,Model##Other##,Description##Other##,Unit Width##length##inches,Nozzle Width##length##inches,Unit Depth##length##inches,MAX Opening Height_Environmental Separation##length##feet,MAX Opening Height_Insect Control##length##feet,HVAC_BTU Output##other##,Temperature Rise##other##,Sound Pressure##other##,Fuel Type##other##,Fuel Consumption##other##,Unit Weight##other##,Standards Conformance##other##,Upper Connector##other##,Lower Connector##other## 28in Nozzle Ambient Model,ALC08-1030A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1030A,30,28,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,33,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 35in Nozzle Ambient Model,ALC08-1036A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1036A,37.25,35.25,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,38,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 41in Nozzle Ambient Model,ALC08-1042A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1042A,43.25,41.25,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,43,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 47in Nozzle Ambient Model,ALC08-1048A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1048A,49.25,47.25,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,48,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 59in Nozzle Ambient Model,ALC08-1060A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1060A,61,59,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,57,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 73in Nozzle Ambient Model,ALC08-1072A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-1072A,74.25,72.25,14.4375,8,7,0,0,54 dBA,Ambient Airflow,See Electrical Data,64,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 84in Nozzle Ambient Model,ALC08-2084A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-2084A,86.25,84.25,14.4375,8,7,0,0,57 dBA,Ambient Airflow,See Electrical Data,86,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 96in Nozzle Ambient Model,ALC08-2096A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-2096A,98.25,96.25,14.4375,8,7,0,0,57 dBA,Ambient Airflow,See Electrical Data,96,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 120in Nozzle Ambient Model,ALC08-2120A,Berner Unheated Air Door - Architectural Low Profile 8 Model ALC08-2120A,121.75,119.75,14.4375,8,7,0,0,57 dBA,Ambient Airflow,See Electrical Data,114,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 28in Nozzle Electric Model,ALC08-1030E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1030E,30,28,14.4375,8,0,24600,33,54 dBA,See Electrical Data,See Electrical Data,39,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 35in Nozzle Electric Model,ALC08-1036E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1036E,37.25,35.25,14.4375,8,0,34100,30,54 dBA,See Electrical Data,See Electrical Data,44,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 41in Nozzle Electric Model,ALC08-1042E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1042E,43.25,41.25,14.4375,8,0,34100,26,54 dBA,See Electrical Data,See Electrical Data,49,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 47in Nozzle Electric Model,ALC08-1048E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1048E,49.25,47.25,14.4375,8,0,49100,33,54 dBA,See Electrical Data,See Electrical Data,54,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 59in Nozzle Electric Model,ALC08-1060E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1060E,61,59,14.4375,8,0,49100,27,54 dBA,See Electrical Data,See Electrical Data,63,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 73in Nozzle Electric Model,ALC08-1072E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-1072E,74.25,72.25,14.4375,8,0,68300,30,54 dBA,See Electrical Data,See Electrical Data,70,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 84in Nozzle Electric Model,ALC08-2084E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-2084E,86.25,84.25,14.4375,8,0,68300,26,57 dBA,See Electrical Data,See Electrical Data,98,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 96in Nozzle Electric Model,ALC08-2096E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-2096E,98.25,96.25,14.4375,8,0,98300,33,57 dBA,See Electrical Data,See Electrical Data,108,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 120in Nozzle Electric Model,ALC08-2120E,Berner Electric Heated Air Door - Architectural Low Profile 8 Model ALC08-2120E,121.75,119.75,14.4375,8,0,98300,27,57 dBA,See Electrical Data,See Electrical Data,126,UL Indoors ; Made in USA ; FDA ; USDA,DO NOT connect to any Systems,DO NOT connect to any Systems 28in Nozzle Hot Water Model,ALC08-1030W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1030W,30,28,14.4375,8,0,18800,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,56,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 35in Nozzle Hot Water Model,ALC08-1036W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1036W,37.25,35.25,14.4375,8,0,28100,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,64,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 41in Nozzle Hot Water Model,ALC08-1042W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1042W,43.25,41.25,14.4375,8,0,32800,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,72,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 47in Nozzle Hot Water Model,ALC08-1048W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1048W,49.25,47.25,14.4375,8,0,38500,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,80,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 59in Nozzle Hot Water Model,ALC08-1060W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1060W,61,59,14.4375,8,0,46300,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,95,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 73in Nozzle Hot Water Model,ALC08-1072W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-1072W,74.25,72.25,14.4375,8,0,56800,25,54 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,107,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 84in Nozzle Hot Water Model,ALC08-2084W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-2084W,86.25,84.25,14.4375,8,0,67300,25,57 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,134,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 96in Nozzle Hot Water Model,ALC08-2096W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-2096W,98.25,96.25,14.4375,8,0,76800,25,57 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,150,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 120in Nozzle Hot Water Model,ALC08-2120W,Berner Hot Water Heated Air Door - Architectural Low Profile 8 Model ALC08-2120W,121.75,119.75,14.4375,8,0,95600,26,57 dBA,Hot Water at Specified Temperatures,See Electrical Data and Water Flow Rates,178,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,HW Return,HW Supply 28in Nozzle Steam Model,ALC08-1030S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1030S,30,28,14.4375,8,0,31800,42,54 dBA,Steam at Specified Pressure,See Electrical Data ; 33 lbs / hr of Condensate,56,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 35in Nozzle Steam Model,ALC08-1036S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1036S,37.25,35.25,14.4375,8,0,44400,39,54 dBA,Steam at Specified Pressure,See Electrical Data ; 46 lbs / hr of Condensate,64,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 41in Nozzle Steam Model,ALC08-1042S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1042S,43.25,41.25,14.4375,8,0,52500,40,54 dBA,Steam at Specified Pressure,See Electrical Data ; 55 lbs / hr of Condensate,72,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 47in Nozzle Steam Model,ALC08-1048S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1048S,49.25,47.25,14.4375,8,0,60500,40,54 dBA,Steam at Specified Pressure,See Electrical Data ; 63 lbs / hr of Condensate,80,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 59in Nozzle Steam Model,ALC08-1060S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1060S,61,59,14.4375,8,0,75300,41,54 dBA,Steam at Specified Pressure,See Electrical Data ; 78 lbs / hr of Condensate,95,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 73in Nozzle Steam Model,ALC08-1072S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-1072S,74.25,72.25,14.4375,8,0,93200,41,54 dBA,Steam at Specified Pressure,See Electrical Data ; 97 lbs / hr of Condensate,107,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 84in Nozzle Steam Model,ALC08-2084S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-2084S,86.25,84.25,14.4375,8,0,109400,41,57 dBA,Steam at Specified Pressure,See Electrical Data ; 113 lbs / hr of Condensate,134,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 96in Nozzle Steam Model,ALC08-2096S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-2096S,98.25,96.25,14.4375,8,0,125200,41,57 dBA,Steam at Specified Pressure,See Electrical Data ; 129 lbs / hr of Condensate,150,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return 120in Nozzle Steam Model,ALC08-2120S,Berner Steam Heated Air Door - Architectural Low Profile 8 Model ALC08-2120S,121.75,119.75,14.4375,8,0,154800,42,57 dBA,Steam at Specified Pressure,See Electrical Data ; 160 lbs / hr of Condensate,178,UL Indoors and Outdoors ; Made in USA ; FDA ; USDA,Steam Supply,Steam Return