| 1. Configure Westlake Royal Roofing Solutions - Concrete Roof Tile: |
|
| 
| CONCRETE ROOF TILE - ARIZONA
|
|
|
|
| 
| CONCRETE ROOF TILE - FLORIDA, SOUTHEAST, NORTHEAST
|
|
|
|
| 
| CONCRETE ROOF TILE - HAWAII
|
|
|
|
| 
| CONCRETE ROOF TILE - NORTHERN CALIFORNIA AND PACIFIC NORTHWEST
|
|
|
|
| 
| CONCRETE ROOF TILE - ROCKY MOUNTAIN, HEARTLAND
|
|
|
|
| 
| CONCRETE ROOF TILE - SOUTHERN CALIFORNIA
|
 |
| |
|
 SOUTHERN CALIFORNIA TILE
|
|
| | |
|
 SOUTHERN CALIFORNIA ROOF SYSTEM COMPONENTS
|
 |
|
|
|
|
Underlayment: |
|
| |
|
|
Fasteners: Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten. |
| |
|
|
|
Quik Drive Screws, Roofing Specific |
|
|
| |
|
|
Wind Clips: Zip-Clip, Adjustable Tile Clip |
|
| |
|
|
Flashings: |
| |
|
|
|
Ribbed Tile Pan, 26-gauge Galvanized Sheet Steel side wall flashing |
| |
|
|
|
Wakaflex universal flashing for abutments at chimneys, walls and other rising structures |
| |
|
|
|
Terminal Bar metal flashing for chimneys and other roof to wall structures |
| |
|
|
|
Ribbed Valley Metal 1 inch Center Diverter, 26 gauge, Galvanized Sheet Steel |
| |
|
|
|
Plumbing Stacks and Other Pipes Penetrating Roof: Wakaflex Pipe Flashing |
|
| |
|
|
Adhesive: Code approved adhesive suitable to bond to concrete roof tile. |
|
|
| |
|
|
Eave Closures: |
| |
|
|
Note: Eave Closures apply to Standard Weight Westlake Royal Roofing Madera and Lightweight Cedarlite tile only. |
| |
|
|
|
Vented Eave Riser - Metal |
| |
|
|
|
Eave Riser - Metal |
| |
|
|
|
Eave Closure "T" - Metal |
|
| |
|
|
Battens: |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 8 feet (2.44 m) pressure treated |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 8 feet (2.44 m) |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 8 feet (2.44 m) |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 4 feet (1.22 m). Fire Retardant Treated |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 4 feet (1.22 m). Fire Retardant Treated |
| |
|
|
|
FirePro Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 4 feet (1.22 m). Fire Retardant Treated |
| |
|
|
|
FirePro Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 4 feet (1.22 m). Fire Retardant Treated |
| |
|
|
|
Batten Extenders 18 inches (457 mm) for use with standard battens |
|
|
| |
|
|
Hip and Ridge: |
| |
|
|
|
Figaroll Plus: Ridge vent and weather block for all profiles |
| |
|
|
|
Zephyr Roll: Ridge vent and weather block flat tiles, 11 inches by 33 feet (279 mm by 10 M) |
| |
|
|
|
Zephyr Roll: Ridge vent and weather block, 13.4 inches by 33 feet (340 mm by 10 M). For medium and high-profile tiles |
| |
|
|
|
Ridge Riser: Elevates ridge board to proper height. For all profiles. For use with Figaroll Plus or Zephyr Roll |
|
|
| |
|
|
Ridge, Rake and Gable End Tiles: |
| |
|
|
|
Choose to match tile profile and color. |
| |
|
|
Note: The following two paragraphs apply to Standard Weight Westlake Royal Roofing Madera, Cedarlite and Saxony tiles only. |
| |
|
|
|
Metal Rake Trim |
| |
|
|
|
Gable End Rubber Wedges |
|
| |
|
|
Field Venting Select to match profile of concrete roof tile |
|
|
|
| 
| CONCRETE ROOF TILE - SOUTHERN NEVADA
|
|
|
|
| 
| CONCRETE ROOF TILE - TEXAS
|
 |
| |
|
 TEXAS TILE
|
|
| | |
|
 TEXAS ROOF SYSTEM COMPONENTS
|
 |
|
|
|
|
Underlayment: |
|
| |
|
|
Fasteners: Sized to penetrate deck minimum 3/4 inch (19 mm) or through thickness of deck or batten |
| |
|
|
|
Quik Drive Screws, Roofing Specific |
|
|
| |
|
|
Wind Clips: |
| |
|
|
|
Zip-Clip, Adjustable Tile Clip |
| |
|
|
|
Wind Clips, Galvanized |
|
| |
|
|
Flashings: |
| |
|
|
|
Ribbed Tile Pan, 26-gauge Galvanized Sheet Steel side wall flashing |
| |
|
|
|
Wakaflex universal flashing for abutments at chimneys, walls and other rising structures |
| |
|
|
|
Terminal Bar metal flashing for chimneys and other roof to wall structures |
| |
|
|
|
Ribbed Valley Metal 1 inch Center Diverter, 26 gauge, Galvanized Sheet Steel |
| |
|
|
|
Plumbing Stacks and Other Pipes Penetrating Roof: Wakaflex Pipe Flashing |
|
|
| |
|
|
Adhesive: Code approved adhesive suitable to bond to concrete roof tile. |
|
| |
|
|
Eave Closures: To match tile profile |
| |
|
|
|
Vented Eave Riser - Metal (Only available with Standard Weight Madera) |
| |
|
|
|
Eave Riser - Metal (Only available with Standard Weight Madera) |
| |
|
|
|
Eave Closure "T" - Metal. For flat tiles only |
|
|
| |
|
|
Battens: |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 3 inches (76 mm) by 8 feet (2.44 m) |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 8 feet (2.44 m) |
| |
|
|
|
Elevated Batten System 1 inch (25 mm) by 2 inches (51 mm) by 4 feet (1.22 m) |
| |
|
|
|
Batten Extenders 18 inches (457 mm) for use with standard battens |
|
| |
|
|
Hip and Ridge: |
| |
|
|
|
Figaroll Plus: Ridge vent and weather block for all profiles |
| |
|
|
|
Zephyr Roll: Ridge vent and weather block flat tiles, 11 inches by 33 feet (279 mm by 10 M) |
| |
|
|
|
Zephyr Roll: Ridge vent and weather block, 13.4 inches by 33 feet (340 mm by 10 M). For medium and high-profile tiles |
| |
|
|
|
Ridge Riser: Elevates ridge board to proper height. For all profiles. For use with Figaroll Plus or Zephyr Roll |
|
|
| |
|
|
Ridge, Rake and Gable End Tiles: |
| |
|
|
|
Choose to match tile profile and color. |
| |
|
|
|
Gable End Rubber Wedges. (Applicable only to Standard Weight Madera) |
|
| |
|
|
Field Venting Select to match profile of concrete roof tile |
|
|
| 2. When you are finished making selections: |
| Generate Spec: Word - US
Word - Canadian
WP - US
RTF - US
|