| 1. Configure POLYISOCYANURATE ROOF INSULATION - Insulation: |
| PRODUCTS: |
 | | Roof Board Insulation: Provide products that comply with the following: |
| | | ASTM standards specified |
| | | Factory Mutual (FM) approvals specified |
| | | Underwriters Laboratories 1nc. (UL) classifications specified |
| | | Florida Building Code Approval FL#1296 |
| | | Miami Dade County, Florida Product Control No. 04-1018.01 |
 | | Felt-Faced Foam Roof Insulation: Flat H-Shield |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | R Value: Provide Insulation with LTTR (Long Term Thermal Resistance) in accordance with ASTM C 1289, Annex A1. Minimum thickness of panels shall be as follows: |
| | | | | Thickness 1.00 inch (25 mm), R Value 6.00, flute spanability 2 5/8 inches (67 mm) |
| | | | | Thickness 1.50 inch (38 mm), R Value 9.00, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.60 inch (41 mm), R Value 9.60, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.70 inch (43 mm), R Value 10.30, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.80 inch (46 mm), R Value 10.90, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.00 inch (51 mm), R Value 12.10, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.50 inch (64 mm), R Value 15.30, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.70 inch (69 mm), R Value 16.60, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.00 inch (76 mm), R Value 18.50, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.10 inch (79 mm), R Value 19.10, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.30 inch (84 mm), R Value 20.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.50 inch (89 mm), R Value 21.70, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.60 inch (91 mm), R Value 22.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.70 inch (94 mm), R Value 23.00, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 4.00 inch (102 mm), R Value 25.00, flute spanability 4-3/8 inches (111.13 mm) |
 | | Flat Foil-Faced Foam Roof Insulation: H-Shield-F |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | R Value: Provide Insulation with LTTR (Long Term Thermal Resistance) in accordance with ASTM C 1289, Annex A1. Minimum thickness of panels shall be as follows: |
| | | | | Thickness 1.00 inch (25 mm), R Value 6.00, flute spanability 2 5/8 inches (67 mm) |
| | | | | Thickness 1.50 inch (38 mm), R Value 9.00, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.80 inch (46 mm), R Value 10.90, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.00 inch (51 mm), R Value 12.10, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.50 inch (64 mm), R Value 15.30, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.00 inch (76 mm), R Value 18.50, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.30 inch (84 mm), R Value 20.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.50 inch (89 mm), R Value 21.70, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.60 inch (91 mm), R Value 22.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 4.00 inch (102 mm), R Value 25.00, flute spanability 4-3/8 inches (111.13 mm) |
 | | Flat Foam Roof Insulation with Coated Glass Facers: Flat H-Shield-CG |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | Slope of tapered board: |
 | | Flat Foam Roof Insulation with Coated Glass Facer: Flat H-Shield-DWD |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108): |
| | | | UL 263 (ASTM E 119) |
| | | Compressive Strength: |
| | | R Value: Provide Insulation with LTTR (Long Term Thermal Resistance) in accordance with ASTM C 1289, Annex A1. Minimum thickness of panels shall be as follows: |
| | | | | Thickness 1.00 inch (25 mm), R Value 6.00, flute spanability 2 5/8 inches (67 mm) |
| | | | | Thickness 1.50 inch (38 mm), R Value 9.00, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.60 inch (41 mm), R Value 9.60, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.70 inch (43 mm), R Value 10.30, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 1.90 inch (48 mm), R Value 11.50, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.00 inch (51 mm), R Value 12.10, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.50 inch (64 mm), R Value 15.30, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.70 inch (69 mm), R Value 16.60, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.00 inch (76 mm), R Value 18.50, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.10 inch (79 mm), R Value 19.10, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.30 inch (84 mm), R Value 20.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.50 inch (89 mm), R Value 21.70, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.60 inch (91 mm), R Value 22.40, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 4.00 inch (102 mm), R Value 25.00, flute spanability 4-3/8 inches (111.13 mm) |
 | | Foam Roof Insulation Bonded to Wood Fiberboard: H-Shield-WF |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | R Value: Provide Insulation with LTTR (Long Term Thermal Resistance) in accordance with ASTM C 1289, Annex A1. Minimum thickness of panels shall be as follows: |
| | | | | Thickness 1.50 inch (38 mm), R Value 7.36, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.00 inch (51 mm), R Value 10.36, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 2.50 inch (64 mm), R Value 13.46, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.00 inch (76 mm), R Value 16.66, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.10 inch (79 mm), R Value 17.26, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.40 inch (86 mm), R Value 19.26, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 3.50 inch (89 mm), R Value 19.86, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 4.00 inch (102 mm), R Value 23.06, flute spanability 4-3/8 inches (111.13 mm) |
| | | | | Thickness 4.50 inch (113 mm), R Value 26.36, flute spanability 4-3/8 inches (111.13 mm) |
 | | Tapered Foam Roof Insulation with Fiber-Reinforced Facers: Tapered H-Shield |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | Slope of tapered board: |
 | | Tapered Foam Roof Insulation with Coated Glass Facers: Tapered H-Shield-CG |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | Slope of tapered board: |
 | | Tapered Foam Roof Insulation Bonded to Wood Fiberboard: Tapered H-Shield-WF |
| | | Blowing Agent: Zero ODP, 3rd generation |
| | | Fire Ratings: |
| | | | UL 1256, No. 120 and 123 |
| | | | UL 790 (ASTM E 108), Class A |
| | | | UL 263 (ASTM E 119) |
| | | | FM 4450/4470, Class 1. Fire Rating |
| | | FM Approval: |
| | | Compressive Strength: |
| | | Slope of tapered board: |
| EXECUTION: |
| | Built-Up, Coal Tar and Modified Bitumen Systems: |
| | | Secure each H-Shield panel to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type) |
| | | Adhere maximum 4 foot by 4 foot (1220 mm by 1220 mm) panels of H-Shield to a prepared concrete deck with a full mopping of hot steep asphalt |
| | | Adhere maximum 4 foot by 4 foot (1220 mm by 1220 mm) panels of H-Shield to a prepared concrete deck with FM approved cold adhesive |
| | | Multi Layer System: |
| | | In multi-layer installations, stagger joints in top and bottom layers. Do not align joints in insulation |
| | | Install the roof covering according to the roof manufacturer's specifications |
| | Single-Ply Systems Ballasted Single-Ply Systems: |
| | | Each H-Shield panel is loosely laid on the roof deck |
| | | Butt edges and stagger joints of adjacent panels |
| | | Install the roof covering according to the roof manufacturer's specifications |
| | Mechanically Attached Single-Ply Systems: |
| | | Each H-Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type) |
| | | Butt edges and stagger joints of adjacent panels |
| | | Install the roof covering according to the roof manufacturer's specifications |
| | Fully Adhered Single-Ply Systems: |
| | | Secure each H-Shield panel to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type) |
| | | Adhere maximum 4 foot by 4 foot (1220 mm by 1220 mm) panels of H-Shield to a prepared concrete deck with a full mopping of hot steep asphalt |
| | | Adhere maximum 4 foot by 4 foot (1220 mm by 1220 mm) panels of H-Shield to a prepared concrete deck with FM approved cold adhesive |
| | | Multi Layer System: |
| | | In multi-layer installations, stagger joints in top and bottom layers. Do not align joints in insulation |
| | | Install the roof covering according to the roof manufacturer's specifications |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |