| 1. Configure Green River Inc. - Underlayment: |
| | PERFORMANCE REQUIREMENTS: |
 | | Fire Rating: |
 | | | CedarPlus CCA Preservative Treatment, .40 retention |
| | ROOF BOARD: |
| | | Gypsum Sheathing: 1/4 inch (6mm) overlay board with a water-resistant and silicone treated gypsum core with glass fiber facers embedded on both sides |
| | | Cap Sheet Underlayment: 72lb mineral surface cap sheet conforming to ASTM D 3909 |
 | | UNDERLAYMENT: |
| | | Leak Barrier Membrane: Self-adhering bituminous membrane meeting or exceeding the requirements of ASTM D 1970 |
| | Felt Underlayment: |
| | ** NOTE ** Interlayment is required on shake products. Interlayment is not recommended with shingle products |
| | | Felt Interlayment: 18-inch wide roofing felt, 30 Lb Organic asphalt saturated felt meeting or exceeding the requirements of ASTM D 226 or ASTM D 4869 Type II |
 | | SHAKES: |
| | Handsplit and Resawn Shakes: |
| | | Length: |
| | | Thickness: |
| | | Exposure: |
| | Taper-Sawn Shakes: |
| | | Length: |
| | | Thickness: |
| | | Exposure: |
 | | SHINGLES: |
| | Green River "Reserve" Grade: Number 1; Clear heartwood, 100 percent edge grain: |
| | | Exposure: |
| | SHEET METAL |
| | Material: |
| | | Fabrication: |
| | | | Valley Flashing: 24 inch (610mm) wide metal fabrication with a 1 inch (25mm) raised splash diverter at the flow line |
| | | | Step Flashing: 9 inch (228mm) wide metal fabrication with a 5 inch (127mm) leg up the wall and a 4 inch (102mm) leg under the shake |
| | | | Headwall Flashing: 8 inch (203mm) wide metal fabrication with two 4 inch (102mm) legs |
| | | | Eaves and Rake Drip Edge: 8 inch (203mm) wide metal fabrication. Profile as noted in the Contract Drawings |
| | | | ** NOTE ** Select plumbing vent flashing type |
| | | | Molded flashing with a self sealing santoprene boot. Material to match field fabricated flashings |
| | | | Soldered metal flashing formed to return into plumbing stack. Material to match field fabricated flashings |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |