MasterFormat: 95
Download this Parking Control Equipment Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Magnetic Automation Corp Parking Control Equipment
 
         
SECTION 11150
 
         
PARKING CONTROL EQUIPMENT
 
         
 
         
Copyright 2011 - 2012 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Magnetic Automation Corp; Parking control equipment products.
.
This section is based on the products of Magnetic Automation Corp, which is located at:
3160 Murrell Rd.
Rockledge, FL 32955
Tel: 321-635-8585
Fax: 321-635-9449
Email: request info
Web: www.ac-magnetic.com/usa
[ Click Here ] for additional information.
Welcome to Magnetic Automation Corp, a premier solutions provider for parking and entrance control applications across the globe.
Our product performance is unsurpassed and our design flexibility picks up where others leave off. We have been going strong for over 60 years and we continue to expand with a sound financial backing.
Our dealer/distributor and system integration partners are some of the top names in their respective industries. Magnetic's products, which include vehicle barrier gate operators, turnstiles, pedestrian barriers, parking control hardware and other related equipment are used in high profile, high throughput locations around the world. Examples include Government sites, toll roads, airports, seaports, rental car facilities, mass transit sites and other related applications.
Furthermore, besides providing the best products possible, we take great pride in our customer service and doing the old fashioned way; we earn it.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Toll Vehicle Gates.
 
          B.Parking Gates.
 
          C.Access Gates.
 
          D.Wide Lane Vehicle Gates.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 02315 - Excavation and Backfill.
 
          B.Section 02630 - Storm Drainage.
 
          C.Section 02700 - Paving and Accessories.
 
          D.Section 02820 - Fencing
 
          E.Section 03300 - Cast-In-Place Concrete.
 
          F.Section 13700 Security Access Systems.
 
          G.Section 16155 - Electrical Service Wiring
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.ANSI/UL 325 - Door, Drapery, Gate, Louver, and Window Operators and Systems.
 
          B.CAN/CSA-C22.2 No. 247-1992 - Operators and Systems of Doors, Gates, Draperies and Louvres.
 
          1.4DESIGN / PERFORMANCE REQUIREMENTS
 
          A.Gates conform to the following UL Classifications.
          1.Meets ANSI/UL 325, UL Category FDDR - Door, Drapery, Gate, Louver and Window Operators and Systems Certified.
          2.Meets CAN/CSA-C22.2 No. 247-1992, UL Category FDDR7 - Door, Drapery, Gate, Louver and Window Operators and Systems (Certified for Canada).
          3.Boom fixture designed to withstand winds of up to a maximum of force 10 on the Beaufort scale (10.44 Lb/sqft;500 N/m2).
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01300.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Operation, installation, and maintenance manuals including wiring diagrams.
 
          C.Shop Drawings: Submit shop drawings showing layout, profiles, and product components, including anchorage, edge conditions, and accessories. Include risers, layouts, and special wiring diagrams.
 
          D.Manufacturer's Certificates: Certify products meet or exceed specified requirements.
 
          E.Closeout Submittals: Provide manufacturer's maintenance instructions that include recommendations for periodic checking and periodic cleaning and maintenance of all components.
 
          1.6QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: Manufacturer with minimum of 5 years experience systems specified.
 
          B.Installer Qualifications: Factory authorized Installer specifically trained in gate operation systems of the type found within this section with documented maintenance and repair service availability for emergency conditions.
 
          C.Provide quarterly maintenance for one year following Substantial Completion of the Project.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          D.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
          3.Refinish mock-up area as required to produce acceptable work.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Store products in manufacturer's unopened packaging with labels intact until ready for installation.
 
          B.Schedule delivery of parking control equipment so that spaces are sufficiently complete that operators can be installed upon delivery.
 
          1.8SEQUENCING
 
          A.Ensure that locating templates and other information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.
 
          B.Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.
 
          1.9PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          1.10WARRANTY
 
          A.Manufacturer's standard two years or 2 million cycles warranty for vehicle gates.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Magnetic Automation Corp, which is located at: 3160 Murrell Rd. ; Rockledge, FL 32955 ; Tel: 321-635-8585; Fax: 321-635-9449 ; Email: request info; Web: www.ac-magnetic.com/usa
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01600.
          ** NOTE TO SPECIFIER ** Select the Gate(s) required from the following paragraphs and delete those not required. If multiple gates are required indicate the quantity and configuration on the Drawings and/or the Schedule at the end of this section.
 
          2.2TOLL GATES
 
          A.Toll High Speed Barrier Gate:
          1.Maximum Arm Length 10 Feet.
          2.0.5 or 0.7 or 1.0 Seconds Open / Close Time.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.8 foot octagonal MicroBoom arm with slide in foam on bottom.
          b.10 foot round MicroBoom arm.
          c.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 43.89 inches (1115 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed.
          a.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          b.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          c.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          d.Most I/O parameters are adjustable.
          e.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          f.5 slots for plug in modules.
          g.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          1)Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          b.Safety loop.
          1)Current consumption: 50 mA
          2)Number of loop detectors: 2
          3)Inductance range: 70 to 500 µH
          4)Number of induction loop sensitivity levels: 10
          5)Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and high cycles between failures of greater than 2,000,000 cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations.
          e.Up/Down/Normal Switch.
          f.Convenience Receptacle.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector .
          b.Wood arm flange adaptor (wood boom supplied by customer).
          c.Contact for release of barrier arm.
          d.Additional heater for extremely cold environments.
          e.Ethernet module that allows for complete gate status, control query
          f.of can bus protocol and reconfiguration from a remote location.
          g.RS485 module.
          h.Inductive limit switch set.
          i.Key switch permanent open / push momentary closed.
          j.Key switch momentary open / momentary closed.
          k.Mounting plate for customer specific ad-ons.
          l.Service module.
          m.Plug in Radio receiver module 433 MHz.
          n.One, two and four button radio transmitters.
          o.Desk panel for one, two, three or four gates.
          p.30MA very bright LED boom lights.
          q.LED boom light blink module.
          r.Red and green strip light that change color with boom position.
          s.Hood mount Xenon flashing orange light.
          t.Hood mount LED flashing orange light.
          u.Hood mount permanent on red light (configurable lead time).
          v.Mast or pole mounting kit for traffic lights or AVI readers.
 
          B.Toll Pro High Speed Barrier Gate:
          1.Maximum Arm Length 10 Feet.
          2.0.9 or 1.3 or 1.8 Seconds Open / Close Time.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.8 foot octagonal MicroBoom arm with slide in foam on bottom.
          b.10 foot round MicroBoom arm.
          c.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 43.89 inches (1115 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Round boom swing away flange.
          b.Octagon Flange.
          c.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed.
          a.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          b.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          c.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          d.Most I/O parameters are adjustable.
          e.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          f.5 slots for plug in modules.
          g.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and high cycles between failures of greater than 2,000,000 cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations. Input and output parameters can be easily changed.
          e.IP 54 rated enclosure.
          f.Convenience Receptacle.
          g.Control electronics can be reached from the top.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector .
          b.Wood arm flange adaptor (wood boom supplied by customer).
          c.Contact for release of barrier arm.
          d.Additional heater for extremely cold environments.
          e.Ethernet module that allows for complete gate status, control query
          f.of can bus protocol and reconfiguration from a remote location.
          g.RS485 module.
          h.Inductive limit switch set.
          i.Key switch permanent open / push momentary closed.
          j.Key switch momentary open / momentary closed.
          k.Mounting plate for customer specific ad-ons.
          l.Service module.
          m.Plug in Radio receiver module 433 MHz.
          n.One, two and four button radio transmitters.
          o.Desk panel for one, two, three or four gates.
          p.30MA very bright LED boom lights.
          q.LED boom light blink module.
          r.Red and green strip light that change color with boom position.
          s.Hood mount Xenon flashing orange light.
          t.Hood mount LED flashing orange light.
          u.Hood mount permanent on red light (configurable lead time).
          v.Mast or pole mounting kit for traffic lights or AVI readers.
 
          C.Toll Barrier Gate:
          1.Maximum Arm Length 10 Feet.
          2.1.3 or 1.9 or 2.6 Seconds Open / Close Time.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.8 foot octagonal MicroBoom arm with slide in foam on bottom.
          b.10 foot round MicroBoom arm.
          c.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 43.89 inches (1115 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Round boom swing away flange.
          b.Octagon Flange.
          c.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed.
          a.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          b.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          c.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          d.Most I/O parameters are adjustable.
          e.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          f.5 slots for plug in modules.
          g.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and tested to ten million cycles. MTBF ten million cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations. Input and output parameters can be easily changed.
          e.IP 54 rated enclosure.
          f.Convenience Receptacle.
          g.Control electronics can be reached from the top.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector .
          b.Wood arm flange adaptor (wood boom supplied by customer).
          c.Contact for release of barrier arm.
          d.Additional heater for extremely cold environments.
          e.Ethernet module that allows for complete gate status, control query
          f.of can bus protocol and reconfiguration from a remote location.
          g.RS485 module.
          h.Inductive limit switch set.
          i.Key switch permanent open / push momentary closed.
          j.Key switch momentary open / momentary closed.
          k.Mounting plate for customer specific ad-ons.
          l.Service module.
          m.Plug in Radio receiver module 433 MHz.
          n.One, two and four button radio transmitters.
          o.Desk panel for one, two, three or four gates.
          p.30MA very bright LED boom lights.
          q.LED boom light blink module.
          r.Red and green strip light that change color with boom position.
          s.Hood mount Xenon flashing orange light.
          t.Hood mount LED flashing orange light.
          u.Hood mount permanent on red light (configurable lead time).
          v.Mast or pole mounting kit for traffic lights or AVI readers.
 
          2.3PARKING GATES
 
          A.Parking Barrier Gate:
          1.Maximum Arm Length 12 Feet.
          2.Open Time 1.8 or 2.3 or 3.5 seconds adjustable / Close Time.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed.
          a.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          b.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          c.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          d.Most I/O parameters are adjustable.
          e.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          f.5 slots for plug in modules.
          g.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations. Input and output parameters can be easily changed.
          e.IP 54 rated enclosure.
          f.Convenience Receptacle.
          g.Control electronics can be reached from the top.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector .
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Inductive limit switch set.
          e.Key switch permanent open / push momentary closed.
          f.Key switch momentary open / momentary closed.
          g.Mounting plate for customer specific ad-ons.
          h.Service module.
          i.Plug in Radio receiver module 433 MHz.
          j.One, two and four button radio transmitters.
          k.Desk panel for one, two, three or four gates.
          l.30MA very bright LED boom lights.
          m.LED boom light blink module.
          n.Red and green strip light that change color with boom position.
          o.Hood mount Xenon flashing orange light.
          p.Hood mount LED flashing orange light.
          q.Hood mount permanent on red light (configurable lead time).
          r.Mast or pole mounting kit for traffic lights or AVI readers.
          s.Support pillar.
          t.Support pillar with electro-mechanical arm lock and control unit.
 
          B.Parking Pro Barrier Gate:
          1.Maximum Arm Length 12 Feet.
          2.Open Time 1.8 or 2.3 or 3.5 seconds adjustable / Close Time.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*)
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Similar to RAL 9006 Light Gray. (RC0**2*)
          k.Color: Similar to RAL 9007 Dark Gray. (RC0**1*)
          l.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display. All inputs and out puts can be reconfigured in the field or via Ethernet module.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations. Input and output parameters can be easily changed.
          e.IP 54 rated enclosure.
          f.Convenience Receptacle.
          g.Control electronics can be reached from the top.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector .
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Ethernet module that allows for complete gate status, control query
          e.of can bus protocol and reconfiguration from a remote location
          f.RS485 module
          g.Inductive limit switch set.
          h.Key switch permanent open / push momentary closed.
          i.Key switch momentary open / momentary closed.
          j.Mounting plate for customer specific ad-ons.
          k.Service module.
          l.Plug in Radio receiver module 433 MHz.
          m.One, two and four button radio transmitters.
          n.Desk panel for one, two, three or four gates.
          o.30MA very bright LED boom lights
          p.LED boom light blink module
          q.Red & green strip light that change color with boom position
          r.Hood mount Xenon flashing orange light
          s.Hood mount LED flashing orange light
          t.Hood mount permanent on red light (configurable lead time)
          u.Mast or pole mounting kit for traffic lights or AVI readers.
          v.Support pillar
          w.Support pillar with electro-mechanical arm lock and control unit
          x.Expansion set for boom up to 12 feet. (12 expanded booms need a pendulum support)
          y.pendulum support)
 
          2.4ACCESS GATES
 
          A.Access Barrier Gate:
          1.Maximum Arm Length 12 Feet.
          2.Close Time 2.2, 3 or 4.2 seconds adjustable.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*)
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          b.Direct drive operation with modular construction.
          c.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          d.Programmable controller for common lane configurations. Input and output parameters can be easily changed.
          e.IP 54 rated enclosure.
          f.Convenience Receptacle.
          g.Control electronics can be reached from the top.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector.
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Inductive limit switch set.
          e.Key switch permanent open / push momentary closed.
          f.Key switch momentary open / momentary closed.
          g.Mounting plate for customer specific ad-ons.
          h.Service module.
          i.Plug in Radio receiver module 433 MHz.
          j.One, two and four button radio transmitters.
          k.Desk panel for one, two, three or four gates.
          l.30MA very bright LED boom lights.
          m.LED boom light blink module.
          n.Red & green strip light that change color with boom position.
          o.Hood mount Xenon flashing orange light.
          p.Hood mount LED flashing orange light.
          q.Hood mount permanent on red light (configurable lead time).
          r.Mast or pole mounting kit for traffic lights or AVI readers.
          s.Support pillar.
          t.Support pillar with electro-mechanical arm lock and control unit.
 
          B.Access-L Barrier Gate:
          1.Maximum Arm Length 15 Feet.
          2.Close Time 4.0, 5.5 or 6.7 Seconds adjustable.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.15 foot VarioBoom octagonal with foam on the bottom. (requires pendulum support or support pillar).
          f.15 foot VarioBoom articulating octagonal arm, foam on bottom of boom and forcing lever.
          g.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*)
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Direct drive operation with modular construction.
          b.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          c.Programmable controller for common lane configurations.
          d.Up/Down/Normal Switch
          e.Convenience Receptacle.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector.
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Inductive limit switch set.
          e.Key switch permanent open / push momentary closed.
          f.Key switch momentary open / momentary closed.
          g.Mounting plate for customer specific ad-ons.
          h.Service module.
          i.Plug in Radio receiver module 433 MHz.
          j.One, two and four button radio transmitters.
          k.Desk panel for one, two, three or four gates.
          l.30MA very bright LED boom lights.
          m.LED boom light blink module.
          n.Red & green strip light that change color with boom position.
          o.Hood mount Xenon flashing orange light.
          p.Hood mount LED flashing orange light.
          q.Hood mount permanent on red light (configurable lead time).
          r.Mast or pole mounting kit for traffic lights or AVI readers.
          s.Support pillar.
          t.Support pillar with electro-mechanical arm lock and control unit.
          u.Pendulum support.
 
          C.Access-Pro Barrier Gate:
          1.Maximum Arm Length 12 Feet.
          2.Open/Close Time 1.3 or 1.8 or 2.5 seconds adjustable.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Similar to RAL 9006 Light Gray. (RC0**2*)
          k.Color: Similar to RAL 9007 Dark Gray. (RC0**1*)
          l.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Swing Away Flange.
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC Pro integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display. All inputs and out puts can be reconfigured in the field or via Ethernet module.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable. I/O functions are re-assignable in the field.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Direct drive operation with modular construction.
          b.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          c.Programmable controller for common lane configurations.
          d.IP 54 rated enclosure.
          e.Convenience Receptacle.
          f.Control electronics can be reached from the top .
          g.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector.
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Ethernet module that allows for complete gate status, control query
          e.of can bus protocol and reconfiguration from a remote location
          f.RS485 module Inductive limit switch set.
          g.Key switch permanent open / push momentary closed.
          h.Key switch momentary open / momentary closed.
          i.Mounting plate for customer specific ad-ons.
          j.Service module.
          k.Plug in Radio receiver module 433 MHz.
          l.One, two and four button radio transmitters.
          m.Desk panel for one, two, three or four gates.
          n.30MA very bright LED boom lights.
          o.LED boom light blink module.
          p.Red & green strip light that change color with boom position.
          q.Hood mount Xenon flashing orange light.
          r.Hood mount LED flashing orange light.
          s.Hood mount permanent on red light (configurable lead time).
          t.Mast or pole mounting kit for traffic lights or AVI readers.
          u.Support pillar.
          v.Support pillar with electro-mechanical arm lock and control unit.
          w.Pendulum support.
          x.Expansion set for boom up to 12 feet. (12 expanded booms need a pendulum support)
 
          D.Access-Pro-L Barrier Gate:
          1.Maximum Arm Length 20 Feet.
          2.Open/Close Time 4, 5.5 or 6.7 seconds adjustable.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.15 foot VarioBoom octagonal with foam on the bottom. (requires pendulum support or support pillar).
          f.15 foot VarioBoom articulating octagonal arm, foam on bottom of boom and forcing lever.
          g.20 foot VarioBoom octagonal with foam on the bottom. (requires pendulum support or support pillar).
          h.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Similar to RAL 9006 Light Gray. (RC0**2*)
          k.Color: Similar to RAL 9007 Dark Gray. (RC0**1*)
          l.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Octagonal Breakaway Flange. (only for boom up to 12 feet long)
          c.Octagonal swing away flange. (only for boom up to 12 feet long)
          d.Round swingaway flange. (only for 10 foot round boom)
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC Pro integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display. All inputs and out puts can be reconfigured in the field or via Ethernet module.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable. I/O functions are re-assignable in the field.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Direct drive operation with modular construction.
          b.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          c.Programmable controller for common lane configurations.
          d.IP 54 rated enclosure.
          e.Convenience Receptacle.
          f.Control electronics can be reached from the top .
          g.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector.
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Ethernet module that allows for complete gate status, control query
          e.of can bus protocol and reconfiguration from a remote location
          f.RS485 module Inductive limit switch set.
          g.Key switch permanent open / push momentary closed.
          h.Key switch momentary open / momentary closed.
          i.Mounting plate for customer specific ad-ons.
          j.Service module.
          k.Plug in Radio receiver module 433 MHz.
          l.One, two and four button radio transmitters.
          m.Desk panel for one, two, three or four gates.
          n.30MA very bright LED boom lights.
          o.LED boom light blink module.
          p.Red & green strip light that change color with boom position.
          q.Hood mount Xenon flashing orange light.
          r.Hood mount LED flashing orange light.
          s.Hood mount permanent on red light (configurable lead time).
          t.Mast or pole mounting kit for traffic lights or AVI readers.
          u.Support pillar.
          v.Support pillar with electro-mechanical arm lock and control unit.
          w.Pendulum support.
          x.Expansion set for boom up to 12 feet. (12 expanded booms need a pendulum support)
 
          E.Access-Pro-H Barrier Gate:
          1.Maximum Arm Length 20 Feet.
          2.Open/Close Time 4, 5.5 or 6.7 seconds adjustable.
          3.Ambient Temperature range minus 30 degrees C to plus 50 degrees C (minus 22 degrees F to 122 degrees F).
          4.Wind force 10 Bft (Beaufort).
          5.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          6.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape labels.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.10 foot VarioBoom octagonal arm with bottom foam.
          b.10 foot VarioBoom ariculating octagonal arm with foam on bottom of boom and forcing lever.
          c.12 foot VarioBoom octagonal arm with bottom foam.
          d.12 foot VarioBoom articulated booms with foam on bottom of boom and forcing lever.
          e.15 foot VarioBoom octagonal with foam on the bottom. (requires pendulum support or support pillar).
          f.15 foot VarioBoom articulating octagonal arm, foam on bottom of boom and forcing lever.
          g.20 foot VarioBoom octagonal with foam on the bottom. (requires pendulum support or support pillar).
          h.Trim to length indicated.
          7.Power Requirement: 85 to 264VAC, 50 or 60 Hz, 400 Watts.
          8.Housing: 36 inches (915 mm) tall, 12.40 inches (315 mm) wide, 14.17 inches (360 mm) deep, height to center of arm 34.44 inches (875 mm).
          a.Aluminum extruded housing frame chromatised and powder coated.
          b.Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service.
          c.Front panel and rear panel are removable without hand tools for maintenance.
          d.Housing fits over the frame to form a weather tight (IP54) enclosure.
          e.Lock is secured with a double cam to secure the hood and the front access panel. Keyway is shuttered to prevent moisture from freezing the lock mechanism.
          f.Stainless steel base frame.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          g.Color: Front and rear access panels similar to RAL7021 (black grey)
          h.Color: Similar to RAL 2000 Orange. (RC0**0*
          i.Color: Similar to RAL 1910 White. (RC0**4*)
          j.Color: Similar to RAL 9006 Light Gray. (RC0**2*)
          k.Color: Similar to RAL 9007 Dark Gray. (RC0**1*)
          l.Color: Custom color as selected by the Architect.
          9.Flange Type:
          ** NOTE TO SPECIFIER ** Select flange required from the following two paragraphs and delete the one not required. Octagon flange is standard. Swing away flange is required for swing away gate.
          a.Octagon Flange.
          b.Octagonal Breakaway Flange. (only for boom up to 12 feet long)
          c.Octagonal swing away flange. (only for boom up to 12 feet long)
          d.Round swingaway flange. (only for 10 foot round boom)
          10.Drive Unit: MHTM Microdrive, 100 percent duty cycle, spring-balanced, brushless, DC servo motor and lever system. Lever system locks the barrier arm in both end positions. In case of power outage, the barrier can easily be moved by hand. Drive system provides a MTBF in excess of 2 million cycles operation. Microdrive with combined motor control and gearing tested for 10 million cycles.
          11.Controller: MGC Pro integrated 24VDC controller with 8 digital inputs, 4 digital outputs, and 6 relay outputs. Controller capable of selectable reduced closing speed. Easy to program lane configurations and operation parameters via push buttons and LCD display. All inputs and out puts can be reconfigured in the field or via Ethernet module.
          a.Plug in module Dual channel vehicle loop detector.
          b.Digital inputs: input voltage 24VDC plus or minus 10 percent; Input current less than 10 mA per input; Max line length without over voltage module 100 feet
          c.Digital Outputs: Open collector; switching voltage 34VDC plus or minus 10 percent; Max. Switching current 100 mA; Max line length without over voltage module is 100 feet.
          d.Output relay: 3 normally open contact (isolated) and 3 change over contacts NO/NC (isolated); Maximum switching voltage 30 VAC/VDC; Switching current 10mA to 1 Amp; life time 5 million cycles minimum (rated at 36,000 cycles per hour)
          e.Most I/O parameters are adjustable. I/O functions are re-assignable in the field.
          f.Graphics Display 128 by 65 pixels. Language display selectable English, Spanish, French, Portuguese, German, Italian
          g.5 slots for plug in modules.
          h.Service mode - allows raising and lowing of gate via integrated push buttons
          12.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Single-beam safety light barrier consists of a transmitter and a receiver. Light barrier is specifically designed for outdoor use with integrated heating, to ensure proper function even under the most adverse of weather conditions.
          c.Safety loop.
          d.Current consumption: 50 mA
          e.Number of loop detectors: 2
          f.Inductance range: 70 to 500 µH
          g.Number of induction loop sensitivity levels: 10
          h.Response sensitivity induction loop selectable: 0.01 to 2.0 percent
          13.Features:
          a.Direct drive operation with modular construction.
          b.Built-in position sensors with no limit switches providing arm position status and self-learning control to optimum braking and eliminate boom arm bouncing, sagging or rotating out of position.
          c.Programmable controller for common lane configurations.
          d.IP 54 rated enclosure.
          e.Convenience Receptacle.
          f.Control electronics can be reached from the top .
          g.Low power consumption and tested to ten million cycles. MTBF greater than 2,000,000 cycles.
          ** NOTE TO SPECIFIER ** Select the optional equipment required from the following paragraphs. Delete equipment not required.
          14.Optional Equipment:
          a.Dual channel vehicle loop detector.
          b.Contact for release of barrier arm.
          c.Additional heater for extremely cold environments.
          d.Ethernet module that allows for complete gate status, control query
          e.of can bus protocol and reconfiguration from a remote location
          f.RS485 module Inductive limit switch set.
          g.Key switch permanent open / push momentary closed.
          h.Key switch momentary open / momentary closed.
          i.Mounting plate for customer specific ad-ons.
          j.Service module.
          k.Plug in Radio receiver module 433 MHz.
          l.One, two and four button radio transmitters.
          m.Desk panel for one, two, three or four gates.
          n.30MA very bright LED boom lights.
          o.LED boom light blink module.
          p.Red & green strip light that change color with boom position.
          q.Hood mount Xenon flashing orange light.
          r.Hood mount LED flashing orange light.
          s.Hood mount permanent on red light (configurable lead time).
          t.Mast or pole mounting kit for traffic lights or AVI readers.
          u.Support pillar.
          v.Support pillar with electro-mechanical arm lock and control unit.
          w.Pendulum support.
          x.Expansion set for boom up to 12 feet. (12 expanded booms need a pendulum support)
 
          2.5WIDE LANE VEHICLE GATES
 
          A.MTS 8 Barrier Gate:
          1.Maximum Arm Length 33 Feet.
          2.8.5 Seconds Open / Close Time.
          3.Arm Location:
          ** NOTE TO SPECIFIER ** Select one of the following two paragraphs and delete the one not required.
          a.Left hand.
          b.Right hand.
          4.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.20 foot octagonal arm.
          b.27 foot octagonal arm.
          c.33 foot octagonal arm.
          d.Trim to length indicated.
          5.Power Requirement: 115V, 60Hz, 250 Watts.
          6.Housing: 14 gauge zinc coated sheet steel on a base frame of stainless steel, with phosphate and powder coat finish. Control units mounted to removable zinc plated sheet steel panel. All components are accessible through maintenance door and removable top cover.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          a.Color: RAL 2000 Orange.
          b.Color: Custom color as selected by the Architect.
          7.Drive Unit: 60 percent duty cycle spring-balanced AC torque motor providing in excess of 1 million cycles operation.
          ** NOTE TO SPECIFIER ** Select one of the following two Controller paragraphs and delete the one not required.
          8.Controller: Magnetic Lane Controller, six potential free digital inputs to open and close barrier and safety device, one pulse output and two transistor outputs for gate position feedback (open/close), warning lights, and traffic light. Dual channel loop detector with two independent relay outputs.
          9.Controller: Magnetic Lane Controller with built-in dual channel vehicle loop detectors, 5 potential free inputs and 2 24V DC outputs, and 2 multifunction form C relay outputs. Programmable lane configurations and operation parameters via selector switch, push buttons and LCD display.
          10.Safety Device: Provide with the following device.
          ** NOTE TO SPECIFIER ** Select safety device required from the following two paragraphs and delete the one not required.
          a.Photoelectric beams.
          b.Safety loop.
          11.Features:
          a.Oversized Octagon Flange
          b.Up/Down/Normal Switch
          c.Convenience Receptacle
          d.Single Limit Switch with Cam for Safety
          12.Optional Equipment:
          a.Single channel vehicle loop detector.
          b.Dual channel vehicle loop detector.
          c.Pendulum support for boom arm lengths over 14 feet.
          d.Boom arm lights with controller.
          e.Additional heater for extremely cold environments.
 
          B.MTS 8W Barrier (Horizontal Swing) Gate:
          1.Maximum Arm Length 33 Feet on Each Side.
          2.40 Seconds for 90 Degree Horizontal Swing.
          3.Gate Arm: Extruded aluminum shop finished with white powder coat with red reflective tape strips.
          ** NOTE TO SPECIFIER ** Delete gate arms not required and refer to maximum arm length restrictions for the barrier chosen.
          a.20 foot octagonal arm.
          b.27 foot octagonal arm.
          c.33 foot octagonal arm.
          d.Trim to length indicated.
          4.Power Requirement: 115V, 60Hz, 580 Watts.
          5.Pyramid Shaped Housing: Steel housing frame hot dip galvanized after fabrication. Housing clad with annealed zinc plated sheet steel that is phosphated and powder coated to prevent corrosion. Provided with one lockable service door to provide access to the power switch, controller, and control wiring for service. All housing panels are removable without hand tools for maintenance. Housing fits over the frame to form a weather tight rain tight enclosure. Access door shall be secured with two cam locks shuttered keyway to prevent moisture from freezing the lock mechanism.
          ** NOTE TO SPECIFIER ** Select required from the following two paragraphs and delete the one not required.
          a.Color: RAL 2000 Orange.
          b.Color: Custom color as selected by the Architect.
          6.Drive Unit: Blockable torque motor for 115 VAC. Motor is maintenance-free and can be blocked in any position without being damaged. In the end positions, the motor remains under voltage at reduced power of approximately 20 W.
          7.Controller for Dead Man Function.
          8.Features:
          a.Two Removable Doors
          b.Convenience Receptacle
          c.Open / Closed Indication
          9.Optional Equipment:
          a.Boom arm lights with controller.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
          ** NOTE TO SPECIFIER ** Include the following paragraph for vehicle barriers and bollards. Delete if not applicable .
 
          B.Verify required drainage and electrical services required are in place as required for the installation.
 
          C.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION
 
          A.Install in accordance with manufacturer's instructions.
 
          B.Mount directly to concrete pad, firmly secured, plumb and level.
 
          C.Set equipment level and secure and in the orientation required.
 
          D.Provide electric service wiring in accordance with Section 16155.
 
          E.Coordinate with interface with security access systems specified in Section 13700.
 
          F.Enclose all splices in easily accessible junction boxes or on terminal boards.
 
          G.Tag and identify all cable runs in all junction boxes.
 
          H.Test system and adjust to assure components and accessories are properly connected and in working order.
 
          3.4PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
 
          3.5MAINTENANCE
 
          A.Maintain at three-month intervals during specified maintenance period, primarily checking rubber end stops on direct drive unit.
 
          3.6SCHEDULES
          ** NOTE TO SPECIFIER ** Retain Paragraph below if required to suit project requirements. Identify products by name on the Drawings or use this paragraph to define the location of each type of material to be used. The following are some examples of schedule references. Edit as required to suit project or delete and identify products on the Drawings.
 
          A.:
 
          B.:
 
         
END OF SECTION