1. For indicating different thicknesses for the same material in different locations:
Applications 
2. Select and Configure Materials:
Rigid board glass fiber thermal insulation:
 
Select THICKNESS AND R-VALUE (if more than one, indicate where used)
1-inch (25 mm): R-value of 4.31-1/2-inch (38 mm): R-value of 6.5
2 inch (51 mm): R-value of 8.72-1/2inch (64 mm): R-value of 10.9
3 inch (76 mm): R-value of 13.03-1/2inch (89 mm): R-value of 15.2
4 inch (102 mm): R-value of 17.4
Foil-faced glass fiber thermal insulation - batt type:
Select THICKNESS (if more than one, indicate where used)
3-1/2 inch (89 mm): R-value of 113-1/2 inch (89 mm): R-value of 13
6-1/4 inch (159 mm): R-value of 1910 inch (254 mm): R-value of 30
12 inch (305 mm): R-value of 38 (only with FSK-25 facing)
Kraft faced glass fiber thermal insulation - batt type:
Select THICKNESS AND R-VALUE (if more than one, indicate where used)
3-1/2 inch (89 mm): R-value of 113-1/2 inch (89 mm): R-value of 13 (high density)
3-1/2 inch (89 mm): R-value of 15 (high density)5-1/2 inch (140 mm): R-value of 21 (high density)
6-1/4 inch (159 mm): R-value of 196-1/2 inch (165 mm): R-value of 22
8-1/4 inch (210 mm): R-value of 30 (high density)9 inch (229 mm): R-value of 26
10 inch (254 mm): R-value of 3010-1/4 inch (261 mm): R-value of 38
12 inch (305 mm): R-value of 38
Unfaced glass fiber thermal insulation - batt type:
Select THICKNESS AND R-VALUE (if more than one, indicate where used)
3/4 inch (19 mm): R-value of 3 - for use between furring strips on solid walls1-1/2 inch (38 mm): R-value of 5- for use between furring strips on solid walls
3-1/2 inch (89 mm): R-value of 113-1/2 inch (89 mm): R-value of 13 (high density)
3-1/2 inch (89 mm): R-value of 15 (high density)5-1/2 inch (140 mm): R-value of 21 (high density)
6-1/4 inch (159 mm): R-value of 196-1/2 inch (165 mm): R-value of 22
8-1/4 inch (210 mm): R-value of 30 (high density)8-1/2 inch (216 mm): R-value of 25
9 inch (229 mm): R-value of 2610 inch (254 mm): R-value of 30
10-1/4 inch (261 mm): R-value of 38 (high density)12 inch (305 mm): R-value of 38
Extra wide glass fiber thermal insulation for surface application - batt type:
 
Select THICKNESS AND R-VALUE (if more than one, indicate where used)
3-1/2 inch (89 mm): R-value of 11
6 inch (159 mm): R-value of 19
Accoustical glass-fiber insulation: batt type 
Black accoustical glass fiber insulation: batt type 
Black accoustical glass fiber insulation: board type 
Blown insulation
3. Installation - Batts, blankets, and boards:
Surface application 
Between metal studs, rafters and joists 
Between wood studs, rafters and joists 
4. When you are finished makeing selections:
  Generate Spec: Word     WP   or   RTF