ARCAT Free Architectural CAD drawings, blocks and details for download in dwg and pdf formats for use with AutoCAD and other 2D and 3D design software. By downloading and using any ARCAT CAD detail content you agree to the following [license agreement].

Continental Building Products
CONTENT
application/pdf
3285-075 - Area Separation Firewall Design - Interior Wall
image/vnd.dwg download: application/pdf view:
application/pdf
3285-076 - Area Separation Firewall Design - Exterior Wall Intersection A
image/vnd.dwg download: application/pdf view:
application/pdf
3285-077 - Area Separation Firewall Design - Exterior Wall Intersection B
image/vnd.dwg download: application/pdf view:
application/pdf
3285-078 - Area Separation Firewall Design - Exterior Wall Offset
image/vnd.dwg download: application/pdf view:
application/pdf
3285-079 - Area Separation Firewall Design - Exterior Roof Offset
image/vnd.dwg download: application/pdf view:
application/pdf
3285-080 - Area Separation Firewall Design - Wing Wall Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-081 - Area Separation Firewall Design - Parapet Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-082 - Area Separation Firewall Design - Intersection Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-083 - Area Separation Firewall Design - Roof Junction Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-031 - Area Separation Walls - Load-Bearing (Wood Studs only) 2-hour Rating UL U388 STC 42 RAL TL08-181
image/vnd.dwg download: application/pdf view:
application/pdf
3285-032 - Area Separation Walls - Load-Bearing (Wood Studs only) 2-hour Rating UL U388 STC 62 (Inslation one side STC 55) [RAL TL08-176]
image/vnd.dwg download: application/pdf view:
application/pdf
3285-033 - Non-Combustible Floor - Ceiling Systems Load-Bearing 1-hour Rating UL G534 STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-034 - Non-Combustible Floor - Ceiling Systems Load-Bearing 2-hour Rating UL G504 STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-036 - Non-Combustible Floor - Ceiling Systems Load-Bearing 3-hour Rating UL G512 STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-037 - Non-Combustible Floor - Ceiling Systems Load-Bearing 3-hour Rating UL G529 STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-001 - Non-Combustible Wall Systems Steel Stud Partitions - Non Load-Bearing 1-hour Rating UL U465 - STC 38
image/vnd.dwg download: application/pdf view:
application/pdf
3285-002 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Rating UL U465 - STC 48
image/vnd.dwg download: application/pdf view:
application/pdf
3285-003 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Rating UL U465 - STC 48 RAL-TL99-160
image/vnd.dwg download: application/pdf view:
application/pdf
3285-004 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Rating UL U465 - STC 53
image/vnd.dwg download: application/pdf view:
application/pdf
3285-005 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Rating UL U448 - STC 42
image/vnd.dwg download: application/pdf view:
application/pdf
3285-006 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Rating UL U448 - STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-007 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 2-hour Rating UL U411 - STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-008 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 2-hour Rating UL U411 - STC 54
image/vnd.dwg download: application/pdf view:
application/pdf
3285-009 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 2-hour Rating UL U412 - STC 45
image/vnd.dwg download: application/pdf view:
application/pdf
3285-010 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 2-hour RatingUL U412 - STC 54
image/vnd.dwg download: application/pdf view:
application/pdf
3285-011 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 3-hour Rating UL U435 - STC 50
image/vnd.dwg download: application/pdf view:
application/pdf
3285-012 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 3-hour Rating UL U435 - STC 58
image/vnd.dwg download: application/pdf view:
application/pdf
3285-013 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 4-hour Rating UL U435 - STC 53
image/vnd.dwg download: application/pdf view:
application/pdf
3285-014 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 4-hour Rating UL U435 - STC 62
image/vnd.dwg download: application/pdf view:
application/pdf
3285-051 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 2-hour Fire Rating UL U421 - STC 45
image/vnd.dwg download: application/pdf view:
application/pdf
3285-052 - Non-Combustible Wall Systems Steel Stud Partitions – Non Load-Bearing 1-hour Fire Rating UL V450 - STC 38
image/vnd.dwg download: application/pdf view:
application/pdf
3285-054 - Shaftwall Design - Light Use Handrail Support Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-055 - Shaftwall Design - Column Bypass Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-056 - Shaftwall Design - Mediun Use Handrail Support Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-057 - Shaftwall Design - Corner Column Bypass Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-058 - Shaftwall Design - Heavy User Handrail Support Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-060 - Shaftwall Design - Steel Beam Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-061 - Shaftwall Design - Inside Corner Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-062 - Shaftwall Design - Wall Offset from Steel Beam Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-063 - Shaftwall Design - Outside Corner Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-064 - Shaftwall Design - Control Joint Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-065 - Shaftwall Design - Typical Joint Layout
image/vnd.dwg download: application/pdf view:
application/pdf
3285-066 - Shaftwall Design - Alternate Intersections
image/vnd.dwg download: application/pdf view:
application/pdf
3285-067 - Shaftwall Design - Rough Opening for Duct
image/vnd.dwg download: application/pdf view:
application/pdf
3285-068 - Shaftwall Design - Opening for Unprotected Duct, Shown with Typical Fire Damper
image/vnd.dwg download: application/pdf view:
application/pdf
3285-069 - Shaftwall Design - Section View of Horizontal Duct Protection
image/vnd.dwg download: application/pdf view:
application/pdf
3285-070 - Shaftwall Design - Rough Opening for Door Families
image/vnd.dwg download: application/pdf view:
application/pdf
3285-071 - Shaftwall Design - Outlet Call or Indicator Boxes Exceeding 16 Square Inches
image/vnd.dwg download: application/pdf view:
application/pdf
3285-072 - Shaftwall Design - Typical Door Head Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-073 - Shaftwall Design - Typical Door Jamb Detail
image/vnd.dwg download: application/pdf view:
application/pdf
3285-074 - Shaftwall Design - Typical Door Jamb Detail 2
image/vnd.dwg download: application/pdf view:
application/pdf
3285-044 - Steel C-Joist and Light Gage Steel Trusses Floor - Ceiling Systems 1-hour Rating UL L524 STC 39
image/vnd.dwg download: application/pdf view:
application/pdf
3285-045 - Steel C-Joist and Light Gage Steel Trusses Floor - Ceiling Systems 1-hour Rating UL L548 STC 41
image/vnd.dwg download: application/pdf view:
application/pdf
3285-046 - Steel Columns – Fire Rated Systems Load-Bearing 1-hour Rating UL X528
image/vnd.dwg download: application/pdf view:
application/pdf
3285-047 - Steel Columns – Fire Rated Systems Load-Bearing 2-hour Rating UL X521
image/vnd.dwg download: application/pdf view:
application/pdf
3285-048 - Steel Columns – Fire Rated Systems Load-Bearing 3-hour Rating UL X528
image/vnd.dwg download: application/pdf view:
application/pdf
3285-015 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 1-hour Rating UL U420 - STC 42
image/vnd.dwg download: application/pdf view:
application/pdf
3285-016 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 1-hour Rating UL U420 - STC 55
image/vnd.dwg download: application/pdf view:
application/pdf
3285-017 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 2-hour Rating UL U420 - STC 52
image/vnd.dwg download: application/pdf view:
application/pdf
3285-018 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 2-hour Rating UL U420 - STC 60
image/vnd.dwg download: application/pdf view:
application/pdf
3285-019 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 3-hour Rating UL U436 - STC 54
image/vnd.dwg download: application/pdf view:
application/pdf
3285-020 - Steel Stud Partitions – Non Load-Bearing Double Stud – Chase Walls 3-hour Rating UL U436 - STC 62
image/vnd.dwg download: application/pdf view:
application/pdf
3285-021 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 38
image/vnd.dwg download: application/pdf view:
application/pdf
3285-022 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 49
image/vnd.dwg download: application/pdf view:
application/pdf
3285-023 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 54
image/vnd.dwg download: application/pdf view:
application/pdf
3285-024 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 39
image/vnd.dwg download: application/pdf view:
application/pdf
3285-025 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 45
image/vnd.dwg download: application/pdf view:
application/pdf
3285-026 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 2-hour Rating STC 55
image/vnd.dwg download: application/pdf view:
application/pdf
3285-049 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 1-hour Fire Rating UL V481 STC 36
image/vnd.dwg download: application/pdf view:
application/pdf
3285-050 - Steel Stud Partitions – Non-Load-Bearing Shaftwall Assemblies 3-hour Fire UL V481 Rating - STC 44
image/vnd.dwg download: application/pdf view:
application/pdf
3285-038 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Rating UL L501 STC 38
image/vnd.dwg download: application/pdf view:
application/pdf
3285-039 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Rating UL L503 STC 38
image/vnd.dwg download: application/pdf view:
application/pdf
3285-040 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Rating UL L542 STC 42
image/vnd.dwg download: application/pdf view:
application/pdf
3285-041 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Rating UL L544 STC 48
image/vnd.dwg download: application/pdf view:
application/pdf
3285-042 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Rating UL L528 (UL L585 with Damper) STC 48
image/vnd.dwg download: application/pdf view:
application/pdf
3285-043 - Wood Framed Floor - Ceiling Systems Load-Bearing 2-hour Rating UL L505 STC 40
image/vnd.dwg download: application/pdf view:
application/pdf
3285-053 - Wood Framed Floor - Ceiling Systems Load-Bearing 1-hour Fire Rating UL P547
image/vnd.dwg download: application/pdf view:
application/pdf
3285-027 - Wood Stud Wall Systems Wall Partitions – Load-Bearing 1-hour Rating STC 32
image/vnd.dwg download: application/pdf view:
application/pdf
3285-028 - Wood Stud Wall Systems Wall Partitions – Load-Bearing 1-hour Rating STC 45
image/vnd.dwg download: application/pdf view:
application/pdf
3285-029 - Wood Stud Wall Systems Wall Partitions – Load-Bearing 2-hour Rating STC 36
image/vnd.dwg download: application/pdf view:
application/pdf
3285-030 - Wood Stud Wall Systems Double Stud Chase Wall – Load-Bearing 1-hour Rating UL U341 STC 57
image/vnd.dwg download: application/pdf view:
application/pdf
3285-032 - Area Separation Walls – Load-Bearing (Wood Studs only) 2-hour Rating UL U388 STC 62 (Inslation one side STC 55) [RAL TL08-176]
image/vnd.dwg download: application/pdf view: