SECTION 07 42 13
METAL WALL PANELS
 
 
Copyright 2018 - 2018 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** Morin
A Kingspan Group Co.; metal wall and wall systems.
This section is based on the products of Morin
A Kingspan Group Co., which is located at:
685 Middle St.
Bristol, CT 06010-8416
Toll Free Tel: 800-640-9501
Tel: 800-640-9501
Fax: 860-582-7503
Email: request info (sales@morincorp.com)
Web: www.morincorp.com
[ Click Here ] for additional information.
MORIN is one of the industry's most versatile manufacturers of single element metal wall and wall panel systems. With production facilities in Bristol, CT, Deland, FL and Fontana, CA, MORIN has a combined production capacity of over 50 million square feet, fabricating metal panels in more than 75 different profiles. MORIN Single Element panels are 100 percent recyclable and meet the requirements for the U.S. Green Building Council's (USGBC) Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Morin's nationwide sales network and in-house technical service teams are dedicated to providing innovative solutions for today's progressive architecture.
 
PART 1 GENERAL
 
1.1
SECTION INCLUDES
 
** NOTE TO SPECIFIER ** Delete items below not required for project.
 
A.
Concealed fastener single-skin metal wall panels installed using the back ventilated rain screen design principle.
1.
Concealed Fastener Series.
2.
Integrity Series.
3.
Matrix Series.
4.
Exposed Fastener Series.
B.
Structural standing seam horizontal or vertical metal wall panels. (Morzip Series)
C.
Concealed fastener single-skin perforated metal wall panels used as a screen wall. (Concealed Fastener Series)
D.
Structural standing seam metal wall panels. (SymmeTry Series)
E.
Single/double lock or Snaplock standing seam, single element metal wall panels. (SLR and SWL series)
1.2
RELATED SECTIONS
 
** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
A.
Section 05 10 00 - Structural Metal Framing.
B.
Section 05 40 00 - Cold-Formed Metal Framing.
C.
Section 07 21 26 - Blown Insulation.
D.
Section 07 27 26 - Fluid-Applied Membrane Air Barriers .
E.
Section 07 60 00 - Flashing and Sheet Metal.
F.
Section 07 90 00 - Joint Protection.
G.
Section 09 28 13 - Cementitious Backing Boards.
H.
Section 08 90 00 - Louvers and Vents.
1.3
REFERENCES
 
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
A.
ASTM International (ASTM):
1.
ASTM A240 - Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
2.
ASTM A641; Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire.
3.
ASTM A653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
4.
ASTM A666 - Standard Specification for Annealed or Cold-Worked Austenitic Stainless-Steel Sheet, Strip, Plate, and Flat Bar.
5.
ASTM A792 - Standard Specification for Steel Sheet, 55 percent Aluminum-Zinc Alloy-Coated by the Hot- Dip Process.
6.
ASTM B69 - Standard Specification for Rolled Zinc.
7.
ASTM B85 - Standard Specification for Aluminum Alloy Die Castings.
8.
ASTM B117 - Standard Practice for Operating Salt Spray (Fog) Apparatus.
9.
ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.
10.
ASTM B221 - Standard Specification for Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
11.
ASTM B370 - Standard Specification for Copper Sheet and Strip for Building Construction.
12.
ASTM C612 - Standard Specification for Mineral Fiber Block and Board Thermal Insulation.
13.
ASTM C645 - Standard Test Method for Nonstructural Steel Framing Members.
14.
ASTM C920 - Standard Specification for Elastomeric Joint Sealants.
15.
ASTM C1311 - Standard Specification for Solvent Release Sealants.
16.
ASTM D522 - Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings.
17.
ASTM D523 - Standard Test Method for Specular Gloss.
18.
ASTM D714 - Standard Test Method for Evaluating Degree of Blistering of Paints.
19.
ASTM D968 - Standard Test Methods for Abrasion Resistance of Organic Coatings by Falling Abrasive.
20.
ASTM D1308 - Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Organic Finishes.
21.
ASTM D2244 - Standard Standard practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates.
22.
ASTM D2247 - Standard Standard Practice for Testing Water Resistance of Coatings in 100 percent Relative Humidity.
23.
ASTM D2794 - Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact).
24.
ASTM D3359 - Standard Test Methods for Measuring Adhesion by Tape Test.
25.
ASTM D3363 - Standard Test Method for Film Hardness by Pencil Test.
26.
ASTM D4145 - Standard Test Method for Coating Flexibility of Prepainted Sheet.
27.
ASTM D4214 - Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films.
28.
ASTM D5894 - Standard Practice for Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a UV Condensation Cabinet).
29.
ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.
30.
ASTM E330; Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
31.
ASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.
32.
ASTM E1592 - Standard Test Method for Structural Performance of Sheet Metal Wall and Siding Systems by Uniform Static Air Pressure Difference.
33.
ASTM E1646 - Standard Test Method for Water Penetration of Exterior Metal Wall Panel Systems by Uniform Static Air Pressure Difference.
34.
ASTM E1680 - Standard Test Method for Rate of Air Leakage through Exterior Metal Wall Panel Systems.
35.
ASTM E2140-01 - Standard Test Method for Water Penetration of Metal Panel Wall Systems by Static Water Pressure Head.
36.
ASTM G153 - Standard Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials.
37.
ASTM G154 - Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials.
 
** NOTE TO SPECIFIER ** Delete if project is not in Florida.
 
B.
Florida Building Code. Testing Application Standard (TAS):
1.
TAS 201 - Impact Test Procedures.
2.
TAS 202 - Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components using Uniform Static Air Pressure.
3.
TAS 203 - Criteria for Testing Products subject to Cyclic Wind Pressure Loading.
C.
German Institute for Standardization (DIN):
1.
DIN EN988 - Specifications for zinc and zinc alloy rolled flat products for building.
2.
DIN EN1179 - Zinc and Zinc alloys - Primary Zinc.
D.
Southern Building Code Conference International (SBCCI):
1.
SBCCI Standard 12-99; Standard for Determining the Wind Resistance from Windborne Debris.
1.4
SUBMITTALS
A.
Submit under provisions of Section 01 30 00 - Administrative Requirements.
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
1.
Design Data, Test Reports: Provide manufacturer test reports indicating product compliance with requirements.
2.
Preparation instructions and recommendations.
3.
Storage and handling requirements and recommendations.
4.
Installation methods.
C.
Shop Drawings: Show Profile, gauge of exterior and interior sheets, location, layout and dimensions of panels, location and type of fasteners, shape and method of trim attachment, sealant locations and types, and installation sequence.
1.
Coordination Drawings: Provide elevation drawings and building sections which show panels in relationship to required locations for structural support. Include panel details and details showing attachment to structural support.
2.
Other details as may be required for a weathertight installation.
D.
Panel Analysis: Withstand design loads without detrimental effects or deflection, thermal effects between exterior and interior panel facings, and resistance to fastener pullout.
E.
Verification Samples: Two samples, representing actual product, color, and patterns.
 
** NOTE TO SPECIFIER ** Delete LEED submittal requirements when project is not pursuing LEED certification. Related to Innovation and Design process (ID) credits; contact Kingspan for assistance in developing credits where their products can assist in obtaining.
 
F.
LEED Submittals:
1.
Material and Resources (MR): For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content.
 
** NOTE TO SPECIFIER ** Delete credits no required.
 
a.
Product Certificates for Credit MR 4.
b.
Product Certificates for Credit MR 4.1.
c.
Product Certification for Credit MR 4.2.
G.
Miscellaneous Certifications: Submit documentation that products have been certified in accordance with ISO 14025.
H.
Quality Assurance Submittals:
 
** NOTE TO SPECIFIER ** Delete Design Data, Test Report submittal requirements when a proprietary specification is used. Maintain Design Data, Test Report submittal requirement when other products may be submitted as substitutions.
 
1.
Design Data, Test Reports: Indicating product compliance with requirements.
2.
Manufacturer Erection Instructions: Written installation instructions including material storage and handling, installation sequence, panel locations, attachment methods, details, and required trim and accessories.
1.5
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Ten years experience in the production of metal wall panels.
B.
Installer Qualifications: Work supervised by person authorized by manufacturer.
 
** NOTE TO SPECIFIER ** Delete if not required. Applies directly for MorZip.
 
1.
Installer: Five years experience with projects of similar size and scope.
 
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project. Delete if not required.
 
C.
Mock-Up: For evaluation of surface preparation techniques and application workmanship.
1.
Finish areas designated by Architect.
2.
Install one complete, operable unit including accessories, then test operation and make adjustments required for proper operation.
3.
Do not proceed with remaining work until workmanship is approved by Architect.
4.
Rebuild mock-up area as required to produce acceptable work.
1.6
PRE-INSTALLATION MEETINGS
A.
Pre-installation meeting: At job site. Attended by Owner, Architect, Manufacturer's Technical Representative, Panel Installer, and Contractors of related trades. Coordinate structural support requirements in relation to wall panel panel system, installation of any separate air/water barriers, treatment of fenestration, and other project requirements.
1.7
DELIVERY, STORAGE, AND HANDLING
A.
Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation.
B.
Store panel materials on dry, level, firm, and clean surface. Stack no more than two bundles high. Elevate one end of bundle to allow moisture run-off, cover and ventilate to allow air to circulate and moisture to escape.
1.8
PROJECT CONDITIONS
A.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.
1.9
SEQUENCING
A.
Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.
1.10
WARRANTY
A.
Warranty: Provide manufacturer's standard limited warranties for products and finishes
 
.** NOTE TO SPECIFIER ** Delete warranty information not specific to project.
 
1.
Material Warranty: Manufacturer agrees to repair or replace items that fail in materials or workmanship within warranty period. Items covered by the warranty include structural performance and finish performance.
a.
Warranty Period: Two years from date of Substantial Completion.
 
** NOTE TO SPECIFIER ** Finish warranty periods are limited by the coil coater and the coating manufacturer and the finish. Delete if fluoropolymer finish is not required.
 
2.
Finish Warranty: Manufacturer agrees to repair or replace metal panels that evidence deterioration of fluoropolymer finish, including flaking or peeling from approved primed metal substrate, chalk in excess of 8 when tested in accordance with ASTM D4214, Method A, and /or color fading in excess of 5 Delta E Hunter units on panels when tested in accordance with ASTM D2244.
a.
Warranty Period: Twenty years from date Substantial Completion, or twenty years and 3 months from date of shipment from manufacturer's plant. whichever occurs first.
PART 2 PRODUCTS
 
2.1
MANUFACTURERS
A.
Acceptable Manufacturer: Morin; A Kingspan Group Co., which is located at: 685 Middle St.; Bristol, CT 06010-8416 ; Toll Free Tel: 800-640-9501; Tel: 800-640-9501 ; Fax: 860-582-7503; Email: request info (sales@morincorp.com); Web: www.morincorp.com
 
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.2
CONCEALED FASTENER SINGLE-SKIN METAL WALL PANELS (Concealed Fastener Series)
A.
Performance Criteria:
 
** NOTE TO SPECIFIER ** Structural Performance testing based on ASTM E330 applies only to wall panel profile F-12, 20 gauge steel.
 
1.
Structural Performance: Testing shall be done based on ASTM E330:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits options not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/180 of the span.
e.
Horizontal Deflection Limits: No greater than L/240 of the span.
 
** NOTE TO SPECIFIER ** Air and Water Performance testing based on ASTM E283, E331 applies only to wall panel profiles A-12, F-12 and N-12; 24 gauge steel.
 
2.
Air Infiltration Tested per ASTM E283: 0.010 cu ft per min per sq ft (0.003 cu m per min per sq m) of fixed wall area. Static air-pressure differential of 1.57 ft-lbs per sq ft (22.91 Nm per sq m).
3.
Water Penetration under Static Pressure Tested per ASTM E331: 6.0 lbs per sq ft (29.29 kg per sq m).
B.
Basis of Design: Concealed Fastener Single Skin Metal Wall Panels as manufactured by Morin, a Kingspan Group Company.
1.
Wall Panel Description:
a.
Panel Thickness: 1-1/2 in (38 mm) thick.
b.
Panel Joint: Tongue and groove interlock joint.
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
c.
Panel Width: 12 in (305 mm).
d.
Panel Width: 16 in (406 mm).
e.
Panel Width: 18 in (457 mm).
f.
Panel Width: 22 in (559 mm).
g.
Panel Width: 24 in (610 mm).
 
** NOTE TO SPECIFIER ** Delete profile option not required. See detailed manufacturer information for profile designations; https://www.kingspan.com/us/en-us/product-groups/metal-roof-wall-systems/wall-systems/concealed-fasteners
 
h.
Profile: ______.
i.
Profile: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete texture option no required.
 
j.
Texture: Smooth
k.
Texture: Non-directional embossed.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
l.
Steel: Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
m.
1.)Gauge: 24; 0.0276 in (0.70 mm).
n.
2.)Gauge: 22; 0.0336 in (0.85 mm).
o.
3.)Gauge: 20; 0.0396 in (1.01 mm).
p.
4.)Gauge: 18; 0.0516 in (1.31 mm).
q.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
r.
1.)Thickness: 0.032 in (0.81 mm).
s.
2.)Thickness: 0.040 in (1.02 mm).
t.
3.)Thickness: 0.050 in (1.27 mm).
u.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
v.
1.)Gauge: 24; 0.025 in (0.64 mm).
w.
2.)Gauge: 22; 0.0312 in (0.79 mm).
x.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
 
** NOTE TO SPECIFIER ** Delete weight option not required.
 
y.
1.)Weight: 16 oz per sq ft (4.88 kg per sq m).
z.
2.)Weight: 20 oz per sq ft (6.1 kg per sq m).
aa.
Zinc Sheets: Sheet stock meeting DIN EN1179, consisting of Zinc with copper and titanium additives in accordance with DIN EN988.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
ab.
1.)Thickness: 0.0315 in (0.800 mm).
ac.
2.)Thickness: 0.0394 in (1.000 mm).
ad.
3.)Thickness: 0.0472 in (1.200 mm).
 
** NOTE TO SPECIFIER ** Delete if liner panels are not required.
 
2.
Liner Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width option not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 24 in (610 mm).
 
NOTE TO SPECIFIER ** See manufacturer's detailed information for liner panel series available.
 
c.
1.)Liner Panel Series: ______.
d.
2.)Liner Panel Series: As indicated on Drawings.
C.
Accessories: As required for a complete installation and indicated on approved shop drawings, per manufacturer's approved details. Match material and finish of wall panels.
1.
Closure Strips; Metal Profile: Same gauge, material and finish as panel.
2.
Swedged Ends: Factory crimped end laps.
 
** NOTE TO SPECIFIER ** Delete trim option not required.
 
2.
Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim. Same material, thickness and finish as wall panels. Including but not limited to: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
3.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot-dip galvanized option not required.
 
4.
1.)Hot-Dip Galvanized: ASTM A653, G40.
5.
2.)Hot-Dip Galvanized: ASTM A653, G60.
a.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
b.
1.)Nominal Thickness: 0.025 in (0.063 mm)
c.
2.)Nominal Thickness: 0.040 in (1.02 mm)
d.
3.)Nominal Thickness (in/mm): ______.
e.
4.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
f.
5.)Depth: 7/8 in (22 mm).
g.
6.)Depth: 1-1/2 in (38 mm).
h.
7.)Depth (in/mm): ______.
i.
8.)Depth: As indicated on Drawings.
j.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
k.
1.)Nominal Thickness: 0.064 in (1.63 mm).
l.
2.)Nominal Thickness (in/mm): ______.
m.
3.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
n.
4.)Depth: 3/4 in (19 mm).
o.
5.)Depth (in/mm): ______.
p.
6.)Depth: As indicated on Drawings.
q.
Furring Brackets: Adjustable, corrugated-edge type of steel sheet with 0.040 in (1.02 mm) nominal thickness.
r.
Tie Wire: ASTM A641, Class 1 zinc coating, soft temper, 0.062 in (1.57 mm) diameter wire, or double strand of 0.048 in (1.22 mm) diameter wire.
6.
Panel Sealant:
 
** NOTE TO SPECIFIER ** Sealant is not required for rains screen applications. For non-rain screen applications sealant can either be site applied or factory applied to panel joints.
 
a.
Joint Sealant: ASTM C920 as recommended in writing by panel manufacturer.
b.
Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C1311.
D.
Fabrication: Factory formed to lap and interconnect with edges of adjacent panels. Mechanically attached to supports using concealed fasteners. Fabricate to eliminate condensation on interior side of panel. Joints between panels form weathertight seals.
1.
Sealant: At panel joints to seal and minimize noise from panel movements.
 
** NOTE TO SPECIFIER ** Delete one of the two following paragraphs.
 
a.
Factory installed.
b.
Site applied.
 
** NOTE TO SPECIFIER ** Delete trim accessories option not required or delete both if trim is specified in a different section.
 
2.
Trim Accessories: Comply with recommendations in SMACNA's "Architectural Sheet Metal Manual".
3.
Trim Accessories: Provide manufacturer's standard extruded aluminum trim.
 
** NOTE TO SPECIFIER ** Delete factory fabricated mitered corners if trim covered corners are chosen.
 
4.
Mitered Corners: Outside and inside corners matching metal wall panel material, profile and factory applied finish. Fabricated by wall panel manufacturer.
 
** NOTE TO SPECIFIER ** Delete soffit panels option not required or both if soffits are not required.
 
5.
Soffit panels shall be perforated.
6.
Soffit panels shall be non-perforated.
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color indicated.
 
** NOTE TO SPECIFIERS ** Delete one of the two following paragraphs.
 
d.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
e.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
f.
a.)Primer: 0.2 mil (0.0051 mm).
g.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
h.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
i.
a.)Primer: 0.2 mil (0.0051 mm).
j.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
k.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
l.
a.)Primer: 0.2 mil (0.0051 mm).
m.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
n.
c.)Clear Coat: 0.5 mil (0.0127 mm).
o.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
p.
a.)Primer: 0.8 mil (0.0203 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
r.
c.)Clear Coat: 0.8 mil (0.0203 mm).
s.
Exterior Aggregate Finish: Baked epoxy primer with finish coat of acrylic bonder and silica or quartz aggregate.
 
** NOTE TO SPECIFIER ** Silica Aggregate Colors are applied at 12 mils dry film thickness and Quartz Aggregate Colors are applied at 36 mils dry film thickness. Delete dry film thickness option not required.
 
t.
1.)Dry Film Thickness: Factory applied 12 mil (0.305 mm). Silica aggregate.
u.
2.)Dry Film Thickness: Factory applied 36 mil (0.914 mm) Quartz aggregate.
 
** NOTE TO SPECIFIER ** Delete color options not required.
 
v.
3.)Silica Aggregate Color: Selected from manufacturer's selection.
w.
4.)Silica Aggregate Color: As indicate on the Drawings.
x.
5.)Quartz Aggregate Color: Selected from manufacturer's selection.
y.
6.)Quartz Aggregate Color: As indicate on the Drawings.
2.
Exposed Aluminum-Zinc Alloy-Coating; ASTM A792, Class AZ50 coating. "Galvalume" or "Zincalume"protective coating.
3.
Stainless Steel: Dull, cold rolled, IID.
4.
Stainless Steel: Bright, cold rolled, IIB.
5.
Stainless Steel: Polished directional satin, 4.
6.
Copper: Natural.
7.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Perforated panels are optional. Delete if not required.
 
F.
Perforated Panels:
1.
Fabrication: Aluminum construction.
2.
Fabrication: Stainless steel construction.
3.
Perforation Pattern: ______.
4.
Perforation Pattern: As selected by the Architect.
a.
Open Area: 10 to 40 percent; dependent on hole sizing and spacing.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.3
CONCEALED FASTENER SINGLE-SKIN METAL WALL PANELS (Integrity Series)
A.
Performance Criteria:
 
** NOTE TO SPECIFIER ** Structural Performance testing based on ASTM E1592 applies only to wall panel profiles S-16 and XAB-16; 24 gauge steel, and 0.032 and 0.040 inch aluminum.
 
1.
Structural Performance: Testing shall be done based on ASTM E1592:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits options not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/180 of the span.
e.
Horizontal Deflection Limits: No greater than L/240 of the span.
2.
Air Infiltration Tested per ASTM E283: 0.010 cu ft per min per sq ft (0.003 cu m per min per sq m) of fixed wall area. Static air-pressure differential of 1.57 ft-lbs per sq ft (22.91 Nm per sq m).
3.
Water Penetration under Static Pressure Tested per ASTM E331: 6.0 lbs per sq ft (29.29 kg per sq m).
B.
Basis of Design: Integrity Series Concealed Fastener Single Skin Metal Wall Panels as manufactured by Morin, a Kingspan Group Company.
1.
Wall Panel Description:
a.
Panel Thickness: 1-1/2 in (38 mm) thick.
b.
Panel Joint: Tongue and groove interlock joint.
 
** NOTE TO SPECIFIER ** Delete panel width option not required.
 
c.
Panel Width: 12 in (305 mm).
d.
Panel Width: 16 in (406 mm).
 
** NOTE TO SPECIFIER ** Delete profile option not required. See detailed manufacturer information for profile designations; https://www.kingspan.com/us/en-us/product-groups/metal-roof-wall-systems/wall-systems/integrity-series
 
e.
Profile: ______.
f.
Profile: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete texture option no required.
 
g.
Texture: Smooth.
h.
Texture: Non-directional embossed.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
i.
Steel: Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
j.
1.)Gauge: 24; 0.0276 in (0.70 mm).
k.
2.)Gauge: 22; 0.0336 in (0.85 mm).
l.
3.)Gauge: 20; 0.0396 in (1.01 mm).
m.
4.)Gauge: 18; 0.0516 in (1.31 mm).
n.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
o.
1.)Thickness: 0.032 in (0.81 mm).
p.
2.)Thickness: 0.040 in (1.02 mm).
q.
3.)Thickness: 0.050 in (1.27 mm).
r.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
s.
1.)Gauge: 24; 0.025 in (0.64 mm).
t.
2.)Gauge: 22; 0.0312 in (0.79 mm).
u.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
 
** NOTE TO SPECIFIER ** Delete weight option not required.
 
v.
1.)Weight: 16 oz per sq ft (4.88 kg per sq m).
w.
2.)Weight: 20 oz per sq ft (6.1 kg per sq m).
x.
Zinc Sheets: Sheet stock meeting DIN EN1179, consisting of Zinc with copper and titanium additives in accordance with DIN EN988.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
y.
1.)Thickness: 0.0315 in (0.800 mm).
z.
2.)Thickness: 0.0394 in (1.000 mm).
 
** NOTE TO SPECIFIER ** Delete if liner panels are not required.
 
2.
Liner Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width option not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 24 in (610 mm).
 
NOTE TO SPECIFIER ** See manufacturer's detailed information for liner panel series available.
 
c.
1.)Liner Panel Series: ______.
d.
2.)Liner Panel Series: As indicated on Drawings.
C.
Accessories: As required for a complete installation and indicated on approved shop drawings, per manufacturer's approved details. Match material and finish of wall panels.
1.
Closure Strips; Closed Cell: Minimum 1 in (25 mm) thick matching wall panel profile.
2.
Closure Strips; Metal Profile: Same gauge, material and finish as panel.
 
** NOTE TO SPECIFIER ** 18 gauge clips are used to attach steel panels; 20 gauge stainless steel clips are used to attach aluminum or zinc panels. Delete concealed clip option not required.
 
3.
Concealed Clips: 18 gauge (1.31 mm); galvanized steel: ASTM A653, G90.
4.
Concealed Clips: 20 gauge (0.95 mm); ASTM A240 or ASTM A666, Type 304, dead soft, fully annealed.
 
** NOTE TO SPECIFIER ** Delete trim option not required.
 
5.
Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
6.
Trim: Same material, thickness and finish as wall panels.
7.
Trim Locations: Include, but not limited to: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
8.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot-dip galvanized option not required.
 
9.
1.)Hot-Dip Galvanized: ASTM A653, G40.
10.
2.)Hot-Dip Galvanized: ASTM A653, G60.
a.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
b.
1.)Gauge: 18; 0.0478 in (1.21 mm).
c.
2.)Gauge: 16; 0.0598 in (1.52 mm).
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
d.
3.)Depth: 1/2 in (13 mm).
e.
4.)Depth: 1 in (25 mm).
f.
5.)Depth (in/mm): ______.
g.
6.)Depth: As indicated on Drawings.
h.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
i.
1.)Nominal Thickness: 18 Gauge; 0.0478 in (1.21 mm).
j.
2.)Nominal Thickness: 16 Gauge; 0.0598 in (1.52 m).
k.
3.)Nominal Thickness (in/mm): ______.
l.
4.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth option not required
 
m.
5.)Depth (in/mm): ______.
n.
6.)Depth: As indicated on Drawings.
11.
Panel Sealant:
 
** NOTE TO SPECIFIER ** Sealant is not required for rain screen applications. For non-rain screen applications sealant can either be site applied or factory applied to panel joints.
 
a.
Joint Sealant: ASTM C920 as recommended in writing by panel manufacturer.
b.
Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C1311.
12.
Fasteners: Self-tapping stainless-steel screws, bolts, nuts, self-locking rivets and bolts, and other suitable fasteners designed to withstand design loads.
D.
Fabrication: Factory formed to lap and interconnect with edges of adjacent panels. Mechanically attached to supports using concealed fasteners. Fabricate to eliminate condensation on interior side of panel. Joints between panels form weathertight seals.
1.
Sealant: At panel joints to seal and minimize noise from panel movements.
 
** NOTE TO SPECIFIER ** Delete one of the two following paragraphs.
 
a.
Factory installed.
b.
Site applied.
 
** NOTE TO SPECIFIER ** Delete curved wall panels if not required.
 
2.
Curved wall panels: Panels shall be factory curved as approved by manufacturer.
 
** NOTE TO SPECIFIER ** Delete trim accessories option not required or delete both if trim is specified in a different section.
 
3.
Trim Accessories: Fabricate complying with recommendations in SMACNA's "Architectural Sheet Metal Manual".
4.
Trim Accessories: Provide manufacturer's standard extruded aluminum trim.
 
** NOTE TO SPECIFIER ** Delete factory fabricated mitered corners if trim covered corners are chosen.
 
5.
Mitered Corners: Structurally bonded horizontal outside or inside trimless corners matching metal wall panel material, profile and factory applied finish. Fabricated by wall panel manufacturer.
a.
Basis of Design: Morin Miterseam Corners 24 x 24 in (610 x 610 mm).
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material and finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect
c.
Finish and Color; Exposed Surface: Color indicated.
d.
Finish System
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid Color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) Metallic color coat systems are chosen if premium colors are desired. The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
e.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
f.
a.)Primer: 0.2 mil (0.0051 mm).
g.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
h.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
i.
a.)Primer: 0.2 mil (0.0051 mm).
j.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
k.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
l.
a.)Primer: 0.2 mil (0.0051 mm).
m.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
n.
c.)Clear Coat: 0.5 mil (0.0127 mm).
2.
Exposed Aluminum-Zinc Alloy-Coating; ASTM A792, Class AZ50 coating. "Galvalume" or "Zincalume"protective coating.
3.
Stainless Steel: Dull, cold rolled, IID.
4.
Stainless Steel: Bright, cold rolled, IIB.
5.
Stainless Steel: Polished directional satin, 4.
6.
Copper: Natural.
7.
Copper: Acid patina.
8.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Perforated panels are optional. Delete if not required.
 
F.
Perforated Panels:
1.
Fabrication: Aluminum construction.
2.
Fabrication: Stainless steel construction.
3.
Perforation Pattern: ______.
4.
Perforation Pattern: As selected by the Architect.
a.
Open Area: 10 to 40 percent; dependent on hole sizing and spacing.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.4
CONCEALED FASTENER SINGLE-SKIN METAL WALL PANELS (Matrix Series)
A.
Performance Criteria:
1.
Structural Performance: Testing shall be done based on ASTM E1592:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits options not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/180 of the span.
e.
Horizontal Deflection Limits: No greater than L/240 of the span.
2.
Air Infiltration Tested per ASTM E283: 0.010 cu ft per min per sq ft (0.003 cu m per min per sq m) of fixed wall area. Static air-pressure differential of 1.57 ft-lbs per sq ft (22.91 Nm per sq m).
3.
Water Penetration under Static Pressure Tested per ASTM E331: 6.0 lbs per sq ft (29.29 kg per sq m).
B.
Basis of Design: Matrix Series Concealed Fastener Single Skin Metal Wall Panels as manufactured by Morin, a Kingspan Group Company.
1.
Wall Panel Description:
a.
Panel Thickness: 1-1/2 in (38 mm) thick.
b.
Panel Joint: Tongue and groove interlock joint.
c.
Panel Width: 12 in (305 mm).
 
** NOTE TO SPECIFIER ** Delete profile option not required. See detailed manufacturer information for profile designations; https://www.kingspan.com/us/en-us/product-groups/metal-roof-wall-systems/wall-systems/matrix-series
 
d.
Profile: ______.
e.
Profile: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
f.
Texture: Smooth.
g.
Texture: Non-directional embossed.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
h.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness option not required.
 
i.
1.)Thickness: 0.040 in (1.02 mm)
j.
2.)Thickness: 0.050 in (1.27 mm).
k.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
l.
1.)Gauge: 24; 0.025 in (0.64 mm).
m.
2.)Gauge: 22; 0312 in (0.79 mm).
n.
Zinc Sheets: Sheet stock meeting DIN EN1179, consisting of Zinc with copper and titanium additives in accordance with DIN EN988.
 
** NOTE TO SPECIFIER ** Delete thickness option not required.
 
o.
1.)Weight: 0.0315 in (0.800 mm).
p.
2.)Weight: 0.0394 in (1.000 mm).
 
** NOTE TO SPECIFIER ** Delete if liner panels are not used.
 
2.
Liner Panel Description:
 
** NOTE TO SPECIFIER ** Delete panels width option not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 24 in (610 mm).
 
** NOTE TO SPECIFIER ** See manufacturer's detailed information for linear panel series available.
 
c.
1.)Linear Panel Series: ______.
d.
2.)Liner Panel Series: As indicated on Drawings.
C.
Accessories: As required for a complete installation and indicated on approved shop drawings and per manufacturer's approved details. Match material and finish of wall panels.
1.
Closure Strips; Closed Cell: Minimum 1 in (25 mm) thick matching wall panel profile.
2.
Closure Strips; Metal Profile: Same gauge, material and finish as panel.
 
** NOTE TO SPECIFIER ** 18 gauge clips are used in attachment of steel panels; 20 gauge stainless steel clips are used in attachment of aluminum or zinc panels. Delete concealed clip option not required.
 
3.
Concealed Clips: 18 gauge (1.31 mm); galvanized steel: ASTM A653, G90.
4.
Concealed Clips: 20 gauge (0.95 mm); ASTM A240 or ASTM A666, Type 304, dead soft, fully annealed.
5.
Panel Reveal Trim: Extruded aluminum 6063-T5, 0.078 in (1.98 mm) thick.
 
** NOTE TO SPECIFIER ** Delete profile options not required.
 
a.
Profile: MX 1.0 where shown on Drawings.
b.
Profile: MX 2.0 where shown on Drawings.
c.
Profile: MX 3.0 where shown on Drawings.
 
** NOTE TO SPECIFIER ** Delete trim option not required.
 
6.
Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
7.
Trim: Same material, thickness and finish as wall panels.
8.
Trim Locations: Include, but not limited to: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
9.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot-dip galvanized option not required.
 
a.
Hot-Dip Galvanized: ASTM A653, G40.
b.
Hot-Dip Galvanized: ASTM A653, G60.
c.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
d.
1.)Gauge: 18; 0.0478 in (1.21 mm).
e.
2.)Gauge: 16; 0.0598 in (1.52 mm).
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
f.
3.)Depth: 1/2 in (13 mm).
g.
4.)Depth: 1 in (25 mm).
h.
5.)Depth (in/mm): ______.
i.
6.)Depth: As indicated on Drawings.
j.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
k.
1.)Nominal Thickness: 18 Gauge; 0.0478 in (1.21 mm).
l.
2.)Nominal Thickness: 16 Gauge; 0.0598 in (1.52 m).
m.
3.)Nominal Thickness (in/mm): ______.
n.
4.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth option not required
 
o.
5.)Depth (in/mm): ______.
p.
6.)Depth: As indicated on Drawings.
10.
Fasteners: Self-tapping stainless-steel screws, bolts, nuts, self-locking rivets and bolts, and other suitable fasteners designed to withstand design loads.
D.
Fabrication: Panels factory formed to lap and interconnect with edges of adjacent panels. Mechanically attached to supports using concealed fasteners. Fabricate to eliminate condensation on interior side of panel. Joints between panels form weathertight seals.
 
** NOTE TO SPECIFIER ** Delete trim accessories option not required or delete both if trim is specified in a different section.
 
1.
Trim Accessories: Fabricate complying with recommendations in SMACNA's "Architectural Sheet Metal Manual".
2.
Trim Accessories: Provide manufacturer's standard extruded aluminum trim.
 
** NOTE TO SPECIFIER ** Delete factory fabricated mitered corners if trim covered corners are chosen.
 
3.
Mitered Corners: Structurally bonded horizontal outside or inside trimless corners matching metal wall panel material, profile and factory applied finish. Fabricated by wall panel manufacturer.
a.
Basis of Design: Morin Miterseam Corners 24 x 24 in (610 x 610 mm).
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material and finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect
c.
Finish and Color; Exposed Surface: Color indicated.
d.
Finish System
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid Color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) Metallic color coat systems are chosen if premium colors are desired. The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
e.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
f.
a.)Primer: 0.2 mil (0.0051 mm).
g.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
h.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
i.
a.)Primer: 0.2 mil (0.0051 mm).
j.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
k.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
l.
a.)Primer: 0.2 mil (0.0051 mm).
m.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
n.
c.)Clear Coat: 0.5 mil (0.0127 mm).
2.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Perforated panels are optional. Delete if not required.
 
F.
Perforated Panels:
1.
Fabrication: Aluminum construction.
2.
Fabrication: Stainless steel construction.
3.
Perforation Pattern: ______.
4.
Perforation Pattern: As selected by the Architect.
a.
Open Area: 10 to 40 percent; dependent on hole sizing and spacing.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.5
EXPOSED FASTENER SINGLE-SKIN METAL WALL PANELS (Exposed Fastener Series)
A.
Performance Criteria:
 
** NOTE TO SPECIFIER ** Structural Performance testing based on ASTM E330 applies only to wall panel profile Y-36, 20 and 22 gauge steel.
 
1.
Structural Performance: Testing shall be done based on ASTM E330:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits options not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/180 of the span.
e.
Horizontal Deflection Limits: No greater than L/240 of the span.
 
** NOTE TO SPECIFIER ** Air and Water Performance testing based on ASTM E331 and ASTM E283 applies only to wall panel profiles MR, BR, E, O and Y; 24 gauge steel.
 
2.
Air Infiltration Tested per ASTM E283: 0.010 cu ft per min per sq ft (0.003 cu m per min per sq m) of fixed wall area. Static air-pressure differential of 1.57 ft-lbs per sq ft (22.91 Nm per sq m).
3.
Water Penetration under Static Pressure Tested per ASTM E331: 6.0 lbs per sq ft (29.29 kg per sq m).
 
** NOTE TO SPECIFIER ** Delete paragraph below if project is not in a hurricane zone. Performance testing based on TAS 201, 202, and 203 applies to wall panel profiles BR-28S, C-29-7/8, C-37-7/8 and O-24S; 20 and 22 gauge steel.
 
4.
Panels shall successfully pass test standards TAS 201, 202, and 203 to demonstrate suitability for high velocity hurricane zone applications with windborne debris.
5.
Finish Characteristics:
a.
Gloss per ASTM D523: 15 plus or minus 5.
b.
Pencil Hardness per ASTM D3363: HB - H.
c.
Flexibility, T-Bend per ASTM D4145: 1-2T bend.
d.
Flexibility, Mandrel per ASTM D522: No cracking.
e.
Adhesion per ASTM D3359: No adhesion loss.
f.
Reverse Impact per ASTM D2794: No cracking or adhesion loss.
g.
Abrasion Resistance per ASTM D968: 65 plus or minus 10 liters.
h.
Graffiti Resistance: Minimal effect.
i.
Acid Pollutant Resistance per ASTM D1308: No effect.
j.
Salt Fog Resistance per ASTM B117: Passes 1000 hours.
k.
Cyclic Salt Fog and UV Exposure per ASTM D5894: Passes 2016 hours.
l.
Humidity Resistance per ASTM D2247 and D714: Passes 1500 hours.
m.
Color Retention per ASTM G153 and G154: Passes 5000 hours.
n.
Chalk Resistance per ASTM D4214, Method A: Maximum chalk is a rating of 8.
o.
Color Tolerances per ASTM D2244: Greater than 5DELTA_SYMBOLE units on panels.
B.
Basis of Design: Exposed Fastener Single Skin Metal Wall Panels as manufactured by Morin, a Kingspan Group Company.
1.
Wall Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
a.
Panel Width: 24 in (610 mm); Thickness: 4 in (102 mm).
b.
Panel Width: 28 in (711 mm); Thickness: 1-1/2 in (38 mm).
c.
Panel Width: 29 in (737 mm); Thickness: 1-1/2 in (38 mm).
d.
Panel Width: 29-5/8 in (752 mm); Thickness: 7/8 in (22 mm).
e.
Panel Width: 30 in (762 mm); Thickness: 1 in (25 mm).
f.
Panel Width: 34 1/8 in (867 mm); Thickness: 1-3/4 in (44 mm).
g.
Panel Width: 35 in (889 mm); Thickness: 1-1/2 in (38 mm).
h.
Panel Width: 36 in (914 mm); Thickness: 1-1/2 in (38 mm).
i.
Panel Width: 37-5/16 in (948 mm); Thickness: 7/8 in (22 mm).
j.
Panel Width: 40 in (1016 mm); Thickness: 1 in (25 mm).
k.
Panel Width: 40 in (1016 mm); Thickness: 1/2 in (13 mm).
 
** NOTE TO SPECIFIER ** Delete profile option not required. See detailed manufacturer information for profile designations; https://www.kingspan.com/us/en-us/product-groups/metal-roof-wall-systems/wall-systems/exposed-fasteners
 
l.
Profile: ______.
m.
Profile: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
n.
Texture: Smooth.
o.
Texture: Non-directional embossed.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
p.
Steel: Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
q.
1.)Gauge: 22; 0.0336 in (0.85 mm).
r.
2.)Gauge: 20; 0.0396 in (1.01 mm).
s.
3.)Gauge: 18; 0.0516 in (1.31 mm).
t.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
u.
1.)Thickness: 0.032 in (0.81 mm).
v.
2.)Thickness: 0.040 in (1.02 mm).
w.
3.)Thickness: 0.050 in (1.27 mm).
x.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
y.
1.)Gauge: 24; 0.025 in (0.64 mm).
z.
2.)Gauge: 22; 0.0312 in (0.79 mm).
aa.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
 
** NOTE TO SPECIFIER ** Delete weight option not required.
 
ab.
1.)Weight: 16 oz per sq ft (4.88 kg per sq m).
ac.
2.)Weight: 20 oz per sq ft (6.1 kg per sq m).
ad.
Zinc Sheets: Sheet stock meeting DIN EN1179, consisting of Zinc with copper and titanium additives in accordance with DIN EN988.
 
** NOTE TO SPECIFIER ** Delete thickness options not required.
 
ae.
1.)Thickness: 0.0315 in (0.800 mm).
af.
2.)Thickness: 0.0394 in (1.000 mm).
ag.
3.)Thickness: 0.0472 in (1.200 mm).
 
** NOTE TO SPECIFIER ** Delete if liner panels are not required.
 
2.
Liner Panel Description:
 
** NOTE TO SPECIFIER ** Delete panels width option not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 24 in (610 mm).
 
** NOTE TO SPECIFIER ** See manufacturer's detailed information for liner panel series available. Delete liner panel series option not required.
 
c.
1.)Linear Panel Series: ______.
d.
2.)Liner Panel Series: As indicated on Drawings.
C.
Accessories: As required for a complete installation and indicated on approved shop drawings, per manufacturer's approved details. Match material and finish of wall panels.
1.
Fasteners with neoprene washers as recommended by manufacturer. Fastener head shall match exposed panel color.
2.
Closure Strips; Closed Cell: Minimum 1 in (25 mm) thick matching wall panel profile.
3.
Closure Strips; Metal Profile: Same gauge, material and finish as panel.
 
** NOTE TO SPECIFIER ** Delete trim options not required.
 
4.
Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
5.
Trim: Same material, thickness and finish as wall panels.
6.
Trim: Extruded, 3/4 in (19 mm) deep aluminum 6063-T5. Spray applied PVF coating, same color as wall panel.
7.
Trim Locations: Include, but are not limited to the following: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
8.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot-dip galvanized option not required.
 
9.
1.)Hot-Dip Galvanized: ASTM A653, G40.
10.
2.)Hot-Dip Galvanized: ASTM A653, G60.
a.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
b.
1.)Gauge: 18; 0.0478 in (1.21 mm).
c.
2.)Gauge: 16; 0.0598 in (1.52 mm).
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
d.
3.)Depth: 1/2 in (13 mm).
e.
4.)Depth: 1 in (25 mm).
f.
5.)Depth (in/mm): ______.
g.
6.)Depth: As indicated on Drawings.
h.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
i.
1.)Nominal Thickness: 18 Gauge; 0.0478 in (1.21 mm).
j.
2.)Nominal Thickness: 16 Gauge; 0.0598 in (1.52 m).
 
** NOTE TO SPECIFIER ** Delete depth option not required
 
k.
3.)Depth (in/mm): ______.
l.
4.)Depth: As indicated on Drawings.
11.
Panel Sealant:
 
** NOTE TO SPECIFIER ** Sealant tape and butyl sealant is not required for rain screen applications. Sealant is required at joints between wall panels and adjacent building components.
 
a.
Joint Sealant: ASTM C920 as recommended in writing by metal wall panel manufacturer.
b.
Sealant Tape: Pressure-sensitive, 100 percent solids, gray polyisobutylene compound sealant tape with release-paper backing; 1/8 in (3 mm) wide and 1/8 in (3 mm) thick.
c.
Butyl-Rubber-Based, Solvent-Release Sealant per ASTM C1311.
D.
Fabrication: Panels factory formed to lap with edges of adjacent panels. Mechanically attached through panel to supports using fasteners with a neoprene washer. Fastener head shall match wall panel finish. Fabricate to eliminate condensation on interior side of panel. Joints between panels form weathertight seals.
 
** NOTE TO SPECIFIER ** Delete curved wall panels if not required.
 
1.
Curved wall panels: Panels shall be factory curved as approved by manufacturer.
 
** NOTE TO SPECIFIER ** Delete trim accessories if trim is specified in a different section.
 
2.
Trim Accessories: Fabricate complying with recommendations in SMACNA's "Architectural Sheet Metal Manual".
 
** NOTE TO SPECIFIER ** Delete factory fabricated mitered corners if trim covered corners are chosen.
 
3.
Mitered Corners: Structurally bonded horizontal outside or inside trimless corners matching metal wall panel material, profile and factory applied finish. Fabricated by wall panel manufacturer.
a.
Basis of Design: Morin Miterseam Corners 24 x 24 in (610 x 610 mm).
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color indicated.
d.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
e.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
f.
a.)Primer: 0.2 mil (0.0051 mm).
g.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
h.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
i.
a.)Primer: 0.2 mil (0.0051 mm).
j.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
k.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
l.
a.)Primer: 0.2 mil (0.0051 mm).
m.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
n.
c.)Clear Coat: 0.5 mil (0.0127 mm).
o.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
p.
a.)Primer: 0.8 mil (0.0203 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
r.
c.)Clear Coat: 0.8 mil (0.0203 mm).
2.
Exposed Aluminum-Zinc Alloy-Coating; ASTM A792, Class AZ50 coating. "Galvalume" or "Zincalume"protective coating.
3.
Stainless Steel: Dull, cold rolled, IID.
4.
Stainless Steel: Bright, cold rolled, IIB.
5.
Stainless Steel: Polished directional satin, 4.
6.
Copper: Natural.
7.
Copper: Acid patina.
8.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Perforated panels are optional. Delete if not required.
 
F.
Perforated Panels:
1.
Fabrication: Aluminum construction.
2.
Fabrication: Stainless steel construction.
3.
Perforation Pattern: ______.
4.
Perforation Pattern: As selected by the Architect.
a.
Open Area: 10 to 40 percent; dependent on hole sizing and spacing.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.6
STRUCTURAL STANDING SEAM HORIZONTAL OR VERTICAL METAL WALL PANELS (MorZip Series)
A.
Performance Requirements:
1.
Structural Performance: Testing shall be done based on ASTM E330 or E1592:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits options not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/180 of the span.
e.
Horizontal Deflection Limits: No greater than L/240 of the span.
2.
Air Infiltration Tested per ASTM E283: 0.043 cu ft per min per sq ft (0.013 cu m per min per sq m) of fixed wall area. Static air-pressure differential of 30.0 ft-lbs per sq ft (437.8 Nm per sq m).
3.
Water Penetration under Static Pressure Tested per ASTM E331: 30.0 lbs per sq ft (146.5 kg per sq m).
4.
Finish Characteristics:
a.
Gloss per ASTM D523: 15 plus or minus.
b.
Pencil Hardness per ASTM D3363: HB - H.
c.
Flexibility, T-Bend per ASTM D4145: 1-2T bend.
d.
Flexibility, Mandrel per ASTM D522: No cracking.
e.
Adhesion per ASTM D3359: No adhesion loss.
f.
Reverse Impact per ASTM D2794: No cracking or adhesion loss.
g.
Abrasion Resistance per ASTM D968: 65 plus or minus 10 liters.
h.
Graffiti Resistance: Minimal effect.
i.
Acid Pollutant Resistance per ASTM D1308: No effect.
j.
Salt Fog Resistance per ASTM B117: Passes 1000 hours.
k.
Cyclic Salt Fog and UV Exposure per ASTM D5894: Passes 2016 hours.
l.
Humidity Resistance per ASTM D2247 and D714: Passes 1500 hours.
m.
Color Retention per ASTM G153 and G154: Passes 5000 hours.
n.
Chalk Resistance per ASTM D4214, Method A: Maximum chalk is a rating of 8.
o.
Color Tolerances per ASTM D2244: Greater than 5DELTA_SYMBOLE units on panels.
B.
Basis of Design: MorZip Wall Series. Structural standing seam horizontal or vertical metal wall panels.
1.
Wall Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 16 in (406 mm).
c.
Panel Width: 18 in (457 mm).
d.
Profile: MorZip profile.
e.
Seam Height: 2-1/2 in (63 mm).
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
f.
Texture: Smooth.
g.
Texture: Embossed.
 
** NOTE TO SPECIFIER ** Delete perforated pattern option if not required.
 
h.
Perforated Pattern; Percent Open: ______.
 
** NOTE TO SPECIFIER ** Delete curving option if not required.
 
i.
Curving: Striated curving.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
j.
Steel: Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
k.
1.)Gauge: 22; 0.0336 in (0.85 mm).
l.
2.)Gauge: 20; 0.0396 in (1.01 mm).
m.
Zinc-Coated (Galvanized) Steel Sheet: ASTM A653, G90 coating designation.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
n.
1.)Gauge: 24; 0.0239 in (0.61 mm).
o.
2.)Gauge: 22; 0.0299 in (0.76 mm).
p.
3.)Gauge: 20; 0.0359 in (0.91 mm).
q.
Aluminum Coil stock meeting ASTM B209; 3003-H34 as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness option not required.
 
r.
1.)Thickness: 0.040 inch (1.02 mm).
s.
2.)Thickness: 0.050 inch (1.27 mm).
t.
Stainless Steel: ASTM A240 or ASTM A666, Type 316, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
u.
1.)Gauge: 20; 0.0375 in (0.95 mm).
v.
2.)Gauge: 22; 0.0312 in (0.79 mm).
w.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
x.
1.)Gauge: 20; 0.0375 in (0.95 mm).
y.
2.)Gauge: 22; 0.0312 in (0.79 mm).
z.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
aa.
1.)Weight: 20 oz per sq ft (6.1 kg per sq m).
ab.
Zinc: Sheet stock meeting ASTM B69, Type I and Type II, consisting of zinc with copper and titanium additives.
ac.
1.)Gauge: 0.039 in (1.00 mm).
 
** NOTE TO SPECIFIER ** Delete liner panel if not required.
 
2.
Liner Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width option not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 24 in (610 mm).
 
** NOTE TO SPECIFIER ** See manufacturer's detailed information for liner panel series available. Delete liner panel series option not required.
 
c.
Liner Panel Series: ______.
d.
Liner Panel Series: As indicated on Drawings.
C.
Accessories: As required for a complete installation and indicated on approved shop drawings and per manufacturer's approved details.
a.
Fasteners: Fasteners as recommended by manufacturer.
b.
Concealed Anchor Clips: Floating anchor clip, two piece.
1.
Closure Strips; Closed Cell: Minimum 1 in (25 mm) thick matching wall panel profile.
 
** NOTE TO SPECIFIER ** Delete flashing and trim paragraph not required.
 
2.
Flashing and Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
3.
Flashing and Trim: Same material, thickness, and finish as wall panels.
4.
Trim Locations: Include, but not limited to: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
5.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot dip galvanizing option not required.
 
a.
Hot-dip galvanized per ASTM A653, G40.
b.
Hot-dip galvanized per ASTM A653, G60.
c.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
d.
1.)Nominal Thickness: 0.025 in (0.063 mm)
e.
2.)Nominal Thickness: 0.040 in (1.02 mm)
f.
3.)Nominal Thickness (in/mm): ______.
g.
4.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
h.
5.)Depth: 7/8 in (22 mm).
i.
6.)Depth: 1-1/2 in (38 mm).
j.
7.)Depth (in/mm): ______.
k.
8.)Depth: As indicated on Drawings.
l.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
m.
1.)Nominal Thickness: 0.064 in (1.63 mm).
n.
2.)Nominal Thickness (in/mm): ______.
o.
3.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
p.
4.)Depth: 3/4 in (19 mm).
q.
5.)Depth (in/mm): ______.
r.
6.)Depth: As indicated on Drawings.
s.
Furring Brackets: Adjustable, corrugated-edge type of steel sheet with 0.040 in (1.02 mm) nominal thickness.
t.
Tie Wire: ASTM A641, Class 1 zinc coating, soft temper, 0.062 in (1.57 mm) diameter wire, or double strand of 0.048 in (1.22 mm) diameter wire.
6.
Panel Sealant:
a.
Joint Sealant: ASTM C920 as recommended by panel manufacturer.
b.
Butyl-Rubber-Based, Solvent-Release Sealant per ASTM C1311.
D.
Fabrication: Panels factory formed to lap and interconnect with edges of adjacent panels. Mechanically attached to supports using concealed fasteners. Fabricate to eliminate condensation on interior side of panel. Joints between panels form weathertight seals.
 
** NOTE TO SPECIFIER ** Delete trim accessories option not required or delete both if trim is specified in a different section.
 
1.
Trim Accessories: Fabricate complying with recommendations in SMACNA's "Architectural Sheet Metal Manual".
2.
Trim Accessories: Provide manufacturer's standard extruded aluminum trim.
 
** NOTE TO SPECIFICATION ** Delete soffit panels option not required or delete both options if soffits are not required.
 
3.
Soffit panels shall be perforated.
4.
Soffit panels shall be non-perforated.
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color indicated.
 
** NOTE TO SPECIFIER ** Delete concealed surface options not required.
 
d.
Finish and Color; Concealed Surface: Manufacturer's standard primer.
e.
Finish and Color; Concealed Surface: Selected from manufacturer's selection.
f.
Finish and Color; Concealed Surface: Custom color as selected by Architect.
g.
Finish and Color; Concealed Surface: Color indicated.
h.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
i.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
j.
a.)Primer: 0.2 mil (0.0051 mm).
k.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
l.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
m.
a.)Primer: 0.2 mil (0.0051 mm).
n.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
o.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
p.
a.)Primer: 0.2 mil (0.0051 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
r.
c.)Clear Coat: 0.5 mil (0.0127 mm).
s.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
t.
a.)Primer: 0.8 mil (0.0203 mm).
u.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
v.
c.)Clear Coat: 0.8 mil (0.0203 mm).
2.
Aluminum: Mill finish.
3.
Stainless Steel: Bright, cold rolled, IIB.
4.
Stainless Steel: Polished directional satin, 4.
5.
Copper: Natural.
6.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Perforated panels are optional. Delete if not required.
 
F.
Perforated Panels:
1.
Fabrication: Aluminum construction.
2.
Fabrication: Stainless steel construction.
3.
Perforation Pattern: ______.
4.
Perforation Pattern: As selected by the Architect.
a.
Open Area: 10 to 40 percent; dependent on hole sizing and spacing.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.7
CONCEALED FASTENER SINGLE-SKIN PERFORATED METAL WALL PANELS (Concealed Fastener Series)
A.
Performance Criteria:
1.
Structural Performance: Testing shall be done based on ASTM E1592:
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Wind Loads; Uniform Pressure: ______.
b.
Wind Loads; Uniform Pressure: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete horizontal deflection limits option not required.
 
c.
Horizontal Deflection Limits: ______ of the span.
d.
Horizontal Deflection Limits: No greater than L/90 of the span.
B.
Basis of Design: Concealed Fastener Single Skin Perforated Metal Wall Panels as manufactured by Morin, a Kingspan Group Company.
1.
Wall Panel Description:
a.
Panel Thickness: 1-1/2 in (38 mm) thick.
b.
Panel Joint: Tongue and groove interlock joint.
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
c.
Panel Width: 12 in (305 mm).
d.
Panel Width: 16 in (406 mm).
e.
Panel Width: 18 in (457 mm).
f.
Panel Width: 22 in (559 mm).
g.
Panel Width: 24 in (610 mm).
 
** NOTE TO SPECIFIER ** Delete profile option not required. See detailed manufacturer information for profile designations; https://www.kingspan.com/us/en-us/product-groups/metal-roof-wall-systems/wall-systems/concealed-fasteners
 
h.
Profile: ______.
 
** NOTE TO SPECIFIER ** Delete perforation pattern options not required.
 
i.
Perforation Pattern: 1/8 in (3 mm) holes.
 
** NOTE TO SPECIFIER ** Delete open area options not required.
 
j.
1.)Open Area: 40 percent; 3/16 in (4.8 mm) hole spacing.
k.
2.)Open Area: 30 percent; 7/32 in (5.5 mm mm) hole spacing.
l.
3.)Open Area: 23 percent; 1/4 in (6.3 mm) hole spacing.
m.
4.)Open Area: 10 percent; 3/8 in (9.5 mm) hole spacing.
n.
Perforation Pattern: 3/16 in (4.8 mm) holes.
o.
1.)Open Area: 33 percent open area; 5/16 in (7.9 mm) hole spacing.
p.
Perforation Pattern: 1/4 in (6.3 mm) holes.
q.
1.)Open area: 23 percent open area; 1/2 in (12.7 mm) hole spacing.
r.
Perforation Pattern: 3/8 in (9.5 mm) holes.
s.
1.)Open Area: 40 percent; 9/16 in (14.3 mm) hole spacing.
 
** NOTE TO SPECIFIER ** Delete material options not required.
 
t.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness option not required.
 
u.
1.)Thickness: 0.040 in (1.02 mm)
v.
2.)Thickness: 0.050 in (1.27 mm).
w.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
x.
1.)Gauge: 20; 0.0375 in (0.95 mm).
y.
2.)Gauge: 22; 0.0312 in (0.79 mm).
z.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
aa.
1.)Weight: 20 oz per sq ft (6.1 kg per sq m).
ab.
Zinc: Sheet stock meeting ASTM B69, Type I and Type II, consisting of zinc with copper and titanium additives.
ac.
1.)Gauge: 0.039 in (1.00 mm).
C.
Accessories: As required for a complete installation and indicated on approved shop drawings, per manufacturer's approved details. Match material and finish of wall panels.
1.
Closure Strips; Metal Profile: Same gauge, material and finish as panel.
2.
Swedged ends: Factory crimped end laps.
 
** NOTE TO SPECIFIER ** Delete trim option not required.
 
2.
Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
3.
Trim: Same material, thickness and finish as wall panels.
4.
Trim Locations: Include, but not limited to: Drips, sills, jambs, corners, framed openings, parapet caps, and fillers.
5.
Metal Framing: ASTM C645, cold-formed metallic-coated steel sheet.
 
** NOTE TO SPECIFIER ** Delete hot-dip galvanized option not required.
 
6.
1.)Hot-Dip Galvanized: ASTM A653, G40.
7.
2.)Hot-Dip Galvanized: ASTM A653, G60.
a.
Hat-Shaped, Rigid Furring Channels:
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
b.
1.)Nominal Thickness: 0.025 in (0.063 mm)
c.
2.)Nominal Thickness: 0.040 in (1.02 mm)
d.
3.)Nominal Thickness (in/mm): ______.
e.
4.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
f.
5.)Depth: 7/8 in (22 mm).
g.
6.)Depth: 1-1/2 in (38 mm).
h.
7.)Depth (in/mm): ______.
i.
8.)Depth: As indicated on Drawings.
j.
Cold-Rolled Furring Channels: Minimum 1/2 in (13 mm) wide flange.
 
** NOTE TO SPECIFIER ** Delete nominal thickness options not required
 
k.
1.)Nominal Thickness: 0.064 in (1.63 mm).
l.
2.)Nominal Thickness (in/mm): ______.
m.
3.)Nominal Thickness: As indicated on Drawings.
 
** NOTE TO SPECIFIER ** Delete depth options not required
 
n.
4.)Depth: 3/4 in (19 mm).
o.
5.)Depth (in/mm): ______.
p.
6.)Depth: As indicated on Drawings.
q.
Furring Brackets: Adjustable, corrugated-edge type of steel sheet with 0.040 in (1.02 mm) nominal thickness.
r.
Tie Wire: ASTM A641, Class 1 zinc coating, soft temper, 0.062 in (1.57 mm) diameter wire, or double strand of 0.048 in (1.22 mm) diameter wire.
D.
Fabrication: Panels factory formed to lap and interconnect with edges of adjacent panels. Mechanically attached to supports using concealed fasteners.
 
** NOTE TO SPECIFIER ** Delete trim accessories option not required or delete both if trim is specified in a different section.
 
1.
Trim Accessories: Fabricate complying with recommendations in SMACNA's "Architectural Sheet Metal Manual".
2.
Trim Accessories: Provide manufacturer's standard extruded aluminum trim.
 
** NOTE TO SPECIFIER ** Delete if soffit panels if not required.
 
3.
Soffit panels shall be perforated.
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material and finish paragraphs not required.
 
1.
Aluminum: Panels shall be finished on exterior and interior surfaces.
 
** NOTE TO SPECIFIER ** Aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color indicated.
d.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish system options below not required.
 
e.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
f.
a.)Primer: 0.2 mil (0.0051 mm).
g.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
h.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
i.
a.)Primer: 0.2 mil (0.0051 mm).
j.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
k.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat.
l.
a.)Primer: 0.2 mil (0.0051 mm).
m.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
n.
c.)Clear Coat: 0.5 mil (0.0127 mm).
o.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
p.
a.)Primer: 0.8 mil (0.0203 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
r.
c.)Clear Coat: 0.8 mil (0.0203 mm).
2.
Stainless Steel: Dull, cold rolled, IID
3.
Stainless Steel: Bright, cold rolled, IIB
4.
Stainless Steel: Polished directional satin, 4.
5.
Copper: Natural.
6.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.8
STRUCTURAL STANDING SEAM METAL WALL PANELS (SymmeTry Series)
A.
Performance Requirements:
1.
Wall assembly shall be tested for structural performance under uniform static air pressure differences in accordance with ASTM E1592.
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Uniform Pressure: Insert design pressure; acting inward or outward.
b.
Uniform Pressure: As indicated on drawings; acting inward or outward.
 
** NOTE TO SPECIFIER ** Delete if project is not in Florida.
 
2.
Wall assembly shall be approved by the Florida Building Code (FBC) for impact resistance and uplift in accordance with Product Approval.
 
** NOTE TO SPECIFIER ** Insert snow load requirements. Delete if not required.
 
a.
Snow Loads (lbs per sq ft / kg per sq m): ______.
 
** NOTE TO SPECIFIER ** Delete if not required.
 
b.
Deflection: Panel shall be limited to L/180.
c.
Deflection: Panel shall be limited to L/240.
3.
Metal wall panels shall be capable of withstanding a 250 lbs (113.4 kg) concentrated load applied to a 4 sq in (2581 sq mm) area in the middle of the panel. No noticeable buckling or permanent distortion of the panel shall occur.
4.
Water Penetration under Static Pressure: Provide metal wall panel systems designed to resist penetration of water under static pressure.
a.
Testing shall be based on ASTM E1646. Wall panels water leakage at 40.0 lbs per sq ft (195.3 kg per sq m).
5.
Air Infiltration: Provide metal wall panel assemblies designed to resist air infiltration.
a.
Testing shall be done based on ASTM E1680. Wall panels when tested shall have a maximum air leakage of 0.006 cu ft per min per sq ft (0.002 cu m per min per sq m) of fixed wall area at a minimum static air-pressure differential of 40.0 ft-lbs per sq ft (583.76 Nm per sq m).
6.
Wind Uplift Resistance:
a.
Wall assembly shall comply with UL 580 for wind uplift resistance. Class UL 90.
b.
FM Global Approvals; per FM Approval Standard 4471.
c.
1.)Metal Wall Panel Attachment: Meet requirements of FM Class 1A-120.
 
** NOTE TO SPECIFIER ** Delete Hailstorm Rating when project is not located in a geographic area subject to hailstorms.
 
d.
2.)Hailstorm Rating: SH.
7.
Fire Performance of Wall Assembly: Meet requirements of ASTM E108, Class A.
B.
Basis of Design: SymmeTry Wall Series. Structural Standing Seam Natural Metal Wall Panels
1.
Wall Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 16 in (406 mm).
c.
Panel Width: 18 in (457 mm).
d.
Profile: SymmeTry.
 
** NOTE TO SPECIFIER ** delete seam height options not required.
 
e.
Seam Height: 1-1/2 in (38 mm).
f.
Seam Height: 2 in (52 mm).
g.
Seam Height: 2-1/2 in (63 mm).
h.
Seam Height: 3 in (76 mm).
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
i.
Texture: Smooth.
j.
Texture: Embossed.
2.
Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
3.
Zinc-Coated (Galvanized) Steel Sheet: ASTM A653, G90 coating designation
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
4.
Aluminum Coil stock meeting ASTM B209; 3003-H14 as required for forming operations.
 
** NOTE TO SPECIFIER ** Delete thickness option not required.
 
a.
Thickness: 0.040 inch (1.02 mm).
b.
Thickness: 0.050 inch (1.25 mm).
5.
Stainless Steel: ASTM A240 or ASTM A666, Type 316, dead soft, fully annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
a.
Gauge: 20; 0.0375 in (0.95 mm).
b.
Gauge: 22; 0.0312 in (0.79 mm).
6.
Stainless Steel: ASTM A240 or ASTM A666, Type 304, dead soft, fully annealed.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
a.
Gauge: 20; 0.0375 in (0.95 mm).
b.
Gauge: 22; 0.0312 in (0.79 mm).
7.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
a.
Thickness: 20 oz. per sq ft (6.103 kg per sq m).
8.
Zinc: Sheet stock meeting ASTM B69, Type I and Type II, consisting of zinc with copper and titanium additives.
 
** NOTE TO SPECIFIER ** Delete gauge option not required.
 
a.
Gauge: 0.0315 in (0.8 mm).
b.
Gauge: 0.0394 in (1.0 mm).
C.
Accessories:
1.
Wall panel accessories: Provide accessories as required for a complete installation. Accessories shall be as indicated on approved shop drawings and per manufacturer's approved standard details. Match material and finish of metal wall panels.
a.
Fasteners: Fasteners as recommended by manufacturer.
2.
Concealed Anchor Clips: Floating anchor clip, two piece, or single halter style clip.
3.
Closure Strips; Closed Cell: Minimum 1 in (25 mm) thick matching wall panel profile.
 
** NOTE TO SPECIFIER ** Delete flashing and trim paragraph not required.
 
4.
Flashing and Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
5.
Flashing and Trim: Fabricate flashing and trim from same material as wall panels unless otherwise noted. Finish to match metal wall panels.
a.
Locations include, but are not limited to the following: Drips, eave and rake edges, wall penetrations, hips, and valleys.
6.
Panel Joint Sealant: Per ASTM C920 as recommended by panel manufacturer.
7.
Butyl Tape: Per panel manufacturer's recommendations for panel to panel and panel to trim seal.
8.
Butyl Sealants: Non-skinning type per panel manufacturer's recommendations.
D.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color as indicated on the Drawings.
 
** NOTE TO SPECIFIER ** Delete concealed surface options not required.
 
d.
Finish and Color; Concealed Surface: Manufacturer's standard primer.
e.
Finish and Color; Concealed Surface: Selected from manufacturer's selection.
f.
Finish and Color; Concealed Surface: Custom color as selected by Architect.
g.
Finish and Color; Concealed Surface: Color as indicated on the Drawings.
h.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) Metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish options below not required.
 
i.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
j.
a.)Primer: 0.2 mil (0.0051 mm).
k.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
l.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
m.
a.)Primer: 0.2 mil (0.0051 mm).
n.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
o.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat
p.
a.)Primer: 0.2 mil (0.0051 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (00.0203 mm).
r.
c.)Clear Coat: 0.5 mil (0.0127 mm).
s.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
t.
a.)Primer: 0.8 mil (0.0203 mm).
u.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
v.
c.)Clear Coat: 0.8 mil (0.0203 mm).
2.
Exposed Aluminum-Zinc Alloy-Coating; ASTM A792, Class AZ50 coating. "Galvalume" or "Zincalume" protective coating.
3.
Aluminum: Mill finish.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.9
SINGLE/DOUBLE LOCK OR SNAPLOCK STANDING SEAM, SINGLE ELEMENT METAL WALL PANELS (SLR AND SWL SERIES)
A.
Performance Requirements:
1.
Wall assembly shall be tested for structural performance under uniform static air pressure differences in accordance with ASTM E1592.
 
** NOTE TO SPECIFIER ** Delete uniform pressure option not required.
 
a.
Uniform Pressure: Insert design pressure; acting inward or outward.
b.
Uniform Pressure: As indicated on drawings; acting inward or outward.
 
** NOTE TO SPECIFIER ** Delete if project is not in Florida.
 
2.
Wall assembly shall be approved by the Florida Building Code (FBC) for impact resistance and uplift in accordance with Product Approval.
 
** NOTE TO SPECIFIER ** Insert snow load requirements. Delete if not required.
 
a.
Snow Loads (lbs per sq ft / kg per sq m): ______.
 
** NOTE TO SPECIFIER ** Delete if not required.
 
b.
Deflection: Panel shall be limited to L/180.
c.
Deflection: Panel shall be limited to L/240.
3.
Metal wall panels shall be capable of withstanding a 250 lbs (113.4 kg) concentrated load applied to a 4 sq in (2581 sq mm) area in the middle of the panel. No noticeable buckling or permanent distortion of the panel shall occur.
4.
Water Penetration under Static Pressure: Provide metal wall panel systems designed to resist penetration of water under static pressure.
a.
Testing shall be based on ASTM E331. Wall panels water leakage at 40.0 lbs per sq ft (195.3 kg per sq m).
5.
Air Infiltration: Provide metal wall panel assemblies designed to resist air infiltration.
a.
Testing shall be done based on ASTM E283 and E1680. Wall panels when tested shall have a maximum air leakage of 0.153 cu ft per min per sq ft (0.047 cu m per min per sq m) of fixed wall area at a minimum static air-pressure differential of 40.0 lbs per sq ft (195.3 kg per sq m).
6.
Wind Uplift Resistance:
a.
Wall assembly shall comply with UL 580 for wind uplift resistance.
 
** NOTE TO SPECIFIER ** Delete Class options not required.
 
b.
1.)Class UL 30.
c.
2.)Class UL 60.
d.
3.)Class UL 90.
e.
FM Global Approvals; per FM Approval Standard 4471.
f.
1.)Metal Wall Panel Attachment: Meet requirements of FM Class 1A-120.
 
** NOTE TO SPECIFIER ** Delete Hailstorm Rating when project is not located in a geographic area subject to hailstorms.
 
g.
2.)Hailstorm Rating: SH.
7.
Finish Characteristics:
 
** NOTE TO SPECIFIER ** Delete finish characteristics not required.
 
a.
Gloss per ASTM D523: 15 plus or minus.
b.
Pencil Hardness per ASTM D3363: HB - H.
c.
Flexibility, T-Bend per ASTM D4145: 1-2T bend.
d.
Flexibility, Mandrel per ASTM D522: No cracking.
e.
Adhesion per ASTM D3359: No adhesion loss.
f.
Reverse Impact per ASTM D2794: No cracking or adhesion loss.
g.
Abrasion Resistance per ASTM D968: 65 plus or minus 10 liters.
h.
Graffiti Resistance: Minimal effect.
i.
Acid Pollutant Resistance per ASTM D1308: No effect.
j.
Salt Fog Resistance per ASTM B117: Passes 1000 hours.
k.
Cyclic Salt Fog and UV Exposure per ASTM D5894: Passes 2016 hours.
l.
Humidity Resistance per ASTM D2247 and D714: Passes 1500 hours.
m.
Color Retention per ASTM G153 and G154: Passes 5000 hours.
n.
Chalk Resistance per ASTM D4214, Method A: Maximum chalk is a rating of 8.
o.
Color Tolerances per ASTM D2244: Greater than 5DELTA_SYMBOLE units on panels.
 
** NOTE TO SPECIFIER ** Delete the basis of design option not required.
 
B.
Basis of Design: SLR "Single or Double Lock Standing Seam Wall Panels".
1.
Wall Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 16 in (406 mm).
c.
Panel Width: 18 in (457 mm).
d.
Profile: SR.
e.
Seam Height: 2 in (51 mm).
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
f.
Texture: Smooth.
g.
Texture: Embossed.
 
** NOTE TO SPECIFIER ** delete material options not required.
 
2.
Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
c.
Gauge: 20; 0.0359 in (0.91 mm).
3.
Zinc-Coated (Galvanized) Steel Sheet: ASTM A653, G90 coating designation.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
c.
Gauge: 20; 0.0359 in (0.91 mm).
4.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
a.
Thickness: 0.032 in (0.81 mm).
b.
Thickness: 0.040 in (1.02 mm).
5.
Stainless Steel: ASTM A240 or ASTM A666, Type 316, dead soft, fully annealed.
a.
Gauge: 24; 0.025 in (0.64 mm).
6.
Stainless Steel: ASTM A240 or ASTM A666, [Type 304, dead soft, fully annealed.
a.
Gauge: 24; 0.025 in (0.64 mm).
7.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
a.
Thickness: 0.0276 in (0.7 mm).
b.
Thickness: 0.0315 in (0.8 mm).
C.
Basis of Design: SWL SNAPLOCK " Non Mechanically Seamed Wall Panels".
1.
Wall Panel Description:
 
** NOTE TO SPECIFIER ** Delete panel width options not required.
 
a.
Panel Width: 12 in (305 mm).
b.
Panel Width: 16 in (406 mm).
c.
Panel Width: 18 in (457 mm).
d.
Profile: SLR.
e.
Seam Height: 1-3/4 in (38 mm).
 
** NOTE TO SPECIFIER ** Delete texture option not required.
 
f.
Texture: Smooth.
g.
Texture: Embossed.
 
** NOTE TO SPECIFIER ** delete material options not required.
 
2.
Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A792, Class AZ50 coating designation, Grade 40.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
c.
Gauge: 20; 0.0359 in (0.91 mm).
3.
Zinc-Coated (Galvanized) Steel Sheet: ASTM A653, G90 coating designation.
 
** NOTE TO SPECIFIER ** Delete gauge options not required.
 
a.
Gauge: 24; 0.0239 in (0.61 mm).
b.
Gauge: 22; 0.0299 in (0.76 mm).
c.
Gauge: 20; 0.0359 in (0.91 mm).
4.
Aluminum: Coil Stock meeting ASTM B209; Alloy and temper as required for forming operations.
a.
Thickness: 0.032 in (0.81 mm).
b.
Thickness: 0.040 in (1.02 mm).
5.
Stainless Steel: ASTM A240 or ASTM A666, Type 316, dead soft, fully annealed.
a.
Gauge: 24; 0.025 in (0.64 mm).
6.
Stainless Steel: ASTM A240 or ASTM A666, [Type 304, dead soft, fully annealed.
a.
Gauge: 24; 0.025 in (0.64 mm).
7.
Copper: Sheet stock meeting ASTM B370, cold-rolled, H00 or H01 temper.
a.
Thickness: 0.0276 in (0.7 mm).
b.
Thickness: 0.0315 in (0.8 mm).
D.
Accessories:
1.
Wall panel accessories: Provide accessories as required for a complete installation. Accessories shall be as indicated on approved shop drawings and per manufacturer's approved standard details. Match material and finish of metal wall panels.
a.
Fasteners: Fasteners as recommended by manufacturer.
 
** NOTE TO SPECIFIER ** Delete concealed anchor clips not required or keep both.
 
2.
Concealed Anchor Clips: Floating anchor clip, two piece.
3.
Concealed Anchor Clips: One piece fixed clip.
4.
Backing Plates: Provide metal backing plates at panel end splices fabricated from material recommended by manufacturer.
5.
Closure Strips: Provide closed cell closure strips, minimum 1 in (25 mm) thick matching metal wall panel profile.
 
** NOTE TO SPECIFIER ** Delete flashing and trim paragraph not required.
 
6.
Flashing and Trim: Provided under Section 07 62 00 - Sheet Metal Flashing and Trim.
7.
Flashing and Trim: Fabricate flashing and trim from same material as wall panels unless otherwise noted. Finish to match metal wall panels.
8.
Trim Locations: Include, but are not limited to the following: Drips, eave and rake edges, wall penetrations, hips, and valleys.
9.
Panel Joint Sealant: Per ASTM C920 as recommended by panel manufacturer.
10.
Butyl Tape: Per panel manufacturer's recommendations for panel to panel and panel to trim seal.
11.
Butyl Sealants: Non-skinning type per panel manufacturer's recommendations.
E.
Finishes:
 
** NOTE TO SPECIFIER ** Delete the material finish options not required.
 
1.
Aluminum and Steel:
 
** NOTE TO SPECIFIER ** Steel and aluminum panels come in a painted finish or aggregate finish. Select finish to meet project requirements. Delete exposed surface color options not required.
 
a.
Finish and Color; Exposed Surface: Selected from manufacturer's selection.
b.
Finish and Color; Exposed Surface: Custom color as selected by Architect.
c.
Finish and Color; Exposed Surface: Color as indicated on the Drawings.
 
** NOTE TO SPECIFIER ** Delete concealed surface options not required.
 
d.
Finish and Color; Concealed Surface: Manufacturer's standard primer.
e.
Finish and Color; Concealed Surface: Selected from manufacturer's selection.
f.
Finish and Color; Concealed Surface: Custom color as selected by Architect.
g.
Finish and Color; Concealed Surface: Color as indicated on the Drawings.
h.
Finish System:
 
** NOTE TO SPECIFIER ** The 1.0 mil (0.025 mm) two coat system (Solid color) is most commonly used. The 1.0 mil (0.025 mm) Mica color coat and the 1.5 mil (0.038 mm) Metallic color coat systems are chosen if premium colors are desired. Use the 2.4 mil (0.061 mm) three coat system if a harsh environment is anticipated (such as industrial facilities or in coastal regions). The paint fluoropolymer (PVDF) systems will receive the 20 year finish warranty. Delete finish options below not required.
 
i.
1.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Solid color coat.
j.
a.)Primer: 0.2 mil (0.0051 mm).
k.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
l.
2.)Two Coat Fluoropolymer (PVDF): 1.0 mil (0.025 mm) Mica color coat.
m.
a.)Primer: 0.2 mil (0.0051 mm).
n.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
o.
3.)Three Coat Fluoropolymer (PVDF): 1.5 mil (0.038 mm) Metallic color coat
p.
a.)Primer: 0.2 mil (0.0051 mm).
q.
b.)Kynar 500 (70 percent): 0.8 mil (00.0203 mm).
r.
c.)Clear Coat: 0.5 mil (0.0127 mm).
s.
4.)Three Coat Fluoropolymer (PVDF): 2.4 mil (0.061 mm). Solid color coat.
t.
a.)Primer: 0.8 mil (0.0203 mm).
u.
b.)Kynar 500 (70 percent): 0.8 mil (0.0203 mm).
v.
c.)Clear Coat: 0.8 mil (0.0203 mm).
2.
Exposed Aluminum-Zinc Alloy-Coating; ASTM A792, Class AZ50 coating. "Galvalume" or "Zincalume" protective coating.
3.
Aluminum: Mill finish.
4.
Stainless Steel: Dull, cold rolled, IID.
5.
Stainless Steel: Bright, cold rolled, IIB.
6.
Stainless Steel: Polished directional satin, IV.
7.
Copper: Natural.
8.
Zinc: As selected by Architect from manufacturer's standard selections.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.10
INSULATION
A.
Refer to Section 07 21 26 - Blown Insulation.
1.
Board Insulation: ASTM C612, Type IA, unfaced semi rigid insulation. Nominal density of 3 pounds per cubic foot. Size as required for liner panels.
2.11
FABRICATI0N
 
** NOTE TO SPECIFIER ** Delete paragraphs not required for the project.
 
A.
Metal wall panels; formed to lap with edges of adjacent panels then mechanically attached to wall deck using fasteners and concealed anchor clips. Anchor clips are then machine seamed into standing seam.
B.
Fabricate metal wall panels with joints between panels designed to form weathertight seals.
C.
Curved wall panels: Panels shall be factory or field curved as approved by manufacturer.
D.
Flashing and Trim Accessories: Fabricate steel trim accessories to comply with recommendations outlined in SMACNA's "Architectural Sheet Metal Manual".
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
2.12
INSULATION
A.
Refer to Section 07 21 26 - Blown Insulation.
B.
Board Insulation: ASTM C612, Type IA, unfaced semi rigid insulation. Nominal density of 3 pounds per cubic foot. Size as required for liner panels.
PART 3 EXECUTION
 
3.1
EXAMINATION
A.
Provide field measurements to manufacturer to achieve proper fit wall panel envelope. Provide measurements in timely manner so as not to impact construction schedule.
B.
Structural supports for panel installation by others. Install within the following tolerances:
1.
Plus or minus 1/8 inch in 5 ft (3 mm in 1524 mm); any direction along framing plane.
2.
Plus or minus 1/4 inch (6 mm) cumulative in 20 ft (6096 mm); any direction along framing plane..
3.
Plus or minus 1/2 inch (13 mm) from framing plane on any elevation.
4.
Plumb or level within 1/8 inch (3 mm) at changes of transverse for pre-formed corner panel applications.
5.
Verify horizontal bearing support is provided behind vertical panel systems and vertical bearing support is provided behind horizontal panel systems. Support width as recommended by manufacturer.
C.
Examine individual panels upon removing from the bundle; notify manufacturer of panel defects. Do not install defective panels.
3.2
PANEL INSTALLATION
 
** NOTE TO SPECIFIER ** Delete paragraphs that are not required for the project.
 
A.
Apply sealant to joints per manufacturer's recommendations and approved shop drawings.
B.
Install panels level and true-to-line to dimensions and layout indicated on shop drawings.
1.
Panels in one piece lengths from eave to base unless otherwise indicated.
2.
Use recommended clips, screws, fasteners and sealants as indicated.
3.
Install per manufacturer's guidelines and recommendations; weathertight, without distortion, buckles, or waves.
C.
Panel Seaming: Use an electric seaming machine as recommended by manufacturer.
D.
Provide weatherproof wall fittings for pipe and conduit penetrating walls.
E.
Cutting and fitting of panels shall be neat, square and true. Torch cutting is prohibited.
F.
Dissimilar materials: Treat contact areas as recommended by wall panel manufacturer.
3.3
FLASHING AND TRIM INSTALLATION
A.
Place trim and trim fasteners only as indicated per details on approved shop drawings.
B.
Apply sealant tape at trim, per manufacturer's shop drawings, for weathertight installation.
 
** NOTE TO SPECIFIER ** Delete article if not required.
 
3.4
SEALANT INSTALLATION FOR EXPOSED JOINTS
A.
Clean and prime surfaces to receive exterior exposed sealants per sealant manufacturer's recommendations.
B.
Follow sealant manufacturer's recommendations for joint width-to-depth ratio, application temperature range, size and type of backer rod, and compatibility of materials for adhesion.
1.
Direct contact between butyl and silicone sealants shall not be permitted.
3.5
CLEANING AND PROTECTION
A.
Remove protective film immediately after installation.
B.
Touch-up, repair or replace damaged metal panels and trim.
C.
After panel installation, clear weep holes and drainage channels of obstructions, dirt, and sealant.
END OF SECTION