SECTION 076200
ROOF EDGE AND VENTILATION SYSTEMS
 
 
Copyright 2012 - 2015 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** Metal Era, Inc.; Roof edge and ventilation systems products.
.
This section is based on the products of Metal Era, Inc., which is located at:
1600 Airport Rd.
Waukesha, WI 53188
Toll Free Tel: 800-558-2162
Tel: 262-549-6900
Fax: 800-373-9156
Email: request info (info@metalera.com)
Web: www.metalera.com
[ Click Here ] for additional information.
We are a team dedicated to manufacturing quality products and finding solutions for the roofing industry. We are committed to listening to our customers and providing unsurpassed service and pledge to share our talents for mutual growth, prosperity and achievement in excellence.
For 30 years Metal-Era, Inc. has set out to fulfill this mission by representing the quality and service you expect from a commercial roof edge and roof ventilation manufacturer. You expect service that is unequaled in the industry, and you deserve a wide selection of engineered roof edge and roof ventilation solutions, designed to meet the roofing industry's strictest standards. These are the qualities Metal-Era offers you today.
Metal-Era's Roof Edge Solutions provides complete lines of fascia and coping products to meet a wide range of roof conditions and architectural requirements. These tested, warranted products are engineered and warranted to withstand some of the harshest wind conditions.
 
PART 1 GENERAL
 
1.1
SECTION INCLUDES
 
** NOTE TO SPECIFIER ** Delete items below not required for project.
 
A.
Metal Fascia.
B.
Metal Coping.
C.
Metal Gravel Stop,
D.
Metal Drip Edge.
E.
Metal Coping Cap.
F.
Vented and Non-Vented Eave and Fascia.
G.
Ridge Vent.
H.
Ballast paver terminations.
I.
Accessories.
1.2
RELATED SECTIONS
 
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
A.
Section 06 15 00 - Wood Decking.
B.
Section 06 16 36 - Wood Panel Product Sheathing.
C.
Section 06 20 00 - Finish Carpentry.
D.
Section 07 22 16 - Roof Board Insulation.
E.
Section 07 31 29.13 - Wood Shingles.
F.
Section 07 32 26 - Plastic Roof Tiles.
G.
Section 07 42 13 - Metal Wall Panels.
H.
Section 07 50 00 - Membrane Roofing.
I.
Section 07 62 00 - Sheet Metal Flashing and Trim.
J.
Section 07 72 63 - Waste Containment Assemblies.
1.3
REFERENCES
 
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
A.
ANSI/SPRI ES-1 - Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems.
B.
Florida Building Code, including the High Velocity Hurricane Zone.
C.
Miami-Dade County NOA No. 03-0108.06.
D.
Factory Mutual Research Corporation Approval Guide.
E.
SPRI Single Ply Roofing Industry Standards.
1.4
SUBMITTALS
A.
Submit under provisions of Section 01 30 00 - Administrative Requirements.
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
1.
Preparation instructions and recommendations.
2.
Storage and handling requirements and recommendations.
3.
Installation methods.
C.
Shop Drawings: Show profiles, joining method, location of accessory items, anchorage and flashing details, adjacent construction interface, and dimensions.
 
** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
D.
Selection Samples: For each finish product specified, two complete sets of color charts representing manufacturer's full range of available colors and patterns.
E.
Verification Samples: For each finish product specified, two sample chips representing actual product, color, and patterns.
F.
Manufacturer's Certificates: Certify products meet or exceed specified requirements.
1.5
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Company specializing in manufacturing Products specified in this section with minimum twenty five years documented experience.
B.
Installer Qualifications: Company specializing in the installation of products specified in this section with minimum five years documented experience.
 
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
C.
Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1.
Finish areas designated by Architect.
2.
Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
3.
Refinish mock-up area as required to produce acceptable work.
1.6
DELIVERY, STORAGE, AND HANDLING
A.
Store products in manufacturer's unopened packaging until ready for installation.
B.
Store materials in a dry, protected, well-vented area.
C.
Remove protective plastic surface film immediately before installation.
D.
Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
1.7
SEQUENCING
A.
Ensure that information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.
B.
Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.
C.
Coordinate installation with roof membrane manufacturer's installation instructions.
1.8
PROJECT CONDITIONS
A.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
1.9
WARRANTY
A.
Provide the manufacturer's warranty specified under products for the roof edge system, when installed per manufacturer's instructions. Warranty will not exceed the life of the roof membrane on which the product was originally installed.
B.
Provide a 30 year warranty for manufacturer approved 70 percent Kynar colors for the painted finish covering color fade, chalk, and film integrity.
PART 2 PRODUCTS
 
2.1
MANUFACTURERS
A.
Acceptable Manufacturer: Metal Era, Inc., which is located at: 1600 Airport Rd.; Waukesha, WI 53188; Toll Free Tel: 800-558-2162; Tel: 262-549-6900; Fax: 800-373-9156; Email: request info (info@metalera.com); Web: www.metalera.com
 
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
 
** NOTE TO SPECIFIER ** Edit the following paragraphs as required for the project requirements. Delete the paragraphs for the products not required.
 
2.2
ROOF EDGE PRODUCTS
A.
Anchor-Tite Standard Fascia: Decorative metal fascia with continuous extruded aluminum bar.
1.
Construction:
a.
Fascia metal gauge:
 
** NOTE TO SPECIFIER ** Select one of the following metal paragraphs and delete the one not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1 mm) thick formed aluminum.
2)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: Standard 12 feet 0 inches (3.65 m) lengths.
d.
Extruded bar: Shall be continuous 6063-T6 alloy aluminum at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.
1)
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
2)
Fasteners: 2 inch (51 mm) stainless steel with driver.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Fully Adhered or Mechanically Attached Single-Ply Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AF-55 -5-1/2 inch (139.7 mm) face height).
 
1)
AF-40.
2)
AF-55.
3)
AF-70.
4)
AF-85.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-645 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Built-Up or Modified Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AMF-55 -5-1/2 inch face height).
 
1)
AFM-55.
2)
AFM-70
3)
AFM-85.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-645 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
B.
Anchor-Tite HG Fascia: Two-part assembly consisting of a continuous extruded aluminum bar and exterior fascia with fasteners.
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
1)
.050 inch (1.27 mm) thick-formed aluminum.
2)
.063 inch (1.6 mm) thick-formed aluminum.
b.
Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
d.
Extruded bar: Shall be continuous 6063-T6 alloy aluminum at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.
1)
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
2)
Fasteners: 2 inch (51 mm) stainless steel with driver.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Fully Adhered or Mechanically Attached Single-Ply Version:
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. HG-AF--55 -5-1/2 inch (139.7 mm) face height).
 
1)
HG-AF-55.
2)
HG-AF-70.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3.
Built-Up or Modified Version:
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AF-55 -5-1/2 inch (139.7 mm) face height).
 
1)
HG-AFM -40.
2)
HG-AFM-55.
3)
HG-AFM-70.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
C.
Anchor-Tite Extended Fascia: A three-part assembly consisting of a continuous extruded aluminum bar, exterior fascia and continuous formed galvanized steel cleat with fasteners.
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
1)
.050 inch (1.27 mm) thick-formed aluminum.
2)
.063 inch (1.6 mm) thick-formed aluminum.
b.
Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
d.
Extruded Bar: Shall be continuous 6063-T6 alloy aluminum in 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.
1)
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
2)
Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.
e.
Anchor Bar Cleat: Standard 12 feet 0 inches (3.65 m) lengths of commercial type 20 gauge G-90 galvanized steel with pre-punched holes.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Fully Adhered or Mechanically Attached Single-Ply Version:
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEF-85 -8-1/2 inch (216 mm) face height).
 
1)
AEF-85.
2)
AEF-100.
3)
AEF-115.
4)
AEF-130.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-270 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Built-Up or Modified Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFM-85 - 8-1/2 inch (216 mm) face height).
 
1)
AEFM-85.
2)
AEFM-100.
3)
AEFM-115.
4)
AEFM-130.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-270 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
D.
Anchor-Tite Canted Fascia: Three-part assembly consisting of a continuous extruded aluminum bar, exterior fascia and continuous formed galvanized steel cleat with fasteners.
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
1)
.050 inch (1.27 mm) thick-formed aluminum.
2)
.063 inch (1.6 mm) thick-formed aluminum.
b.
Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
d.
Extruded Bar: Shall be continuous 6063-T6 alloy aluminum in 12 feet 0 inches (3.65 m) standard lengths with pre-punched slotted holes. All bar miters are welded.
1)
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
2)
Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.
e.
Waterdam: Standard 12 feet 0 inches (3.65 m) lengths of commercial type 24 gauge G-90 galvanized steel with pre-punched slotted holes.
f.
Anchor Bar Cleat: Standard 12 feet 0 inches (3.65m) lengths of commercial type 20 gauge G-90 galvanized steel with pre-punched holes.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Existing Beveled Wood Nailer Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFC-1200 - 12 inch face height).
 
1)
AEFC-55.
2)
AEFC-900.
3)
AEFC-1050.
4)
AEFC-1200.
5)
AEFC-1350.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Galvanized Waterdam Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. AEFC-1052 - 10-1/2 inch face height).
 
1)
AEFC-552.
2)
AEFC-902.
3)
AEFC-1052.
4)
AEFC-1202.
5)
AEFC-1352.
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-270 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
E.
Anchor-Tite Extended Canted Fascia:
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.063 inch (1.6 mm) aluminum.
b.
Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Extruded aluminum anchor bar.
d.
Interlocking, concealed splice plate design prevent splice plate migration under the fascia panels.
1)
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
2)
Fasteners: 2 inch (51 mm) stainless steel and 1/4 inch (6 mm) by 1-1/4 inch (32 mm) masonry/wood with driver.
e.
Provided with anchor bar EPDM splice plates and fasteners.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Existing Beveled Wood Nailer Version
a.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
8-1/2 inch (215.9 mm).
2)
10 inch (254 mm).
3)
11-1/2 inch (292.1 mm).
4)
13 inch (330.2 mm).
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Galvanized Waterdam Version
a.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
8-1/2 inch (215.9 mm).
2)
10 inch (254 mm).
3)
11-1/2 inch (292.1 mm).
4)
13 inch (330.2 mm).
b.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 190 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-270 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
F.
Perma-Tite System 200 Fascia: Decorative metal fascia with continuous galvanized steel waterdam to terminate single-ply roofing at perimeter.
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
d.
Waterdam: Continuous 24 gauge commercial type G-90 galvanized steel at 12 feet 0 inches (3.65 m) standard lengths.
e.
Fasteners: 1-1/4 inch (32 mm) Galvanized Ring Shank Roofing Nails.
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
2.
Single-Ply Application, Snap-On Version with 24 gauge (.65 mm) spring clips 4 foot (1.22 m) o.c.
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. FA-1052 - 10-1/2 inch face height).
 
1)
FA-50.
2)
FA-65.
3)
FA-80.
4)
FA-95.
5)
FA-110.
6)
FA-125.
b.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Face heights of 5-1/4 inch to 8-1/4 inch are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft[2] and face heights of 9-3/4 inch to 12-3/4 inch are tested to a design pressure of 110 lbs./ft[2] to comply with the International Building Code.
3.
Single-Ply Application, Crimp-On Version
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. FA-1052 - 10-1/2 inch face height).
 
1)
FA-50.
2)
FA-65.
3)
FA-80.
4)
FA-95.
5)
FA-1010.
6)
FA-1025.
b.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
All face heights tested per ANSI/SPRI ES-1 Standard to a design pressure of 150 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-195 approved for wind up lift protection.
G.
Perma-Tite System 300 Fascia: Decorative metal fascia with continuous galvanized steel waterdam to terminate built-up or modified roofing at perimeter.
1.
Construction:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
d.
Waterdam: Shall be continuous 24 gauge commercial type G-90 galvanized steel at 12 feet 0 inches (3.65 m) standard lengths.
e.
Fasteners: 1-1/4 inch (32 mm) galvanized ring shank roofing nails.
2.
Built-Up or Modified Application, Snap-On Version with 24 gauge (.65mm) spring clips 4 feet (1.22 m) o.c.
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. FA-1052 - 10-1/2 inch face height).
 
1)
FA-350.
2)
FA-365.
3)
FA-380.
4)
FA-395.
5)
FA-3110.
6)
FA-3125.
b.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Face heights of 5-1/4 inch to 8-1/4 inch are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft[2] and face heights of 9-3/4 inch to 12-3/4 inch are tested to a design pressure of 110 lbs./ft[2] to comply with the International Building Code.
3.
Built-Up or Modified Application, Crimp On Version w/Continuous .025 inch (.64 mm) mill finish aluminum Compression Clamp
a.
Model:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required. Note that fascia model number denotes height in inches; (i.e. FA-355 - 5-1/2 inch (139.7 mm) face height).
 
1)
FA-355.
2)
FA-370.
b.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Face heights of 5-1/4 inch to 8-1/4 inch are tested per ANSI/SPRI ES-1 Standard to a design pressure of 160 lbs./ft[2] and face heights of 9-3/4 inch to 12-3/4 inch are tested to a design pressure of 110 lbs./ft[2] to comply with the International Building Code.
H.
Creative Design Bullnose Fascia:
 
** NOTE TO SPECIFIER ** Select the Version(s) required the following paragraphs and delete those not required.
 
1.
Fully Adhered or Mechanically Attached Single-Ply Version:
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
4 inch (102 mm).
2)
5-1/2 inch (139.7 mm).
3)
7 inch (177.8 mm).
4)
8-1/2 inch (215.9 mm).
d.
Cover provided in 4 foot 0 inch (1.22 m) lengths with pre-punched holes for quicker installation. Extruded aluminum anchor bar provided in 12 foot 0 inch (3.65m) lengths. Fastening holes are slotted to allow for proper thermal movement of the materials and ensure correct fastener placement and spacing.
e.
Provide with extruded aluminum anchor bar and splice plates to securely terminate the membrane.
f.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-120 approved for wind up lift protection.
2.
Stone Ballast Single-Ply Version
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
5 inch (127 mm).
2)
6-1/2 inch (165 mm).
3)
8 inch (203 mm).
d.
Provide in 4 foot 0 inch (1.22 m) lengths with pre-punched holes for quicker installation. Extruded aluminum anchor bar provided in 12 foot 0 inch (3.65m) lengths. Fastening holes are slotted to allow for proper thermal movement of the materials and ensure correct fastener placement and spacing.
e.
Provide with extruded aluminum anchor bar and splice plates to securely terminate the membrane.
f.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft[2] to comply with the International Building Code.
g.
Factory Mutual 1-120 approved for wind up lift protection.
3.
Built-Up or Modified Version
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
5-1/2 inch (139.7 mm).
2)
7 inch (177.8 mm).
3)
8-1/2 inch (215.9 mm)
d.
Provide in 4 foot 0 inch (1.22 m) lengths with pre-punched holes for quicker installation. Extruded aluminum anchor bar provided in 12 foot 0 inch (3.65m) lengths. Fastening holes are slotted to allow for proper thermal movement of the materials and ensure correct fastener placement and spacing.
e.
Provide with extruded aluminum anchor bar and splice plates to securely terminate the membrane.
f.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 290 lbs./ft[2] to comply with the International Building Code.
3)
Factory Mutual 1-120 approved for wind up lift protection.
I.
Creative Design Cornice Fascia:
1.
Type:
 
** NOTE TO SPECIFIER ** Select Type required from the following paragraphs and delete those not required.
 
a.
Fully Adhered or Mechanically Attached Single-Ply Version.
b.
Built-Up or Modified Version.
2.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
a.
.050 inch (1.27 mm) aluminum.
b.
.063 inch (1.6 mm) aluminum.
c.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
3.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
a.
8 inch (203 mm).
b.
10 inch (254 mm).
c.
11-1/2 inch (292.1 mm).
d.
13 inch (330.2 mm).
4.
Provide in 4 foot 0 inch (1.22 m) lengths with pre-punched holes for quicker installation. Extruded aluminum anchor bar provided in 12 foot 0 inch (3.65m) lengths. Fastening holes are slotted to allow for proper thermal movement of the materials and ensure correct fastener placement and spacing.
5.
Provide with extruded aluminum anchor bar and splice plates to securely terminate the membrane.
6.
Performance:
a.
20 Year, 110 mph Wind Warranty.
J.
Creative Design Shadow Line Fascia
1.
Type:
 
** NOTE TO SPECIFIER ** Select Type required from the following paragraphs and delete those not required.
 
a.
Fully Adhered or Mechanically Attached Single-Ply Version.
b.
Built-Up or Modified Version.
2.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
a.
.050 inch (1.27 mm) aluminum.
b.
.063 inch (1.6 mm) aluminum.
c.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
3.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
a.
8-1/2 inch (215.9 mm).
b.
10 inch (254 mm).
c.
11-1/2 inch (292 mm).
d.
13 inch (330 mm).
4.
Provide in 12 feet 0 inches lengths with pre-punched holes for quicker installation. Fastening holes are slotted to allow for proper thermal movement of the materials and ensure correct fastener placement and spacing.
5.
Provide with extruded aluminum anchor bar and splice plates to securely terminate the membrane.
6.
Performance:
a.
20 Year, 110 mph Wind Warranty.
K.
Edge Systems One Drip Edge: Features an "L" shaped continuous cleat with pre-slotted fastening holes.
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
3.
Splice Plates and 22 gauge galvanized continuous cleats with slotted holes are included
4.
Performance:
a.
5 Year Workmanship Warranty.
b.
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
L.
Edge Systems One Gravel Stop: Features an "L" shaped continuous cleat with pre-slotted fastening holes.
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Fascia: standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates.
3.
Splice Plates and 22 gauge galvanized continuous cleats with slotted holes are included
4.
Performance:
a.
5 Year Workmanship Warranty.
M.
Edge Systems One: One Edge Fascia: Decorative metal fascia to terminate single ply roofing at perimeter.
1.
Construction:
a.
Cover Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia Covers: Standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates. Cover height shall be:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
 
1)
4 inches.
2)
5 inches.
3)
6-1/2 inches.
4)
8 inches.
5)
As indicated on the Drawings.
d.
Formed Rail: Shall be 20 gauge commercial type G-90 galvanized steel at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slots 12 inches o.c. Provided with stainless steel spring mechanically locked to clips 4 foot 0 inch (1.22 m) on center.
e.
Fasteners: 1-1/4 inch (32 mm) galvanized ring shank roofing nails.
f.
Performance:
1)
20 Year, 110 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 200 lbs./sf to comply with the International Building Code.
3)
Florida Building Code Approved.
4)
Factory Mutual 1-225 approved with Aluminum Rail.
N.
Edge Systems One: CM One Drip Edge: Decorative metal fascia to terminate PVC or TPO roofing at perimeter and designed to simplify heat welding flashing.
1.
Construction:
a.
Cover Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Fascia Covers: Standard 12 feet 0 inches (3.65 m) lengths with matching concealed joint splice plates. Cover height shall be:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete the ones not required.
 
1)
3-3/4 inches.
2)
4 inches.
3)
5 inches.
4)
6 inches.
5)
7 inches.
6)
8 inches.
7)
As indicated on the Drawings.
d.
Formed Rail: Shall be 20 gauge commercial type G-90 galvanized steel at 12 feet 0 inches (3.65 m) standard lengths with pre-punched slots 12 inches o.c.
e.
Fasteners: 1-1/4 inch (32 mm) galvanized ring shank roofing nails.
f.
Performance:
1)
10 Year, 72 mph Wind Warranty.
2)
Tested per ANSI/SPRI ES-1 Standard to a design pressure of 210 lbs./sf to comply with the International Building Code.
3)
Florida Building Code Approved.
O.
Perma-Tite Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: length of 12 feet 0 inches (3.65 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
2)
Coping vertical face and back leg: 2-1/4 inch to 12-1/2 inch (57 mm to 3175 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
4)
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
 
** NOTE TO SPECIFIER ** Select the Version(s) required from the following paragraphs and delete those not required.
 
2.
Flat Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
4.
Over 6 inch to 12 inch Face Height, Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual approved for wind up lift protection.
5.
Over 6 inch to 12 inch Face Height, Masonry Attached Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
6.
Larger than 16 inch Wall Size Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
7.
Existing Slope with Nailer Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
8.
Existing Slope without Nailer Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
9.
Existing Slope without Nailer, Over 6 inch to 12 inch Face Height, Masonry Attached Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
10.
Double Tapered Coping:
a.
Performance:
1)
20 Year, 110 mph Wind Warranty.
P.
Perma-Tite Continuous Cleat Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: length of 12 feet 0 inches (3.65 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
2)
Coping vertical face and back leg: 2-1/4 inch to 12-1/2 inch (57 mm to 3175 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
4)
Continuous Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
 
** NOTE TO SPECIFIER ** Select the Version(s) required from the following paragraphs and delete those not required.
 
2.
Flat Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
3.
Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
4)
Miami-Dade Approved (No. 13-0419.03 12/11/18) to comply with the "High Velocity Hurricane Zone of the Florida Building Code".
4.
Over 6 inch to 12 inch Face Height, Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual approved for wind up lift protection.
5.
Over 6 inch to 12 inch Face Height, Masonry Attached Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
6.
Larger than 16 inch Wall Size Tapered Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
7.
Existing Slope with Nailer Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
8.
Existing Slope without Nailer Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
9.
Existing Slope without Nailer, Over 6 inch to 12 inch Face Height, Masonry Attached Version
a.
Performance:
1)
20 Year, 110 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
10.
Double Tapered Coping:
a.
Performance:
1)
20 Year, 110 mph Wind Warranty.
Q.
Perma-Tite Gold Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: Length of 12 feet 0 inches (3.65 m), widths to 30 inch (762 mm) manufactured to job requirements. True radii may be built to template.
2)
Coping vertical face and back leg: 2-3/4 inch to 12 inch (69.85 mm to 304.8 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
4)
Anchor/Support Cleat: 16 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 3 foot 0 inch (.9144 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
 
** NOTE TO SPECIFIER ** Select the Version(s) required from the following paragraphs and delete those not required.
 
2.
Tapered Version
a.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
3.
Over 6 inch to 12 inch Face Height, Tapered Version
a.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
4.
Larger than 16 inch Wall Size Tapered Version
a.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
R.
Perma-Tite Gold Cantilever Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cover: Length of 12 feet 0 inches (3.65 m), widths to 32 inch (813 mm) manufactured to job requirements.
a)
Coping vertical outside face: 3-1/2 inch to 6 inch (88.9 mm to 152.4 mm) manufactured to job requirements.
b)
Coping vertical inside face: 2-3/4 inch to 6 inch (69.85 mm to 152.4 mm) manufactured to job requirements.
2)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
3)
Anchor/Support Clips: 16 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to clip normally 12 inch (305 mm) wide at 3 foot 0 inch (.9144 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
e.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
S.
Welded Radius Coping
1.
Construction:
a.
Metal:
1)
Inside and Outside Faces: .063 inch (1.6 mm) aluminum.
2)
Top of coping: 080 inch (2.03 mm).
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
2)
Coping vertical face and back leg: 2-1/4 inch to 12 (57 mm to 305 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
e.
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
T.
Quicklock Radius Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
2)
Coping vertical face and back leg: 2-1/4 inch to 12 (57 mm to 305 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
4)
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
U.
Arched Coping: Full, snap-on design with no crimping. Pre-punched fastening holes ensure proper attachment to the building substrate.
1.
Metal:
a.
100 inch (2.54 mm) mill finished aluminum.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Splice Plates: Interlocking, concealed splice plate design prevents splice plate migration under the fascia panels.
c.
Corrosion resistant, stainless steel springs are factory attached to the anchor clips and provide long-term, positive spring loading. No adhesives are required.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Performance:
a.
5 Year Workmanship Warranty.
V.
Arched Coping: Top Fasten Version: Pre-punched fastening holes ensure proper attachment to the building substrate.
1.
Metal:
a.
.100 inch (2.54 mm) mill finished aluminum.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Splice Plates: Interlocking, concealed splice plate design prevents splice plate migration under the fascia panels.
c.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Performance:
a.
5 Year Workmanship Warranty.
W.
Arched Coping: Snap-On Version with 24 gauge (.65 mm) spring clips 4 foot (1.22 m) o.c.
1.
Metal:
a.
.100 inch (2.54 mm) mill finished aluminum.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Splice Plates: Interlocking, concealed splice plate design prevents splice plate migration under the fascia panels.
c.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Performance:
a.
5 Year Workmanship Warranty.
X.
Creative Design Reveal Coping
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cap: length of 12 feet 0 inches (3.65 m), widths 7-1/4 inch (184mm) to 24 inch (609 mm) manufactured to job requirements.
2)
Coping vertical face and back leg: 6-1/2 inch to 12 inch (165 mm to 304.8 mm) manufactured to job requirements.
3)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
4)
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 3 foot 0 inch (.914 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
e.
Performance:
1)
20 year, 110 mph Wind Warranty
Y.
Creative Design Stone-Look Coping:
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
a.
.050 inch (1.27 mm) aluminum.
b.
.063 inch (1.6 mm) aluminum.
c.
Aluminum Finish: Kynar with 1 base color and 2 spatter colors with a stone like appearance.
2.
Construction:
a.
Coping cap: length of 4 foot 0 inch (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Coping vertical face and back leg: 2-3/4 inch (69.85 mm) to 6 inch (152.5 mm) manufactured to job requirements.
c.
Concealed splice plates: 8 inch (203 mm) wide "tooled". Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (305 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
e.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Performance:
a.
20 Year, 110 mph Wind Warranty
Z.
Creative Design Bullnose Coping: Metal coping cap with galvanized steel anchor/support cleats for capping any parapet wall. Joints area butt type with concealed splice plates.
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required.
 
a.
.050 inch (1.27 mm) aluminum.
b.
.063 inch (1.6 mm) aluminum.
c.
Custom metal ______.
d.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 4 feet 0 inches (1.22 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Coping vertical face and back leg: manufactured to job requirements.
c.
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (304.8 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
e.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Model:
 
** NOTE TO SPECIFIER ** Standard model is (BNC) for all sizes.
 
a.
BNC.
4.
Performance:
a.
20 Year, 110 mph Wind Warranty.
AA.
Creative Design Bold Face Coping: Metal coping cap with galvanized steel anchor/support cleats for capping any parapet wall. Joints are butt type with concealed splice plates.
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
22 gauge galvanized steel.
f.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 12 feet 0 inches (3.65 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Coping vertical face: 41/2" minimum to 8 inch (203 mm) maximum, and back leg: 2-1/4 inch to 6 inch (57.1 m to 152 mm) manufactured to job requirements.
c.
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Anchor/Support Cleat: 20 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to cleat normally 12 inch (304.8 mm) wide at 4 foot 0 inch (1.22 m) on center. Mechanically fastened as indicated and detailed.
e.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Model:
 
** NOTE TO SPECIFIER ** Standard model is (BCF) for all sizes.
 
a.
BCF.
4.
Performance:
a.
20 Year, 110 mph Wind Warranty.
b.
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
c.
Factory Mutual 1-90 approved for wind up lift protection.
AB.
Creative Design Leak-Tite Coping:
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 12 feet 0 inches (3.65 m).
b.
Coping vertical face: outside face: minimum 4-1/2 inch to 8 inch (114 mm to 203 mm) maximum, and inside face: minimum 2-1/4 inch to 6 inch (57.1 m to 152 mm) maximum manufactured to job requirements.
c.
Splice plates: Dual factory applied isocryl butyl sealant strips with a formed raised rib on either side of the cover joints for increased leak protection. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Anchor Clips: 20 gauge galvanized steel anchor clips with factory applied stainless steel springs.
e.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
AC.
Creative Design Cornice Coping: Metal cornice coping cap with galvanized steel anchor/support cleats for capping any parapet wall. Joints area butt type with concealed splice plates. Cornice profile as indicated on the Drawings.
1.
Metal:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Construction:
1)
Coping cover: Length of 12 feet 0 inches (3.65 m), widths to 32 inch (813 mm) manufactured to job requirements.
a)
Coping cornice outside face: 3-1/2 inch to 6 inch (88.9 mm to 152.4 mm) manufactured to job requirements.
b)
Coping vertical inside face: 2-3/4 inch to 6 inch (69.85 mm to 152.4 mm) manufactured to job requirements.
2)
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
3)
Anchor/Support Clips: 16 gauge pre-punched galvanized cleat with stainless steel spring mechanically locked to clip normally 12 inch (305 mm) wide at 3 foot 0 inch (.9144 m) on center. Mechanically fastened as indicated and detailed.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
e.
Performance:
1)
Lifetime, 215 mph Wind Warranty
2)
Tested per ANSI/SPRI ES-1 Standard to comply with the International Building Code.
3)
Factory Mutual 1-90 approved for wind up lift protection.
AD.
Creative Design Accent Lighted Coping: Metal coping cap with galvanized steel anchor/support cleats for capping any parapet wall and provides accent lighting to the outside of the building. Joints are butt type with concealed splice plates.
1.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
22 gauge galvanized steel.
f.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Construction:
a.
Coping cap: length of 12 feet 0 inches (3.65 m), widths to 24 inch (101.6 mm) manufactured to job requirements. True radii may be built to template.
b.
Coping vertical face: outside face: minimum 4-1/2 inch to 8 inch (114 mm to 203 mm)maximum, and inside face: minimum 2-1/4 inch to 6 inch (57.1 m to 152 mm) maximum manufactured to job requirements.
c.
Concealed splice plates: 8 inch (203 mm) wide. Finish to match finish of coping cap with factory applied dual non-curing sealant strips.
d.
Fasteners: 1-1/2 inch (38 mm) Stainless Steel with driver.
3.
Model:
 
** NOTE TO SPECIFIER ** Standard model is (ALC) for all sizes.
 
a.
ALC.
4.
Performance:
a.
20 Year, 110 mph Wind Warranty.
AE.
PMR Lock Type I Retainer Bar: Fascia system for ballast pavers.
1.
Lightweight Protected Membrane Roofing Version
2.
Metal:
a.
100 inch (2.54 mm) aluminum.
3.
Construction:
a.
Interlocking, concealed splice plate design prevents splice plate migration under the fascia panels.
4.
Performance:
AF.
WL-100 Ballast Paver Fascia: Fascia system for ballast pavers.
1.
Westile Ballast Paver Version.
2.
Sizes:
a.
7 inch (177.8 mm).
3.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
a.
.040 inch (1.01 mm) aluminum.
b.
.050 inch (1.27 mm) aluminum.
c.
.063 inch (1.6 mm) aluminum.
d.
24 gauge galvanized steel.
e.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
4.
Construction:
a.
Provided in 12 feet 0 inches (3.65 m) lengths with pre-punched holes.
b.
Anchor bar EPDM splice plates and fasteners are included.
c.
Injection Molded EPDM Bar Splice to allow thermal movement expansion of extruded aluminum anchor bar.
d.
Fasteners: 2 inch (51 mm) Stainless Steel with driver.
5.
Performance:
a.
Lifetime, 170 mph Wind Warranty.
AG.
WL-200-1 Interlocking Edge Retainer: Fascia system for ballast pavers.
1.
Westile Ballast Paver Version.
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 22 gauge stainless steel is available unfinished only.
 
1)
.050 inch (1.27 mm) aluminum.
2)
22 gauge stainless steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Performance:
a.
5 Year Workmanship Warranty.
AH.
WL-200-B Butt Edge Retainer: Fascia system for ballast pavers.
1.
Westile Ballast Paver Version.
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 22 gauge stainless steel is available unfinished only.
 
1)
.050 inch (1.27 mm) aluminum.
2)
22 gauge stainless steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
2.
Performance:
a.
5 Year Workmanship Warranty.
AI.
WL-600 Paver Termination Bar: Fascia system for ballast pavers.
1.
Westile Ballast Paver Version.
a.
Sizes:
 
** NOTE TO SPECIFIER ** Select one of the following paragraphs and delete those not required.
 
1)
6 inches (152 mm).
2)
9 inches (229 mm).
2.
Metal: .080 inch (2.03 mm) aluminum.
3.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
a.
Natural aluminum mill finish.
b.
Clear anodized aluminum.
c.
Black anodized Aluminum.
d.
Dark Bronze anodized aluminum.
e.
Extra Dark Bronze anodized aluminum.
f.
Champagne anodized aluminum.
g.
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
h.
Custom Kynar-500 color as selected by the Architect.
4.
Splice plates are included.
5.
Performance:
a.
5 Year Workmanship Warranty.
AJ.
Perma-Tite Expansion Joint: Expansion joint prevents condensation by insulating against internal building temperatures.
1.
Roof to Roof Version
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Provided in 12 feet 0 inches (3.65 m) lengths with pre-punched holes.
d.
Concealed splice plate design.
e.
Provided with special articulatory cleat that allows four-way movement for the expansion and contraction.
f.
Performance:
1)
5 Year Workmanship Warranty.
2.
Roof to Wall Version
a.
Fascia Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Provided in 12 feet 0 inches (3.65 m) lengths with pre-punched holes.
d.
Concealed splice plate design.
e.
Provided with special articulatory cleat that allows four-way movement for the expansion and contraction.
f.
Performance:
1)
5 Year Workmanship Warranty.
AK.
Hi-Perf Vented Fascia:
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Perforated Support Screen: 24 gauge formed steel with 54 percent free openings.
d.
Roof Flange and Backer Material: G90 Galvanized Steel with Formed Aluminum Studs.
2.
System:
 
** NOTE TO SPECIFIER ** Select the system model(s) required from the following paragraphs and delete those not required.
 
a.
Vented Nailbase Version:
1)
Model HPNB-60 - 6 inch Coverage.
2)
Model HPNB-80 - 8 inch (203 mm) Coverage.
3)
Model HPNB-100 -10 inch Coverage.
4)
Model HPNB-120 -12 inch Coverage.
5)
Model HPNB-140 -14 inch (101.6 mm) Coverage.
6)
Model HPNB-160 -16 inch Coverage.
7)
Model HPNB-___ (Insert Coverage to 1/16 Inch)
b.
Attic Vented Version:
1)
Model HPAV-60 - 6 inch Coverage.
2)
Model HPAV-80 - 8 inch (203 mm) Coverage.
3)
Model HPAV-100 -10 inch Coverage.
4)
Model HPAV-120 -12 inch Coverage.
5)
Model HPAV-140 -14 inch (101.6 mm) Coverage.
6)
Model HPAV-160 -16 inch Coverage.
7)
Model HPAV-___ (Insert Coverage to 1/16 Inch)
3.
Performance:
 
** NOTE TO SPECIFIER ** Indicate the net free area required on the Drawings for the system specified.
 
a.
Ventilation: Must meet the required net free air per linear foot (nfa/lf) as determined by the vented roof deck system and eave condition as indicated on the Drawings.
b.
20 Year, 120 mph Wind and Ventilation Warranty.
AL.
Hi-Perf Rake Fascia:
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
b.
Aluminum Finish:
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Closure: 24 gauge formed steel.
d.
Roof Flange and Backer Material: G90 Galvanized Steel with Formed Aluminum Studs.
2.
System:
 
** NOTE TO SPECIFIER ** Select the system model(s) required from the following paragraphs and delete those not required.
 
a.
Model HPRF-60 - 6 inch Coverage.
b.
Model HPRF-80 - 8 inch Coverage.
c.
Model HPRF-100 -10 inch Coverage.
d.
Model HPRF-120 -12 inch Coverage.
e.
Model HPRF-140 -14 inch Coverage.
f.
Model HPRF-160 -16 inch Coverage.
g.
Model HPRF-___ (Insert Coverage to 1/16 Inch)
3.
Performance: 5 Year Workmanship Warranty.
AM.
Hi-Perf Rake Panel:
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
b.
Aluminum Finish:
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Roof Flange and Backer Material: G90 Galvanized Steel
2.
System:
 
** NOTE TO SPECIFIER ** Select the system model(s) required from the following paragraphs and delete those not required.
 
a.
Model HPRP-60 - 6 inch Coverage.
b.
Model HPRP-80 - 8 inch Coverage.
c.
Model HPRP-100 -10 inch Coverage.
d.
Model HPRP-120 -12 inch Coverage.
e.
Model HPRP-140 -14 inch Coverage.
f.
Model HPRP-160 -16 inch Coverage.
g.
Model HPRP-___ (Insert Coverage to 1/16 Inch)
3.
Performance: 5 Year Workmanship Warranty
AN.
Hi-Perf Intake Vent:
1.
Construction:
a.
Metal:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
1)
.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
b.
Aluminum Finish:
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Expanded Metal Support Screen: .050 inch (1.27 mm) Formed Aluminum.
d.
Continuous 'Z' Brackets: 20ga G90 Galvanized Steel.
2.
Vent System:
 
** NOTE TO SPECIFIER ** Select the vent system model(s) required from the following paragraphs and delete those not required.
 
a.
Shingled Version On Slope: HPIV
3.
Performance:
 
** NOTE TO SPECIFIER ** Indicate the net free area required on the Drawings for the vent system specified.
 
a.
Ventilation: Must meet the required net free air per linear foot (nfa/lf) as determined by the vented roof deck system and eave condition as indicated on the Drawings.
b.
20 Year, 120 mph Wind and Ventilation Warranty
AO.
Hi-Perf Ridge Vent:
1.
Construction:
 
** NOTE TO SPECIFIER ** Select Metal type and thickness required from the following paragraphs and delete those not required. Note that 24 and 22 gauge galvanized steel is available unfinished only.
 
a.
Metal:
1)
1.040 inch (1.01 mm) aluminum.
2)
.050 inch (1.27 mm) aluminum.
3)
.063 inch (1.6 mm) aluminum.
4)
24 gauge galvanized steel.
5)
22 gauge galvanized steel.
 
** NOTE TO SPECIFIER ** Select one of the following finish paragraphs and delete the one not required.
 
b.
Aluminum Finish:
1)
Natural aluminum mill finish.
2)
Clear anodized aluminum.
3)
Black anodized Aluminum.
4)
Dark Bronze anodized aluminum.
5)
Extra Dark Bronze anodized aluminum.
6)
Champagne anodized aluminum.
7)
Standard color Kynar-500 as selected by the Architect from roof edge manufacturer's color chart.
8)
Custom Kynar-500 color as selected by the Architect.
c.
Expanded Metal Support Screen: .050 inch (1.27 mm) Formed Aluminum.
d.
Continuous Z Brackets: 20ga G90 Galvanized Steel.
2.
Vent System:
 
** NOTE TO SPECIFIER ** Select the vent system model(s) required from the following paragraphs and delete those not required.
 
a.
Slope to Slope Shingled Version: HPS.
b.
Slope to Slope Shingled For Heavy Snow Load Conditions: HPS-HSL.
c.
Slope to Slope Standing Seam Version: Model: HPSS.
d.
Slope to Slope Standing Seam for Heavy Snow Load Conditions: HPSS-HSL.
e.
Sloped to Sloped Field Roofed Version: HPFR
f.
Sloped Roof Meets High Wall Version: Model: HPSH.
g.
Sloped Roof Meets Vertical Wall Version: Model: HPSV.
h.
Sloped Roof Meets Flat Roof Version: Model: HPSF.
3.
Performance:
 
** NOTE TO SPECIFIER ** Indicate the net free area required on the Drawings for the vent system specified.
 
a.
Ventilation: Must meet the required net free air per linear foot (nfa/lf) as determined by the vented roof deck system and eave condition as indicated on the Drawings.
b.
20 Year, 120 mph Wind and Ventilation Warranty
c.
Meets Florida Building Code (HZHZ) Test Protocol TAS 100(A)-95 Test Procedure for wind and wind driven rain resistance and/or increased wind speed resistance of soffit ventilation strip and intermittent ventilation system installed at ridge area.
2.3
ACCESSORIES
A.
Miters and end caps shall be fabricated by manufacturer to suit the conditions indicated on the Drawings.
B.
Provide fasteners consistent with manufacturer's instructions for each product that is suitable for the substrate to which it is being installed.
PART 3 EXECUTION
 
3.1
EXAMINATION
A.
Do not begin installation until substrates have been properly prepared.
B.
Verify that the substrate is dry, clean and free of foreign matter.
C.
If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
3.2
PREPARATION
A.
Clean surfaces thoroughly prior to installation.
B.
Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
C.
Verify the manufacturer's roof edge details for accuracy to fit the assembly prior to fabrication.
3.3
INSTALLATION
A.
Install in accordance with manufacturer's installation instructions.
B.
Use provided fasteners consistent with manufacturer's instructions, suitable for the substrate to which it is being installed.
C.
Install water cut-off, as recommended by the membrane manufacturer, under the anchor bar.
3.4
PROTECTION
A.
Protect installed products until completion of project.
B.
Touch-up, repair or replace damaged products before Substantial Completion.
3.5
SCHEDULES
 
** NOTE TO SPECIFIER ** Retain Paragraph below if required to suit project requirements. Identify products by name on the Drawings or use this paragraph to define the location of each type of material to be used. The following are some examples of schedule references. Edit as required to suit project or delete and identify products on the Drawings.
 
A.
:
1.
2.
3.
B.
:
1.
2.
3.