MasterFormat: 95
Download this Compartments and Cubicles Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
General Partitions Mfg. Corp. Compartments and Cubicles
 
         
SECTION 10150
 
         
COMPARTMENTS AND CUBICLES
 
         
          ** NOTE TO SPECIFIER ** General Partitions Manufacturing Corp.; powder coated enameled steel, stainless steel, high density polymer, solid phenolic, fiberglass reinforced plastic and plastic laminate faced toilet compartments, screens, shower and dressing compartments and cubicles.
          This section is based on the products of General Partitions Manufacturing Corp., which is located at:
1702 Pennsylvania Dr.
P. O. Box 8370
Erie, Pennsylvania 16505-0370
Tel: (814) 833-1154
Fax: (814) 838-3473
Email: ( Click Here ) to e-mail General Partitions.
Website: www.generalpartitions.com
( Click Here ) for additional information.

Overview: General Partitions has over 50 years experience manufacturing the finest quality toilet partition in the industry. We at General Partitions Mfg. Corp. are proud of our reputation. We fabricate and ship on time. Our customer service is handled by people who care and can answer your questions.

Custom Designs: General Partitions Mfg. Corp. provides standard panel sizes and custom designs. Contact General Partitions for availability and assistance in planning custom sizes and configurations. We work with the architect and owner to incorporate the latest materials and design features for a given product. We will work up a cost base for estimating purposes and assist in engineering the project.

Construction: General's standard panel with Ribcore sound deadening reinforcement is offered as a standard at no extra charge. Sheet metal skins are bonded under pressure, to each cell of the core with an adhesive impervious to moisture. Lighter weight, greater strength and permanently flat panels are provided through this type of construction.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project. If more than one type of partition is required, indicate which type is used where, either on the drawings or in the Schedule Article of this section.
 
          A.Powder-coated enameled steel compartments and cubicles.
 
          B.Stainless steel compartments and cubicles.
 
          C.Plastic laminate compartments and cubicles.
 
          D.Solid phenolic compartments and cubicles.
 
          E.High density polymer compartments and cubicles.
 
          F.Fiberglass reinforced plastic compartments and cubicles.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 05500 - Metal Fabrications: Structural support system for ceiling hung toilet partitions.
 
          B.Section 06110 - Wood Framing: Concealed wood framing and blocking for partition support.
 
          C.Section 09255 - Gypsum Board Systems: Blocking in metal stud partitions for wall anchorage of toilet partitions.
 
          D.Section 10800 - Toilet and Bath Accessories: Accessories mounted on toilet partitions.
 
          E.Section 15400 - Plumbing Fixtures and Equipment: Shower head, valves, and plumbing for shower cabinets.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ADA - Americans with Disabilities (ADA) Standards for Accessible Design.
 
          B.ANSI A117.1 - American National Standard for Buildings and Facilities - Providing Accessibility and Usability for Physically Handicapped People.
 
          C.ANSI A208.1 - Mat Formed Wood Particleboard.
 
          D.ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
 
          E.ASTM A167 - Stainless and Heat Resisting Chromium-Nickel Steel Plate, Sheet, and Strip.
 
          F.ASTM A526 - Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Commercial Quality.
 
          G.NEMA LD-3 - High Pressure Decorative Laminates.
 
          H.UFAS - Uniform Federal Accessibility Standards.
 
          1.4SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.( Product Data ): Manufacturer's data sheets on each product to be used, including:
          1.Literature indicating typical panel, pilaster, door, hardware and fastening.
          2.Preparation instructions and recommendations.
          3.Storage and handling requirements and recommendations.
          4.Installation methods.
          5.Maintenance instructions.
 
          C.Shop Drawings:
          1.Dimensioned plans indicating layout of toilet partitions.
          2.Dimensioned elevations indicating heights of doors, pilasters, separation partitions, and other components; indicate locations and sizes of openings in compartment separation partitions for toilet and bath accessories to be installed in partitions; indicate floor and ceiling clearances.
          3.Details indicating anchoring components (bolt layouts) and methods for project conditions; indicate components required for installation, but not supplied by compartment and cubicle manufacturer.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          D.Selection Samples: For each finish product specified, one complete set of color selection guides representing manufacturer's full range of available colors, textures and patterns.
 
          E.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, texture and pattern.
 
          F.Manufacturer's Certificates: Certify products meet or exceed specified requirements.
          **NOTE TO SPECIFIER.** Delete selection if products with baked enamel finish not required. Revise quantity as required.
 
          G.Touch-Up Paint: Provide 5 ounces of matching paint for field touch-up of baked enamel finish.
 
          1.5DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging until ready for installation.
          **NOTE TO SPECIFIER.** The following paragraphs apply to Laminate, Phenolic, and HDPE products. Delete if not required.
 
          B.Lay cartons flat, with adequate support to ensure flatness and to prevent damage to pre-finished surfaces.
 
          C.Do not store where ambient temperature exceeds 120 degrees F (49 degrees C).
 
          1.6PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          B.Do not deliver materials or begin installation until building is enclosed, with complete protection from outside weather, and building temperature maintained at a minimum of 60 degrees F (15.6 degrees C).
 
          1.7QUALITY ASSURANCE
          **NOTE TO SPECIFIER ** Barrier free requirements will depend on type of project and local jurisdiction. Edit and include the following paragraph if toilet and shower compartments need to accommodate persons with physical handicaps.
 
          A.Products and installation shall comply with the following:
          1.ADA Standards.
          2.ANSI A117.1.
          3.UFAS.
 
          1.8WARRANTY
 
          A.Manufacturer's Warranty for Partitions: Provide warranty for repair or replacement for defects in materials, hardware or workmanship for the period specified below from the date of Substantial Completion, when properly stored, handled and maintained under normal usage.
          ** NOTE TO SPECIFIER ** Delete warranty provisions for products not required for the Project.
          1.Powder Coated Steel Partitions: 1 year.
          2.Plastic Laminate Partitions: 1 year.
          3.Stainless Steel Partitions: 10 years.
          4.Solid Phenolic Core Partitions: 15 years.
          5.High Density Polymer Partitions: 15 years.
          6.Fiberglass Reinforced Plastic Partitions: 15 years.
 
          1.9COORDINATION
 
          A.Coordinate Work with placement of support framing and anchors in walls and ceilings.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: General Partitions Mfg. Corp., which is located at: 1702 Peninsula Dr. P. O. Box 8370 ; Erie, PA 16505; Tel: 814-833-1154; Fax: 814-838-3473; Email: request info; Web: www.generalpartitions.com
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 Section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
          2.2POWDER COATED ENAMELED STEEL UNITS
          ** NOTE TO SPECIFIER ** Delete product types not required.
 
          A.Toilet Partitions:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Supported: Panels supported by pilasters anchored to floor; General Partitions Manuf. Co. Series 30.
          2.Floor Supported with Headrail: Panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Series 40.
          3.Ceiling Hung: Panels supported by ceiling hung pilasters; General Partitions Manuf. Co. Series 50.
          4.Floor to Ceiling: Panels supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Series 60.
          5.Extra Height Floor to Ceiling: Extra height panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Eastern Panels.
 
          B.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Braced: Screens attached to wall and braced by pilasters anchored to floor; General Partitions Manuf. Co. FBS-1.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-1.
          3.Wall Hung Screen: Screens hung from wall with brackets; General Partitions Manuf. Co. WHS-1.
          4.Wall Hung Flange: Screens hung from wall with continuous aluminum channel; General Partitions Manuf. Co. WHF-1.
          5.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling Model.
 
          C.Privacy Screens:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Screens can be placed between urinals or used to block view at toilet room entrance. Model FBS-1 - Floor Braced Screen, Model FSH-1 - Floor Supported with Headrail, and Floor to Ceiling Model are recommended for privacy screens at locations other than between urinals.
          1.Floor Braced: Screens supported by pilasters anchored to floor; General Partitions Manuf. Co. FBS-1.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-1.
          3.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling.
 
          D.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Shower Cabinets can be installed as single units or as multiple units. Cabinets are provided with precast terrazzo receptors in three designs.
          1.Standard Design: Three-sided rectangular shape with a curb at opening; General Partitions Manuf. Co. Standard.
          2.Triangular Design: Two sided triangular shape for corner installation with a curb at opening; General Partitions Manuf. Co. Neo-corner.
          3.Handicapped Design: Rectangular shape with a ramped design to accommodate persons with physical handicaps; General Partitions Manuf. Co. Handicapped.
 
          E.Double-Wall Shower: Double-wall Ribcore insulation with pre-cast terrazzo receptor.
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Standard Design: 32 inches by 32 inches by 82 inches (813 mm by 813 mm by 2083 mm).
          2.Standard Design: 36 inches by 36 inches by 82 inches (914 mm by 914 mm by 2083 mm).
          3.Standard Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          4.Triangular Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          5.Handicapped Design: 40 inches by 48 inches by 82 inches (1016 mm by 1219 mm by 2083 mm).
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no shower and dressing compartments. Different configurations and sizes of shower and dressing compartments are available.
 
          F.Shower and Dressing Compartments: Combination Shower and Dressing Compartments: Formed from partitions supported by pilasters anchored to floor and braced overhead with headrails to configuration and sizes indicated on Drawings.
 
          G.Panels:
          1.Material: Fabricate from two galvanized steel face sheets pressure bonded to honeycomb core.
          2.Face sheets: Steel sheet, ASTM A526 with G60 zinc coating. Minimum thickness:
          a.Partition, Door, Urinal Screen, Privacy Screen, and Shower Panels: 22 gage.
          b.Pilaster Panels: 22 gage; 20 gage for ceiling hung.
          3.Core: Sound deadening, moisture resistant, impregnated cardboard honeycomb. Adhere each cell to face sheets with moisture impervious adhesive.
          4.Edges: Face sheets shall have die drawn steel, radiused, smooth molding attached to all four panel sides.
          5.Corner Reinforcement: At each panel corner, formed steel corner reinforcement shall be mechanically fused to panel edges.
          ** NOTE TO SPECIFIER ** Retain the following paragraph for Series 30 - Floor Supported and Model FBS-1 - Floor Supported Urinal Screen.
          6.Equip bottom end of pilasters with steel bar saddle for attachment to floor with threaded steel studs and leveling nuts.
          ** NOTE TO SPECIFIER ** Retain the following paragraph for Series 50 - Ceiling Hung.
          7.Equip top end of pilasters with steel bar saddle for attachment to ceiling support member with threaded steel studs and leveling nuts.
 
          H.Dimensions:
          1.Toilet Compartment Panel Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. Eastern panels are mounted 3 inches (76 mm) above the floor providing greater privacy.
          a.Panel Height, Standard: 58 inches (1473 mm).
          b.Panel Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Retain one of the following eight paragraphs. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          c.Panel Width: 48 inches (1219 mm).
          d.Panel Width: 54 inches (1372 mm).
          e.Panel Width: 57 inches (1448 mm).
          f.Panel Width: 60 inches (1524 mm).
          g.Panel Width: 61-1/4 inches (1556 mm).
          h.Panel Width: 66 inches (1676 mm).
          i.Panel Width: 72 inches (1829 mm).
          j.Panel Width: 78 inches (1981 mm).
          k.Panel Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          l.As indicated on Drawings.
          2.Door Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions.
          a.Inswinging Door Height, Standard: 58 inches (1473 mm).
          b.Inswinging Door Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          c.Inswinging Door Width: 24 inches (610 mm).
          d.Outswinging Door Width: 32 inches (813 mm) clear opening.
          e.Door Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          f.As indicated on Drawings.
          3.Pilaster Size:
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 and Series 50 partitions.
          a.Pilaster Width: 8 inches (203 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying FSH-1 urinal and privacy screens.
          b.Pilaster Width: To suit compartment size.
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 partitions, FBS-1 screens, or FSH-1 urinal and privacy screens.
          c.Pilaster Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 40 partitions, Shower and Dressing Compartments, or FSH-1 urinal and privacy screens.
          d.Pilaster Height: 82 inches (2083 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 50 and Series 60 partitions, and Floor to Ceiling urinal and privacy screens.
          e.Pilaster Height: Extends from floor to ceiling. Refer to Drawings.
          f.Pilaster Thickness: 1-1/4 inches (32 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          g.As indicated on Drawings.
          4.Urinal Screens:
          ** NOTE TO SPECIFIER ** Retain two of the following four paragraphs for urinal screens. Standard height for WHS-1 and WHF-1 urinal screens is 42 inches (1067 mm) and for FBS-1, FSH-1, and Floor to Ceiling urinal screens is 58 inches (1473 mm).
          a.Urinal Screen Width: 18 inches (457 mm).
          b.Urinal Screen Width: 24 inches (610 mm).
          c.Urinal Screen Height: 42 inches (1067 mm).
          d.Urinal Screen Height: 58 inches (1473 mm).
          5.Privacy Screens:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph below.
          a.Privacy Screen Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Privacy Screen Height: 58 inches (1473 mm).
          c.Privacy Screen Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          6.Shower and Dressing Compartments:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph below.
          a.Panel Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Panel Height: 58 inches (1473 mm).
          c.Panel Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          7.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          a.Standard Shower: 32 inches wide by 32 inches deep by 82 inches high (813 mm wide by 813 mm deep by 2083 mm high).
          b.Standard Shower: 36 inches wide by 36 inches deep by 82 inches high (914 mm wide by 914 mm deep by 2083 mm high).
          c.Neo-Corner Shower: Right triangle with two sides at 40 inches by 82 inches high (1016 mm by 2083 mm high).
          d.Handicapped Shower: 40 inches wide by 40 inches deep by 82 inches high (1016 mm wide by 1016 mm deep by 2083 mm high).
          e.Handicapped Shower: 40 inches wide by 48 inches deep by 82 inches high (1016 mm wide by 1219 mm deep by 2083 mm deep).
 
          I.Factory Finishing:
          1.Clean, degrease, and neutralize panels.
          2.Finish coat: Polyester enamel applied with hot air electrostatic system and baked at 400 degrees F. Finish shall not crack, peel, or deteriorate when tested under the following conditions:
          a.1,000 hours with 100 percent humidity at 100 degree F.
          b.300 hours of 20 percent salt spray at 100 degrees F.
          c.1,000 hours of water soak at 110 degrees F.
          d.Minimum hardness: 2H.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. For multiple colors, list color for each component on Schedule at the end of this Section or on Drawings.
          3.Color: As selected by Architect from manufacturer's standard colors.
          4.Color: As selected by Architect from manufacturer's full range.
          5.Color: Custom color.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs with paragraph selected above. Insert number of colors in second paragraph, if retained.
          a.Single color.
          b.Maximum of ________colors.
 
          2.3STAINLESS STEEL UNITS
          ** NOTE TO SPECIFIER ** Delete product types not required.
 
          A.Toilet Partitions:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Supported: Panels supported by pilasters anchored to floor; General Partitions Manuf. Co. Series 30.
          2.Floor Supported with Headrail: Panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Series 40.
          3.Ceiling Hung: Panels supported by ceiling hung pilasters; General Partitions Manuf. Co. Series 50.
          4.Floor to Ceiling: Panels supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Series 60.
          5.Extra Height Floor to Ceiling: Extra height panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Eastern Panels.
 
          B.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Braced: Screens attached to wall and braced by pilasters anchored to floor; General Partitions Manuf. Co. FBS-3.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-3.
          3.Wall Hung Screen: Screens hung from wall with brackets; General Partitions Manuf. Co. WHS-3.
          4.Wall Hung Flange: Screens hung from wall with continuous aluminum channel; General Partitions Manuf. Co. WHF-3.
          5.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling Model.
 
          C.Privacy Screens:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Screens can be placed between urinals or used to block view at toilet room entrance. Model FBS-1 - Floor Braced Screen, Model FSH-1 - Floor Supported with Headrail, and Floor to Ceiling Model are recommended for privacy screens at locations other than between urinals.
          1.Floor Braced: Screens supported by pilasters anchored to floor; General Partitions Manuf. Co. FBS-3.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-3.
          3.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling.
 
          D.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Shower Cabinets can be installed as single units or as multiple units.
          1.Standard Design: Three-sided rectangular shape with a curb at opening; General Partitions Manuf. Co. Standard.
          2.Triangular Design: Two-sided triangular shape for corner installation with a curb at opening; General Partitions Manuf. Co. Neo-Corner.
          3.Handicapped Design: Rectangular shape with a ramped design to accommodate persons with physical handicaps; General Partitions Manuf. Co. Handicapped.
 
          E.Double-Wall Shower:
          1.Double-wall Ribcore insulation with pre-cast terrazzo receptor.
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          2.Standard Design: 32 inches by 32 inches by 82 inches (813 mm by 813 mm by 2083 mm).
          3.Standard Design: 36 inches by 36 inches by 82 inches (914 mm by 914 mm by 2083 mm).
          4.Standard Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          5.Triangular Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          6.Handicapped Design: 40 inches by 48 inches by 82 inches (1016 mm by 1219 mm by 2083 mm).
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no shower and dressing compartments. Different configurations and sizes of shower and dressing compartments are available.
 
          F.Shower and Dressing Compartments: Combination Shower and Dressing Compartments: Formed from partitions supported by pilasters anchored to floor and braced overhead with headrails to configuration and sizes indicated on Drawings.
 
          G.Panels:
          1.Material: Fabricate from two stainless steel face sheets pressure bonded to honeycomb core.
          2.Face Sheets: ASTM A167, No. 3 directional polished stainless steel. Minimum thickness as follows:
          a.Partition, Door, Urinal Screen, Privacy Screen, and Shower Panels: 22 gage.
          b.Pilaster panels: 22 gage; 20 for ceiling hung.
          3.Core: Sound deadening, moisture resistant, impregnated cardboard honeycomb. Adhere each cell to face sheets with moisture impervious adhesive.
          4.Edges: After assembling face sheets together, attach die drawn, stainless steel, radiused, smooth molding to all four panel sides.
          5.Corner Reinforcement: At each panel corner, mechanically fuse formed steel corner reinforcement to panel edges.
          ** NOTE TO SPECIFIER ** Retain the following paragraph for Series 30 - Floor Supported and Model FBS-3 - Floor Supported Urinal Screen.
          6.Equip bottom end of pilasters with steel bar saddle for attachment to floor with threaded steel studs and leveling nuts.
          ** NOTE TO SPECIFIER ** Retain the following paragraph for Series 50 - Ceiling Hung.
          7.Equip top end of pilasters with steel bar saddle for attachment to ceiling support member with threaded steel studs and leveling nuts.
 
          H.Dimensions:
          1.Toilet Compartment Panel Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. Eastern panels are mounted 3 inches (76 mm) above the floor providing greater privacy.
          a.Panel Height, Standard: 58 inches (1473 mm).
          b.Panel Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Retain one of the following eight paragraphs.
          c.Panel Width: 48 inches (1219 mm).
          d.Panel Width: 54 inches (1372 mm).
          e.Panel Width: 57 inches (1448 mm).
          f.Panel Width: 60 inches (1524 mm).
          g.Panel Width: 61-1/4 inches (1556 mm).
          h.Panel Width: 66 inches (1676 mm).
          i.Panel Width: 72 inches (1829 mm).
          j.Panel Width: 78 inches(1981 mm).
          k.Panel Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          l.As indicated on Drawings.
          2.Door Size:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          a.Inswinging Door Height, Standard: 58 inches (1473 mm).
          b.Inswinging Door Height, Eastern: 67 inches (1702 mm).
          c.Inswinging Door Width: 24 inches (610 mm).
          d.Outswinging Door Width: 32 inches (813 mm) clear opening.
          e.Door Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          f.As indicated on Drawings.
          3.Pilaster Size:
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30, Series 50 and Series 60 partitions.
          a.Pilaster Width: 8 inches (203 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying FSH-3 urinal and privacy screens.
          b.Pilaster Width: To suit compartment size.
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 partitions and FBS-3 screens.
          c.Pilaster Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 40 partitions and Shower and Dressing Compartments.
          d.Pilaster Height: 82 inches (2083 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 50 and Series 60 partitions, and Floor to Ceiling urinal and privacy screens.
          e.Pilaster Height: Extends from floor to ceiling. Refer to Drawings.
          f.Pilaster Thickness: 1-1/4 inches (32 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          g.As indicated on Drawings.
          4.Urinal Screens:
          ** NOTE TO SPECIFIER ** Retain two of the following four paragraphs for urinal screens. Standard height for WHS-3 and WHF-3 urinal screens is 42 inches (1067 mm) and for FBS-3, FSH-3, and Floor to Ceiling urinal screens is 58 inches (1473 mm).
          a.Urinal Screen Width: 18 inches (457 mm).
          b.Urinal Screen Width: 24 inches (610 mm).
          c.Urinal Screen Height: 42 inches (1067 mm).
          d.Urinal Screen Height: 58 inches (1473 mm).
          5.Privacy Screens:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph below.
          a.Privacy Screen Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Privacy Screen Height: 58 inches (1473 mm).
          c.Privacy Screen Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          6.Shower and Dressing Compartments:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph below.
          a.Panel Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Panel Height: 58 inches (1473 mm).
          c.Panel Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          7.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          a.Standard Shower: 32 inches wide by 32 inches deep by 82 inches high (813 mm wide by 813 mm deep by 2083 mm high).
          b.Standard Shower: 36 inches wide by 36 inches deep by 82 inches high (914 mm wide by 914 mm deep by 2083 mm high).
          c.Neo-Corner Shower: Right triangle with two sides at 40 inches by 82 inches high (1016 mm by 2083 mm high).
          d.Handicapped Shower: 40 inches wide by 40 inches deep by 82 inches high (1016 mm wide by 1016 mm deep by 2083 mm high).
          e.Handicapped Shower: 40 inches wide by 48 inches deep by 82 inches high (1016 mm wide by 1219 mm deep by 2083 mm deep).
 
          I.Factory Finishing:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs for exposed stainless steel.
          1.Satin: All exposed stainless steel components shall have a polished satin finish.
          2.Textured: Exposed flat surfaces of panels and pilasters shall have textured leather grain like stainless steel finish. Stainless steel pilaster shoes and other trim shall have No. 4 stainless steel finish.
          ** NOTE TO SPECIFIER ** Delete two paragraphs above and retain paragraph below if stainless steel panels are to be finished with baked enamel.
          3.Baked Enamel: Clean, degrease, and neutralize panels. Apply polyester enamel with hot air electrostatic system and baked at 400 degrees F. Finish shall not crack, peel, or deteriorate when tested under the following conditions:
          a.1,000 hours with 100 percent humidity at 100 degree F.
          b.300 hours of 20 percent salt spray at 100 degrees F.
          c.1,000 hours of water soak at 110 degrees F.
          d.Minimum hardness: 2H.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. For multiple colors, list color for each component on Schedule at the end of this Section or on Drawings.
          4.Color: As selected by Architect from manufacturer's standard colors.
          5.Color: As selected by Architect from manufacturer's full range.
          6.Color: Custom color.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs with paragraph selected above. Insert number of colors in second paragraph, if retained.
          a.Single color.
          b.Maximum of ________colors.
 
          2.4PLASTIC LAMINATE PARTITIONS AND SCREENS
          ** NOTE TO SPECIFIER ** Delete product types not required.
 
          A.Toilet Partitions:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Supported: Panels supported by pilasters anchored to floor; General Partitions Manuf. Co. Series 30.
          2.Floor Supported with Headrail: Panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Series 40.
          3.Ceiling Hung: Panels supported by ceiling hung pilasters; General Partitions Manuf. Co. Series 50.
          4.Floor to Ceiling: Panels supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Series 60.
          5.Extra Height Floor to Ceiling: Extra height panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Eastern Panels.
 
          B.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Braced: Screens attached to wall and braced by pilasters anchored to floor; General Partitions Manuf. Co. FBS-4.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-4.
          3.Wall Hung Screen: Screens hung from wall with brackets; General Partitions Manuf. Co. WHS-4.
          4.Wall Hung Flange: Screens hung from wall with continuous aluminum channel; General Partitions Manuf. Co. WHF-4.
          5.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling Model.
 
          C.Privacy Screens:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Screens can be placed between urinals or used to block view at toilet room entrance. Model FBS-4 - Floor Braced Screen, Model FSH-4 - Floor Supported with Headrail, and Floor to Ceiling Model are recommended for privacy screens at locations other than between urinals.
          1.Floor Braced: Screens supported by pilasters anchored to floor; General Partitions Manuf. Co. FBS-4.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-4.
          3.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling.
 
          D.Panels:
          1.Material: Doors, panels, screens, and pilasters shall be manufactured from plastic laminate face sheets and edging, bonded with adhesive to core.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Standard core for plastic laminate faced panels is particle board. For locker rooms and other areas with high humidity, a plywood core is recommended for plastic laminate faced panels. Neither particle board or plywood should be used for shower cabinets and compartments. For shower panels, solid phenolic panels with melamine finish matching plastic laminate used for toilet compartments should be considered.
          a.Core: ANSI 208.1, Medium Density Series, wood particle board with 45 pounds minimum density.
          b.Core: Exterior grade plywood with waterproof glue.
          2.Face Sheets and Edges: Manufacture from NEMA LD-3, General Purpose Type plastic laminate, 1/16 inch (1.58 mm) thick.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs.
          3.Color: As selected by Architect from manufacturer's standard colors.
          4.Color: As selected by Architect from manufacturer's full range.
          5.Color: Custom color.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs with paragraph selected above. Insert number of colors in second paragraph, if retained.
          a.Single color.
          b.Maximum of ________colors.
 
          E.Dimensions:
          1.Toilet Compartment Panel Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. Eastern panels are mounted 3 inches (76 mm) above the floor providing greater privacy.
          a.Panel Height, Standard: 58 inches (1473 mm).
          b.Panel Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Retain one of the following eight paragraphs.
          c.Panel Width: 48 inches (1219 mm).
          d.Panel Width: 54 inches (1372 mm).
          e.Panel Width: 57 inches (1448 mm).
          f.Panel Width: 60 inches (1524 mm).
          g.Panel Width: 61-1/4 inches (1556 mm).
          h.Panel Width: 66 inches (1676 mm).
          i.Panel Width: 72 inches (1829 mm).
          j.Panel Width: 78 inches (1981 mm).
          k.Panel Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          l.As indicated on Drawings.
          2.Door Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a.Inswinging Door Height, Standard: 58 inches (1473 mm).
          b.Inswinging Door Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          c.Inswinging Door Width: 24 inches (610 mm).
          d.Outswinging Door Width: 32 inches (813 mm) clear opening.
          e.Door Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          f.As indicated on Drawings.
          3.Pilaster Size:
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 and Series 50 partitions.
          a.Pilaster Width: 8 inches (203 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying FSH-4 urinal and privacy screens.
          b.Pilaster Width: To suit compartment size.
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 partitions, FBS-4 screens, or FSH-4 urinal and privacy screens.
          c.Pilaster Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 40 partitions or FSH-4 urinal and privacy screens.
          d.Pilaster Height: 82 inches (2083 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 50 and Series 60 partitions, and Floor to Ceiling urinal and privacy screens.
          e.Pilaster Height: Extends from floor to ceiling. Refer to Drawings.
          f.Pilaster Thickness: 1-1/4 inches (32 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          g.As indicated on Drawings.
          4.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a.Urinal Screen Width: 18 inches (457 mm).
          b.Urinal Screen Width: 24 inches (610 mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          c.Urinal Screen Height: 42 inches (1067 mm).
          d.Urinal Screen Height: 58 inches (1473 mm).
          5.Privacy Screens:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph.
          a.Privacy Screen Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Privacy Screen Height: 58 inches (1473 mm).
          c.Privacy Screen Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
 
          2.5SOLID PHENOLIC UNITS
          ** NOTE TO SPECIFIER ** Delete product types not required.
 
          A.Toilet Partitions:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Supported: Panels supported by pilasters anchored to floor; General Partitions Manuf. Co. Series 30.
          2.Floor Supported with Headrail: Panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Series 40.
          3.Ceiling Hung: Panels supported by ceiling hung pilasters; General Partitions Manuf. Co. Series 50.
          4.Floor to Ceiling: Panels supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Series 60.
          5.Extra Height Floor to Ceiling: Extra height panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Eastern Panels.
 
          B.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Braced: Screens attached to wall and braced by pilasters anchored to floor; General Partitions Manuf. Co. FBS-6.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-6.
          3.Wall Hung Screen: Screens hung from wall with brackets; General Partitions Manuf. Co. WHS-6.
          4.Wall Hung Flange: Screens hung from wall with continuous aluminum channel; General Partitions Manuf. Co. WHF-6.
          5.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling Model.
 
          C.Privacy Screens:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Screens can be placed between urinals or used to block view at toilet room entrance. Model FBS-6 - Floor Braced Screen, Model FSH-6 - Floor Supported with Headrail, and Floor to Ceiling Model are recommended for privacy screens at locations other than between urinals.
          1.Floor Braced: Screens supported by pilasters anchored to floor; General Partitions Manuf. Co. FBS-6.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-6.
          3.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling.
 
          D.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs. Shower Cabinets can be installed as single units or as multiple units. Cabinets are provided with precast terrazzo receptors in three designs.
          1.Standard Design: Three-sided rectangular shape with a curb at opening; General Partitions Manuf. Co. Standard.
          2.Triangular Design: Two sided triangular shape for corner installation with a curb at opening; General Partitions Manuf. Co. Neo-corner.
          3.Handicapped Design: Rectangular shape with a ramped design to accommodate persons with physical handicaps; General Partitions Manuf. Co. Handicapped.
 
          E.Double-Wall Shower:
          1.Solid phenolic with pre-cast terrazzo receptor.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          a.Thickness: 1/2 inch (13 mm).
          b.Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          2.Standard Design: 32 inches by 32 inches by 82 inches (813 mm by 813 mm by 2083 mm).
          3.Standard Design: 36 inches by 36 inches by 82 inches (914 mm by 914 mm by 2083 mm).
          4.Standard Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          5.Triangular Design: 40 inches by 40 inches by 82 inches (1016 mm by 1016 mm by 2083 mm).
          6.Handicapped Design: 40 inches by 48 inches by 82 inches (1016 mm by 1219 mm by 2083 mm).
          ** NOTE TO SPECIFIER ** Delete the following paragraph if no shower and dressing compartments. Different configurations and sizes of shower and dressing compartments are available.
 
          F.Shower and Dressing Compartments: Combination Shower and Dressing Compartments: Formed from partitions supported by pilasters anchored to floor and braced overhead with headrails to configuration and sizes indicated on Drawings.
 
          G.Panels:
          1.Material: Solid phenolic core made of multiple layers of phenolic resin impregnated kraft paper compressed under heat and pressure. Face with high pressure melamine sheet fusion welded to surface of core.
          a.Resistant to delamination, water, steam, corrosion, soaps, detergents, and mildew.
          2.Edges: Black solid phenolic resin, radiused and polished.
          3.Fire Hazard: Class B in accordance with ASTM E84 with 35 maximum flame spread and 100 maximum smoke development.
          ** NOTE TO SPECIFIER ** Delete two of the following three paragraphs.
          4.Color: As selected by Architect from manufacturer's standard colors.
          5.Color: As selected by Architect from manufacturer's full range.
          6.Color: Custom color.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs with paragraph selected above. Insert number of colors in second paragraph, if retained.
          a.Single color.
          b.Maximum of ________colors.
 
          H.Dimensions:
          1.Panel Size:
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. Eastern panels are mounted 3 inches (76 mm) above the floor providing greater privacy.
          a.Panel Height, Standard: 58 inches (1473 mm).
          b.Panel Height, Eastern: 67 inches (1702 mm).
          ** NOTE TO SPECIFIER ** Retain one of the following eight paragraphs.
          c.Panel Width: 48 inches (1219 mm).
          d.Panel Width: 54 inches (1372 mm).
          e.Panel Width: 57 inches (1448 mm).
          f.Panel Width: 60 inches (1524 mm).
          g.Panel Width: 61-1/4 inches (1556 mm).
          h.Panel Width: 66 inches (1676 mm).
          i.Panel Width: 72 inches (1829 mm).
          j.Panel Width: 78 inches(1981 mm).
          k.Panel Thickness: 1/2 inch (13 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          l.As indicated on Drawings.
          2.Door Size:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs. Eastern panels are only available for Series 30, Series 40, and Series 60 partitions. In order to avoid potential conflicts do not list sizes in both Drawings and Specifications.
          a.Inswinging Door Height, Standard: 58 inches (1473 mm).
          b.Inswinging Door Height, Eastern: 67 inches (1702 mm).
          c.Inswinging Door Width: 24 inches (610 mm).
          d.Outswinging Door Width: 32 inches (813 mm) clear opening.
          e.Door Thickness: 3/4 inch (19 mm).
          f.As indicated on Drawings.
          3.Pilaster Size:
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 and Series 50 partitions.
          a.Pilaster Width: 8 inches (203 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 30 partitions and FBS-6 screens.
          b.Pilaster Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 40 partitions and Shower and Dressing Compartments.
          c.Pilaster Height: 82 inches (2083 mm).
          ** NOTE TO SPECIFIER ** Retain the following paragraph if specifying Series 50 and Series 60 partitions, and Floor to Ceiling urinal and privacy screens.
          d.Pilaster Height: Varies with ceiling height. Refer to Drawings.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs. Pilasters for Series 40 and Series 60 are 3/4 inch (19 mm) thick with 1 inch (25 mm) as an optional thickness. Series 30 and Series 50 are only available with 1 inch (25 mm) thickness.
          e.Pilaster Thickness: 3/4 inch (19 mm).
          f.Pilaster Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          g.As indicated on Drawings.
          4.Urinal Screens:
          ** NOTE TO SPECIFIER ** Retain two of the following four paragraphs for urinal screens. Standard height for WHS-6 and WHF-6 urinal screens is 42 inches (1067 mm) and for FBS-6, FSH-6, and Floor to Ceiling urinal screens is 58 inches (1473 mm).
          a.Urinal Screen Width: 18 inches (457 mm).
          b.Urinal Screen Width: 24 inches (610 mm).
          c.Urinal Screen Height: 42 inches (1067 mm).
          d.Urinal Screen Height: 58 inches (1473 mm).
          5.Privacy Screens:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph.
          a.Privacy Screen Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Privacy Screen Height: 58 inches (1473 mm).
          c.Privacy Screen Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          6.Shower and Dressing Compartments:
          ** NOTE TO SPECIFIER ** Insert width in first paragraph below.
          a.Panel Width: _______inches (_____ mm).
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs.
          b.Panel Height: 58 inches (1473 mm).
          c.Panel Height: 70 inches (1778 mm).
          ** NOTE TO SPECIFIER ** Specifier may delete all previous paragraphs and indicate dimensions on Drawings.
          d.As indicated on Drawings.
          7.Shower Cabinets:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          a.Standard Shower: 32 inches wide by 32 inches deep by 82 inches high (813 mm wide by 813 mm deep by 2083 mm high).
          b.Standard Shower: 36 inches wide by 36 inches deep by 82 inches high (914 mm wide by 914 mm deep by 2083 mm high).
          c.Neo-Corner Shower: Right triangle with two sides at 40 inches by 82 inches high (1016 mm by 2083 mm high).
          d.Handicapped Shower: 40 inches wide by 40 inches deep by 82 inches high (1016 mm wide by 1016 mm deep by 2083 mm high).
          e.Handicapped Shower: 40 inches wide by 48 inches deep by 82 inches high (1016 mm wide by 1219 mm deep by 2083 mm deep).
 
          2.6HIGH DENSITY POLYMER UNITS
          ** NOTE TO SPECIFIER ** Delete product types not required.
 
          A.Toilet Partitions:
          ** NOTE TO SPECIFIER ** Retain one of the following four paragraphs and delete units not required.
          1.Floor Supported with Headrail: Panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Series 40.
          2.Ceiling Hung: Panels supported by ceiling hung pilasters; General Partitions Manuf. Co. Series 50.
          3.Floor to Ceiling: Panels supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Series 60.
          4.Extra Height Floor to Ceiling: Extra height panels supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. Eastern Panels.
 
          B.Urinal Screens:
          ** NOTE TO SPECIFIER ** Delete four of the following five paragraphs.
          1.Floor Braced: Screens attached to wall and braced by pilasters anchored to floor; General Partitions Manuf. Co. FBS-7.
          2.Floor Supported with Headrail: Screens supported by pilasters anchored to floor and braced overhead with headrail; General Partitions Manuf. Co. FSH-7.
          3.Wall Hung Screen: Screens hung from wall with brackets; General Partitions Manuf. Co. WHS-7.
          4.Wall Hung Flange: Screens hung from wall with continuous aluminum channel; General Partitions Manuf. Co. WHF-7.
          5.Floor to Ceiling: Screens supported by pilasters anchored to floor and extending to ceiling; General Partitions Manuf. Co. Floor to Ceiling Model.