1. Configure Green River Inc. - Underlayment:
PERFORMANCE REQUIREMENTS:
Fire Rating:
CedarPlus CCA Preservative Treatment, .40 retention
ROOF BOARD:
Gypsum Sheathing: 1/4 inch (6mm) overlay board with a water-resistant and silicone treated gypsum core with glass fiber facers embedded on both sides
Cap Sheet Underlayment: 72lb mineral surface cap sheet conforming to ASTM D 3909
UNDERLAYMENT:
Leak Barrier Membrane: Self-adhering bituminous membrane meeting or exceeding the requirements of ASTM D 1970
Felt Underlayment:
** NOTE ** Interlayment is required on shake products. Interlayment is not recommended with shingle products
Felt Interlayment: 18-inch wide roofing felt, 30 Lb Organic asphalt saturated felt meeting or exceeding the requirements of ASTM D 226 or ASTM D 4869 Type II
SHAKES:
Handsplit and Resawn Shakes:
Length:
Thickness:
Exposure:
Taper-Sawn Shakes:
Length:
Thickness:
Exposure:
SHINGLES:
Green River "Reserve" Grade: Number 1; Clear heartwood, 100 percent edge grain:
Exposure:
SHEET METAL
Material:
Fabrication:
Valley Flashing: 24 inch (610mm) wide metal fabrication with a 1 inch (25mm) raised splash diverter at the flow line
Step Flashing: 9 inch (228mm) wide metal fabrication with a 5 inch (127mm) leg up the wall and a 4 inch (102mm) leg under the shake
Headwall Flashing: 8 inch (203mm) wide metal fabrication with two 4 inch (102mm) legs
Eaves and Rake Drip Edge: 8 inch (203mm) wide metal fabrication. Profile as noted in the Contract Drawings
** NOTE ** Select plumbing vent flashing type
Molded flashing with a self sealing santoprene boot. Material to match field fabricated flashings
Soldered metal flashing formed to return into plumbing stack. Material to match field fabricated flashings
  2. When you are finished making selections:
  Generate Spec: Word     WP   or   RTF