Shelter-Rite Architectural Fabrics
CONTENT

Shelter-Rite 3820 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 5.0 oz/yd2Metric: 170 g/m2Finished Coated WeightASTM D751Standard: 20.0 oz/yd2 +2/-1 oz/yd2)Metric: 678 g/m2 (+70/-35 g/m2)Grab TensileASTM D751Standard: 375/325 lbMetric: 1669/1446 NStrip TensileASTM D751 Procedure BStandard: 10 lb/inMetric: 9 daN/5 cmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaLow Temperature - LTCASTM D2136 (1/8" mandrel, 4 hr)Standard: Pass @ -40 degrees FMetric: Pass @ -40 degrees CFlame ResistanceMeets NFPA 701; FED-STD-191 Method 5903 – 2 second flameout;ASTM 6413-13 - 2 second flameout;Registered by California Fire Marshal (No. F-10302);ASTM E84 & ULC-S102 - flame spread index ≤25, smoke development rating ≤450 Request a Shelter-Rite® Tent™ Sample 
Rated 5 based on 1 product reviews

Shelter-Rite® 8028 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 7.5 oz/yd2Metric: 250 g/m2Finished Coated WeightASTM D751Standard: 28.0 oz/yd2 (+2/-1 oz/yd2)Metric: 950 g/m2 (+70/-35 g/m2)NOTE: Average weight of opaque fabrics will be ~ 4 oz/yd2 (140 g/m2) heavierTrapezoid TearASTM D4533Standard: 85/85 lbMetric: 380/380 NGrab TensileASTM D751Standard: 700/700 lbMetric: 3115/3115 NStrip TensileASTM D751 Procedure BStandard: 515/515 lb/inMetric: 4500/4500 N/50 mmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 90 N/50 mmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaDead Load Seam StrengthASTM D7512 in (50 mm) seam, 4 hr, 1 in (25 mm) stripStandard: 266 lb @ 70 degrees F, 133 lb @ 160 degrees FMetric: 1180 N @ 21 degrees C, 590 N @ 71 degrees CLow Temperature - LTCASTM D2136 - LTA1/8" mandrel, 4 hrStandard: Pass @ -40 degrees F, Pass @ -67 degrees FMetric: Pass @ -40 degrees C, Pass @ -55 degrees CFlame ResistanceMeets NFPA 701; ULC-S109; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-10301); GB8624-2006;ASTM E84 & ULC-S102 - flame spread index ≤25, smoke development rating ≤45 Request a Shelter-Rite Architectural Fabrics Sample 
Rated 5 based on 1 product reviews

Shelter-Rite® 8324 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (normal)Standard: 4.3 oz/yd2Metric: 145 g/m2Finished Coated WeightASTM D751Standard: 24.0 oz/yd2 (+2/-1 oz/yd2)Metric: 815 g/m2 (+70/-35 g/m2)Trapezoid TearASTM D4533Standard: 80/65 lbMetric: 355/290 NGrab TensileASTM D751Standard: 400/350 lbMetric: 1780/1560 NStrip TensileASTM D751 Procedure BStandard: 300/240 lb/inMetric: 2630/2100 N/50 mmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 90 N/50 mmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaDead Load Seam StrengthASTM D751 (2 in (50 mm) seam, 4 hr, 1 in (25 mm) strip)Standard: 120 lb @ 70 degrees F, 60 lb @ 160 degrees FMetric: 530 N @ 21 degrees C, 270 N @ 71 degrees CLow Temperature - LTCASTM D2136 - LTA1/8" mandrel, 4 hrStandard: Pass @ -40 degrees F, Pass @ -67 degrees FMetric: Pass @ -40 degrees C, Pass @ -55 degrees CFlame ResistanceMeets NFPA 701; ULC-S109; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-97701);ASTM E84 & ULC-S102 - flame spread index ≤25, smoke development rating ≤450 Request a Shelter-Rite Architectural Fabrics Sample  
Rated 5 based on 1 product reviews

Shelter-Rite® 8421 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 5.0 oz/yd2Metric: 170 g/m2Finished Coated WeightASTM D751Standard: 21.0 oz/yd2 (+2/-1 oz/yd2)Metric: 712 g/m2 (+70/-35 g/m2)NOTE: Average weight of opaque fabrics will be ~ 4 oz/yd2 (140 g/m2) heavierTrapezoid TearASTM D4533Standard: 50/60 lbMetric: 23/267 NGrab TensileASTM D751Standard: 375/350 lbMetric: 1669/1558 NStrip TensileASTM D751 Procedure BStandard: 350/325 lb/inMetric: 307/285 daN/5 cmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 9 daN/5 cmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaDead Load Seam StrengthASTM D7512 in (50 mm) seam, 4 hr, 1 in (25 mm) stripStandard: 106 lb @ 70 degrees F, 53 lb @ 160 degrees FMetric: 472 N @ 21 degrees C, 233 N @ 71 degrees CLow Temperature - LTCASTM D21361/8" mandrel, 4 hrStandard: Pass @ -40 degrees FMetric: Pass @ -40 degrees CFlame ResistanceMeets NFPA 701; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-10302);ASTM E84 - flame spread index ≤25, smoke development rating ≤450
Rated 5 based on 1 product reviews

Shelter-Rite® 8424 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 5.0 oz/yd2Metric: 170 g/m2Finished Coated WeightASTM D751Standard: 24.0 oz/yd2 (+2/-1 oz/yd2)Metric: 815 g/m2 (+70/-35 g/m2)NOTE: Average weight of opaque fabrics will be ~ 4 oz/yd2 (140 g/m2) heavierTrapezoid TearASTM D4533Standard: 50/60 lbMetric: 220/270 NGrab TensileASTM D751Standard: 375/350 lbMetric: 1670/1560 NStrip TensileASTM D751 Procedure BStandard: 300/275 lb/inMetric: 2630/2400 N/50 mmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 90 N/50 mmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaDead Load Seam StrengthASTM D7512 in (50 mm) seam, 4 hr, 1 in (25 mm) stripStandard: 106 lb @ 70 degrees F, 53 lb @ 160 degrees FMetric: 470 N @ 21 degrees C, 235 N @ 71 degrees CLow Temperature - LTCASTM D2136 - LTA1/8" mandrel, 4 hrStandard: Pass @ -40 degrees F, Pass @ -67 degrees FMetric: Pass @ -40 degrees C, Pass @ -55 degrees CFlame ResistanceMeets NFPA 701; ULC-S109; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-10301);ASTM E84 & ULC-S102 - flame spread index ≤25, smoke development rating ≤450 Request a Shelter-Rite Architectural Fabrics Sample
Rated 5 based on 1 product reviews

Shelter-Rite® 8520 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 5.0 oz/yd2Metric: 170 g/m2Finished Coated WeightASTM D751Standard: 20.0 oz/yd2 (+2/-1 oz/yd2)Metric: 680 g/m2 (+70/-35 g/m2)Trapezoid TearASTM D4533Standard: 50/50 lbMetric: 220/220 NGrab TensileASTM D751Standard: 400/400 lbMetric: 1780/1780 NStrip TensileASTM D751 Procedure BStandard: 325/325 lb/inMetric: 2850/2850 N/50 mmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 90 N/50 mmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaLow Temperature - LTCASTM D21361/8" mandrel, 4 hrStandard: Pass @ -40 degrees F, Pass @ -67 degrees FMetric: Pass @ -40 degrees C, Pass @ -55 degrees CFlame ResistanceMeets NFPA 701; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-97901);ASTM E84 & ULC-S102 - flame spread index ≤25, smoke development rating ≤450 Request a Shelter-Rite Architectural Fabrics Sample
Rated 5 based on 1 product reviews

Shelter-Rite® 9032 Architectural Fabric - Shelter-Rite®

Base Fabric TypeStandard: PolyesterMetric: PolyesterBase Fabric Weight (nominal)Standard: 10.0 oz/yd2Metric: 340 g/m2Finished Coated WeightASTM D751Standard: 32.0 oz/yd2 (+2/-1 oz/yd2)Metric: 1085 g/m2 (+70/-35 g/m2)NOTE: Average weight of opaque fabrics will be ~ 4 oz/yd2 (140 g/m2) heavierTrapezoid TearASTM D4533Standard: 100/100 lbMetric: 445/445 NGrab TensileASTM D751Standard: 840/840 lbMetric: 3740/3740 NStrip TensileASTM D751 Procedure BStandard: 650/650 lb/inMetric: 5700/5700 N/50 mmAdhesionASTM D751 Dielectric WeldStandard: 10 lb/inMetric: 90 N/50 mmHydrostatic ResistanceASTM D751 Procedure AStandard: 500 psiMetric: 3.45 MPaDead Load Seam StrengthASTM D7512 in (50 mm) seam, 4 hr, 1 in (25 mm) stripStandard: 266 lb @ 70 degrees F, 133 lb @ 160 degrees FMetric: 1180 N @ 21 degrees C, 590 N @ 71 degrees CLow Temperature - LTCASTM D21361/8" mandrel, 4 hrStandard: Pass @ -40 degrees FMetric: Pass @ -40 degrees CFlame ResistanceMeets NFPA 701; ULC-S109; ASTM 6413 - 2 second flameout;Registered by California Fire Marshal (No. F-95301) Request a Shelter-Rite Architectural Fabrics Sample
Rated 5 based on 1 product reviews

Architectural Fabrics for the Following Structures

Choose to Make Your Architectural Fabric Structures ExtraordinaryNo matter the scope or size of your project, you can rely on our expertise and superior products to help you create a structure that deserves to be marveled at. We can meet the architectural fabric needs demanded by a variety of applications and structures. 
Rated 5 based on 1 product reviews

Air-Supported Structures

Fabric dome structures are popular for a wide range of athletic applications, from football to tennis. If your next project is an air dome structure that needs to be cost-effective, long-lasting and climate-controlled, Shelter-Rite® may be your solution. 
Rated 5 based on 1 product reviews

Frame Structures

Aluminum and steel frame structures cost less to build, are constructed more quickly than other structures and offer benefits of flexibility and sustainability.Shelter-Rite® has the solutions you need to make your frame structure reach landmark status. 
Rated 5 based on 1 product reviews

Tensile Structures

Our product offerings and flexibility allow for maximum creativity and innovation for tensile structure manufacturers. From canopies to music amphitheaters to sports complexes, Shelter-Rite® has the solutions for any open or closed tensile membrane structure design. 
Rated 5 based on 1 product reviews

Tent Structures

If you're looking for a lighter-weight, clearspan fabric for your rental tent or permanent frame structure applications that's just as strong as heavier fabrics, Shelter-Rite® Tent™ is your solution. Because Shelter-Rite Tent is 20% lighter than the industry standard, it's easier to handle, which leads to:Faster installationDecreased worker fatigueLess wear and tear during handling 
Rated 5 based on 1 product reviews

Technical Library

Fabric Performance Properties Material Safety Data Sheets Product Data Sheets Selection Guides
Rated 5 based on 1 product reviews

Air-Supported Structures Benefit University and Community

Two new air-supported structures on the Drexel University campus provides safe indoor space for the university and community to enjoy sports activities during cold weather months.
Rated 5 based on 1 product reviews

Fabric Structure Offers Unique Design and Functionality

When a company in the Northwest U.S. decided to build a new headquarters, it became clear to them that a fabric structure would take less construction time than traditional brick and mortar. Eleven months after construction started, the large fabric structure was move-in ready and turning heads for its unique design. 
Rated 5 based on 1 product reviews

Shelter-Rite® Shines Bright at Performing Arts Hall

Entrance canopy featuring Shelter-Rite architectural fabrics retrofitted by Signature Structures protects visitors from the weather conditions, aesthetically matches the roof of the Van Wezel Performing Arts Hall in Sarasota, Florida. 
Rated 5 based on 1 product reviews

Massive Clear Span Structure Makes a Huge Impression in Boston

The tension membrane structure is the first of several planned at Logan International Airport. 
Rated 5 based on 1 product reviews

Beijing Tennis Center Relies on Shelter-Rite to Protect Courts

The Sun Park Tennis Center was constructed within Beijing Sun Park using a pressurized air structure made from a Shelter-Rite architectural fabric with Tedlar® polyvinyl fluoride film (PVF). 
Rated 5 based on 1 product reviews

Custom Designed Structure Uses Architectural Fabric to Light the Way

The outdoor venue provides concert-goers pleasant, natural surroundings to enjoy the sounds and visual excitement of various national recording artists. 
Rated 5 based on 1 product reviews

Shelter-Rite Creates Distinctive Look for The Prisoner Wine Company

Entrance canopy sets the stage for what visitors are going to see when they enter the building.
Rated 5 based on 1 product reviews

Fieldhouse Dome Upgrades a Huge Hit in Plymouth, MN

Multi-sport dome in Minnesota provides indoor play space for soccer, softball, baseball, football, lacrosse, rugby and other community sports from November through late-March. 
Rated 5 based on 1 product reviews

Shelter-Rite Provides Protection From Frigid Minnesota Temps

Shelter-Rite® provides protection from frigid Minnesota temps. 
Rated 5 based on 1 product reviews