| 1. Configure Epro Services HIGH PERFORMANCE WATERPROOFING: |
| WATERPROOFING SYSTEMS |
| NOTE: Select the systems below that apply to the project. If more than 1 system with the same name is required, |
| edit the names to indicate where each is to be used. |
| | A. Blindside/Lagging Walls: |
 | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | Second Course: Polyethylene drainage panel applied directly to lagging surface. |
 | | | Third Course: High performance fluid-applied membrane waterproofing. |
| | | Fourth Course: Shotcrete, as specified in Section 03371. |
| | B. Blindside/Shotcrete and Soil Nails: |
| | | First Course: Shotcrete, with weepholes extending into drainage panel; as specified in Section 03371. |
 | | | Second Course: Polyethylene drainage panel applied directly to Shotcrete surface. |
 | | | Third Course: High performance fluid-applied membrane waterproofing. |
| | | Fourth Course: Shotcrete, as specified in Section 03371. |
| | C. Blindside/Soil Nails and Earth: |
 | | | First Course: Polyethylene drainage panel applied directly to soil surface. |
 | | | Second Course: High performance fluid-applied membrane waterproofing. |
| | | Third Course: Shotcrete, as specified in Section 03371. |
| | D. Blindside/Sheet Piling: |
| | | First Course: Sheet Piling. |
 | | | Second Course: Polyethylene drainage panel applied directly to Sheet Piling surface. |
 | | | Third Course: High performance fluid-applied membrane waterproofing. |
| | | Fourth Course: Shotcrete, as specified in Section 03371. |
| | E. Underground Structures, Including Tunnels - Top/Outside Waterproofing: |
 | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | Second Course: Polyethylene geomembrane, 10 mils thickness. |
 | | | Third Course: Polyethylene drainage panel. |
| | F. Foundation Wall Assemblies: |
| | | Please Select Only 1 of the Following Foundation Walls. |
| | | | Foundation Walls NOT More Than 12 ft (3660 mm) Below Grade: |
 | | | | First Course: Standard duty fluid-applied membrane waterproofing |
 | | | | Second Course: Polyethylene drainage panel. |
| | | | Foundation Walls: |
 | | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | | Second Course: Polyethylene geomembrane. |
| | | | Third Course for Vertical Structures: |
| | | | Foundation Walls: |
 | | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | | Second Course: Polyethylene geomembrane. |
| | | | Third Course: Rigid insulation, as specified in Section 07212. |
| | | | Fourth Course for Vertical Structures: |
| | G. Planters - Concrete and Concrete Masonry: |
 | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | Second Course: |
| | | Third Course: |
| | | Finish Course: Planting soil, as specified elsewhere |
| | H. Slab-On-Grade - Waterproofing Under Slab: |
| | | Subbase: Sand over rough grade; as specified in Section 02316. |
| | | First Course: Reinforcing/Barrier sheet, fabric side down. |
 | | | Second Course: High performance fluid-applied membrane waterproofing. |
| | | Third Course: Reinforcing/Barrier sheet, fabric side up. |
| | | Finish Course: Concrete Slab as indicated in drawing. |
| | I. Slab-On-Grade - Methane Barrier/Waterproofing Under Slab: |
| | | Subbase: Sand over rough grade; as specified in Section 02316. |
 | | | First Course: Polyethylene geomembrane, 10 mils thickness. |
 | | | Second Course: High performance fluid-applied membrane waterproofing. |
 | | | Third Course: Polyethylene geomembrane, 10 mils thickness. |
| | J. Slab-On-Grade - Mud Slab Construction: |
 | | | First Course on Top of Mud Slab: High performance fluid-applied membrane waterproofing. |
| | | Second Course: Reinforcing/Barrier sheet, fabric side up. |
| | | Finish Course: Concrete slab as indicated on drawings. |
| | K. Concrete Plaza Decks - For Pervious Paving: |
| | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | Second Course: Polyethylene geomembrane, minimum 15 mils thickness. |
| | | Third Course: |
| | | Finish Course: Paving as specified elsewhere. |
| | L. Concrete Decks: |
| | | | Bonded Finish: (For Tile or Terrazzo That is to be Bonded to Deck) |
 | | | | First Course: High performance fluid-applied membrane waterproofing. |
| | | | Second Course: Reinforcing/barrier sheet, fabric side up. |
| | | | Finish Course: As specified elsewhere. |
| | | | Unbonded Finish: (For Cleavage Membrane) |
 | | | | First Course: High performance fluid-applied membrane waterproofing. |
 | | | | Second Course: Polyethylene geomembrane, minimum 15 mils thickness. |
| | | | Finish Course: As specified elsewhere. |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |