| 1. Configure COLD FORMED STEEL FRAMING: |
| FRAMING MATERIALS |
| | A. Framing Components: |
 | | | | Wall Framing: |
 | | | | Floor Framing |
| | | | Framing Size, Shape, & Gauge: |
| | | | | Design Uncoated-Steel Thickness: 27 mil (22 gauge), .0283 in (0.72 mm) |
| | | | | Design Uncoated-Steel Thickness: 33 mil (20 gauge), .0346 in (0.88 mm) |
| | | | | Design Uncoated-Steel Thickness: 43 mil (18 gauge), .0451 in (1.15 mm) |
| | | | | Design Uncoated-Steel Thickness: 54 mil (16 gauge), .0566 in (1.44 mm) |
 | | B. Roof Trusses: NUTRUSS(TM) Pre-Engineered Cold-Formed Steel Truss System |
| | | | Chords and Webs: |
| | | | | Nominal 27 mil (22 gauge) members |
| | | | | Nominal 33 mil (20 gauge) members |
| | | | | Nominal 43 mil (18 gauge) members |
| | | | | Nominal 54 mil (16 gauge) members |
| | | | Fabricate Straight, Level, & True, without Racking or Twisting, and to Following Tolerances: |
| | | | | Trusses up to 30 feet long: Max 1/2 in (12.5 mm) variation from design |
| | | | | Trusses over 30 feet long: Max 3/4 in (19 mm) variation from design |
| | | | | Trusses up to 5 feet high: Max 1/4 in (6 mm) variation from design |
| | | | | Trusses over 5 feet high: Max 1/2 in (12.5 mm) variation from design |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |