| 1. Configure Steel Door Institute - STEEL DOORS AND FRAMES: |
 | Frames |
| | Interior Frames: |
| | | Level 1 Standard Duty-Use With: |
| | | Level 2 Heavy Duty-Use With: |
| | | Level 3 Extra Heavy-Duty-Use With: |
| | Exterior Frames: |
| | | Level 1 Standard Duty-Use With: |
| | | Level 2 Heavy Duty-Use With: |
| | | Level 3 Extra Heavy-Duty-Use With: |
| | | Level 4 Maximum-Duty-Use With: |
| | Note: If Galvanized Frames are Required, Select One of the Two Following Methods of Indication for Location |
| | Provide units of galvanized steel where indicated on the door schedule |
| | Provide units of galvanized steel in the following locations |
| | | Exterior openings, as noted on door schedule |
| | | Kitchens, as noted on door schedule |
| | | Toilets, as noted on door schedule |
| | | Washrooms, as noted on door schedule |
| | | Locker rooms, as noted on door schedule |
| | | Showers, as noted on door schedule |
| | | Laboratories, as noted on door schedule |
| | Frame Construction: |
| | Slip-on drywall frame anchors shall be as provided by the manufacturer to assure performance specified |
| | Borrowed or Sidelights Required - Provide glazing stops and beads where glazed lights are indicated |
 | Doors |
| | Interior Doors: |
| | | Level 1 - Standard Duty 1-3/8 inches (34.9 mm): |
| | | Level 1 - Standard Duty 1-3/4 inches (44.5 mm): |
| | | Level 2 - Heavy Duty 1-3/4 inches (44.5 mm): |
| | | Level 3 - Extra Heavy-Duty 1-3/4 inches (44.5 mm): |
| | | Level 4 - Maximum-Duty 1-3/4 inches (44.5 mm): |
| | Exterior Doors: |
| | | Level 1 - Standard Duty 1-3/8 inches (34.9 mm): |
| | | Level 1 - Standard Duty 1-3/4 inches (44.5 mm): |
| | | Level 2 - Heavy Duty 1-3/4 inches (44.5 mm): |
| | | Level 3 - Extra Heavy-Duty 1-3/4 inches (44.5 mm): |
| | | Level 4 - Maximum-Duty 1-3/4 inches (44.5 mm): |
| | Decorative Door Faces: Provide textured or embossed steel faces as indicated |
| | Face steel sheet shall meet at least one or more of the following requirements: |
| | | Level 1: |
| | | Level 2: |
| | | Level 3: |
| | | Level 4: |
| | End Closure: |
| | Provide louvers and vision lites where indicated on the Drawings in accordance with ANSI/SDI A250.8 |
| | Provide steel astragals where indicated on the Drawings or where required by the manufacturer or NFPA 80 |
 | Fabrication |
| | Factory Applied Finish: Meet performance requirements & acceptance criteria as stated in ANSI/SDI A250.3. |
| | Color shall be: |
| | Design Clearances: Fabricate doors and frames to maintain the following clearances |
| | | Clearance at the Bottom: |
 | Quality Assurance |
| | Fire Rated Doors & Frames: Ratings as indicated on Door Schedule, when tested in accordance with NFPA 252, UL 10B or UL 10C |
| | | Stairwell Doors: 250 deg F (121 deg C) or 450 deg F (232 deg C) temp rise rating as well as the required fire rating |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |