| 1. Configure Thomas and Betts Corp - Raceways and Boxes: |
 | | FLUSH SERVICE FLOOR BOXES |
| | | General: Flush service floor boxes for multiple services shall deliver power and communications cable, from the same device |
| | | | When hinged cover is closed and no services in place, device shall have no obstructions above surface of floor |
| | | | Cover assembly shall protect against the ingress of water and foreign material with a gasket and shall meet UL scrubwater exclusion requirements |
| | | Device plates, faceplates and trims as scheduled or as required as manufactured by Thomas and Betts Corp. Refer to Materials Finish Schedule |
| | | Round Flush Service Floor Box Series shall deliver power or communications cable |
 | | | | 68 Series Round Floor Boxes stamped steel with a zinc plating minimum 0.0005 inch (0.0127 mm) thick |
 | | | | 600 Series Round Floor Boxes with cast iron fully adjustable watertight body |
 | | | | 68P Series Round Floor Box fabricated of PVC plastic |
 | | | Rectangular Flush Service Floor Box shall deliver power or communications cable |
| | | | 640 Series Rectangular Floor Boxes with cast iron fully adjustable watertight body (deep) |
| | | | 840 Series Rectangular Floor Boxes with cast iron semi-adjustable watertight body (shallow) |
| | | | 740 Series Series Rectangular Floor Boxes stamped steel with a zinc plating minimum 0.0005 inch (0.0127 mm) thick (shallow & deep) |
| | | | 640P Series Rectangular Floor Box fabricated of Noryl plastic |
| | | Cover Type: SELECT TYPE-------Refer to Drawing General Notes for cover type application requiredPlug cover for N.P.S size as scheduled or requiredDuplex Lift LidHinged Lift LidsGFCI Lift Lid |
| | RECESSED SERVICE FLOOR BOXES |
| | | General: Recessed service boxes for multiple services shall deliver power and communications cable, from the same device |
| | | | When hinged cover is closed and no services in place, device shall have no obstructions above surface of floor |
| | | | Cover assembly shall protect against the ingress of water and foreign material with a gasket and shall meet UL scrubwater exclusion requirements |
| | | Device plates, faceplates and trims as scheduled or as required as manufactured by Thomas and Betts Corp. Refer to the Materials Finish Schedule |
| | | 2 Compartment Recessed Service Floor Boxes with Round Covers: |
 | | | | Cover and Carpet Plate: |
 | | | 2 Compartment Recessed Service Floor Boxes with Rectangular Covers |
| | | | 664-SC Recessed Service Floor Box, stamped steel, standard depth |
| | | | 664-S Recessed Service Floor Box, stamped steel, shallow |
| | | | 664-CI Recessed Service Floor Box, cast iron |
| | | | Covers: |
 | | | 4 Compartment Recessed Service Floor Boxes - Galvanized Steel |
 | | | 4 Compartment Recessed Service Floor Boxes - Cast Iron |
 | | | 4 Compartment Recessed Service Floor Boxes - Ultra-Shallow |
 | | | 4 Compartment Recessed Service Floor Boxes: Each compartment shall accept up to 2 power devices as required |
| | | | Covers: |
 | | | Round Recessed Service Covers for Floor Box Applications |
| | | | Concrete Applications: The 68R covers shall be used with a Steel City 68P round PVC floor box |
| | | | Wood Sub-Floor Applications: The 68R covers shall be used with an appropriate Steel City 3 inches by 2 inches (76 mm by 51 mm) metal switch box with mounting ears |
| | | | Raised Floor Applications: The 68R covers shall be used with an appropriate Steel City 3 inches by 2 inches (76 mm by 51 mm) metal switch box with mounting ears |
| | | | Covers: |
 | | ABOVE-FLOOR SERVICE FITTINGS |
| | | Shall be sized as indicated on drawings or as required by code for size and quantity of conductors |
| | | Shall be brushed aluminum service fitting heads |
| | | Shall deliver electrical power from receptacles as designated on the plans |
| | | Shall deliver telephone/data through precut bushed opening |
| | | Shall be furnished standard with required receptacles |
| | | Shall be furnished standard with conduit nipple for direct screw threading into cover assembly |
| | | Shall be UL listed |
| | FIRE-RATED POKE THROUGH SYSTEMS |
| | | Fire Rating Application: |
| | | | Provide City of Chicago approved base units where scheduled or required for poke through style specified |
| | | | 1-Hour Rated Floor: |
| | | | 2-Hour Rated Floor: |
| | | Provide a flush power and communications poke through for use in a 4 inch (102 mm) hole |
| | | | Cover: |
 | | | | FPT4-4P-4C Flush Poke Through Series as manufactured by Thomas and Betts Corp |
 | | | | FPT4-2P-6C Flush Poke Through Series as manufactured by Thomas and Betts Corp |
 | | | | FPT4-8C Flush Poke Through Series as manufactured by Thomas and Betts Corp |
 | | | | FPT4-1TL-2C Flush Poke Through Series as manufactured by Thomas and Betts Corp |
| | | | Communication Device Plates |
 | | | | Junction Box |
| | | Provide a flush power and/or communications poke through for use in a 3 inch (76 mm) hole |
 | | | | FPT3 Series Flush Poke Through as manufactured by Thomas and Betts Corp |
| | | | | Cover: |
| | | | FPT Series Furniture Feed Poke Through as manufactured by Thomas and Betts Corp |
| | | | | Metallic Cover: Solid brass or aluminum with brushed finish |
| | | | | Cover: |
| | | Provide furniture feed poke through service fitting for use in a 4 inch (102 mm) hole |
 | | | | FFPT4 Series Furniture Feed Poke Through as manufactured by Thomas and Betts Corp |
| | | | Cover: |
| | | Provide furniture feed poke through service fitting for use in a 3 inch (76 mm) hole |
 | | | | FFPT3 Series Furniture Feed Poke Through as manufactured by Thomas and Betts Corp |
| | | | Cover: |
| | | | FPT Series Furniture Feed Poke Through as manufactured by Thomas and Betts Corp |
| | | | Cover: |
| | | Provide an above floor pedestal power and communications poke through service fitting for use in a 3 inches (76 mm) hole |
 | | | | FPT3 Series as manufactured by Thomas and Betts Corp |
| | ACCESS FLOOR MODULES |
| | | Accepts up to 2 power receptacles |
 | | | | AFM-2 as manufactured by Thomas and Betts, Corp |
| | | Accepts up to 3 power receptacles |
 | | | | AFM-4 as manufactured by Thomas and Betts, Corp |
| | | Accepts up to 6 power receptacles |
 | | | | AFM-6 as manufactured by Thomas and Betts, Corp |
| | | Accepts up to 2 power receptacles |
| | | | AFM-6S as manufactured by Thomas and Betts, Corp |
| | | Accepts up to 6 power receptacles |
 | | | | AFM-6V as manufactured by Thomas and Betts, Corp |
| | | Accepts up to 10 power receptacles |
 | | | | AFM-8 as manufactured by Thomas and Betts, Corp |
| | | 3-compartment floor box for raised access floors |
 | | | | AFM-4R Access Floor Module as manufactured by Thomas and Betts, Corp |
| | PRE-SET INSERT |
| | | Pre-Set shall be installed with conduit sizes as shown on the drawings |
 | | | | GAB-4 has standard 3/4 inch (19 mm) conduit thread on power side, in and out |
 | | | | GAB-6 has standard 3/4 inch (19 mm) conduit thread on power side, in and out |
 | | | | GAB-8-S has 3/4 inch (19 mm) KO on power side, in and out. 1-1/4 inches (32 mm) KO on data side, in and out |
 | | | | Pre-set: GAB-4 |
 | | | | Pre-set: GAB-6 |
 | | | | Pre-set: GAB-8-S |
| | | Activation Unit: |
 | | | | 8 inches by 8 inches (203 mm by 203 mm) nominal size steel box (Refer to AFM-4) |
 | | | | 8 inches by 10 inches (203 mm by 254 inches) nominal size steel box (Refer to AFM-6) |
 | | | | 10 inches by 10 inches (254 mm by 254 mm) nominal size steel box (Refer to AFM-8) |
| 2. When you are finished making selections: |
 | Generate Spec: Word WP or RTF |