1. Configure Lawler Manufacturing Co. - THERMOSTATIC WATER MIXING VALVES:
Domestic Water Mixing Valves
Point-of-Use Thermostatic Mixing Valve: Lawler TMM-1000, ASSE 1016 Approved
Capacity: 2 gpm (8 lpm) at 50 psi (345 kPa) pressure drop; min flow 1/2 gpm (2 lpm) ;
              min operating pressure 10 psi (38 kPa) pressure drop
Under-the-Counter Thermostatic Mixing Valves: Master Controller
Capacity:
 
Finish: 
Cabinet: 
Under-the-Counter Thermostatic Mixing Valve: Lawler Model 516
Capacity: 10 gpm (38 lpm) at 45 psi (310 kPa) pressure drop; 3 gpm (11 lpm) at 5 psi (34 kPa) pressure drop
Cabinet: 
Point of Use Concealed Thermostatic Mixing Valves: Lawler 3000/7000
Series: 
Capacity: 
Finish: 
Faceplate: 
Cabinet for Detention Shower
Accessories:
Hand Spray: 
Stops: Shower Head: 
Tub Spout: Handle: 
Diverter Valve: V1Dial Thermometer: 
Point of Use Exposed Thermostatic Mixing Valves: Lawler 4000 Series
Capacity: 
Finish: 
Cabinet: 
Accessories:
Handle: ADA Compliant LeverHandle: Vandal Resistant
Volume ControlVacuum Breaker
Dial ThermometerUnion End Stop & Check Valves
Shut-Off ValveWashout Hose
Hose Hook
Master Controller (Small) Thermostatic Mixing Valve: Lawler Model 517
Capacity: 18 gpm (68 lpm) at 45 psi (310 kPa) pressure drop; 8 gpm (19 lpm) at 10 psi (69 kPa) pressure drop
Cabinet: 
Master Controller (Small to Medium) Thermostatic Mixing Valves:
Capacity:
 
Finish: 
Cabinet: 
Accessories:
Dial ThermometerCold Water Bypass Line from Cold Water Supply Line
Shut-Off on OutletVacuum Breaker on Outlet
Provide dual-tempered outletsProvide solenoid on tempered water outlet
Provide shock absorber on tempered water outletProvide wall bracket
Provide vandal-resistant handle screw
Temperature range:
Master Controller (Medium to Large) Thermostatic Mixing Valves:
Capacity:
 
Finish: 
Cabinet: 
Accessories:
Dial ThermometerCold Water Bypass Line from Cold Water Supply Line
Shut-Off on OutletVacuum Breaker on Outlet
Provide dual-tempered outletsProvide solenoid on tempered water outlet
Provide shock absorber on tempered water outletProvide wall bracket
Provide vandal-resistant handle screw
Temperature range:
Master Controller (High/Low) Thermostatic Mixing Valves:
Capacity:
 
Pre-piped System: 
Finish: 
Cabinet: 
Accessories:
Dial ThermometerCold Water Bypass Line from Cold Water Supply Line
Shut-Off on OutletVacuum Breaker on Outlet
Provide dual-tempered outletsProvide solenoid on tempered water outlet
Provide shock absorber on tempered water outletProvide wall bracket
Provide vandal-resistant handle screw
Temperature range:
Manifold Recirculation System: High/Low Thermostatic Mixing Valve
Capacity:
 
Accessories:
1/2 inch (12.5 mm) Return Line3/4 inch (19 mm) Return Line
1 inch (25 mm) Return LineAquastat on Return line
Circulator Power SwitchHigh Temperature Audio-Visual Alarm
Recirculating Pump
Master Controller Thermostatic Mixing and Pressure Balanced Valves
Capacity:
 
Finish: 
Cabinet: 
Accessories:
Outlet ThermometerShut-Off Valve On Outlet
Vacuum Breaker on OutletTwo Tempered Water Outlets
Temperature range:
Emergency Application Water Mixing Valves
Master Controller Thermostatic Mixing Valves For Multiple Drench Emergency Showers: Lawler 911 Series
Finish: 
Cabinet: 
Shut-Offs on Inlets
Provide checks on inlets
Provide mounting bracket
Point of Use Thermostatic Mixing Valves For Single Drench Emergency Showers & Eye Washes: Lawler 911 E Series
Finish: 
Cabinet: 
Shut-Offs on Inlets
Provide checks on inlets
Provide mounting bracket
Point of Use Thermostatic Mixing Valves For Single Drench Emergency Eye & Face Washes: Lawler 911 E/F Series
Finish: 
Cabinet: 
Shut-Offs on Inlets
Check Valves on Inlets
Emergency Tempering System For Combination Emergency Shower And Eyewash Equipment
Emergency Tempering System consists of a 119 gallon water heater storage tank and 120V 20AMP heating element
Provide Emergency Equipment.
Provide expansion tank.
Provide cold water filter.
Photographic Processing Water Mixing Valves
Thermostatic Mixing Valves For Photographic Processing and X-Ray Developing
Note: Only One of the Following Three Thermostatic/Pressure-Balanced Valves May Be Selected
Thermostatic Valve (9200 - Compact Size): 
Thermostatic Valve (9600 - Flange Mount): 
Thermostatic & Pressure Balanced Valve (9700): 
Finish: 
Filter Pack: Including filter casing, input/output pressure gages, and replaceable micron filter tube
Flow Meter: Marked at 1/2 (2 lpm) and 5 gpm (18 lpm) increments
Thermometer: Straight stem; rigid chrome plated body, white 4 inch (102 mm) dial face;
                     40 to 140 degree F (4 to 60 degrees C) range
Thermometer: Remote; white 4 inch (102 mm) dial face; 40 to 140 degree F (4 to 60 degrees C) range;
                     including sensor and 5 foot (1525 mm) capillary line
 2. When you are finished making selections:
  Generate Spec: Word     WP   or   RTF