[ Click Here ] for additional information. As a leading designer and manufacturer of residential elevators, luxury home elevators, commercial elevators and lifts for over 30 years, Savaria Lifts has thousands of satisfied customers to thank for their business. Our global operation continuously seeks to advance manufacturing processes in our own modern facilities, allowing us to offer exceptional value and shorter lead times, while never compromising product quality, safety or reliability. As an active member of many trade associations, we are committed to the ongoing support of its customers and dealers alike. Authorized dealers are carefully selected for their knowledge and experience, kept up-to-date with the latest technical and training sessions, and supported with our expert customer service. Residential Elevators: Easily and quickly installed in new or existing homes, our residential elevators will embellish your home decor with its many available stylish finishes. Savaria Infinity Luxury Elevator: Designed to provide a luxurious yet affordable means of vertical transportation for multilevel homes. Infinity's reliable, quiet and smooth operation is ensured by our innovative hydraulic drive system. With a variety of cab finishes and colors the Infinity allows you to customize your design for a more personalized look. Savaria Eclipse Home Elevator: This machine room-less design saves installation space in the home and can also reduce installation time. With an extensive selection in custom finishes, the Eclipse elevator can be designed to suit almost any tastes and preferences. Commercial Elevators: Savaria provides user-friendly, good value solutions for both new construction, and retrofitting into existing buildings. Savaria Orion LU/LA: A fully enclosed commercial elevator that makes code compliance fast and easy. Completely redesigned, it meets all current American and Canadian Code requirements for limited-use/ limited application (LU/LA) elevators. It is also suitable for residential use. Savaria Prolift SCL: A fully enclosed Commercial Lift that provides an economical means of vertical transportation for the physically disabled. It has a reliable, quiet, and smooth operation while serving from two to four floors. Vertical Platform Lifts: Savaria offers a range of lifts for residential and commercial use, from basic to luxurious. These ruggedly constructed lifts have been proven for both indoor and outdoor applications. V1504: The unique drive and platform combinations of the V-1504 vertical wheel chair platform lift allows for rapid delivery and ease of installation in respect to any architectural requirements. Multilift Vertical Platform Lift: The ACME screw drive system offers a safe and reliable operation for its users. This ruggedly constructed lift has been proven for both indoor and outdoor applications. The Multilift vertical wheel chair platform lift is designed to meet today's safety code requirements such as ASME A18.1 for residential use. Incline Platform Lift: The ES-125 stair wheelchair lift is designed for both residential and commercial use. Its compact folding platform leaves the stairway virtually unobstructed when not in use. It can be used both indoors and outdoors. Step Saver Straight Stair Lift: With its smooth rack and pinion drive and battery power, "Step-Saver" can effortlessly take you up and down a straight stairway, even during a power outage. Its neutral color and modern appearance can coordinate with practically any decor, and its slim rail and carriage save room on the steps to allow others access past the lift. Straight Stair Chair: The B.07 straight stair chair can meet a wide variety of accessibility needs. This versatile lift for straight stairways can be built for both indoors or outdoors, residential or commercial use, AC or battery power, with an optional capacity upgrade. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| PART 1 | GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | SECTION INCLUDES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Residential elevators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Commercial wheelchair lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Vertical platform lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Incline platform lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Commercial passenger elevators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | RELATED SECTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Division 16 Sections for standby power source, transfer switch, and connection from auxiliary contacts in transfer switch to controller. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Division 16 Section "Voice and Data Communication Cabling" for telephone service to elevators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Section 03300 - Cast-in-Place Concrete: Concrete for elevator machine foundation, and pit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Section 06100 - Rough Carpentry: Hoistway framing, building-in hoistway door frames and overhead hoist beams. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Section 08210 - Wood Doors: Hoistway doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Section 08710 - Door Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Section 09260 - Gypsum Board Assemblies: Gypsum shaft walls. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Section 09650 - Resilient Flooring: Floor finish in cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Section 09686 - Carpet: Floor finish in cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Section 09900 - Paints and Coatings: Interior transparent wood finish in cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Section 13850 - Detection and Alarm: Fire and smoke detectors and interconnecting devices. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | REFERENCES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | American National Standards Institute (ANSI) B-29.2 - Chain Standards for Inverted Tooth (Silent) Chains and Sprockets. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | American Society of Mechanical Engineers (ASME) A17.1 - Safety Code for Elevators and Escalators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | American Society of Mechanical Engineers (ASME) A18.1 - Safety Standard for Platform and Stairway Chair Lifts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)". | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | REQUIREMENTS OF REGULATORY AGENCIES: | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Fabricate and install work in compliance with applicable jurisdictional authorities. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | File shop drawings and submissions with local authorities as the information is made available. Company pre-inspection and jurisdictional authority inspections and permits are to be made on timely basis as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | SUBMITTALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Submit under provisions of Section 01300. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Product Data: Manufacturer's data sheets on each product to be used, including: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Preparation instructions and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Storage and handling requirements and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Installation methods. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Shop Drawings: Provide a complete layout of lift equipment detailing dimensions and clearances as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Selection Samples: For each finish product specified requiring selection of color or finish, two complete sets of color charts representing manufacturer's full range of available colors and patterns. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | QUALITY ASSURANCE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Installer Qualifications: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Skilled tradesmen shall be employees of the installing contractor approved by the manufacturer, with demonstrated ability to perform the work on a timely basis. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Execute work of this section only by a company that has adequate product liability insurance. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.7 | DELIVERY, STORAGE, AND HANDLING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Store products in manufacturer's unopened packaging until ready for installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.8 | PROJECT CONDITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install systems under environmental conditions outside manufacturer's absolute limits. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.9 | WARRANTY | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Coverage - this warranty applies to the repair or replacement, at Manufacturer's option, of parts that fail due to defective material or workmanship. Manufacturer may, at its option, provide factory reconditioned parts. This warranty is provided to the Authorized Dealer on behalf of the final purchaser of the product and is not transferable. The Manufacturer's warranty does not cover labor charges for the removal, repair or replacement of warranty parts but such costs may be covered for a period of time by Authorized Dealer's warranty, which is provided to purchaser separately. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The manufacturer shall offer a 36-month warranty on parts from date of substantial completion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 2 | PRODUCTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | MANUFACTURERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer: Savaria, which is located at: 107 Alfred Kuehne Blvd. ; Brampton, ON, Canada L6T 4K3; Toll Free Tel: 800-661-5112; Tel: 905-791-5555; Fax: 905-791-2222; Email: request info; Web: www.savaria.com | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Substitutions: Not permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Requests for substitutions will be considered in accordance with provisions of Section 01600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | RESIDENTIAL ELEVATOR | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Residential Elevator: Savaria Telecab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Equipment: Provide equipment, incidental material and labor required for complete, operable hydraulic elevator installation. The elevators shall be erected, installed, adjusted, tested and placed in operation by the elevator system manufacturer or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Performance: The elevator shall be designed and tested in accordance with ASME A17.1 part V. The testing shall consist of loading the platform to rated capacity for several cycles to insure proper operation. Mechanical failures and defects shall be corrected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Accessibility Requirements: Comply with Section 4.10 in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)." | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | The following preparatory work to receive the elevator specified shall be the work provided by others: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Dedicated 110 VAC 20 amp single phase power to operate lift to be provided. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | No pit shall be provided. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide a load-bearing wall to support a load of 700 lbs at any point. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide a floor cut out. Refer to shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | The floor needs to support 3000 lb (1362 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | A phone line shall be provided. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated load: 500 lb (227 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 25 fpm. (0.07 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Car Dimensions: 30 inches W by 46 inches L by 78 inches H (762 mm by 1168 mm by 1981 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 30 inches W by 47 inches L by 78 inches H (762 mm by 1194 mm by 1981 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 32 inches W by 53 inches L by 78 inches H (813 mm by 1346 mm by 1981 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 32 inches W by 54 inches L by 78 inches H (813 mm by 1372 mm by 1981 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Car Access: Manual door. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Car Access: Hydraulic door closer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Car Access: Enter/exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Car Access: Enter/exit front/rear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Travel: ______ feet. Maximum of 23 feet (276 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Operations: Constant pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Power Supply: 110 VAC, 20 amps, 1 Phase. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Drive System: 2 to 1 roller chain hydraulic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Paint: Powder coat finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Color: Almond beige or white. Refer to Room Finish Schedule. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Emergency Power: Battery operation in down direction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Controller: Electronic-free relay logic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Motor/Pump: 110VAC, 1.5HP/screw type. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Car Operating Panel: Constant pressure buttons or rocker switches, emergency stop/alarm button, on/off key switch and emergency light, and an alarm button mounted on a removable steel panel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Hall Call Stations: Provide a surface-mounted Klockner Moeller box for upper and lower levels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Emergency Operation: The car shall be equipped with a battery-operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located in a lockable box at positioned at a designated landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Manual Lowering: Outside the hoistway at bottom landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Walls: Durable metal wall panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Ceilings: Durable metal (standard) with two recessed down lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Overhead lights in the car compartment shall turn ON automatically when the elevator door is opened and to stay on while the elevator is in use. The elevator lights will shut off by a timer when the elevator is not in use. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Floor: Metal with non-skid surface. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Handrail: Handrail located on control panel side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Systems and Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The pumping unit and control shall be enclosed in the hoistway. The controller and pump unit shall be pre-wired and tested prior to shipment. Pump unit shall incorporate the following features: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Smooth stops at each landing shall be an inherent feature. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Adjustable pressure relief valve. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Manually operable down valve to lower lift in the event of an emergency. This valve shall be activated from outside of the hoistway through a keyed box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gate valve to isolate cylinder from pump unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Electrical solenoid for down direction control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Emergency lowering by battery power, from the car control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Roller Chains: Two No.50 roller chains with 5/8 inch (16 mm) pitch. Minimum breaking strength 6100 lb (2772 kg) each. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Leveling Device: The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (13 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | All limit switches and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. The switches shall be located behind the mast wall and be accessible through removable panels. Micro-switches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Guide Yoke: The 2:1 guide yoke/sprocket arrangements shall be supplied with two sprockets, roller guide shoes, bearings and guards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Terminal Stopping Device: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. Limit switches shall be used. Micro-switches are not acceptable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Guide Rail and Brackets: Steel 'C'' guide rails and brackets shall be used to guide the platform and sling. Guide rails shall form part of the structural integrity of the unit and be integral to the mast enclosure, ensuring stability and minimum platform deflection when loaded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireway if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | The door locks shall be fire-rated electric door strike interlocked with operator. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | The door shall be 78 inches H by 30 inches W (1981 mm by 762 mm) and shall be made of steel with Plexiglas insert. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | RESIDENTIAL ELEVATOR | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Residential Elevator: Savaria Infinity. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Equipment: Provide equipment, incidental material and labor required for complete, operable hydraulic elevator installation. The elevators shall be erected, installed, adjusted, tested and placed in operation by the elevator system manufacturer or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Performance: The elevator shall be designed and tested in accordance with ASME A17.1 part V. The testing shall consist of loading the platform to rated capacity for several cycles to insure proper operation. Mechanical failures and defects shall be corrected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Accessibility Requirements: Comply with Section 4.10 in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)." | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | The following preparatory work to receive the elevator specified shall be the work provided by others: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 220 VAC, 30 amp single phase power to operate lift to be provided from a lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. 110 VAC, 15 amp single phase power to operate the lighting circuit. Refer to Drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square hoistway with smooth interior surfaces, including fascias or furring of the hoistway interior. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide rough openings per lift subcontractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide substantial, level pit floor slab as indicated on the lift contractor's shop drawings | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 750 lbs. (340 kg.). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Load: 1000 lbs. (454 kg.). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Rated Speed: 36 fpm (0.18 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 36 inches W by 48 inches D (914 mm by 1219 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 36 inches W by 54 inches D (914 mm by 1372 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 36 inches W by 60 inches D (914 mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Operation: Automatic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Gate Type: Black Scissor Gate. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Gate Type: Horizontally collapsible, accordion style (clear anodized frame, 3 clear acrylic inserts). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Gate Type: Horizontally collapsible, accordion style (bronze frame, 3 bronze acrylic inserts). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Power Supply: 220 Volt, Single Phase, 30 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Power Supply: 208 Volt, 3 Phase, 30 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Travel: ______ feet. * Maximum of 50 feet (600 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Levels Serviced: 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Levels Serviced: 5. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Openings: Enter/exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Openings: Enter/exit front/rear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Openings: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Lighting Supply: 110 Volt, 1 Phase, 60 Cycle, 15 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Jack Type: 1:2 Cable Hydraulic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Pump Type: Submersible with Variable Speed Valve Leveling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Device Type: Magnetic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Car Operating Panel: Automatic push buttons, digital floor position indicator, emergency stop/alarm button, on/off key switch and emergency light, and an alarm button mounted on a removable steel panel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 26. | Hall Call Stations: Provide a keyless hall call station with an illuminated call button and stainless steel cover plate for each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 27. | Emergency Operation: The car shall be equipped with a battery-operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located in a lockable box at positioned at a designated landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 28. | Manual Lowering: Outside the hoistway at machine room. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Walls: MDF (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Walls: Durable Melamine wall panels (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Walls: Finished Raised Hardwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Walls: Clear Finished Recessed Veneer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Walls: Unfinished Veneer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Species: Birch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Ceilings: MDF (Standard) With Four (4) Recessed Down Lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Ceilings: Durable Melamine (Standard) With Four (4) Recessed Down Lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Ceilings: Finished Raised Hardwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Ceilings: Clear Finished Non-Recessed Veneer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Ceilings: Unfinished Veneer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Species: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Species: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Species: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Species: Birch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Overhead lights in the car compartment shall turn ON automatically when the elevator door is opened and to stay on while the elevator is in use. The elevator lights will shut off by a timer when the elevator is not in use. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Floor: Unfinished 3/4 inch (19 mm) plywood sub-flooring (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Floor: Oak. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Floor: Cherry. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Floor: Maple. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Handrail: Brushed Stainless Steel (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Handrail: Anodized Silver (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Handrail: Anodized Bronze (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Handrail: Brass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Systems and Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The pumping unit and control shall be in a separate machine room. The controller and pump unit shall be pre-wired and tested prior to shipment. Pump unit shall incorporate the following features. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Smooth stops at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Submersible pump and motor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Adjustable pressure relief valve. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Manually operable down valve to lower lift in the event of an emergency. This valve shall be activated from outside of the hoistway through a keyed box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Pressure gauge isolating valve, manually operable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Gate valve to isolate cylinder from pump unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Electro Proportional valve for accurate and smooth starts and stops in both directions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| h. | Emergency lowering by battery power, from the car control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Cable: Two 3/8 inch (10 mm) IWRC Galvanized Aircraft Cables. Minimum breaking strength of 14,400 lb (6537 kg) each. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Leveling Device: The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (13 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | All limit switches and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. The switches shall be located behind the mast wall and be accessible through removable panels. Micro-switches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Guide Yoke: The 1:2 guide yoke/sheave arrangement shall be supplied with a sheave, guide shoes and cable guards. The sheave shall be finished with rounded grooves to fit the cables. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Guide Rail and Brackets: Steel 8 lb/ft (11.9 kg/m) "T" guide rails and brackets shall be securely fastened to the building structure. Car sling shall be fabricated from steel members with adequate bracing to support the platform and cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireway if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | The door locks shall be fire-rated electric door strike interlocked with operator. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Car Gate: Horizontally collapsible accordion style car gate with rattan panels and three clear acrylic vision panels. Car gate shall enclose each car entrance. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Emergency Devices: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Terminal limits. Stops the elevator if it overruns the normal limits at the top or bottom landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Final limits. A redundant safety feature if the elevator overruns the terminal limits at the top or bottom, the final limit stops the elevator and renders all automatic controls inoperable. If this happens, the elevator must be serviced to determine and correct the fault. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Pit switch. Disables elevator for servicing purposes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Interlocks. Hoistway doors remain locked when the car is not at that floor and prevent the elevator from running until all doors are closed and locked. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Slack/broken cable safety device. In the unlikely event that drive cable would slacken or break, the device locks the car onto the T-rails, preventing the car from falling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.4 | RESIDENTIAL ELEVATOR | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Residential Elevator: Savaria Eclipse. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Equipment: Provide equipment, incidental material and labor required for complete, operable hydraulic elevator installation. The elevators shall be erected, installed, adjusted, tested and placed in operation by the elevator system manufacturer or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Performance: The elevator shall be designed and tested in accordance with ASME A17.1 part V. The testing shall consist of loading the platform to rated capacity for several cycles to insure proper operation. Mechanical failures and defects shall be corrected. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | The following preparatory work to receive the elevator specified shall be the work provided by others: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 220 VAC, 30 amp single phase power to operate lift to be provided from a lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. 110 VAC, 15 amp single phase power to operate the lighting circuit. Refer to Drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square hoistway with smooth interior surfaces, including fascias or furring of the hoistway interior. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide rough openings per lift subcontractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide substantial, level pit floor slab as indicated on the lift contractor's shop drawings | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 750 lbs. (340 kg.). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Load: 1000 lbs (454 kg) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Rated Speed: 40 fpm (0.20 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 36 inches W by 48 inches D (914 mm by 1219 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 36 inches W by 54 inches D (914 mm by 1371 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 36 inches W by 60 inches D (914 mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Car Dimensions: 40 inches W by 54 inches D (1016 mm by 1371 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Operation: Automatic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Gate Type: Horizontally collapsible, accordion style(clear anodized frame, 3 clear acrylic inserts) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Gate Type: Horizontally collapsible, accordion style (bronze frame, 3 bronze acrylic inserts) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Power Supply: 230 Volt, Single Phase, 60 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Travel: ______ feet. Maximum of 60 feet (720 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Levels Serviced: 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Levels Serviced: 5. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Levels Serviced: 6. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Openings: Enter/exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Openings: Enter/exit front/rear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Openings: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Lighting Supply: 110 Volt, 1 Phase, 60 Cycle, 15 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Geared Roller Chain #60. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Two Way Leveling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Drive: Variable Frequency | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Car Operating Panel: Automatic push buttons, digital floor position indicator, emergency stop/alarm button, on/off key switch and emergency light, and an alarm button mounted on a removable steel panel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 26. | Hall Call Stations: Provide a keyless hall call station with an illuminated call button and a matching cover plate for each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 27. | Emergency Operation: The car shall be equipped with a battery-operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located in a lockable box positioned at the uppermost landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Walls: MDF (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Walls: Durable Melamine wall panels (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Walls: Finished Raised Hardwood (Oak, Cherry, Maple) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Walls: Clear Finished Recessed Veneer (Oak, Cherry, Maple) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Walls: Unfinished Veneer (Oak, Cherry, Maple, Birch) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Ceilings: MDF (Standard) With Four (4) Recessed Down Lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Ceilings: Durable Melamine (Standard) With Four (4) Recessed Down Lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Ceilings: Finished Raised Hardwood (Oak, Cherry, Maple) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Ceilings: Clear Finished Non-Recessed Veneer (Oak, Cherry, Maple) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Ceilings: Unfinished Veneer (Oak, Cherry, Maple, Birch) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Overhead lights in the car compartment shall turn ON automatically when the elevator door is opened and to stay on while the elevator is in use. The elevator lights will shut off by a timer when the elevator is not in use. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Floor: Unfinished 3/4 inch (19 mm) plywood sub-flooring. (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Floor: Oak, Cherry, Maple | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Handrail: Brushed Stainless Steel (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Handrail: Anodized Silver (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Handrail: Anodized Bronze (Standard). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Handrail: Brass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Systems and Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Machine Room-less: Required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The controller shall be pre-wired and tested prior to shipment. It will incorporate the following features. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Smooth stops at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Automatic battery back-up to ensure the lift can travel to lower landings in the event of a power failure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Pre-set overload protection to prevent motor overloading. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | LED display to monitor output current, frequency, voltage, direction, etc. Also used for error message indication. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Drive Chain: Two #60 roller chains. Nominal breaking strength of 9020 lbs. (4091 kg) each. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Leveling Device: The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (13 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | All limit switches and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. The switches shall be located in the hoistway. Micro-switches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Guide Yoke: The 1:2 guide yoke/sheave arrangement shall be supplied with a sheave, guide shoes and cable guards. The sheave shall be finished with rounded grooves to fit the cables. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Guide Rail and Brackets: Steel 6 lb/ft (8.9 kg/m) Modular "T" guide rails and brackets shall be securely fastened to the building structure. Car sling shall be fabricated from steel members with adequate bracing to support the platform and cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireway if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | The door locks shall be fire-rated electric door strike interlocked with operator. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Car Gate: Horizontally collapsible accordion style car gate with rattan panels and three clear acrylic vision panels. Car gate shall enclose each car entrance. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Emergency Devices: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Terminal limits. Stops the elevator if it overruns the normal limits at the top or bottom landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Final limits. A redundant safety feature if the elevator overruns the terminal limits at the top or bottom, the final limit stops the elevator and renders all automatic controls inoperable. If this happens, the elevator must be serviced to determine and correct the fault. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Pit switch. Disables elevator for servicing purposes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Interlocks. Hoistway doors remain locked when the car is not at that floor and prevent the elevator from running until all doors are closed and locked. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Slack/broken safety chain device. In the unlikely event that drive chain would slacken or break, the device locks the car onto the T-rails, preventing the car from falling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.5 | COMMERCIAL WHEELCHAIR LIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Commercial Wheelchair Lifts: Savaria Prolift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Hydraulic Wheelchair Platform Lift: The lift described here, manufactured by Savaria Lifts Inc., is a vertical wheelchair lift consisting of a roped hydraulic tower with a lifting platform. The platform can be customized to better accommodate a wheelchair user or a person with impaired mobility. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Work described in this section includes providing equipment, incidental material and labor required for complete, operable roped hydraulic wheelchair lift installation. Lifts shall be erected, installed, adjusted, tested and placed in operation by lift system manufacturer, or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Lifts shall be in accordance with the ASME A18. 1 and ADA compliant including local codes and regulations except where specified otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | The following preparatory work to receive the lifts specified in this section is part of the work of other sections: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 220 VAC, 50 amp single phase power to operate lift to be provided from a lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. 110 VAC, 15 amp single phase power to operate the lighting circuit. Refer to drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square hoistway with smooth interior surfaces, including fascias or furring of the hoistway interior. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide rough openings per lift subcontractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide substantial, level pit floor slab as indicated on the lift contractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 1000 lb (454 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Load: 1400 lb (635 kg) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Rated Speed: 30 fpm (0.15 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 35 inches W by 48 inches D (889 mm by 1219 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 35 inches W by 54 inches D (889 mm by 1371 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 35 inches W by 60 inches D (889 mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Car Dimensions: 35 inches W by 60 inches D (889 mm by 1524 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Car Dimensions: 42 inches W by 60 inches D (1067 mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Car Dimensions: 47 inches W by 60 inches D (1194 mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Car Dimensions: 35 inches W by 84 inches D (889 mm by 2134 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Levels Serviced: 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Levels Serviced: 5 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Openings: Enter/exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Openings: Enter/exit front/rear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Openings: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Travel: ______ feet. * Maximum of 23 feet (276 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Operations: Constant pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Power Supply: 220 Volt, Single Phase, 50 Amps. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Drive System: 2:1 roped hydraulic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Paint: Powder coat finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Emergency Power: Battery operation in down direction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Controller: Electronic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Motor/Pump: 220VAC, 5HP max. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 26. | Manual Lowering: Outside the hoistway at machine room. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Walls: MDF (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Walls: Steel Walls (Architectural White, Black) (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Walls: Plastic Laminate Panels (Stone Grafix, Fog, Contract Mahogany, Natural Oak) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Ceiling Finish: White egg-crate ceiling with four recessed incandescent down lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Clear anodized aluminum car trim. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Telephone Cabinet (Stainless Steel): Required | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Telephone Cabinet (Stainless Steel): Not Required | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Doors and gates shall be flush mounted inside the hoistway as to avoid pinch points and shear hazards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Handrail: A single handrail, with 1-1/2 inch (38 mm) diameter rail and with both ends returned to the side guard, shall be located on the control wall of the cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Control Panel: Stainless steel control panel with tactile identifications (keyed stations). | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Hoistway Doors: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Landing Doors - Manual: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 1-1/2 hour UL/ULC fire rated assembly. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Flush closing operation with hoistway side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | 35 inches (889 mm) clear opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Concealed electro/mechanical interlock. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Concealed hinges. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Landing Doors - Automatic: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 1-1/2 hour UL/ULC fire rated assembly. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Flush closing operation with hoistway side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | 35 inches (889 mm) clear opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Concealed electro/mechanical interlock. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Concealed hinges. | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Concealed 24 volt door opener with battery back-up. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Car Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Car Operating Panel shall consist of constant pressure buttons, emergency stop/alarm button, on/off key switch and emergency light mounted on a removable stainless steel panel (Type 304 #4 Stainless Steel Finish). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Digital floor indicator in cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Emergency Operation - The car shall be equipped with a battery operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located outside the hoistway in a lockable box positioned at a designated landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Pumping Unit and Control: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The pumping unit and control shall be in a separate machine room. The controller and pump unit shall be pre-wired and tested prior to shipment. Pump unit shall incorporate the following features : | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Smooth stops at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Submersible pump and motor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Adjustable pressure relief valve. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Manually operable down valve to lower lift in the event of an emergency. This valve shall be activated from outside of the hoistway through a keyed box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Pressure gauge isolating valve, manually operable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Gate valve to isolate cylinder from pump unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Electro Proportional valve for accurate and smooth starts and stops in both directions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Emergency lowering by battery power, from the car control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Cylinder And Plunger: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Aircraft Cable: Two, Minimum breaking strength 14,400 lb (6545 kg) each. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Leveling Device: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (12 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | All limit switch and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Guide Yoke: The 2:1 guide yoke assembly shall be supplied with two (2) sheaves, guide shoes, bearings and guards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Call Stations: Provide key-controlled call stations for each landing on a stainless steel plate (Type 304 #4 stainless steel finish). | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Terminal Stopping Devices: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. Micro switches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| P. | Guide Rails: Steel 8 lb per foot guide rails to guide the platform and sling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| Q. | Car Sling: Car sling shall be fabricated from steel with adequate bracing to support the platform and car enclosure. Guide shoes shall be mounted on the top and bottom of the car sling to engage the guide rails. | |||||||||||||||||||||||||||||||||||||||||||||||||
| R. | Wiring: All wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireways if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.6 | HYDRAULIC VERTICAL PLATFORM LIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Hydraulic Vertical Platform Lifts: Savaria V1504-STD. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Hydraulic Vertical Platform Lifts: Savaria V1504-PE: Aluminum Plexiglas Enclosure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Hydraulic Vertical Platform Lift: The lift described here, manufactured by Savaria Lifts Inc., is a vertical platform lift consisting of a hydraulic tower with a lifting platform. The platform can be customized to better accommodate a wheelchair user or a person with impaired mobility. The lift can be used indoor or outdoor (with optional package) and in commercial or residential applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Work described in this section includes providing equipment, incidental material and labor required for complete, operable hydraulic platform lift installation. Lifts shall be erected, installed, adjusted, tested and placed in operation by lift system manufacturer, or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Lifts shall be in accordance with the ASME A18. 1 and ADA compliant including local codes and regulations except where specified otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | The following preparatory work to receive the lifts specified in this section is part of the work of other sections: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 120 VAC, 20 amp single phase power to operate lift to be provided from a lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. Refer to drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square hoistway with smooth interior surfaces, including fascias or furring of the hoistway interior. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide rough openings per lift contractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide substantial, level pit floor slab as indicated on the lift contractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 750 lb (340 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 25 fpm (0.13 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Car Dimensions: 34 inches W by 54 inches D (863 mm by 1371 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 36 inches W by 54 inches D (914 mm by 1371 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Levels Serviced: 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Car Access: Enter/Exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Car Access: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Car Access: Front/rear exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Travel: ______ feet. Maximum of 23 feet (276 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Operations: Constant pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Power Supply: 110 volt, 15 amp, 1 phase, 60 Hz. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Drive System: 2:1 Roller chain hydraulic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Paint: Powder coat finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Emergency Power: Battery operation in down direction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Controller: Electronic-free relay logic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Motor/Pump: 110VAC, 1.5HP. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Manual Lowering: Outside the hoistway at desired landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Color: Almond beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Side guards of platform shall have a steel frame with a powder coat finish and steel panel inserts to a minimum of 42 inches (1067 mm) above the upper landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | No platform gate required, to allow for ease of operation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Upper gate shall be 42 inches high by 36 inches wide (1067 mm by 914 mm), with metal or Plexiglas inserts and shall be equipped with interlock, spring hinges and kick plate. Lower door shall be 80 inches high by 36 inches wide (2032 mm by 914 mm), with metal or Plexiglas inserts and shall be equipped with interlock, hydraulic closer and kick plate on both sides. The inside kick plate shall be made of steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Upper door shall be 36 inches wide by 80 inches high (914 mm by 2032 mm) top landing door instead of the top landing gate. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Lower and upper door and door frame with 1 1/2 hour ULC Fire rating, heavy duty hinges, Door vision panel, flush mounting of door inside the hoistway and adjustable hydraulic door closer on door frame | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | 48 inches (1219 mm) aluminum and acrylic extension at the upper landing with upper door 80 inches high by 34 inches wide (2032 mm by 864 mm), double ventilation system and acrylic dome. The aluminum frames forming the enclosure shall be fully assembled and screwed all together from inside the enclosure for ease of assembling and quick installation time. The enclosure shall be water resistant. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Doors and gates shall be flush mounted inside the hoistway as to avoid pinch points and shear hazards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Handrail: A single handrail, with 1-1/2 inches (38 mm) diameter rail and with both ends returned to the side guard, shall be located on the control wall of the carriage. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Car Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Car Operating Panel shall consist of constant pressure buttons or rocker switches, emergency stop/alarm button, on/off key switch and emergency light mounted on a removable stainless steel panel (Type 304 #4 Stainless Steel Finish). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Emergency Operation - The car shall be equipped with a battery operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located outside the hoistway in a lockable box positioned at a designated landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Pumping Unit and Control: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The pumping unit and control shall be enclosed in the tower. The controller and pump unit shall be pre-wired and tested prior to shipment. The controller is to be electronic-free with relay logic operation for ease of maintenance and service. Pump unit shall incorporate the following features : | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Smooth stops at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Adjustable pressure relief valve. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Manually operable down valve to lower lift in the event of an emergency. This valve shall be activated from outside of the hoistway through a keyed box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Pressure gauge isolating valve, manually operable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Gate valve to isolate cylinder from pump unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Electrical solenoid for down direction control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Emergency lowering by battery power, from the car control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Cylinder And Plunger: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Roller Chains: Two No.50 roller chains with 5/8 inch (16 mm) pitch. Minimum breaking strength 6100 lb (2773 kg) each. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Leveling Device: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (12 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | All limit switch and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. They shall be located behind the mast wall and be accessible through removable panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Guide Yoke: The 2:1 guide yoke/sprocket assembly shall be supplied with two sprockets, roller guide shoes, bearings and guards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Call Stations: Provide key-controlled call stations for upper level and lower level on a stainless steel plate (Type 304 #4 stainless steel finish). | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Terminal Stopping Devices: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. Micro switches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| P. | Guide Rails and Brackets: Steel 'C'' guide rails and brackets shall be used to guide the platform and sling. Guide rails shall form part of the structural integrity of the unit and be integral to the mast enclosure, ensuring stability and minimum platform deflection when loaded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| Q. | Car Sling: Car sling shall be fabricated from steel tubing 44 inches (1116 mm) high with adequate bracing to support the platform and car enclosure. Roller guide shoes shall be mounted on the top and bottom of the car sling to engage the guide rails. Guide shoes shall be roller type with 3 inches (76 mm) diameter wheels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| R. | Wiring: All wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireways if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| S. | Door Locks: GAL type "N" | |||||||||||||||||||||||||||||||||||||||||||||||||
| T. | Door Locks: Fire rated electric door strike conform to ASME A18.1 b 2000. | |||||||||||||||||||||||||||||||||||||||||||||||||
| U. | Door Locks: Weather Resistant WR500. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.7 | SCREW VERTICAL PLATFORM LIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Screw Vertical Platform Lifts: Savaria - Multilift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Screw Vertical Platform Lift: The lift described here, manufactured by Savaria Lifts Inc., is a vertical platform lift consisting of a tower with a lifting platform. The platform can be customized to better accommodate a wheelchair user or a person with impaired mobility. The lift can be used indoor or outdoor (with optional package) and in commercial and residential applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 750 lb (340 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 8 fpm (0.04 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Car Dimensions: 34 inches W by 48 inches D (864 mm by 1219 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 34 inches W by 54 inches D (864 mm by 1372 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 34 inches by 60 inches (864 mm by 1524 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Car Access: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Car Access: Front/rear exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Travel: 48 inches (minimum) (1219 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Travel: 72 inches (maximum) (1827 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Operations: Constant pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Power Supply: 120 volt, 20 amp, 1 phase, 60 Hz. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Drive System: ACME screw and back-up nut. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Paint: Powder coat finish | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Emergency Power: Battery operation in down direction | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Controller: Electronic-free relay logic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Side Guard Panels: 42 inches (1067 mm) with metal inserts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Car Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Car operating panel shall consist of constant pressure buttons or rocker switches, an emergency stop button, and an on/off key switch. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Emergency operation- A manual hand crank is used to lower or raise the platform in case of emergency. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Acme Screw Drive: The screw should have a diameter of 1 inch (25 mm) and a back-up nut shall be installed for security reasons. No brakes are required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Leveling Device: All limit switches and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. They shall be located behind the mast wall and be accessible through removable panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Call Stations: Provide a surface, flush, or doorframe mounted call/send station. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Terminal Stopping Device: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Guide Rails and Bracket: Guide rails and brackets shall be used to guide the platform and sling. Roller guide shoes are bolted to the platform to make it roll on the rails. Guide rails shall form part of the structural integrity of the unit and be integral to the mast enclosure, ensuring stability and minimum platform deflection when loaded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Car Sling: Car sling shall be fabricated from steel tubing 44 inches high (1117 mm) with adequate bracing to support the platform and car enclosure. Roller guide shoes shall be mounted on the top and bottom of the car sling to engage the guide rails. Guide shoes to be roller type with 3 inches (76 mm) diameter wheels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Wiring: All wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture proof outer covering and shall be run in conduit, or electrical wire ways. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.8 | INCLINE WHEELCHAIR LIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Incline Wheelchair Lifts: Savaria ES-125P (Drive System Remotely Located). Inclined platform lift with an aircraft cable and winding drum assembly located under the stairs. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Incline Wheelchair Lifts: Savaria Model ES-125Plus (Drive System at the Top Landing). Inclined platform lift with a roller chain drive system designed for indoor or outdoor applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Lifts shall be erected, installed, adjusted, tested and placed in operation by lift system manufacturer, or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Lifts shall be in accordance with ASME A18.1 and ADA compliant including local codes and regulations except where specified otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | The following preparatory work to receive the lifts specified is part of other sections: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 120 VAC 20 amp single phase power to operate lift to be provided from lockable fused/cartridge type disconnect switch. Refer to drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square support wall with smooth interior surfaces. If support wall is not available, provide tread anchors for support posts. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide staircase per lift manufacturer's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 450 lb (204 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 14 fpm (0.071 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Car Dimensions: 27.5 inches W by 36 inches D (700 mm by 914 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 28.8 inches W by 44 inches D (724 mm by 1118 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 30 inches by 44 inches (762 mm by 1118 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 30 inches by 48 inches (762 mm by 1219 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Levels Serviced: 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Car Access: Front/Back exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Car Access: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Operations: Constant Pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Power Supply: 120V, 15 Amp, 1 Phase, 60 Hz. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Paint: Powder coat finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Emergency Operation: Manual lowering and rising. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Controller: Electronic-free relay logic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Safety Arms: Three folding positions: Up, down, center or powered up/down. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Passenger Seat (27.5 inches wide by 12 inches deep (699 mm by 305 mm), foldable with seat belt.) Required | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Passenger Seat (27.5 inches wide by 12 inches deep (699 mm by 305 mm), foldable with seat belt.) Not Required | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Platform Action: Motorized folding system at top and bottom landings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Platform Action: Manual folding system at top and bottom landings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Motor assembly: 120VAC, 1/2 hp, 1,750 rpm / gear reducer: 50:1. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Mechanical Provisions : | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Platform: The unit shall have an aircraft cable and winding drum drive system located under the stairs for a clean and quiet installation at the top landing. Platform may have a motorized folding mechanism. This folding action shall be done from the call station adjacent to the occupied landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Aircraft Cable: One aircraft cable with no less of 3/16 inch (5 mm) diameter, with breaking load of 4,200 lb (1907 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Platform: The unit shall have a roller-chain drive system, enclosed in a drive cabinet located at the upper landing. Platform may have a motorized folding mechanism. This folding action shall be done from the call station adjacent to the occupied landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Loading and unloading of safety ramps to be operated by a positive mechanical action when the car leaves the landing. The control of all power features are located in call stations so wheelchair users can be away from the stair until the platform is in loading position. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | The ramps are touch sensitive and shall stop the unit when encountering an obstruction on the stairs. The platform shall have a non-skid surface. Shaped to prevent accidental wheelchair roll-off. Sidewalls functions as vandal resistant cover to protect platform control switches when in folded position. A fold-up ambulatory seat, complete with safety belt is to be provided on the platform for disabled who do not use a wheelchair. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Platform Controls: Key switch, emergency stop, constant pressure call/send controls and hand pendant control for attendant operation. Platform ramps on both sides and platform underside with obstruction sensitive cut off assure safety. An audio-visual alarm shall be provided. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Controls at Each Landing: Key switch, constant pressure platform call/s end buttons and emergency stop switch. When using optional motorized platforms, constant pressure switches shall fold and unfold the platform. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Clearance: When folded, platform shall not protrude more than 13 inches (330 mm) from inner wall or more than 36-1/2 inches (927 mm) from inner wall in use unfolded (based upon direct mount to attachment wall). ANSI specification B-29.2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Emergency Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Hand wheel shall be provided for emergency operation during power failure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Safety brake shall be included in the mechanism in case of drive system failure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Slack cable switch that will stop the power in case of cable failure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Guide Rails And Brackets: Support rail to be steel, offset C-Channel. Rail to be directly mounted to solid walls or steel tower mounted to stair tread and stringer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Paint Color: To be selected by owner/architect from manufacturer's colors of powder coat finish. The standard color is almond beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Security Locks: A Security lock, utilizing the operation key, may be provided. This lock to prevent unauthorized unfolding of standard platform. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Electrical Provisions: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Power requirements to be 120 volt, single phase, 60 Hz, 15 amp. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Wheelchair lift shall have a disconnect switch, as required by code, to completely cut power to the unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | 24 volt control wiring: Wheelchair lift contractor shall provide the routing of conduits on or through wall, floors, and partitions along with the proper placement of junction boxes, call stations boxes and audio visual alert as required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | All electric wire or power cables shall be concealed in either rigid or flexible metal conduit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.9 | STAIRLIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Stairlift: Savaria Model B.07, stairlift designed for straight stairway, designed for indoor and outdoor applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | The following preparatory work to receive the lifts specified in this section is part or the work by others: Permanent 120 VAC, 15 amp, single phase power to operate lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 300 lb (136 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 8 fpm (0.04 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Angle of Incline: 25 degrees to 45 degrees. Refer to drawings | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Applications: Outdoor straight run stairway. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Applications: Indoor, straight run stairway. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Travel: Up to 32 feet (9754 mm). Refer to Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Operations: Constant pressure, 24VAC. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Power Supply: 120V, 15 amps, 1 phase, 60 Hz. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Drive System: Roller chain/sprocket. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Controller: Fused controlled circuit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Motor: 1/2 hp, 110VAC. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Seat Swivel: 90 degree, 45 degree top and bottom. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stairlift operation shall consist of constant pressure buttons or rocker switches located under the armrest of the carriage and on the call/send stations at both landings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Safety features: Slack chain switch, safety brake, seat swivel cut-off switch, obstacle sensors, and seatbelt. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Clearance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Unfolded, the unit shall be at a maximum of 25 inches (635 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Folded, the unit shall be at a maximum of 15-3/4 inches (400 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The rail shall be at a maximum of 10-1/2 inches (268 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The color of the rail is beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The color of the carriage and upholstery is beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Brackets: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The installer shall install at least 2 brackets per section of rail. The minimum length of a section is 24 inches (610 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The first and the last step of the stairway shall have a bracket. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The brackets are mounted to the steps with anchors. If stairs are covered with carpet, install an anchor in the front hole of the bracket. In the absence of carpet, two anchors/bracket are required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Terminal Stopping Device: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. A mechanical stopper shall be installed to stop the car if the electrical stopping devices are not functioning. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Wiring: All wiring and electrical connections shall comply with applicable codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.10 | STAIRLIFT | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Stairlift: Savaria Model Step Saver, stairlift designed for straight stairway, designed for indoor applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | The following preparatory work to receive the lifts specified in this section is part or the work by others: Permanent 120 VAC, 15 amp, single phase power to operate lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Characteristics: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Rated Load: 300 lb (136 kg). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Speed: 20 fpm (0.09 m/s). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Angle of Incline: 25 degrees to 50 degrees. Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Applications: Indoor, straight run stairway. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Travel: Up to 32 feet (9754 mm). Refer to drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Operations: Constant pressure, 24VAC. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Power Supply: 120V, 15 amps, 1 phase, 60 Hz. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Drive System: Rack and pinion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Controller: Fused controlled circuit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Motor: 1/2 hp, 24 VDC. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Seat Swivel: 90 degree, 45 degree top and bottom. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Stairlift operation shall consist of constant pressure buttons or rocker switches located under the armrest of the carriage and on the call/send stations at both landings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Safety features: Seat swivel cut-off switch, obstacle sensors, and seatbelt. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Clearance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Unfolded, the unit shall be at a maximum of 24-1/2 inches (622 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Folded, the unit shall be at a maximum of 15-1/2 inches (394 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The rail shall be at a maximum of inches (152 mm) from the back wall. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Color: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The color of the rail is beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The color of the carriage and upholstery is beige. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Brackets: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The installer shall install at least 2 brackets per section of rail. The minimum length of a section is 24 inches (610 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The first and the last step of the stairway shall have a bracket. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | The brackets are mounted to the steps with anchors. If stairs are covered with carpet, install an anchor in the front hole of the bracket. In the absence of carpet, two anchors/bracket are required. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Terminal Stopping Device: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. A mechanical stopper shall be installed to stop the car if the electrical stopping devices are not functioning. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Wiring: All wiring and electrical connections shall comply with applicable codes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.11 | COMMERCIAL PASSENGER ELEVATOR | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Limited Use Limited Application elevator: Savaria Orion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Work described in this section includes providing equipment, incidental material and labor required for complete, operable roped hydraulic passenger elevator installation. Elevator shall be erected, installed, adjusted, tested and placed in operation by system manufacturer, or manufacturer's authorized installer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Elevators shall be in accordance with the ASME A18. 1 and ADA compliant including local codes and regulations except where specified otherwise. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | The following preparatory work to receive the lifts specified in this section is part of the work of other sections: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Permanent 220 VAC, 50 amp single phase power to operate lift to be provided from a lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. 110 VAC, 15 amp single phase power to operate the lighting circuit. Refer to drawings for permanent power specifications and location of disconnects. Temporary power may be provided to expedite installation of lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Provide a plumb and square hoistway with smooth interior surfaces, including fascias or furring of the hoistway interior. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Provide rough openings per lift contractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Provide substantial, level pit floor slab as indicated on the lift contractor's shop drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Limited Use Limited Application elevator: The elevator described here, manufactured by Savaria Lifts Inc., is a LULA Elevator consisting of a roped hydraulic tower with a lifting platform. The platform can be customized to better accommodate a wheelchair user or a person with impaired mobility. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Savaria Model Orion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Rated Load: 1400 lb (635 kg) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Rated Speed: 25 f.p.m. (nominal) (0.13 m/s) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Car Dimensions: 48 inches W by 54 inches D (1219 mm by 1371 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Car Dimensions: 42 inches W by 60 inches D (1067mm by 1524 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Car Dimensions: 51 inches W by 51 inches D (1295mm by 1295 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Car Dimensions: 54 inches W by 54 inches D (1371 mm by 1371 mm) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Levels Serviced: 2. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Levels Serviced: 3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Levels Serviced: 4. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Openings: Enter/exit same side. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Openings: Enter/exit front/rear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Openings: 90 degree exit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Travel: ______ feet. Maximum of 25 feet (300 inches). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Operations: Automatic pressure. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Power Supply: 208 Volt, 3 Phase, 30 Amps. plus 110 volt, 15 amp, 1 phase, 60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Power Supply: 220 volt, 1 phase 50 amp, plus 110 volt, 15 amp, 1 phase, 60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Power Supply: 230 volt, 1 phase, 60 amp, plus 110 volt, 15 amp, 1 phase, 60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Drive System: 2:1 roped hydraulic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Paint: Powder coat finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Emergency Power: Battery operation in down direction | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Controller: PLC | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Motor/Pump: 220/208VAC, 5HP | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Manual Lowering: Outside the hoistway in machine room. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Car Enclosure: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Fire rated steel cab construction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Walls: Steel Walls (Architectural White, Black) (Standard) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Walls: Plastic Laminate Panels (Stone Grafix, Fog, Contract Mahogany, Natural Oak) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Ceiling Finish: Solid architectural white ceiling with four recessed incandescent down lights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Telephone Cabinet: Stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Lower and upper door and door frame with 1 1/2 hour ULC Fire rating, 2 speed, horizontally sliding. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Handrail: A single handrail, with 1-1/2 inch (38 mm) diameter rail and with both ends returned to the side guard, shall be located on the control wall of the cab. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Doors and Gates: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Landing Doors - Automatic: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | 1 1/2 hour UL/ULC fire rated assembly. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | 36 inches (914 mm) clear opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Concealed electro/mechanical interlock. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Two speed sliding doors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Concealed 24 volt door opener with battery back-up. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Car Operation: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Car Operating Panel shall consist of metal push bottoms with illuminated haloes, emergency stop/alarm button, on/off key switch and emergency light mounted on a removable stainless steel panel (Type 304 #4 Stainless Steel Finish). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Digital floor indicator and directional indicator in cab and at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Emergency Operation - The car shall be equipped with a battery operated light fixture, emergency battery lowering device and alarm in case of normal building supply failure. The battery shall be the rechargeable type with an automatic recharging system. A manual lowering device shall be located outside the hoistway in a lockable box positioned at a designated landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Fire Service: Phase 1 and Phase 2 fire Recall Service. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Pumping Unit and Control: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The pumping unit and control shall be enclosed in the tower. The controller and pump unit shall be pre-wired and tested prior to shipment. The controller is to be electronic-free with relay logic operation for ease of maintenance and service. Pump unit shall incorporate the following features : | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Smooth stops at each landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Submersible pump and motor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Adjustable pressure relief valve. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Manually operable down valve to lower lift in the event of an emergency. This valve shall be activated from outside of the hoistway through a keyed box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Pressure gauge isolating valve, manually operable. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Gate valve to isolate cylinder from pump unit. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Electrical solenoid for down direction control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Emergency lowering by battery power, from the car control. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Cylinder And Plunger: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Leveling Device: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | The lift shall be provided with an anti-creep device which will maintain the carriage level within 1/2 inch (12 mm) of the top landing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | All limit switch and leveling device switches shall be located in a position to be inaccessible to unauthorized persons. They shall be located behind the mast wall and be accessible through removable panels. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Guide Yoke: The 2:1 guide yoke assembly shall be supplied with two (2) sheaves, guide shoes, bearings and guards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Control Panel: Stainless steel control panel with tactile identifications (keyed stations). | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Terminal Stopping Devices: Normal terminal stopping devices shall be provided at top and bottom of runway to stop the car positively and automatically. Microswitches shall not be used. | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Guide Rails and Brackets: Steel 8 lb per ft guide rails and adjustable brackets shall be used to guide the platform and sling. | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Wiring: All wiring and electrical connections shall comply with applicable codes. Insulated wiring shall have flame-retardant and moisture-proof outer covering and shall be run in conduit or electrical wireways if located outside the unit enclosure. Quick disconnect harnesses shall be used when possible. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 3 | EXECUTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.1 | EXAMINATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Do not begin installation until hoistway and machine room has been properly prepared. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Site dimensions shall be taken to verify that tolerances and clearances have been maintained and meet local regulations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.2 | PREPARATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Clean surfaces thoroughly prior to installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.3 | ELEVATOR INSTALLATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Install in accordance with manufacturer's instructions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Install the components of the elevator system that are required and that are required by jurisdictional authorities to license the elevator. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Trained employees of the elevator contractor shall perform installation work. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Adjust elevator for proper operation and clean unit thoroughly. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Instruct users in operating procedures and owner's maintenance person in trouble-shooting and maintenance procedures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.4 | LIFT INSTALLATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Install all the components of the lift system that are specified in this section to be provided, and that are required by jurisdictional authorities to license the lift. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Trained employees of the lift contractor shall perform all installation work of this section. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Adjust lift for proper operation and clean unit thoroughly. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Instruct users in operation procedures and Owner's maintenance person in trouble-shooting and maintenance procedures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.5 | PROTECTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Protect installed products until completion of project. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Touch-up, repair or replace damaged products before Substantial Completion. | |||||||||||||||||||||||||||||||||||||||||||||||||