MasterFormat: 2014
Download this Continuous Insulation Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Rmax - A Business Unit of the Sika Corporation Continuous Insulation
 
         
SECTION 06 16 13
 
         
CONTINUOUS INSULATION
 
         
 
         
Copyright 2018 - 2018 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Rmax - A Business Unit of the Sika Corporation; Roof and Wall Insulation.
This section is based on the products of Rmax - A Business Unit of the Sika Corporation, which is located at:
13524 Welch Rd.
Dallas, TX 75244-5227
Toll Free Tel: 800-527-0890
Fax: 972-387-4673
Email: request info
Web: https://www.rmax.com/

[ Click Here ] for additional information.

The Leader in Building Insulation Solutions Since 1978.
For more than 30 years, Rmax has been creating insulation solutions based on the latest building science. Our full line of high-quality, polyiso-based roof, wall and specialty insulation products for commercial, industrial and residential applications deliver maximum R-values and minimum environmental impact, with efficiency in installation, cost and design. As new developments in building science emerge, rest assured that Rmax will remain on the forefront, manufacturing tested, engineered solutions that serve architects, builders, owners and occupants alike. Our people understand the diverse markets our products are used in. Their integrity and responsiveness work to your advantage. Our manufacturing plants in Dallas, TX, Greer, SC and Fernley, NV, with sales offices coast-to-coast, stand ready to serve you.
As one of the founding organizations behind the Polyisocyanurate Insulation Manufacturers Association (PIMA), Rmax has led the way in introducing environmentally acceptable polyiso products and solutions for all manner of building applications.
 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Continuous Insulation for Walls:
          1.ECOMAXci Wall Solution.
          2.Thermasheath-SI Wall Solution.
          3.ECOMAXci.
          4.ECOMAXci.
          5.ECOBASEci.
          6.Thermabase-CI.
          7.TSX-8500.
          8.TSX-8510.
          9.Thermasheath-SI.
          10.Thermasheath-3.
          11.Thermasheath-XP.
          12.Durasheath-3.
 
          B.Flashings and tapes.
 
          C.Insulation clips.
 
          D.Nailboard fasteners.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 03 30 00 - Cast-in-Place Concrete.
 
          B.Section 03 41 16 - Precast Concrete Slabs.
 
          C.Section 05 40 00 - Cold-Formed Metal Framing.
 
          D.Section 06 10 00 - Rough Carpentry.
 
          E.Section 07 26 23 - Below-Grade Gas Retarders .
 
          F.Section 07 27 26 - Fluid-Applied Membrane Air Barriers .
 
          G.Section 07 50 00 - Membrane Roofing.
 
          H.Section 09 22 16 - Non-Structural Metal Framing.
 
          I.Section 09 25 23 - Lime Based Plastering.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.AAMA 2605 - ANSI/SBCA FS 100-2012 Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies.
 
          B.AATCC Test Method 127 - Water Resistance: Hydryostatic Pressure Test
 
          C.ASTM International (ASTM):
          1.ASTM C209 - Standard Test Methods for Cellulosic Fiber Insulating Board.
          2.ASTM D1621 - Standard Test Method for Compressive Properties of Rigid Cellular Plastics.
          3.ASTM D1622 - Standard Test Method for Apparent Density of Rigid Cellular Plastics.
          4.ASTM D2126 - Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging.
          5.ASTM E2178 - Standard Test Method for Air Permeance of Building Materials.
          6.ASTM E 72 - Standard Test Methods of Conducting Strength Tests of Panels for Building Construction.
          7.ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
          8.ASTM E 96 - Standard Test Methods for Water Vapor Transmission of Materials.
          9.ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.
          10.ASTM E 564 - Standard Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings.
          11.ASTM E 2126 - Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings.
          12.ASTM E 2178 - Standard Test Method for Air Permeance of Building Materials.
          13.ASTM E 2357 - Standard Test Method for Determining Air Leakage of Air Barrier Assemblies.
 
          D.NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components.
 
          E.NFPA 286: Standard Methods Of Fire Tests For Evaluating Contribution Of Wall And Ceiling Interior Finish To Room Fire Growth
 
          F.SBCRI Single Element Lateral Load Testing.
 
          G.UL 1715 - Fire Test of Interior Finish Material.
 
          1.4SUBMITTALS
 
          A.Submit under provisions of Section 01 30 00 - Administrative Requirements.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Installation methods.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          C.Shop Drawings: Show fabrication and installation layouts of metal wall panels; details of edge conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings, closures, and accessories; and special details.
          1.Accessories: Include details of all integral panel components and their interface with adjacent materials.
          2.For installed products indicated to comply with design loads, include structural analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
 
          D.Verification Samples: For each finish product specified, two samples, minimum size 4 inches by 6 inches (102mm x 150 mm).
 
          1.5QUALITY ASSURANCE
 
          A.Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten years experience.
 
          B.Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of five years demonstrated experience in installing products of the same type and scope as specified.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          C.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Do not proceed with remaining work until workmanship is approved by Architect.
          3.Remodel mock-up area as required to produce acceptable work.
 
          D.Pre-installation Meeting: Conduct pre-installation meeting to verify project requirements, foundation/structural system/substrate conditions, and insulation manufacturer's installation instructions.
 
          1.6DELIVERY, STORAGE, AND HANDLING
 
          A.Store and handle products per manufacturer's instructions until ready for installation.
 
          1.7SEQUENCING
 
          A.Ensure that locating templates and other information required for installation of products of this section are furnished to affected trades in time to prevent interruption of construction progress.
 
          B.Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.
 
          1.9WARRANTY
 
          A.Insulation Warranty: At project closeout, provide to Owner an executed copy of the manufacturer's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Rmax - A Business Unit of the Sika Corporation, which is located at: 13524 Welch Rd.; Dallas, TX 75244-5227; Toll Free Tel: 800-527-0890; Fax: 972-387-4673; Email: request info; Web: https://www.rmax.com/
          1.Rmax - A Business Unit of the Sika Corporation; 13524 Welch Rd., Dallas, TX 75244. Toll Free Tel: 800-527-0890. Tel: 972-387-4500. Fax: 972-387-4673. Email: specs@rmax.com. Web:www.rmax.com .
          2.Rmax - A Business Unit of the Sika Corporation; 210 Lyon Dr., Fernley, NV 89408. Toll Free Tel: 800-762-9462. Tel: 775-575-4849. Fax: 775-575-5035. Email: specs@rmax.com. Web:www.rmax.com .
          3.Rmax - A Business Unit of the Sika Corporation; 1649 S. Batesville Rd., Greer, SC 29650. Toll Free Tel: 800-845-4455. Tel: 864-297-1382. Fax: 864-234-7548. Email: specs@rmax.com. Web:www.rmax.com .
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
 
          2.2CONTINUOUS INSULATION FOR WALLS
 
          A.ECOMAXci Wall Solution: Exterior continuous insulation solution for commercial walls including board insulation, tape, and flashing to provide continuous thermal and moisture protection of the vertical building exterior.
          1.Fire Performance in accordance with NFPA 285.
          2.Air Barrier System Performance in accordance with ASTM E2357 and CAN/ULC S742 (A1), less than 0.05
          3.Water-Resistive Barrier (WRB) per AC71 (ASTM E331, AATCC Test Method 127
          4.Compliance:
          a.ASTM C1289 Type I, Class 1
          b.ASHRAE 90.1
          c.International Energy Conservation Code (IECC)
          d.International Building Code (IBC) Section 2603, Foam Plastic
          e.DrJ TER 1212-03
          f.California Code of Regulations, Title 24
          g.Tested per NFPA 285 to comply with Section 2603.5.5 of the IBC
          h.Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes
          i.1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory Design No.: U026, U326, U330, U354, U424, U460,U902, U904, U905, U906, U907, V454, V499
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          5.Continuous Insulation: ECOMAXci - Thickness/R Value: 1.0 inches (25mm)/R-6.5.
          6.Continuous Insulation: ECOMAXci - Thickness/R Value: 1.5 inches (38mm)/R-10.
          7.Continuous Insulation: ECOMAXci - Thickness/R Value: 2.0 inches (51mm)/R-13.1.
          8.Continuous Insulation: ECOMAXci - Thickness/R Value: 2.5 inches (64mm)/R-16.7.
          9.Continuous Insulation: ECOMAXci - Thickness/R Value: 3.0 inches (76mm)/R-20.3.
          10.Continuous Insulation: ECOMAXci - Thickness/R Value: 3.5 inches (89mm)/R-23.9.
          11.Continuous Insulation: ECOMAXci - Thickness/R Value: 4.0 inches (102mm)/R-27.4.
          12.Continuous Insulation: ECOMAXci - Thickness/R Value: 4.5 inches (114mm)/R-31.
          ** NOTE TO SPECIFIER ** Flashing Tape(s) required for solution.
          13.Flashing Tape: R-SEAL 3000.
          14.Flashing Tape: R-SEAL 6000.
 
          B.Thermasheath-SI Wall Solution: Exterior continuous insulation solution for residential walls including structural insulation board, tape, and flashing to provide continuous thermal and moisture protection of the vertical building exterior.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1 Polyiso.
          b.International Residential Code (IRC).
          c.International Building Code (IBC), Type V Construction.
          d.International Energy Conservation Code (IECC).
          e.ASHRAE 90.1
          f.DrJ TER 1207-01.
          g.California Code of Regulations, Title 24.
          h.Tested per NFPA 286 to comply with ICC-ES AC12 Appendix B.
          i.Water Resistive Barrier (WRB) per AC71 (ASTM E331, AATCC Test Method 127)
          j.Air Barrier Material per ASTM E2178.
          k.1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory. Design No.: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454, V499.
          2.Structural Performance in accordance with ASTM E72.
          3.Structural Performance in accordance with ASTM E564.
          4.Structural Performance in accordance with ASTM E2126.
          5.Structural Performance in accordance with SBCRI Single Element Lateral Load testing.
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          6.Insulation: Thermasheath-SI - Thickness/R Value: 0.5 inches (13mm)/R-3.2.
          7.Insulation: Thermasheath-SI - Thickness/R Value: 0.75 inches (19mm)/R-5.0.
          8.Insulation: Thermasheath-SI - Thickness/R Value: 1.0 inches (25mm)/R-6.0.
          ** NOTE TO SPECIFIER ** Select Flashing Tape. Retain only those required on the project.
          9.Flashing Tape: R-SEAL Construction Tape.
          10.Flashing Tape: R-SEAL 3000.
          11.Flashing Tape: R-SEAL 6000.
          ** NOTE TO SPECIFIER ** Retain only insulation types required on the project and delete all others.
 
          C.ECOMAXci: Closed-cell polyisocyanurate insulation with a 12mil glass fiber reinforced foil facer on one side and a 10mil glass fiber reinforced foil facer on the other side.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1
          b.ASHRAE 90.1
          c.International Energy Conservation Code (IECC)
          d.International Building Code (IBC) Section 2603, Foam Plastic
          e.DrJ TER 1212-03
          f.California Code of Regulations, Title 24
          g.Tested per NFPA 285 to comply with Section 2603.5.5 of the IBC
          h.Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes
          i.1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory Design No.: U026, U326, U330, U354, U424, U460,U902, U904, U905, U906, U907, V454, V499
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 25 psi.
          4.Flame Spread in accordance with ASTM E84: 25 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.03 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Air Permeance in accordance with ASTM E2178: Less than 0.02 L/(s.m2)
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          10.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.5.
          11.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 10.0.
          12.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 13.1.
          13.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 16.7.
          14.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 20.3.
          15.Thickness: 3.5 inches (89mm)
          a.Thermal Resistance (R): 23.9.
          16.Thickness: 4.0 inches (102mm)
          a.Thermal Resistance (R): 27.4.
          17.Thickness: 4.5 inches (114mm)
          a.Thermal Resistance (R): 31.0.
 
          D.ECOBASEci: Closed-cell polyisocyanurate (polyiso) foam insulation with inorganic, polymer coated glass fiber mat facers bonded to fire retardant treated plywood (FRTP)
          1.Compliance:
          a.ASTM C1289 Type V.
          b.ASHRAE 90.1.
          c.DrJ TER 1504-04
          d.International Energy Conservation Code (IECC).
          e.IBC Section 2603.
          f.NFPA 285 Section 2603.5.5 of the IBC.
          g.California Code of Regulations, Title 24
          h.1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory Design No.: U026, U326, U330, U354, U424, U460,U902, U904, U905, U906, U907, V454, V499
          ** NOTE TO SPECIFIER ** Performance data for polyiso insulation only.
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread, Core in accordance with ASTM E84: 75 or less.
          5.Smoke Developed, Core in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 1.5 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 1 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Delete plywood thickness not required.
          10.Plywood Thickness: 5/8 inch (16 mm).
          11.Plywood Thickness: 3/4 inch (10 mm).
          ** NOTE TO SPECIFIER ** 5/8 inch plywood construction: Insulation thickness only. Retain only thicknesses actually required on the project and delete all others.
          12.Insulation Thickness: 0.75 inches (19mm).
          a.Overall Thickness: 1-3/8 inches (35 mm).
          b.Thermal Resistance (R): 5.2.
          13.Insulation Thickness: 1.0 inches (25mm).
          a.Overall Thickness: 1-5/8 inches (41 mm).
          b.Thermal Resistance (R): 6.7.
          14.Insulation Thickness: 1.5 inches (38mm).
          a.Overall Thickness: 2-1/8 inches (54 mm).
          b.Thermal Resistance (R): 9.7.
          15.Insulation Thickness: 2.0 inches (51mm).
          a.Overall Thickness: 2-5/8 inches (67 mm).
          b.Thermal Resistance (R): 12.8.
          16.Insulation Thickness: 2.5 inches (64mm).
          a.Overall Thickness: 3-1/8 inches (79 mm).
          b.Thermal Resistance (R): 16.0.
          17.Insulation Thickness: 3.0 inches (76mm).
          a.Overall Thickness: 3-5/8 inches (92 mm).
          b.Thermal Resistance (R): 19.2.
          18.Insulation Thickness: 3.5 inches (89mm).
          a.Overall Thickness: 4-1/8 inches (105 mm).
          b.Thermal Resistance (R): 22.4.
          19.Insulation Thickness: 4.0 inches (102mm).
          a.Overall Thickness: 4-5/8 inches (117 mm).
          b.Thermal Resistance (R): 25.7.
          20.Insulation Thickness: 4.5 inches (114mm).
          a.Overall Thickness: 5-1/8 inches (130 mm).
          b.Thermal Resistance (R): 29.0.
          ** NOTE TO SPECIFIER ** 3/4 inch plywood construction: Insulation thickness only. Retain only thicknesses actually required on the project and delete all others.
          21.Insulation Thickness: 0.75 inches (19mm).
          a.Overall Thickness: 1-1/2 inches (38 mm).
          b.Thermal Resistance (R): 5.4.
          22.Insulation Thickness: 1.0 inches (25mm).
          a.Overall Thickness: 1-3/4 inches (44 mm).
          b.Thermal Resistance (R): 6.9.
          23.Insulation Thickness: 1.5 inches (38mm).
          a.Overall Thickness: 2-1/4 inches (57 mm).
          b.Thermal Resistance (R): 9.9.
          24.Insulation Thickness: 2.0 inches (51mm).
          a.Overall Thickness: 2-3/4 inches (70 mm).
          b.Thermal Resistance (R): 13.0.
          25.Insulation Thickness: 2.5 inches (64mm).
          a.Overall Thickness: 3-1/4 inches (83 mm).
          b.Thermal Resistance (R): 16.2.
          26.Insulation Thickness: 3.0 inches (76mm).
          a.Overall Thickness: 3-3/4 inches (95 mm).
          b.Thermal Resistance (R): 19.4.
          27.Insulation Thickness: 3.5 inches (89mm).
          a.Overall Thickness: 4-1/4 inches (108 mm).
          b.Thermal Resistance (R): 22.6.
          28.Insulation Thickness: 4.0 inches (102mm).
          a.Overall Thickness: 4-3/4 inches (121 mm).
          b.Thermal Resistance (R): 25.9.
          29.Insulation Thickness: 4.5 inches (114mm).
          a.Overall Thickness: 5-1/4 inches (133 mm).
          b.Thermal Resistance (R): 29.2.
 
          E.Thermabase-CI: Closed-cell polyisocyanurate (polyiso) foam insulation layer bonded to a nailing surface.
          ** NOTE TO SPECIFIER ** Delete insulation layer not required.
          1.Insulation Layer: Rmax Thermasheath-3.
          2.Insulation Layer: Rmax Durasheath-3.
          ** NOTE TO SPECIFIER ** nailing surface other than standard is a special order. Delete nailing surface(s) not required.
          3.Nailing Surface (standard): 7/16 inch (11mm) OSB (APA rated).
          4.Compliance:
          a.ASTM C1289 Type V.
          b.ASHRAE 90.1.
          c.International Energy Conservation Code (IECC).
          d.IRC (International Residential Code).
          e.California Code of Regulations, Title 24
          ** NOTE TO SPECIFIER ** Performance data for polyiso insulation only.
          5.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          6.Compressive Strength in accordance with ASTM D1621: 20 psi.
          7.Flame Spread, Core in accordance with ASTM E84: 75 or less.
          8.Smoke Developed, Core in accordance with ASTM E84: 450 or less.
          ** NOTE TO SPECIFIER ** Performance data for Thermasheath-3 insulation only. Delete if not required.
          9.Water Vapor Transmission in accordance with ASTM E96: Less than 0.3 perms.
          10.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          ** NOTE TO SPECIFIER ** Performance data for Durasheath-3 only. Delete if not required.
          11.Water Vapor Transmission in accordance with ASTM E96: Less than 1.5 perms.
          12.Water Absorption in accordance with ASTM C209: Less than 1 percent by volume.
          13.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          14.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** 7/16 inch OSB (standard) construction with Thermasheath-3 insulation: Composite insulation and wood thickness. Retain only thicknesses actually required on the project and delete all others.
          15.Composite Insulation and Wood Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 3.8.
          16.Composite Insulation and Wood Thickness: 1.25 inches (32mm).
          a.Thermal Resistance (R): 5.3.
          17.Composite Insulation and Wood Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 6.6.
          18.Composite Insulation and Wood Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 10.2.
          19.Composite Insulation and Wood Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 13.7.
          20.Composite Insulation and Wood Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 17.3.
          21.Composite Insulation and Wood Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 20.9.
          22.Composite Insulation and Wood Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 24.5.
          23.Composite Insulation and Wood Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 28.0.
          24.Composite Insulation and Wood Thickness: 5.0 inches (127mm).
          a.Thermal Resistance (R): 31.6.
          ** NOTE TO SPECIFIER ** 7/16 inch OSB (standard) construction with Durasheath-3 insulation: Composite Insulation and wood thickness. Retain only thicknesses actually required on the project and delete all others.
          25.Composite Insulation and Wood Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 3.6.
          26.Composite Insulation and Wood Thickness: 1.25 inches (32mm).
          a.Thermal Resistance (R): 5.1.
          27.Composite Insulation and Wood Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 6.6.
          28.Composite Insulation and Wood Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 9.6.
          29.Composite Insulation and Wood Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 12.7.
          30.Composite Insulation and Wood Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 15.9.
          31.Composite Insulation and Wood Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 19.1.
          32.Composite Insulation and Wood Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 22.3.
          33.Composite Insulation and Wood Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 25.6.
          34.Composite Insulation and Wood Thickness: 5.0 inches (127mm).
          a.Thermal Resistance (R): 28.9.
 
          F.TSX-8500: Exposed use, closed-cell polyisocyanurate insulation with a 12 mil glass fiber reinforced foil facer on one side and a 10mil glass fiber reinforced foil facer on the other side.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1.
          b.ASHRAE 90.1.
          c.International Energy Conservation Code (IECC).
          d.International Building Code (IBC) Section 2603, Foam Plastic.
          e.DRJ TER 1309-03.
          f.ESR-1864, ICC Evaluation Service.
          g.Miami-Dade County Product Control Approved.
          h.RR 25322, City of Los Angeles Research Report.
          i.California Code of Regulations, Title 24.
          j.Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes.
          k.Tested per UL1715 to comply with IBC Section 2603, Special Approval paragraph:
          1)Up to 4.5 inches (114 mm) on walls.
          2)Up to 12 inches (305 mm) on ceilings.
          l.Tested per NFPA 285 to comply with IBC Section 2603.5.5
          m.Water-Resistive Barrier (WRB) per AC71 (ASTM E331, AATCC Test Method 127)
          n.Air Barrier Material per ASTM E2178
          o.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454 and V499.
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 25 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.3 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 1 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Air Permeance in accordance with ASTM E2178: Less than 0.02 L/(s.m2)
          10.Fire Performance in accordance with UL 1715.
          11.Fire Performance in accordance with NFPA 285.
          12.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          13.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
          14.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 9.6.
          15.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 13.1.
          16.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 16.7.
          17.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 20.3.
          18.Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 23.9.
          19.Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 27.4.
          20.Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 31.0.
 
          G.TSX-8510: Exposed use, closed-cell polyisocyanurate insulation with a 12mil glass fiber reinforced white coated foil facer on one side and a 10mil glass fiber reinforced foil facer on the other side.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1.
          b.ASHRAE 90.1.
          c.International Energy Conservation Code (IECC).
          d.International Building Code (IBC) Section 2603, Foam Plastic
          e.DRJ TER 1309-03
          f.ESR-1864, ICC Evaluation Service
          g.Miami-Dade County Product Control Approved
          h.RR 25322, City of Los Angeles Research Report
          i.California Code of Regulations, Title 24
          j.Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes
          k.Tested per UL1715 to comply with IBC Section 2603, Special Approval paragraph:
          1)Up to 4.5 inches on walls
          2)Up to 12 inches on ceilings
          l.Tested per NFPA 285 to comply with IBC Section 2603.5.5
          m.Water-Resistive Barrier (WRB) per AC71 (ASTM E331, AATCC Test Method 127)
          n.Air Barrier Material per ASTM E2178
          o.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454, V499
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 25 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.03 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Air Permeance in accordance with ASTM E2178: Less than 0.02 L/(s.m2)
          10.Fire Performance in accordance with UL 1715.
          11.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          12.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
          13.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 9.6.
          14.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 13.1.
          15.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 16.7.
          16.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 20.3.
          17.Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 23.9.
          18.Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 27.4.
          19.Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 31.0.
 
          H.Thermasheath-SI: Composite product made up of an insulation and structural component. The insulation component is a closed-cell polyisocyanurate insulation with reinforced foil facer on each side. Performance data for polyiso insulation only.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1 Polyiso.
          b.International Residential Code (IRC).
          c.International Building Code (IBC) Type V Construction.
          d.International Energy Conservation Code (IECC).
          e.ASHRAE 90.1.
          f.DrJ TER 1207-01.
          g.Structural:
          1)ASTM E72, ASTM E564, ASTM 2126 and SBCRI Single Element Lateral Load testing.
          h.Tested per NFPA 286 to comply with ICC-ES AC12 Appendix B
          i.Water-Resistive Barrier (WRB) per AC71 (ASTM E331, AATCC Test Method 127)
          j.Air Barrier Material per ASTM E2178
          k.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory:
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454, V499
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 75 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.03 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Air Permeance in accordance with ASTM E2178: Less than 0.02 L/(s.m2)
          10.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          11.Thickness: 0.5 inches (13mm).
          a.Thermal Resistance (R): 3.2.
          12.Thickness: 0.75 inches (19mm).
          a.Thermal Resistance (R): 5.0.
          13.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
 
          I.Thermasheath-3: Closed-cell polyisocyanurate insulation with reinforced foil facer on each side.
          1.Compliance:
          a.ASTM C1289 Type I, Class 1
          b.ASHRAE 90.1.
          c.International Energy Conservation Code (IECC).
          d.International Building Code (IBC) Section 2603, Foam Plastic.
          e.DrJ TER 1309-03.
          f.ESR-1864, ICC Evaluation Service.
          g.Miami-Dade County Product Control Approved.
          h.RR 25322, City of Los Angeles Research Report.
          i.California Code of Regulations, Title 24.
          j.Canadian Construction Materials Centre Evaluation #CCMC 13381-L manufactured to conform to CAN/ULC-S704-03 Type 1, Class 1.
          k.Air Barrier Material per ASTM E2178.
          l.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory:
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454, V499
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 75 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.03 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Air Permeance in accordance with ASTM E2178: Less than 0.02 L/(s.m2)
          10.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          11.Thickness: 0.5 inches (13mm).
          a.Thermal Resistance (R): 3.2.
          12.Thickness: 0.75 inches (19mm).
          a.Thermal Resistance (R): 5.0.
          13.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
          14.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 9.6.
          15.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 13.1.
          16.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 16.7.
          17.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 20.3.
          18.Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 23.9.
          19.Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 27.4.
          20.Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 31.0.
 
          J.Thermasheath-XP: Closed-cell polyisocyanurate (polyiso) foam, which is bonded on both sides with highly durable, embossed aluminum facers. One side has a white modified acrylic coating and the other side has a reflective surface with a clear coating. .
          1.Compliance:
          a.ASTM C1289 Type I, Class 1
          b.International Residential Code (IRC).
          c.International Building Code (IBC) Section 2603, Foam Plastic.
          d.International Energy Conservation Code (IECC).
          e.ASHRAE 90.1.
          f.DrJ TER 1309-03.
          g.California Code of Regulations, Title 24
          h.Air Barrier Material per ASTM E2178.
          i.Class A Flame Spread and Smoke Developed Indices per IBC Chapter 8, Interior Finishes.
          j.Tested per UL1715 to comply with IBC Section 2603, Special Approval paragraph:
          1)Up to 12 inches on ceilings.
          2)Up to 4.5 inches on walls.
          k.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory:
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454 and V499.
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 25 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 0.03 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 0.2 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          10.Thickness: 0.75 inches (19mm).
          a.Thermal Resistance (R): 5.0.
          11.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
          12.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 9.6.
          13.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 13.1.
          14.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 16.7.
          15.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 20.3.
          16.Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 23.9.
          17.Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 27.4.
          18.Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 31.0.
 
          K.Durasheath-3: Closed-cell polyisocyanurate insulation with an inorganic polymer coated glass fiber mat facer on each side.
          1.Compliance:
          a.ASTM C1289 Type II, Class 2
          b.ASHRAE 90.1.
          c.International Building Code (IBC) Section 2603, Foam Plastic
          d.California Code of Regulations, Title 24
          e.1,2,3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory:
          1)Design No: U026, U326, U330, U354, U424, U460, U902, U904, U905, U906, U907, V454, and V499.
          2.Density (Nominal) in accordance with ASTM D1622: 2.0 pcf.
          3.Compressive Strength in accordance with ASTM D1621: 20 psi.
          4.Flame Spread in accordance with ASTM E84: 75 or less.
          5.Smoke Developed in accordance with ASTM E84: 450 or less.
          6.Water Vapor Transmission in accordance with ASTM E96: Less than 1.5 perms.
          7.Water Absorption in accordance with ASTM C209: Less than 1 percent by volume.
          8.Dimensional Stability in accordance with ASTM D2126: Less than 2 percent linear change.
          9.Service temperature: -40 degree F to +250 degree F (-38 degree C to 121 degree C).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          10.Thickness: 0.5 inches (13mm).
          a.Thermal Resistance (R): 3.0.
          11.Thickness: 0.75 inches (19mm).
          a.Thermal Resistance (R): 4.5.
          12.Thickness: 1.0 inches (25mm).
          a.Thermal Resistance (R): 6.0.
          13.Thickness: 1.5 inches (38mm).
          a.Thermal Resistance (R): 9.0.
          14.Thickness: 2.0 inches (51mm).
          a.Thermal Resistance (R): 12.1.
          15.Thickness: 2.5 inches (64mm).
          a.Thermal Resistance (R): 15.3.
          16.Thickness: 3.0 inches (76mm).
          a.Thermal Resistance (R): 18.5.
          17.Thickness: 3.5 inches (89mm).
          a.Thermal Resistance (R): 21.7.
          18.Thickness: 4.0 inches (102mm).
          a.Thermal Resistance (R): 25.0.
          19.Thickness: 4.5 inches (114mm).
          a.Thermal Resistance (R): 28.3.
          ** NOTE TO SPECIFIER ** Retain only flashings and tapes required on the project and delete all others.
 
          2.3FLASHINGS AND TAPES
 
          A.R-SEAL 3000: Foil insulation flashing tape with acrylic pressure sensitive adhesive.
          1.Backing: 2mil Aluminum foil.
          ** NOTE TO SPECIFIER ** Select width and delete those not required on the project.
          2.Width: 4 inches (102mm).
          3.Width: 5 inches (127mm).
          4.Thickness: 3.4 mils (0.08mm).
 
          B.R-SEAL 3000W: Foil insulation flashing tape with acrylic pressure sensitive adhesive.
          1.Backing: 2mil White Aluminum foil.
          2.Width: 3 inches (76mm).
          3.Thickness: 3.8 mils (0.10mm).
 
          C.R-SEAL 6000: Woven polyethylene penetration flashing membrane with butyl rubber adhesive.
          1.Liner: Low Density Polyethylene (LDPE).
          ** NOTE TO SPECIFIER ** Select width and delete those not required on the project.
          2.Width: 9 inches (229mm).
          3.Width: 12 inches (305mm).
          4.Thickness: 35 mils (0.89mm).
 
          D.R-SEAL Construction Tape: Film insulation construction tape with acrylic pressure sensitive adhesive.
          1.Backing: 3mil White OPP film.
          2.Width: 3 inches (76mm).
          3.Thickness: 3.0 mils (0.076mm).
          ** NOTE TO SPECIFIER ** Designed for installation with TSX-8500, TSX-8510 or Thermasheath-XP exposed insulation or other code approved insulation. Retain only if required and delete all others
 
          2.4INSULATION CLIPS
 
          A.Flex-Tite Insulation Clips: Two piece (male/female) interlocking extrusions to seal insulation joints.
          1.Material: PVC Extrusions. UL Tested - Class A material, tested by Underwriters Laboratories (UL 723 - test for surface burning characteristics of building materials). Flame spread is 0 and smoke developed equals 190.
          2.Finish: White (standard).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          3.Insulation Thickness: 1.0 inches (25mm).
          a.Male Part #MA0100 and Female Part #FE0100.
          4.Insulation Thickness: 1.5 inches (38mm).
          a.Male Part #MA0150 and Female Part #FE0100.
          5.Insulation Thickness: 2.0 inches (51mm).
          a.Male Part #MA0200 and Female Part #FE0200.
          6.Insulation Thickness: 2.5 inches (64mm).
          a.Male Part #MA0155 and Female Part #FE0200.
          7.Insulation Thickness: 3.0 inches (276mm).
          a.Male Part #MA0200 and Female Part #FE0300.
          8.Insulation Thickness: 3.5 inches (89mm).
          a.Male Part #MA0155 and Female Part #FE0300.
          ** NOTE TO SPECIFIER ** Designed for installation with TSX-8500, TSX-8510 or Thermasheath-XP exposed insulation or other code approved insulation. Retain only if required and delete all others
 
          B.Quick Clip Insulation Retaining System: One piece extrusions to seal insulation joints.
          1.Material: PVC Extrusions. UL Tested - Class A material, tested by Underwriters Laboratories (UL 723 - test for surface burning characteristics of building materials). Flame spread is 0 and smoke developed equals 190.
          2.Finish: White (standard).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          3.Insulation Thickness: 1.0 inches (25mm)..
          a.Quick Clip Part # QC0100.
          4.Insulation Thickness: 1.5 inches (38mm)..
          a.Quick Clip Part # QC0150.
          5.Insulation Thickness: 2.0 inches (51mm)..
          a.Quick Clip Part # QC0200.
          6.Insulation Thickness: 2.5 inches (64mm)..
          a.Quick Clip Part # QC0250.
          7.Insulation Thickness: 3.0 inches (76mm)..
          a.Quick Clip Part # QC0300.
          ** NOTE TO SPECIFIER ** Designed for installation with TSX-8500, TSX-8510 or Thermasheath-XP exposed insulation or other code approved insulation. Retain only if required and delete all others
 
          C.J-Channel: Extruded shape to terminate exposed edges of installed insulation.
          1.Material: PVC Extrusions. UL Tested - Class A material, tested by Underwriters Laboratories (UL 723 - test for surface burning characteristics of building materials). Flame spread is 0 and smoke developed equals 190.
          2.Finish: White (standard).
          ** NOTE TO SPECIFIER ** Retain only thicknesses actually required on the project and delete all others.
          3.Insulation Thickness: 1.0 inches (25mm).
          a.J-Channel Part # JC0100
          4.Insulation Thickness: 1.5 inches (38mm).
          a.J-Channel Part # JC0150
          5.Insulation Thickness: 2.0 inches (51mm).
          a.J-Channel Part # JC0200
          6.Insulation Thickness: 2.5 inches (64mm).
          a.J-Channel Part # JC0250
          7.Insulation Thickness: 3.0 inches (76mm).
          a.J-Channel Part # JC0275
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          3.2PREPARATION
 
          A.Clean surfaces thoroughly prior to installation.
 
          B.Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION, GENERAL
 
          A.Install in accordance with manufacturer's instructions and in proper relationship with adjacent construction.
 
          3.4PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Touch-up, repair or replace damaged products before Substantial Completion.
 
         
END OF SECTION