sheet steel or aluminum construction, piano hinged door with cylinder type lock master keyed to building system.
          2.Size: Size for Project keys plus sufficient space for 10 percent growth.
          3.Key and key hook labeling system.
          4.Finish:
          a.Baked enamel.
          b.Brushed finish.
          c.Manufacturer's standard as selected by the Architect.
          ** NOTE TO SPECIFIER ** Select Exit devices required from the following paragraphs and delete the ones not required. Identify on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions.
 
          2.8EXIT DEVICES
 
          A.General:
          1.DORMA exit devices are listed by U.L. and C.U.L. under their continuing reinspection programs and conform to standards U.L. 10C and U.B.C. 7-2 (1997) positive pressure testing. They are BHMA certified to the requirements of ANSI A156.3 for Grade 1 exit devices.
          2.Exit Devices: Exit devices shall be type and function as listed in hardware sets. Use fire exit hardware where exit devices are scheduled for fire door assemblies. Where lever handle trim is specified, match lever trim on locksets. Furnish free wheeling lever trim as standard. Construct device touchbar, rail and cover assemblies of heavy gauge solid wrought materials for true architectural finishes. Provide cylinder dogging on all non-rated devices. Furnish all devices with stainless 3/4 inch (19 mm) throw deadlocking latchbolts.
          ** NOTE TO SPECIFIER ** DORMA's 9000 Series heavy-duty exit devices provide superior durability for high impact applications such as schools, universities, and other institutional or commercial buildings. The partial length touchpad permits field installation of options such as cylinder dogging and exit alarm. Consult DORMA for size and rating fire restrictions.
 
          B.9000 Series, Heavy Duty Exit Device: ANSI A156.3, Grade 1, heavy duty exit devices. Heavy duty RIM devices shall maintain a minimum latch bolt static load rating of 3,000 lbs.
          ** NOTE TO SPECIFIER ** Select Model(s) required and identify on the Hardware Schedule. Delete those not required.
          1.Model: 9100 Concealed Exit Device, panic listed only.
          2.Model: 9100LB Concealed Exit Device less bottom rod, panic listed only.
          3.Model: F9100 LB Concealed Exit Device less bottom rod, and fire listed.
          4.Model: F9100 Concealed Exit Device Fire listed
          5.Model: 9300 Rim Device, panic listed only.
          6.Model: F9300 Rim Device, panic and fire listed.
          7.Model: HCF9300 Rim Hurricane Rated Exit Device fire listed.
          8.Model: 9400 Surface Vertical Rod Exit Device, panic listed only.
          9.Model F9400 Surface Vertical Rod.
          10.Model: 9400 LB Concealed Exit Device less bottom rod.
          11.Model: F9400 LB Concealed Exit Device less bottom rod, and fire listed.
          12.Model: 9500 Mortise Exit Device, panic listed only.
          13.Model: F9500 Mortise Exit Device, and fire listed.
          14.Function:
          ** NOTE TO SPECIFIER ** Select the paragraph or function(s) required from the following paragraphs and include device functions on hardware schedule as required. Coordinate with DORMA website or current literature for descriptions.
          a.As noted on the hardware schedule attached to this section.
          b.As noted on the hardware schedule on the Drawings.
          c.YR03 Key retracts latch bolt
          d.YR08 Key locks or unlocks lever handle
          e.R03 Key retracts latch bolt (suffix J for interchangeable core)
          f.R08 Key locks or unlocks lever handle (suffix J for interchangeable core)
          g.HRTO5 Pull Plate with cylinder & thumbpiece
          h.HRT22 Pull Plate with thumbpiece
          i.PRTO3 Pull Plate with cylinder
          j.CD Cylinder Dogging
          k.LBR Less bottom rod
          l.F Fire label device
          m.BPA Battery alarm exit device kit
          ** NOTE TO SPECIFIER ** The following paragraph are for electronic functions. Delete if not required. Select function(s) required and identify on the Hardware Schedule. Delete those not required.
          n.DE Delayed egress
          o.ES Electronic latch retraction
          p.E Electronic locking or unlocking of trim
          q.MS Request to exit feature
          r.LM Monitors exit device latch bolt
          ** NOTE TO SPECIFIER ** Select power supply required for electronic functions and identify on the Hardware Schedule. Delete the power supply item not required. Delete all three paragraphs if electronic functions are not required.
          15.ES105 Power Transfers for all functions.
          16.PS501 Power Supply required for ES.
          a.Requirements:
          1)Input: 120 V.
          2)Input Circuit Protection: 1.0 A circuit breaker.
          3)Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.
          4)Output Circuit Protection: 4 A fuse.
          5)Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4 inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.
          17.ES100 Power Supply required for DE.
          a.Requirements:
          1)Input: 120 V.
          2)Input Circuit Protection: 1.0 A circuit breaker.
          3)Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.
          4)Output Circuit Protection: 4 A fuse.
          5)Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4 inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.
          ** NOTE TO SPECIFIER ** Specify trim(s) required and identify on the Hardware Schedule. Delete those items not required.
          18.Trim:
          a.Tubular Pull - T.
          b.Rectangular Pull - R.
          c.Curved Pull - C.
          d.Straight Pull - G.
          e.Lever Model: _____________.
          f.Knob Model: _____________.
          g.Cylinder: _____________.
          h.Mortise Cylinder: _____________.
          i.Electrified Trim: _____________.
          j.Battery Alarm: _____________.
          ** NOTE TO SPECIFIER ** Refer to DORMA's range of Exit Device product brochures for further details. Identify types required on the Hardware Schedule.
          19.Strikes: Provide types suitable for opening.
          20.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required. Note that the Antimicrobial protected clear powder coat finish is applied to tactile surfaces of the exit device and trim. Antimicrobial coated surfaces are continuously protected for the life of the product provided coating remains on coated surfaces. Note that Clear Powder Coat Finish can be applied over all finishes listed.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Brass: 605 (Bright).
          c.Brass: 606 (Satin).
          d.Bronze: 611 (Bright).
          e.Bronze: 612 (Satin).
          f.Bronze: 613E (Satin).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
          j.Stainless: 630 (Satin).
          k.Antimicrobial Protected Coating (AM).
          l.Clear Powder Coating (P).
          ** NOTE TO SPECIFIER ** DORMA's 9000 Narrow Stile Series heavy-duty exit devices provide superior durability for high impact applications such as schools, universities, and other institutional or commercial buildings. The partial length touchpad permits field installation of options such as cylinder dogging and exit alarm. Consult DORMA for size and rating fire restrictions.
 
          C.9000 Series Narrow Stile, Heavy Duty Exit Device: ANSI A156.3, Grade 1, heavy duty exit devices. Narrow Stile RIM devices shall maintain a minimum latch bolt static load rating of 1,500 lbs.
          ** NOTE TO SPECIFIER ** Select Model(s) required and identify on the Hardware Schedule. Delete those not required.
          1.Model: 9600 Concealed Exit Device, panic listed only.
          2.Model: 9600LB Concealed Exit Device less bottom rod, panic listed only.
          3.Model: F9600 LB Concealed Exit Device less bottom rod, and fire listed.
          4.Model: F9600 Concealed Exit Device Fire listed.
          5.Model: 9700 Rim Device, panic listed only.
          6.Model: F9700 Rim Device, panic and fire listed.
          7.Model: 9800 Surface Vertical Rod Exit Device, panic listed only.
          8.Model F9800 Surface Vertical Rod.
          9.Model: 9800 LB Concealed Exit Device less bottom rod.
          10.Model: F9800 LB Concealed Exit Device less bottom rod, and fire listed.
          11.Function:
          ** NOTE TO SPECIFIER ** Select the paragraph or function(s) required from the following paragraphs and include device functions on hardware schedule as required. Coordinate with DORMA website or current literature for descriptions.
          a.As noted on the hardware schedule attached to this section.
          b.As noted on the hardware schedule on the Drawings.
          c.ZR03 Key retracts latch bolt
          d.ZR08 Key locks or unlocks lever handle
          e.CD Cylinder Dogging
          f.LBR Less bottom rod
          g.F Fire label device
          h.BPA Battery alarm exit device kit
          ** NOTE TO SPECIFIER ** The following paragraph are for electronic functions. Delete if not required. Select function(s) required and identify on the Hardware Schedule. Delete those not required.
          i.DE Delayed egress
          j.ES Electronic latch retraction
          k.MS Request to exit feature
          l.LM Monitors exit device latch bolt
          ** NOTE TO SPECIFIER ** Select power supply required for electronic functions and identify on the Hardware Schedule. Delete the power supply item not required. Delete all three paragraphs if electronic functions are not required.
          12.ES105 Power Transfers for all functions.
          13.PS501 Power Supply required for ES.
          a.Requirements:
          1)Input: 120 V.
          2)Input Circuit Protection: 1.0 A circuit breaker.
          3)Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.
          4)Output Circuit Protection: 4 A fuse.
          5)Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4 inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.
          14.ES100 Power Supply required for DE.
          a.Requirements:
          1)Input: 120 V.
          2)Input Circuit Protection: 1.0 A circuit breaker.
          3)Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.
          4)Output Circuit Protection: 4 A fuse.
          5)Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4 inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.
          ** NOTE TO SPECIFIER ** Specify trim(s) required and identify on the Hardware Schedule. Delete those items not required.
          15.Trim:
          a.Tubular Pull - T.
          b.Rectangular Pull - R.
          c.Curved Pull - C.
          d.Straight Pull - G.
          e.Lever Model: _____________.
          f.Knob Model: _____________.
          g.Cylinder: _____________.
          h.Mortise Cylinder: _____________.
          i.Electrified Trim: _____________.
          j.Battery Alarm: _____________.
          ** NOTE TO SPECIFIER ** Refer to DORMA's range of Exit Device product brochures for further details. Identify types required on the Hardware Schedule.
          16.Strikes: Provide types suitable for opening.
          17.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required. Note that the Antimicrobial protected clear powder coat finish is applied to tactile surfaces of the exit device and trim. Antimicrobial coated surfaces are continuously protected for the life of the product provided coating remains on coated surfaces. Note that Clear Powder Coat Finish can be applied over all finishes listed.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Brass: 605 (Bright).
          c.Brass: 606 (Satin).
          d.Bronze: 611 (Bright).
          e.Bronze: 612 (Satin).
          f.Bronze: 613E (Satin).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
          j.Stainless: 630 (Satin).
          k.Antimicrobial Protected Coating (AM).
          l.Clear Powder Coating (P).
          ** NOTE TO SPECIFIER ** DORMA's 8000 Series exit devices with deadlocking latch bolts minimize forced entry while offering a low-cost solution to life safety requirements. Devices are available for labeled and non-labeled openings with rim, surface vertical rod, and surface vertical rod ''less bottom rod,'' along with a full range of trim options.
 
          D.8000 Series Heavy Duty Exit Device: ANSI A156.3, Grade 1, exit devices.
          ** NOTE TO SPECIFIER ** Select Model(s) required and identify on the Hardware Schedule. Delete those not required.
          1.Model: 8300 Rim Device, panic listed only.
          2.Model: F8300 Rim Device, panic and fire listed.
          3.Model: 8400 Surface Vertical Rod Exit Device, panic listed only.
          4.Model: F8400 Surface Vertical Rod Exit Device, panic listed and fire listed.
          5.Model: 8400LB Surface Vertical Rod Exit Device less bottom rod, panic listed only.
          6.Function:
          ** NOTE TO SPECIFIER ** Select the paragraph or function(s) required from the following paragraphs and include device functions on hardware schedule as required. Coordinate with DORMA website or current literature for descriptions.
          a.As noted on the hardware schedule attached to this section.
          b.As noted on the hardware schedule on the Drawings.
          c.R03 Key retracts latch bolt (suffix IC for interchangeable core)
          d.R08 Key locks or unlocks lever handle (suffix IC for interchangeable core)
          e.HTSO5 Pull Plate with cylinder and thumbpiece
          f.80O3P Pull with cylinder
          ** NOTE TO SPECIFIER ** Select options required from the following and delete those not required.
          g.LBR Less bottom rod
          h.F Fire label device
          i.BPA Battery alarm exit device kit
          ** NOTE TO SPECIFIER ** The following paragraph are for electronic functions. Delete if not required. Select function(s) required and identify on the Hardware Schedule. Delete those not required.
          j.ES Electronic latch retraction
          k.MS Request to exit feature
          l.LM Monitors exit device latch bolt
          ** NOTE TO SPECIFIER ** Select the following as required for electronic functions and identify on the Hardware Schedule. Delete all two paragraphs if electronic functions are not required.
          7.ES105 Power Transfer ES105 for all functions.
          8.ES100 Power Supply required for ES.
          a.Requirements:
          1)Input: 120 V.
          2)Input Circuit Protection: 1.0 A circuit breaker.
          3)Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.
          4)Output Circuit Protection: 4 A fuse.
          5)Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4 inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.
          ** NOTE TO SPECIFIER ** Specify trim required and identify on the Hardware Schedule. Delete those items not required.
          9.Trim:
          a.Tubular Pull - T.
          b.Rectangular Pull - R.
          c.Curved Pull - C.
          d.Straight Pull - G.
          e.Lever Model: _____________.
          f.Knob Model: _____________.
          g.Cylinder: _____________.
          h.Mortise Cylinder: _____________.
          i.Electrified Trim: _____________.
          j.Battery Alarm: _____________.
          ** NOTE TO SPECIFIER ** Refer to DORMA's range of Exit Device product brochures for further details. Identify types required on the Hardware Schedule.
          10.Strikes: Provide types suitable for opening.
          11.Finish:
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          a.Finish: As specified in the Door Hardware Schedule.
          b.Stainless: 630 (Satin).
          c.Powder Coated Aluminum: 689.
          d.Powder Coated Bronze: 691.
          e.Powder Coated Dark Duranodic: 695.
          f.Powder Coated Gold: 696.
          ** NOTE TO SPECIFIER ** Removable mullions can be used with paired doors where a full-width opening is only occasionally required. Doors are fitted with rim-type exit devices and normally function as single doors. Available in 8 foot or 10 foot lengths unless noted otherwise. Select mullion and color required and identify on the Hardware Schedule. Delete if not required.
 
          E.Removable Mullions:
          1.1310 Aluminum Mullion
          a.Finish: Aluminum: 628 (Satin).
          b.Finish: Bronze: 313 (Dark).
          2.1330 Steel Mullion
          a.Finish: Prime: 600.
          3.F1300-8 Steel Mullion: For use with U.L. listed fire exit devices. Standard in 8 foot length.
          a.Finish: Prime 600.
          4.1300-10 Steel Mullion: 10 foot non-fire-rated mullion
          a.Finish: Prime 600.
          5.F1340KR-8 Key Removable Steel Mullion: For use with U.L. listed fire exit devices. Standard in 8 foot length.
          a.Finish: Prime 600.
          6.1340KR-8 Key Removable Steel Mullion: 8 foot non-fire rated
          a.Finish: Prime 600.
          7.1340KR-10 Key Removable Steel Mullion: 10 foot non-fire-rated key removable mullion.
          a.Finish: Prime 600.
          8.HC1300 Hurricane Rated Steel Mullions: 8 foot non-fire-rated mullion 80 psf design pressure rating positive/negative deflection with HCF9300 rim device. Tested to Miami-Dade TAS 201, 202, 203.
          a.Finish: Prime 600.
          9.1340SK Storage Kit for use with 1340KR Series Mullions: Includes a top fitting with cylinder, bottom fitting, mounting plate, floor anchors and mounting fasteners.
          ** NOTE TO SPECIFIER ** Select Surface Door Closers required from the following paragraphs and delete the ones not required. Identify mounting, arm and detail options on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions.
 
          2.9SURFACE DOOR CLOSERS
 
          A.Closers used in conjunction with overhead stops and holders shall be templated and coordinated to function properly. Properly detail closers to meet application requirements by providing drop plates, brackets, etc. to meet application and installation requirements as indicated.
 
          B.TS93 Series: ANSI A156.4, Grade 1, compact design surface door closer with unique cam and roller design.
          1.Model TS93-1 features adjustable spring sizes from 1 to 5 and meets the requirements of ANSI A117.1 and ADA for interior and exterior barrier-free accessibility.
          2.Model TS93-5 features adjustable spring sizes from 5 to 6 plus 50 percent adjustment for wide, tall or heavy doors.
          3.Model TS93 PKT for pocket door applications.
          4.Standard independent, latch, sweep and backcheck intensity valves.
          5.Compliant with UL10C for positive pressure.
          6.Non-handed.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost.
          7.Finish: As specified in the Door Hardware Schedule.
          8.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          9.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
 
          C.8900 Series: ANSI A156.4, Grade 1, heavy duty surface door closer.
          1.Model 8916 for interior and exterior applications features adjustable spring sizes from 1 to 6 and meets ANSI A117.1 and ADA for barrier-free accessibility.
          2.Model 8956 features adjustable spring sizes from 5 to 6 plus 50 percent adjustment for wide, tall or heavy doors.
          3.Compliant with UL10C for positive pressure.
          4.Certified to 10 million cycles by a recognized test lab.
          5.Non-handed.
          6.Featuring full range spring power adjustment and backcheck, with a narrow projection full cover and flatform style arm.
          7.Door control also features a backcheck positioning adjustment for parallel arm applications, to maintain an ANSI backcheck range similar to regular and top jamb applications.
          8.Independent sweep and latch non-critical closing speed adjustment.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost.
          9.Finish: As specified in the Door Hardware Schedule.
          10.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          11.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
 
          D.8600 Series: ANSI A156.4, Grade 1, surface door closer.
          1.Model 8616 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility.
          2.Model 8616 features adjustable spring sizes from 1 to 6.
          3.Compliant with UL10C for positive pressure.
          4.Non-handed.
          5.Door control also features a backcheck positioning adjustment for parallel arm applications, to maintain an ANSI backcheck range similar to regular and top jamb applications.
          6.Independent sweep and latch non-critical closing speed adjustment.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost.
          7.Finish: As specified in the Door Hardware Schedule.
          8.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          9.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
 
          E.7400 Series: ANSI A156.4, Grade 1, surface door closer.
          1.Model 7414 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility. Features adjustable spring sizes from 1 to 4.
          2.Model 7436 for interior and exterior applications. Features adjustable spring sizes from 3 to 6.
          3.Compliant with UL10C for positive pressure.
          4.Non-handed.
          5.Door control features a backcheck adjustment and adjustable spring sizes.
          6.Independent sweep and latch non-critical closing speed adjustment.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost.
          7.Finish: As specified in the Door Hardware Schedule.
          8.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
 
          F.7300 Series: ANSI A156.4, Grade 1, surface door closer.
          1.Features fixed spring sizes 2, 3, 4, and 5.
          2.Compliant with UL10C for positive pressure.
          3.Independent sweep and latch non-critical closing speed adjustment.
          4.Non-handed.
          5.Adjustable backcheck.
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          6.Finish: As specified in the Door Hardware Schedule.
          7.Standard Sprayed Finish: As selected.
          8.Custom Finish: Optional Special color.
 
          G.STA Series: ANSI A156.4, Grade 1, corrosion resistant surface door closer.
          1.Model STA8616 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility. Model 8616 features adjustable spring sizes from 1 to 6.
          2.Model STA7414 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility. Model 7414 features adjustable spring sizes from 1 to 4.
          3.Model 7436 features adjustable spring sizes from 3 to 6.
          4.Compliant with UL10C for positive pressure.
          5.Non-handed.
          6.Stainless steel S-IS option available for use in severe climate conditions, or where there is exposure to corrosive environments.
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          7.Finish: As specified in the Door Hardware Schedule.
          8.Standard Sprayed Finish: As selected by the Architect.
          9.Custom Paint Finish: Optional Special color as selected by the Architect.
 
          H.Spring Assist Arm Dead Stop: ANSI A156.4, Grade 1, DORMA Spring Assist Arm Systems for high volume high traffic applications. Meets requirements for UL10C for positive pressure (non-hold open).
          1.Model S-DS heavy duty, dead stop, parallel arm, pull side mount.
          2.Model S-IS regular, dead stop and top jamb mount, push side mount.
          ** NOTE TO SPECIFIER ** Select arm type(s) required and delete those not required.
          3.Arms:
          a.Heavy-Duty Parallel Arm x Spring Door Saver:
          b.Regular x Spring Integra Stop Arm:
          c.Top Jamb x Spring Integra Stop Arm
          ** NOTE TO SPECIFIER ** Select finish required and delete those not required.
          4.Finish: As specified in the Door Hardware Schedule.
          5.Standard Sprayed Finish: As selected.
          6.Custom Paint Finish: Optional Special color as selected by the Architect.
          7.Finish: 689 (Aluminum).
          8.Finish: 690 (Dark Bronze).
          9.Finish: 691 (Light Bronze, Dull).
          10.Finish: 695 (Dark Duronodic Bronze).
          11.Finish: 696 (Gold).
          12.Finish: 693 (Black).
          13.Finish: 600 Primer.
          ** NOTE TO SPECIFIER ** Select Concealed Door Closers required from the following paragraphs and delete the ones not required. Identify application and detail options on the Hardware Schedule. Packages are available for BTS floor closers and RTS overhead concealed closer for 3/4 inch offset, 1-1/2 inch offset and independently hung doors. Coordinate with DORMA website or current literature for descriptions.
 
          2.10CONCEALED DOOR CLOSERS
          ** NOTE TO SPECIFIER ** BTS75V Series closers capable of controlling doors weighing up to 260 pounds and measuring up to 3 feet 6 inches for interior doors and 3 feet wide for exterior doors.
 
          A.BTS75V Series: ANSI A156.4, Grade 1, compact design floor-concealed door closers.
          1.Adjustable spring power allows the necessary adjustment.
          2.Controlled closing with two independent valves.
          3.Model BTS75V BF meets the requirements of ANSI A117.1 and ADA for barrier-free accessibility.
          4.Non-handed.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          5.Finish: As specified in the Door Hardware Schedule.
          6.Standard Sprayed Finish: As selected as selected by the Architect.
          7.Custom Paint Finish: Optional Special color as selected by the Architect.
          8.Plated Finish: Brass: 605 (Bright).
          9.Plated Finish: Brass: 606 (Satin).
          10.Plated Finish: Bronze: 611 (Bright).
          11.Plated Finish: Bronze: 612 (Satin).
          12.Plated Finish: Bronze: 613 (Dark).
          13.Plated Finish: Nickel: 618 (Bright).
          14.Plated Finish: Nickel: 619 (Satin).
          15.Plated Finish: Chrome: 625 (Bright).
          16.Plated Finish: Chrome: 626 (Satin).
          ** NOTE TO SPECIFIER ** BTS80 Series closers capable of controlling interior or exterior doors weighing up to 660 pounds and measuring up to 4 feet wide exterior and 4 feet 6 inches interior.
 
          B.BTS80 Series: ANSI A156.4, Grade 1, compact design floor-concealed door closers.
          1.Field selectable either multipoint hold open between 75 and 175 degrees or selectable delayed action to allow delayed closing from 175 to 75 degrees.
          2.A wide selection of interchangeable spindles offers suitability for virtually any floor covering or threshold application.
          3.Model BTS80 E for exterior application.
          4.Model BTS80 BFE: Meets ADA barrier-free accessibility requirements for exterior use.
          5.Non-handed.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          6.Finish: As specified in the Door Hardware Schedule.
          7.Standard Sprayed Finish: As selected as selected by the Architect.
          8.Custom Paint Finish: Optional Special color as selected by the Architect.
          9.Plated Finish: Brass: 605 (Bright).
          10.Plated Finish: Brass: 606 (Satin).
          11.Plated Finish: Bronze: 611 (Bright).
          12.Plated Finish: Bronze: 612 (Satin).
          13.Plated Finish: Bronze: 613 (Dark).
          14.Plated Finish: Nickel: 618 (Bright).
          15.Plated Finish: Nickel: 619 (Satin).
          16.Plated Finish: Chrome: 625 (Bright).
          17.Plated Finish: Chrome: 626 (Satin).
          ** NOTE TO SPECIFIER ** ITS96-1 Series closers suitable for interior wood, hollow metal and aluminum doors a minimum of 1-3/4 inch thick and weighing up to 125 pounds and measuring up to 3 feet wide. Verify with door manufacturer for fire rating restrictions.
 
          C.ITS96-1 Series: Compact design overhead-concealed door closers.
          1.Aluminum alloy body with high compression steel springs and steel cams and rollers for doors opening up to 130 degrees maximum.
          2.Two noncritical thermostatic valves to separately control sweep and latch speeds and provide constant closing speeds.
          3.Adjustable springs to meet the requirements of ADA for barrier-free accessibility.
          4.Compliant with UL10C for positive pressure.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost.
          5.Finish: As specified in the Door Hardware Schedule.
          6.Standard Sprayed Finish: As selected as selected by the Architect.
          7.Custom Paint Finish: Optional Special color as selected by the Architect.
          8.Finish: Bronze: 691 (Dull).
          9.Finish: Statuary Bronze: 690.
          10.Finish: Dark Duranodic Bronze: 695.
          11.Finish: Gold: 696.
          12.Finish: Black: 693.
          13.Finish: Primed for Painting: 600.
          ** NOTE TO SPECIFIER ** RTS88 Series closers suitable for single or double acting wood, hollow metal and aluminum doors a minimum of 1-3/4 inch thick and weighing up to 250 pounds and interior doors measuring up to 4 feet wide and exterior doors measuring up to 3 feet 6 inches wide. Not approved for use on Fire Rated Doors.
 
          D.RTS88 Series: Compact design overhead-concealed door closers.
          1.Cast Iron body with steel springs and steel cams and rollers for doors opening up to 90 to 105 degrees maximum.
          2.Two noncritical valves to separately control sweep and latch speeds and provide constant closing speeds.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          3.Finish: As specified in the Door Hardware Schedule.
          4.Standard Sprayed Finish: As selected as selected by the Architect.
          5.Custom Paint Finish: Optional Special color as selected by the Architect.
          6.Plated Finish: Brass: 605 (Bright).
          7.Plated Finish: Brass: 606 (Satin).
          8.Plated Finish: Bronze: 611 (Bright).
          9.Plated Finish: Bronze: 612 (Satin).
          10.Plated Finish: Bronze: 613 (Dark).
          11.Plated Finish: Nickel: 618 (Bright).
          12.Plated Finish: Nickel: 619 (Satin).
          13.Plated Finish: Chrome: 625 (Bright).
          14.Plated Finish: Chrome: 626 (Satin).
          ** NOTE TO SPECIFIER ** Select Low Energy Operators and options required from the following paragraphs and delete the features not required. Identify mounting, arm, control and detail options on the Hardware Schedule. Accommodates doors 36 inches (914 mm) 100 lb to 48 inches (1219 mm) 200 lbs. Coordinate with DORMA website or current literature for descriptions. Consult DORMA for coordination with electrified hardware and point to point and riser diagrams.
 
          2.11LOW ENERGY OPERATORS
 
          A.ED800 Series: ANSI A156.19, Grade 1, surface applied power assist and low energy power operated doors.
          1.Closer with latch, sweep and backcheck intensity valves.
          2.Compliant with UL10C for positive pressure.
          3.Non-handed.
          ** NOTE TO SPECIFIER ** Select wall switch(s) required and delete those not required.
          4.Wired Wall Switch: WS-1 with Logo and PRESS TO OPEN, 6 inch (152 mm) by 6 inch (152 mm) stainless steel wall plate.
          5.Wired Narrow Frame Wall Switch: FS-1 with Logo and PRESS TO OPEN, 1-3/4 inch (44 mm) by 4.5 inch (114 mm) stainless steel wall plate.
          6.Wireless Wall Switch: WSRFT-1 with Logo and PRESS TO OPEN, 6 inch (152 mm) by 6 inch (152 mm) stainless steel wall plate with 1-3/4 inch (44 mm) deep mounting box.
          7.Receiver: 800 RFR Hard wired receiver mounted separately.
          8.Power requirements: 120 VAC, 50/60 Hz, 2 amp.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required. Plated finishes are also available contact DORMA for availability and cost. Plated finishes are also available contact DORMA for availability and cost.
          9.Finish: As specified in the Door Hardware Schedule.
          10.Standard Sprayed Finish: As selected by the Architect.
          11.Custom Paint Finish: Optional Special color as selected by the Architect.
          12.Finish: 689 (Aluminum).
          13.Finish: 690 (Dark Bronze).
          14.Finish: 691 (Light Bronze).
          15.Finish: 693 (Black).
          16.Finish: 695 (Dark Duronodic Bronze).
          17.Finish: 696 (Gold).
          18.Finish: 600 Primer.
          ** NOTE TO SPECIFIER ** Select Fire/Life Safety Devices and options required from the following paragraphs and delete the features not required. Identify mounting, arm, control and detail options on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions.
 
          2.12FIRE/LIFE SAFETY DEVICES
 
          A.EM Series: ANSI A156.15, Grade 1 electromagnetic door holder device.
          1.Floor mount. Single or double magnet.
          2.Semi-Flush wall mount.
          3.Surface wall mount.
          4.Power requirements: 120 VAC, 24 VDC or 24 VAC input.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          5.Finish: As specified in the Door Hardware Schedule.
          6.Standard Finish: As selected by the Architect.
          7.Powder Coated Finish: 689 (Aluminum).
          8.Powder Coated Finish: 695 (Dark Duronodic Bronze).
          9.Sprayed Finish: 696 (Gold).
          ** NOTE TO SPECIFIER ** Select miscellaneous trim required from the following paragraphs and delete those not required. Add additional trim as required. Identify detail options on the Hardware Schedule. Coordinate with DORMA website or current literature for descriptions.
 
          2.13MISCELLANEOUS TRIM
 
          A.Push/Pulls: ANSI A156.6; push plates minimum 0.050 inch (1.27 mm) thick.
          1.Type:
          ** NOTE TO SPECIFIER ** Select type(s) required and delete those not required.
          a.Straight.
          b.Offset.
          c.Flush.
          d.Straight push-pull.
          e.Offset push-pull.
          f.Push-pull plate.
          g.Provide as indicated on the Schedule.
          2.Size: Push plates shall be ANSI J302, size 4 inches (102 mm) by 16 inches (406 mm), thickness .050 inch.
          3.Size: Pull plates shall be ANSI J405, size 4 inches (102 mm) by 16 inches (406 mm), thickness .050 inch.
          4.Cut plates for cylinder or thumb piece when used with deadlock.
          5.Provide with through bolts to secure from opposite door face.
          6.Finish: As specified in the Door Hardware Schedule.
 
          B.Flush Bolts: ANSI A156.16 Grade 1 top and bottom flush bolts, with dust-proof floor strike.
          ** NOTE TO SPECIFIER ** Select type(s) required and delete those not required.
          1.Manual.
          2.Automatic.
          3.Provide as indicated on the Schedule.
          4.Finish: As specified in the Door Hardware Schedule.
 
          C.Kickplates, Mop Plate, Armor Plates: ANSI A156.6, metal; height indicated in Schedule by 1 inch (25 mm) less than door width:
          ** NOTE TO SPECIFIER ** Select paragraph(s) required and delete those not required.
          1.Minimum 0.050 inch (1.27 mm) thick stainless steel.
          2.Height: 8 inches (203 mm).
          3.Width: 2 inches (51 mm) less than the width of each door..
          4.Provide as indicated on the Schedule.
 
          D.Weatherstripping and thresholds specified in Section 08720.
 
          E.Fire rated gaskets at perimeter of doors specified in Section 07840.
 
          F.Stops: Provide for all doors to control the desired limit of opening helping to prevent damage to adjacent walls, columns, equipment, the door or its hardware
          1.Provide floor or wall stops when overhead stops have not been listed except in areas where their location would impede traffic. Stops of correct height shall be used on exterior and interior doors.
          2.Doors with surface closers may be provided with S-DS or S-IS dead stop arms
          3.Use roller type stops in areas where the interfering swing of one door may cause damage through contact with another door.
          4.Wall Stops: ANSI A156.1, Grade 1, with no visible screws:
          ** NOTE TO SPECIFIER ** Select type(s) required and delete those not required.
          a.3 inch (75 mm) wall stop.
          b.2-1/2 inch (6.35 mm) wall stop.
          c.Convex pad wall stop.
          d.Concave pad wall stop.
          e.Provide as indicated on the Schedule.
          f.Finish: As specified in the Door Hardware Schedule.
          5.Floor Stops: ANSI A156.1 Grade 1:
          ** NOTE TO SPECIFIER ** Select type(s) required and delete those not required.
          a.Dome type.
          b.Standard floor type.
          c.Standard floor type with no visible screws
          d.Provide as indicated on the Schedule.
          e.Finish: As specified in the Door Hardware Schedule.
          6.Roller Latch Angle Stops: Special angle stop ANSI A156.16 Type E19111.
 
          G.Standard Duty Door Stops and Holders: 700 Series, Standard Duty door stops and holders. Conforms to ANSI A156.8 Grade 3.
          1.Type:
          ** NOTE TO SPECIFIER ** Select type required and delete those not required.
          a.700S: Surface applied stop only.
          b.700H: Surface applied stop and hold open.
          c.700F: Surface applied stop friction.
          d.710S: Concealed stop only.
          e.710H: Concealed hold open.
          f.710F: Concealed stop friction.
          2.Built-in cushioned stop.
          3.Non-handed.
          4.Adjustable friction tension with friction stop unit
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          5.Finish: As specified in the Door Hardware Schedule.
          6.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          7.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
 
          H.Heavy Duty Door Stops and Holders: 900 Heavy-Duty door stops and holders. Conforms to ANSI A156.8 Grade 1.
          1.Type:
          ** NOTE TO SPECIFIER ** Select type required and delete those not required.
          a.900S: Surface applied stop only.
          b.900H: Surface applied stop and hold open.
          c.900F: Surface applied stop friction.
          d.910S: Concealed stop only.
          e.910H: Concealed hold open.
          f.910F: Concealed stop friction.
          2.Built-in cushioned stop
          3.Non-handed
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          4.Finish: As specified in the Door Hardware Schedule.
          5.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          6.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
 
          I.Coordinators: GSR Series, ANSI A156.4 Grade 1, coordinator system for proper sequential closing of pairs of doors equipped with astragals or exit devices.
          ** NOTE TO SPECIFIER ** Select type(s) required and delete those not required.
          1.TS93 GSR with two TS93 closers and a GSR mechanism to control sequential closing for pairs of doors.
          2.TS93-1 GSR meets the requirements of ANSI A117.1 and ADA for barrier-free accessibility.
          3.8956 GSR Series with two 8956 surface closers and a GSR mechanism to control sequential closing for pairs of doors.
          4.Non-handed.
          5.Compliant with UL10C for positive pressure.
          6.Active door field-selectable.
          ** NOTE TO SPECIFIER ** Select finish and color required and delete those not required.
          7.Finish: As specified in the Door Hardware Schedule.
          8.Standard Sprayed Finish: As selected.
          a.689 (Aluminum).
          b.690 (Dark Bronze).
          c.691 (Light Bronze).
          d.693 (Black).
          e.695 (Dark Duronodic Bronze).
          f.696 (Gold).
          g.600 Primer.
          h.Custom Paint Finish: Optional Special color as selected by the Architect.
          9.Plated Finish:
          a.Brass: 605 (Bright).
          b.Brass: 606 (Satin).
          c.Bronze: 611 (Bright).
          d.Bronze: 612 (Satin).
          e.Bronze: 613 (Dark).
          f.Nickel: 618 (Bright).
          g.Nickel: 619 (Satin).
          h.Chrome: 625 (Bright).
          i.Chrome: 626 (Satin).
          ** NOTE TO SPECIFIER ** Coordinate silencers with metal door frame specification and delete the following paragraph if silencers are provided with metal door frames.
 
          J.Silencers for Metal Door Frames: ANSI A156.16, Type L03011; grey rubber, minimum diameter 1/2 inch (13 mm); fabricated for drilled-in application to frame, specifically designed to form an air pocket to absorb shock and reduce noise of door closing. Provide 2 silencers for each pair of doors, 3 silencers for each single door.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
 
          B.Verify doors and frames are ready to receive door hardware and dimensions are as indicated on shop drawings.
 
          C.Verify electric power is available to power operated devices and is of correct characteristics.
 
          D.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
 
          B.Coordinate mounting heights with door and frame manufacturers. Use templates provided by hardware item manufacturer.
 
          C.Install with fasteners provided by hardware item manufacturer.
 
          D.Adjust hardware for smooth operation.
 
          3.3PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
          ** NOTE TO SPECIFIER ** Consult an Architectural Hardware Consultant (AHC) or other qualified person for recommended schedule format. Coordinate hardware sets with door and frame schedule. Refer to NAAMM Standard HMMA 810, for an example door and frame schedule. If applicable, identify electrical characteristics for each hardware item. Consider the following sample when developing Project schedule.
 
          3.4DOOR HARDWARE SCHEDULE
 
          A.Provide the following hardware sets ........
Hardware Set 1: Fire rated.
Hinges:
Lock:
Closer:
Kickplate:
Gaskets:
Floor Stop:
Hardware Set 2: Non-fire rated.
Hinges:
Latch Set:
Floor Stop:
Silencers:
 
         