MasterFormat: 2014
SpecWizard: customize this spec    Download this Folding Glazed Wall Systems - Exterior and Interior Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
Nana Wall Systems, Inc. Folding Glazed Wall Systems - Exterior and Interior
 
         
SECTION 08 41 00
 
         
FOLDING GLAZED WALL SYSTEMS - EXTERIOR AND INTERIOR
 
         
 
         
Copyright 2010 - 2019 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** Nana Wall Systems, Inc.; Opening glass walls, folding glass wall systems, sliding glass wall systems.
This section is based on the products of Nana Wall Systems, Inc., which is located at:
100 Meadowcreek Dr. Suite 250
Corte Madera, CA 94925
Toll Free Tel: 800-873-5673
Tel: 415-383-3148
Fax: 415-383-0312
Email: request info
Web: https://www.nanawall.com

[ Click Here ] for additional information.

Nana Wall redefined the category of opening glass wall systems. During our 30 years in business, we have earned the trust of architects, builders, design professionals, and homeowners as a solutions provider for re-imagining how buildings, people and the elements interact. By combining precision engineering and outstanding design options across more than 20 unique systems, we advance design possibilities beyond the conventional for almost any space.

 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
 
          A.Folding Glazed Wall Systems:
          ** NOTE TO SPECIFIER ** Nanawall also supplies folding glazed wall systems of the following types. Contact Nanawall or go to the website for more information.
Wood-framed and aluminum-clad-wood-framed folding glass wall systems.
Minimal monumental, multi-track, thermally-broken sliding glass wall system.
Exterior all-glass window wall systems.
Aluminum-framed window systems.
Wood-framed and aluminum-clad-wood-framed window systems.
Delete items below not required for project.
          1.Standard, aluminum-framed folding glass wall systems. (SL45)
          2.Thermally-broken aluminum-framed folding glass wall systems. (SL60 and SL70)
          3.Single-track sliding glass wall systems. (HSW60)
          4.Interior all-glass window wall systems. (HSW75)
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 07 91 23 - Backer Rods.
 
          B.Section 08 83 13 - Mirrored Glass Glazing.
 
          1.3SUBMITTALS
 
          A.Submit under provisions of Section 01 30 00 - Administrative Requirements.
 
          B.Product Data: Manufacturer's data sheets on each product to be used, including:
          1.Preparation instructions and recommendations.
          2.Storage and handling requirements and recommendations.
          3.Independently tested data listing performance criteria and Owner's manual including installation instructions and methods.
 
          C.Product Drawings: Indicate dimensioning, direction of swing, pivot or slide, configuration, swing panels, typical head jamb, side jambs and sill details, type of glazing material and handle height.
          1.Provide elevations indicating rough opening requirements and details for field-applied components.
 
          D.Contract Closeout Submittal: Submit Owner's Manual from manufacturer. Identify Owner's Manual with project name, location and completion date, type and size of unit installed.
 
          1.4QUALITY ASSURANCE
 
          A.Manufacturer: Provide complete, precision built, engineered, pre-fitted unit by a single source manufacturer with at least 30 year experience in providing folding/sliding door systems for large openings in the North American market.
 
          B.Installer Qualifications:
          1.Installer experienced in the installation of manufacturer's products or other similar products for large openings.
          2.Installer to provide reference list of at least 3 projects of similar scale and complexity successfully completed in the last 3 years.
          3.Provide project names, locations, completion dates, names and telephone numbers of General Contractor and Owner's contact person.
          ** NOTE TO SPECIFIER ** Delete if longer warranty is not required.
          4.Installer certified by manufacturer.
 
          1.5DELIVERY, STORAGE, AND HANDLING
 
          A.Deliver materials to job site in sealed, unopened cartons or crates.
          1.Upon receipt, inspect the shipment to ensure it is complete, in good condition and meets project requirements.
 
          B.Store products in manufacturer's unopened packaging until ready for installation. Store flat in a well ventilated area out of direct sunlight under cover in a clean and dry location. Protect units against weather and defacement or damage from construction activities, especially to the edges of panels.
 
          1.6PROJECT CONDITIONS
 
          A.Contractor shall field verify dimensions of rough openings (R.O.) and inset components. Mark field measurements on shop drawing submittal.
 
          B.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.
 
          1.7WARRANTY
 
          A.Provide manufacturer's standard warranty against defects in materials and workmanship and as follows:
          1.Rollers: 10 years.
          2.Seal Failure of Insulated Glazing: 10 years.
          3.All Other Components (excluding screens): Five years beginning with the earliest of 120 days from date of delivery by manufacturer or date of Substantial Completion.
          ** NOTE TO SPECIFIER ** Delete the following option unless specifying manufacturer certified installer in Article for Quality Assurance. When certified installer is used, 10 year warranty is available.
          4.All Other Components (excluding screens and clear gasket UV resistant): 10 years beginning with the earliest of 120 days from date of delivery by manufacturer or Date of Substantial Completion if installed by manufacturer's certified trained installer.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: Nana Wall Systems, Inc., which is located at: 100 Meadowcreek Dr. Suite 250; Corte Madera, CA 94925; Toll Free Tel: 800-873-5673; Tel: 415-383-3148; Fax: 415-383-0312; Email: request info; Web: https://www.nanawall.com
          ** NOTE TO SPECIFIER ** Delete two of the following two paragraphs; coordinate with requirements of Division 01 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.2STANDARD ALUMINUM-FRAMED FOLDING GLASS WALL SYSTEM
 
          A.Basis of Design: Model SL45. Monumental aluminum folding glass wall systems manufactured by Nana Wall Systems, Incorporated.
          1.Performance Requirements:
          a.Provide from manufacturer that has independently tested typical units. Testing results to include air infiltration in accordance with ASTM E283, water penetration in accordance with ASTM E547, structural loading in accordance with ASTM E330, and forced entry in accordance with AAMA 1303 and AAMA 1304 or ASTM F842.
          ** NOTE TO SPECIFIER ** Delete wind loading paragraph below if not required to meet wind loading requirements.
          b.Florida Product Approval for Wind Loading: Units tested to AAMA 101/I.S.2/A440 and approved according to the Florida Building Code 2014, Section 1710.5, for panel sizes subject to manufacturer size charts.
          1)Product Approval number: FL24518: Units with panel sizes up to 43 inch (1.07 m) wide x 120 inch (3.05 m) high; subject to manufacturer size chart.
          ** NOTE TO SPECIFIER ** Units rated STC 30 to STC 45 are possible depending on glass type and panel size track limitations.
          c.Noise Reduction: STC ___; tested according to ASTM E90 with ratings determined by ASTM E1332.
          ** NOTE TO SPECIFIER ** EPA Energy Star. For guidance purposes only as Nana Wall Systems is not a participant of the Energy Star Program. Refer to Nana Wall Systems.
          d.EPA Energy Star: Unit with specific glazing to comply with US Environmental Protection Agency Energy Star Program requirements.
          e.Forced Entry (AAMA 1303.5 and AAMA CAWM 300): Meets requirements.
          f.Swing Panel - Operation / Cycling Performance (AAMA 920): 500,000 cycles.
          g.Thermal Performance U-factor: NFRC 100 rated, certified and labeled (shown in manufacturer's latest published data for glazing and sill specified).
          h.Condensation Resistance Factor (CRF): NFRC 500 rated, certified and labeled.
          2.Fabrication: Extruded aluminum frame and panel profiles. Corner connectors, hinges, sliding and folding hardware, locking hardware and handles, glass and glazing, and weather stripping as specified.
          a.Factory pre-assembled. Shipped with components and installation instructions.
          3.Frame and Panels: Manufacturer's standard profiles. Head jamb, side jambs, and panels with dimensions shown on the Drawings.
          ** NOTE TO SPECIFIER ** The manufacturer's weather stripping is determined at the factory by the direction of swing, the panel configuration, the type of locking and the type of sill.
          4.Weather Stripping: Double layer EPDM between panels and EPDM gasket and Q-Lon gasket or brush seal between panel and frame or brush seals with a two-layer fiberglass reinforced polyamide fin attached at both inner and outer bottom edge of door panels, with a recessed sill or on frame, for sealing between panels and between panel and frame.
          5.Sizes and Configurations: Refer to Drawings for custom dimensions within maximum frame sizes indicated in manufacturer's literature. Refer to Drawings for number of panels and configuration.
          6.Sliding and Folding Hardware:
          a.Manufacturer's combination sliding and folding hardware with top, bottom tracks and threshold.
          b.Running Carriages: Sealed, self-lubrication, ball bearing multi-rollers.
          c.For ADA Compliance: Gasket to cover the channel in the sill at swing doors.
          7.Mounting, Top Hung: For each pair of folding panels, cardanic, independently suspended, four wheeled upper running carriage and lower guide carriage. Coated with fiberglass reinforced polyamide.
          8.Adjustment: System capable of specified amount of adjustments without removing panels from tracks.
          ** NOTE TO SPECIFIER ** Delete panel lite/mullion options not required.
          9.Panel Lite/Mullion Configuration: Standard single lite.
          10.Panel Lite/Mullion Configuration: Horizontal mullions at specified heights from the bottom of the panel as shown on the Drawings.
          11.Panel Lite/Mullion Configuration: Simulated divided lites in pattern as shown on the Drawings.
          ** NOTE TO SPECIFIER ** Delete bottom rail width option not required.
          12.Bottom Rail Width: Standard bottom rail.
          13.Bottom Rail Width: Manufacturer's standard kick plate.
          ** NOTE TO SPECIFIER ** Fill in blank below with a value from 5 inches to 12 inches (127 to 305 mm).
          a.Kick plate Height (in/mm): ______.
          ** NOTE TO SPECIFIER ** Low iron, solar bronze, solar gray and laminated glass types are available. Select and edit glass types to meet building code, wind-load design, acoustic, bullet resistance, impact resistance, and/or security, and other project requirements. Verify full range of available options with size and weight requirements of Nana Wall model selected. Contact Nana Wall for availability of many commercial glass and glazing types.
          14.Vision Glass: As selected by Architect from manufacturer's full range of standard available options.
          a.Safety Glazing: In compliance with ASTM C1036, ASTM C1048, ANSI Z97.1 and CPSC 16CFR 1201.
          ** NOTE TO SPECIFIER ** For storefront units requiring acoustic performance keep the following subparagraph.Acoustical ratings are for the glass only and not the full panel system but will most likely be within 2 dB of the glass STC rating when the frame is added. Delete if not required.
          b.Acoustical Glass: Glass Acoustical Performance (ASTM E413 and ASTM E1332): STC.
          ** NOTE TO SPECIFIER ** Delete glass lite type options not required.
          c.Glass Lite Types: Tempered.
          d.Glass Lite Types: Laminated.
          e.Glass Lite Types: Tempered and laminated.
          ** NOTE TO SPECIFIER ** Delete glass treatment options not required.
          f.Glass Treatment: Standard.
          g.Glass Treatment: Low iron.
          h.Glass Treatment: Solar bronze.
          i.Glass Treatment: Solar gray.
          j.Glass Treatment: Bird safe.
          ** NOTE TO SPECIFIER ** Delete panel glazing subparagraphs below not required.
          15.Panel Glazing: Single. 1/4 inch (6 mm) thick.
          16.Panel Glazing: Double IGU. 3/4 inch (20 mm) thick.
          ** NOTE TO SPECIFIER ** Delete IGU Fill and Coating options not required. The IGU Fill is not required for single panel glazing.
          a.IGU Fill: Clear and air filled.
          b.IGU Fill: Low-E and Argon filled.
          c.IGU Fill: Low-E and air filled.
          ** NOTE TO SPECIFIER ** Delete system operation option not required.
          17.System Operation: Folding panel system.
          18.System Operation: Paired panel system.
          ** NOTE TO SPECIFIER ** Delete panel configuration options not required.
          19.Panel Configuration: Straight.
          20.Panel Configuration: Segmented curve.
          21.Panel Configuration: 90 degree angle turn/open corner.
          22.Panel Configuration: 135 degree angle turn.
          23.Panel Configuration: Window and door combination.
          ** NOTE TO SPECIFIER ** Delete panel operation options not required.
          24.Panel Operation: Inward opening unit.
          a.Stack Storage Configuration: Inside jamb.
          25.Panel Operation: Outward opening unit.
          a.Stack Storage Configuration: Outside jamb.
          26.Panel Operation: Center pivoted unit.
          a.Stack Storage Configuration: Center pivot.
          27.Panel Operation: Inward/outward combination opening unit.
          a.Stack Storage Configuration: Inside-outside combination.
          28.Panel Operation: Fold flat, against wall, full 180 degrees movement of door panel stack.
          a.Stack Storage Configuration: Fold flat against wall.
          ** NOTE TO SPECIFIER ** Delete aluminum thresholds options not required.
          29.Aluminum Thresholds: Standard sill. Finish to match panel.
          30.Aluminum Thresholds: Standard sill. Clear anodized.
          31.Aluminum Thresholds: Standard sill. Dark bronze anodized.
          32.Aluminum Thresholds: Flush sill. Clear anodized.
          33.Aluminum Thresholds: Flush sill. Dark bronze anodized.
          34.Aluminum Thresholds: Low profile saddle sill. Clear anodized.
          35.Aluminum Thresholds: Low profile saddle sill. Dark bronze anodized.
          36.Aluminum Thresholds: Surface mounted interior sill. Clear anodized.
          37.Aluminum Thresholds: Surface mounted interior sill. Dark bronze anodized.
          ** NOTE TO SPECIFIER ** Select a performance criteria paragraph below to match choice of panel operation and choice of aluminum thresholds. Delete performance criteria options not required. Note that not all combinations of panel operation and aluminum thresholds will result in a corresponding performance criteria paragraph. It is expected the installed system's performance would be not more than 2/3rds of the following certified laboratory test data in accordance with AAMA 502. Flush Sills do not have water penetration ratings.
          38.Performance Criteria (Lab Tested): Standard Sill - Inward or Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.27 cu ft per min per sq ft (1.38 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547):
          1)No uncontrolled water leakage at static test pressure of 1.56 psf (75 Pa).
          2)With water spray at 3.1 gal per sq ft per min (2.10 L per sq m per sec), no uncontrolled water entry at 2.86 psf (135 Pa).
          c.Structural Load Deflection (ASTM E330): Pass (for units with reinforced locking).
          1)Design Pressure Positive: 35 psf (1675 Pa).
          2)Design Pressure Negative: 35 psf (1675 Pa).
          39.Performance Criteria (Lab Tested): Flush Sill - Inward or Outward Opening.
          a.Air Infiltration (ASTM E283):
          b.Structural Load Deflection (ASTM E330): Pass (for units with reinforced locking).
          1)Design Pressure Positive: 35 psf (1675 Pa).
          2)Design Pressure Negative: 35 psf (1675 Pa).
          40.Performance Criteria (Lab Tested): Low Profile Saddle Sill - Inward or Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.25 cu ft per min per sq ft (1.28 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.78 cu ft per min per sq ft (6.66 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547):
          1)No uncontrolled water leakage at a static test pressure of 3.76 psf (180 Pa).
          c.Structural Load Deflection (ASTM E330): Pass (for units with reinforced locking).
          1)Design Pressure Positive: 35 psf (1675 Pa).
          41.Aluminum Extrusion: AIMgSi0.5 alloy, 6063-T5 (F-22 - European standard).
          a.Thickness: 0.078 inch (2.0 mm) nominal.
          ** NOTE TO SPECIFIER ** Delete aluminum finish options not required.
          42.Aluminum Finish: Anodizing per AAMA 611.
          NOTE TO SPECIFIER: Delete option not required.
          a.Dark bronze anodized.
          b.Clear anodized.
          **NOTE TO SPECIFIER ** If choosing a powder coat finish, delete option not required; either the AAMA 2604 option or the AAMA 2605 option. Delete both options if not choosing a powder coated finish.
          43.Aluminum Finish: Powder coating per AAMA 2604.
          ** NOTE TO SPECIFIER ** Delete options not required.
          a.Color as selected from manufacturer's 50 standard color selections.
          b.RAL high gloss finish, standard color as selected.
          c.RAL matte finish, standard color as selected.
          d.PVDF Kynar finish, standard color as selected.
          e.Wood grain, standard pattern as selected.
          44.Aluminum Finish: Powder coating per AAMA 2605.
          ** NOTE TO SPECIFIER ** Delete options not required.
          a.Color as selected from manufacturer's 50 standard color selections.
          b.RAL high gloss finish, standard color as selected.
          c.RAL matte finish, standard color as selected.
          d.PVDF Kynar finish, standard color as selected.
          45.Aluminum Finish: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete hinges option not required.
          46.Hinges: Manufacturer's standard zinc die cast powder coated hinges that are closest to match to finish of frame and panels. Stainless steel security hinge pins with set-screws.
          47.Hinges: Stainless steel. Stainless steel security hinge pins with set-screws.
          48.Screws: Stainless steel, for connecting frame components.
          49.Folding Door Hardware:
          ** NOTE TO SPECIFIER ** Delete locking option not required.
          a.Locking: Standard profile cylinder. Finish to match locking hardware and handles.
          ** NOTE TO SPECIFIER ** Delete key type not required.
          1)Keying: For applications with multiple units, all keyed alike.
          2)Keying: For applications with multiple units, all keyed independently.
          b.Locking: Adapter for small format interchangeable core (SFIC); core furnished by others. Finish to match locking hardware and handles.
          c.Locking Hardware and Handles:
          ** NOTE TO SPECIFIER ** Delete main entry panel options not required.
          1)Main Entry Panels for Models with Swing Panels: Manufacturer's standard lever handles on the inside and outside.
          a)Primary Panel Hardware: Standard lockset with lockable latch. Multi-point locking with concealed dead bolt and rods at top and bottom of panel.
          1)Depression of handles withdraws latch.
          2)Lifting of handles engages rods.
          3)Key or thumb turn engages deadbolt and operates lock.
          b)Secondary Swing Panel: Dummy handles. Concealed flush bolts operating rods at top and bottom.
          2)Main Entry Panels for Models with Swing Panels: Manufacturer's push/pull handles. Separate lockset. Dead bolt.
          ** NOTE TO SPECIFIER ** The following option is recommended with a door closer, but note that to slide the swing panel, the door closer will need to be disengaged if the swing panel is not attached to a side jamb. Delete one of the two following options not required.
          3)Main Entry Panels for Models with a Swing Panel: Field installed panic device by others.
          4)Main Entry Panels for Models with a Swing Panel: Provide lever handles on the inside and outside with single action, emergency egress, interconnected lock.
          5)Main Entry Panels on Inswing Models without a Swing Panel:
          a)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          b)Lockset Operation: Key turn from the outside and thumb turn from the inside.
          ** NOTE TO SPECIFIER ** Key operation from the inside may not meet egress requirements.
          6)Main Entry Panels on Outswing Models without a Swing Panel:
          a)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          b)Lockset Operation: Key turn from the outside and key turn from the inside.
          ** NOTE TO SPECIFIER ** The option below is operable from inside only and there is no latch.
          7)Main Entry Panels for Models with a Main Entry Panel: Manufacturer's handle on inside with concealed two-point locking hardware operated by 180 degree turn of handle.
          8)Aluminum Locking Rods:
          a)Rod Stroke: 15/16 inch (24 mm).
          b)End Caps: Fiberglass reinforced meeting structural loading requirements of application. On top and bottom.
          ** NOTE TO SPECIFIER ** Delete bi-folding panels option not required.
          9)Bi-folding Panels: Manufacturer's handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          a)Face applied flush bolts not acceptable.
          10)Bi-folding Panels: Manufacturer's removable custodial handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          a)Face applied flush bolts not acceptable.
          11)Handle Height: 41-3/8 inches (1050 mm) centered from bottom of panel or as otherwise indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete hardware and handle finish option not required.
          12)Hardware and Handle Finish: Stainless steel in titanium black finish.
          13)Hardware and Handle Finish: Stainless steel in brushed satin finish.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.3THERMALLY BROKEN ALUMINUM-FRAMED FOLDING GLASS WALL SYSTEMS
          ** NOTE TO SPECIFIER ** Delete basis of design paragraph not required.
 
          A.Basis of Design: Model SL60. Thermally broken aluminum-framed folding glass wall system, top supported or floor mounted as manufactured by Nana Wall Systems, Incorporated.
          1.Performance Requirements:
          a.Provide from manufacturer that has independently tested typical units. Testing results to include air infiltration in accordance with ASTM E283, water penetration in accordance with ASTM E 547, structural loading in accordance with ASTM E330, and forced entry in accordance with AAMA 1303 and AAMA 1304 or ASTM F842.
          ** NOTE TO SPECIFIER ** Delete wind loading paragraph below if not required to meet wind loading requirements.
          b.Florida Product Approval for Wind Loading: Units tested to AAMA/WDMA/CSA 101/I.S.2/A440 and approved according to the Florida Building Code 2014, Section 1710.5, for panel sizes subject to manufacturer size charts.
          1)Product Approval Number: FL24434. Approved for use outside hurricane zones (HVHZ) with a Design Pressure of plus or minus 45 psf. for tested panel size.
          ** NOTE TO SPECIFIER ** Units rated STC 30 to STC 45 are possible depending on glass type and panel size track limitations.
          c.Noise Reduction: STC ___; tested according to ASTM E90 with ratings determined by ASTM E1332.
          ** NOTE TO SPECIFIER ** The NFRC 100, 200, 400 and 500 ratings of the Folding Glass Storefront System meet Prescriptive Method requirements for U-factor, SHGC, Air Leakage and CRF of California Title 24, Chapter 3, Building Envelope Requirements. Delete if not required.
          d.Thermal Performance: Unit to comply with the U value, rated, certified, labeled or simulated in accordance with NFRC 100, shown in manufacturer's latest published data for the glazing and sill specified.
          e.Solar Heat Gain Coefficient (SHGC) Visible Light Transmission (VT): NFRC 200 rated, certified and labeled (shown in manufacturer's latest published data for the glazing specified).
          f.Air Leakage: NFRC 400 rated, certified and labeled.
          g.Condensation Resistance Factor (CRF): NFRC 500 rated, certified and labeled.
          h.System - Life Cycle Performance (DIN EN 1191/12400): Pass; 20,000 cycles.
          i.Forced Entry (AAMA 1304): Meets requirements.
          ** NOTE TO SPECIFIER ** EPA Energy Star. For guidance purposes only as Nana Wall Systems is not a participant of the Energy Star Program. Refer to Nana Wall Systems.
          j.EPA Energy Star: Unit with specific glazing to comply with US Environmental Protection Agency Energy Star Program requirements. Meets requirements with certain, specific glass.
          2.Frames and Panels:
          a.Extruded aluminum frame and panel profiles. Corner connectors, hinges, sliding and folding hardware, locking hardware and handles, glass and glazing, and weather stripping as specified.
          1)Factory pre-assembled. Shipped with components and installation instructions.
          b.Manufacturer's standard profile, head jamb, side jambs, and panels with dimensions shown on the Drawings.
          c.Sizes and Configurations: Refer to Drawings for custom dimensions within maximum frame sizes indicated in manufacturer's literature. Refer to Drawings for number of panels and configuration.
          d.Panel Size (W x H): As indicated on Drawings.
          e.Top Track and Side Jambs Depth: 2-5/8 inch (66 mm).
          f.Stile and Rail Depth: 2-5/16 inch (59 mm).
          ** NOTE TO SPECIFIER ** Delete bottom rail height option not required.
          g.Bottom Rail Height: 2-3/8 inches (60 mm)
          h.Bottom Rail Height: Manufacturer's standard kick plate with height indicated.
          ** NOTE TO SPECIFIER ** Fill in blank with a value from 6 to 12 inches (152 and 305 mm) high.
          1)Kick Plate Height (in/mm): ______.
          ** NOTE TO SPECIFIER ** The weather stripping is determined at the factory by the direction of swing, the panel configuration, the type of locking and the type of sill.
          3.Weather Stripping: Manufacturer's double layer EPDM between panels and EPDM gasket and Q-Lon gasket or brush seal between panel and frame or brush seals with two-layer polyamide fin attached to inner and outer edge of door panels with a recessed sill or on frame for sealing between panels and between panel and frame.
          ** NOTE TO SPECIFIER ** Delete panel glazing options not required.
          4.Panel Glazing: Double IGU; 15/16 inch (24 mm) thick.
          5.Panel Glazing: Triple IGU; 1-3/8 inch (35 mm) thick.
          ** NOTE TO SPECIFIER ** Delete panel lite/mullion configuration options not required. Single lite is standard. Refer to manufacturer's size chart for glass panel sizes requiring the use of horizontal mullions.
          6.Panel Lite/Mullion Configuration: Standard single lite.
          7.Panel Lite/Mullion Configuration: Horizontal mullions at specified heights from bottom of the panel as shown on the Drawings.
          8.Panel Lite/Mullion Configuration: Simulated divided lites in pattern as shown on the Drawings.
          ** NOTE TO SPECIFIER ** Delete panel operation option not required.
          9.Panel Operation: Inward opening unit.
          a.Stack Storage Configuration: Inside jamb.
          10.Panel Operation: Outward opening unit.
          a.Stack Storage Configuration: Outside jamb.
          ** NOTE TO SPECIFIER ** Delete swing direction option not required.
          11.Swing Direction: On configurations with a pair of swing panels, looking from inside, primary swing panel on the left
          12.Swing Direction: On configurations with a pair of swing panels, looking from inside, primary swing panel on the right.
          13.Panel Pairing Configuration: Number of panels ganged and attached to each jamb as indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete aluminum threshold options not required.
          14.Aluminum Thresholds: Higher weather performance raised sill. Thermally broken with polyamide. Finish to match panel finish.
          15.Aluminum Thresholds: Flush sill. Thermally broken with polyamide. Clear anodized.
          16.Aluminum Thresholds: Flush sill. Thermally broken with polyamide. Dark bronze anodized.
          17.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Clear anodized.
          18.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Dark bronze anodized.
          19.Aluminum Thresholds: Intermediate sill. Thermally broken with polyamide. Clear anodized.
          20.Aluminum Thresholds: Intermediate sill. Thermally broken with polyamide. Dark bronze anodized.
          21.Aluminum Thresholds: Surface mounted interior sill. Clear anodized.
          22.Aluminum Thresholds: Surface mounted interior sill. Dark bronze anodized.
          23.Aluminum Thresholds: Minimal interior sill. Clear anodized.
          24.Aluminum Thresholds: Minimal interior sill. Dark bronze anodized.
          ** NOTE TO SPECIFIER ** Select a performance criteria paragraph below to match choice of aluminum threshold and choice of opening direction. Delete performance criteria paragraphs not required. Note that if aluminum thresholds/interior sills are selected, there will be no corresponding performance criteria paragraphs. Weeps, when required, are field drilled by the installer to manufacturer's requirements. It is expected the installed system's performance would be not more than 2/3rds of the following certified laboratory test data in accordance with AAMA 502.
          25.Performance Criteria (Lab Tested): Standard Flush Sill - Inward/Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.10 cu ft per min per sq ft (0.82 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.37 cu ft per min per sq ft (1.69 L per sec per sq m).
          b.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 45 psf (2160 Pa).
          c.Swing Panel with Surface Mounted Hinges - Operation / Cycling Performance (AAMA 920): 500,000 cycles.
          26.Performance Criteria (Lab Tested): Low Profile Saddle Sill - Inward/Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.10 cu ft per min per sq ft (0.82 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.37 cu ft per min per sq ft (1.69 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547):No uncontrolled water leakage at a static test pressure of 5.43 psf (260 Pa) with weeps.
          c.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 45 psf (2160 Pa).
          d.Swing Panel with Surface Mounted Hinges - Operation / Cycling Performance (AAMA 920): 500,000 cycles.
          27.Performance Criteria (Lab Tested): Intermediate Sill - Inward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.05 cu ft per min per sq ft (0.09 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.13 cu ft per min per sq ft (0.67 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at 7.5 psf (360 Pa).
          c.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 45 psf (2160 Pa).
          28.Performance Criteria (Lab Tested): Intermediate Sill - Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.02 cu ft per min per sq ft (0.07 L per sec per sq m.)
          2)At 6.24 psf (300 Pa): 0.10 cu ft per min per sq ft (0.51 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at 7.5 psf (360 Pa).
          c.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 45 psf (2160 Pa).
          29.Performance Criteria (Lab Tested): Higher Weather Performance Raised Sill - Inward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.02 cu ft per min per sq ft (0.10 L per sec per sq m) or (0.25 cu m per hour per m).
          2)At 6.24 psf (300 Pa): 0.06 cu ft per min per sq ft (0.31 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water entry at 7.5 psf (360 Pa).
          c.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 45 psf (2160 Pa).
          30.Performance Criteria (Lab Tested): Higher Weather Performance Raised Sill - Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.01 cu ft per min per sq ft (0.05 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.01 cu ft per min per sq ft (0.05 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at 7.5 psf (360 Pa).
          c.Structural Loading (ASTM E330): DP-40 and DP-45.
          1)Design Pressure Positive: 45 psf (2160 Pa).
          2)Design Pressure Negative: 40 psf (1920 Pa).
          ** NOTE TO SPECIFIER ** Delete burglary resistance subparagraphs below if not required. These two additional security options are available for an upcharge.
          31.Unit Burglary Resistance: EN 1627-30, Class RC2/ RC2N (Resistance Class 2) certified.
          32.Lockset Burglary Resistance: PAS 24 certified.
          ** NOTE TO SPECIFIER ** See manufacturer Drawings for selected custom dimensions within maximum frame sizes possible as indicated in manufacturer's literature. See Drawings for selected number of panels and configuration.
          33.Panel Configuration: Straight.
          ** NOTE TO SPECIFIER ** Delete mounting option not required.
          34.Mounting: Top hung. Cardanic, independently suspended, four wheeled upper running carriage and lower guide carriage. Coated with fiberglass reinforced polyamide.
          a.Running Carriage Height Adjustment: 1/4 inch (6 mm) up and down.
          35.Mounting: Floor track supported. Upper guide carriage and lower running carriage with two vertical stainless steel wheels and two horizontal wheels. Vertical wheels ride on Type 304 stainless steel guide track covers over full length of sill track and lie above the water run-off level. Carrying capacity of lower running carriage to be 220 lbs (100 kg).
          ** NOTE TO SPECIFIER ** Corner connectors are only available in powder coated finishes, if anodized panel and frame finishes are selected, there may be aesthetic issues.
          36.Corner Fittings: Thermally broken, die cast zinc multi-functional corner fittings with carriage connectors, hinges and hinge pins as required. On all four corners of panels.
          a.Finish: Powder coated, closest match to finish of frame and panels.
          37.Fasteners: Tapered pins or machine screws for connecting frame components.
          ** NOTE TO SPECIFIER ** Low iron, solar bronze, solar gray and laminated glass types are available. Select and edit glass types to meet building code, wind-load design, acoustic, bullet resistant, impact resistance, and/or security, and other project requirements. Verify full range of available options with size and weight requirements of Nana Wall model selected. Contact Nana Wall for availability of many commercial glass and glazing types.
          38.Vision Glass: As selected by Architect from manufacturer's full range of standard available options.
          a.Safety Glazing: In compliance with ASTM C1036, ASTM C1048, ANSI Z97.1 and CPSC 16CFR 1201.
          ** NOTE TO SPECIFIER ** For storefront units requiring acoustic performance keep the following subparagraph. Edit to suit project conditions. Acoustical ratings are for the glass only and not the full panel system but will most likely be within 2-3 dB of the glass STC rating when the frame is added. Delete if not required.
          b.Acoustical Glass: Glass Acoustical Performance (ASTM E413 and ASTM E1332): STC.
          ** NOTE TO SPECIFIER ** Delete glass type lite options not required.
          c.Glass Lite Types: Tempered.
          d.Glass Lite Types: Laminated.
          e.Glass Lite Types: Tempered and laminated.
          ** NOTE TO SPECIFIER ** Delete glass treatment options not required.
          f.Glass Treatment: Standard.
          g.Glass Treatment: Low iron.
          h.Glass Treatment: Solar bronze.
          i.Glass Treatment: Solar gray.
          j.Glass Treatment: Bird safe.
          ** NOTE TO SPECIFIER ** Delete IGU Fill and Coating options not required. A Panel Glazing option must be selected in order to specify the IGU Fill. The IGU Fill is not required for single panel glazing.
          k.IGU Fill: Clear and air filled
          l.IGU Fill: Low-E and air filled.
          m.IGU Fill: Low-E and Argon filled.
          n.IGU Fill: Low-E and Krypton filled.
          39.Aluminum Extrusion: AIMgSi0.5 alloy, 6063-T5 (F-22 - European standard).
          a.Thickness: 0.078 inch (2.0 mm) nominal.
          b.Thermally broken with polyamide plastic reinforced with glass fibers.
          ** NOTE TO SPECIFIER ** Delete aluminum finish options not required.
          40.Aluminum Finish: Anodizing per AAMA 611.
          ** NOTE TO SPECIFIER ** Delete option not required.
          a.Interior: Dark bronze anodized.
          b.Interior: Clear anodized.
          c.Exterior: Dark bronze anodized.
          d.Exterior: Clear anodized.
          **NOTE TO SPECIFIER ** If choosing powder coat finish, delete option not required; either the AAMA 2604 option or the AAMA 2605 option. Delete both if not specifying a powder coat finish. Dual color options are only available with powder coated finishes.
          41.Aluminum Finish: Powder Coating per AAMA 2604.
          ** NOTE TO SPECIFIER ** Delete interior finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selections.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: Wood grain, standard pattern as selected.
          e.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete exterior finish options not required.
          f.Exterior: Match interior finish specified.
          g.Exterior: Color as selected from manufacturer's 50 standard color selections.
          h.Exterior: RAL high gloss finish, standard color as selected.
          i.Exterior: RAL matte finish, standard color as selected.
          j.Exterior: Wood grain, standard pattern as selected.
          k.Exterior: Custom finish as selected by the Architect.
          42.Aluminum Finish: Powder Coating per AAMA 2605.
          ** NOTE TO SPECIFIER ** Delete interior finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selections.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete exterior finish options not required.
          e.Exterior: Match interior finish specified.
          f.Exterior: Color as selected from manufacturer's 50 standard color selections.
          g.Exterior: RAL high gloss finish, standard color as selected.
          h.Exterior: RAL matte finish, standard color as selected.
          i.Exterior: Custom finish as selected by the Architect.
          43.Sliding and Folding Hardware: Manufacturer's combination sliding and folding hardware with top, bottom tracks and threshold.
          a.Running Carriages: Sealed, self-lubricating, ball bearing multi-rollers.
          b.Surface mounted hinges and running carriages will not be allowed.
          c.Weight of panels supported by the bottom of the track will not be allowed.
          d.Folding Door Hardware:
          ** NOTE TO SPECIFIER ** Delete locking type not required.
          1)Locking: Standard profile cylinder. Finish to match locking hardware and handles.
          ** NOTE TO SPECIFIER ** Delete key type not required.
          a)Keying: For applications with multiple units, all keyed alike.
          b)Keying: For applications with multiple units, all keyed independently.
          2)Locking: Adapter for small format interchangeable core (SFIC); core furnished by others. Finish to match locking hardware and handles.
          3)Locking Hardware and Handles:
          ** NOTE TO SPECIFIER ** Delete main entry panels options not required.
          a)Main Entry Panels for Models with Swing Panels: Manufacturer's standard lever handles on the inside and outside.
          1)Primary Panel Hardware: Standard lockset with lockable latch. Multi-point locking with concealed dead bolt and rods at top and bottom of panel.
          a)Depression of handles withdraws latch.
          b)Lifting of handles engages rods.
          c)Key or thumb turn engages deadbolt and operates lock.
          2)Secondary Swing Panel: Dummy handles. Concealed flush bolts operating rods at top and bottom.
          b)Main Entry Panels for Models with Swing Panels: Manufacturer's push/pull handles. Separate lockset. Dead bolt.
          ** NOTE TO SPECIFIER ** The following option is recommended with a door closer, but note that to slide the swing panel, the door closer will need to be disengaged if the swing panel is not attached to a side jamb.
          c)Main Entry Panels for Models with a Swing Panel: Field installed panic device by others.
          d)Main Entry Panels on Inswing Models without a Swing Panel:
          1)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          2)Lockset Operation: Key turn from the outside and thumb turn from the inside.
          ** NOTE TO SPECIFIER ** Key operation from the inside may not meet egress requirements.
          e)Main Entry Panels on Outswing Models without a Swing Panel:
          1)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          2)Lockset Operation: Key turn from the outside and key turn from the inside.
          ** NOTE TO SPECIFIER ** The option below is operable from inside only and there is no latch.
          f)Main Entry Panels for Models with a Main Entry Panel: Manufacturer's handle on inside with concealed two-point locking hardware operated by 180 degree turn of handle.
          g)Aluminum Locking Rods:
          1)Rod Stroke: 15/16 inch (24 mm).
          2)End Caps: Fiberglass reinforced meeting structural loading requirements of application. On top and bottom.
          ** NOTE TO SPECIFIER ** Delete bi-folding panels option not required.
          h)Bi-folding Panels: Manufacturer's handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolts not acceptable.
          i)Bi-folding Panels: Manufacturer's removable custodial handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolts not acceptable.
          j)Handle Height: 41-3/8 inches (1050 mm) centered from bottom of panel or as otherwise indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete hardware and handle finish option not required.
          k)Hardware and Handle Finish: Stainless steel in titanium black finish.
          l)Hardware and Handle Finish: Stainless steel in brushed satin finish.
 
          B.Basis of Design: Model SL70. Monumental, thermally broken aluminum-framed folding glass wall system, floor mounted track supported as manufactured by Nana Wall Systems, Incorporated.
          1.Performance Requirements:
          a.Provide from manufacturer that has independently tested typical units. Testing results to include air infiltration in accordance with ASTM E283, water penetration in accordance with ASTM E 547, structural loading in accordance with ASTM E330, and forced entry in accordance with AAMA 1303 and AAMA 1304 or ASTM F842.
          ** NOTE TO SPECIFIER ** Delete wind loading paragraph below if not required to meet wind loading requirements.
          b.Florida Product Approval for Wind Loading: Units tested to AAMA/WDMA/CSA 101/I.S.2/A440 and approved according to the Florida Building Code 2014, Section 1710.5, for panel sizes subject to manufacturer size charts.
          1)Product Approval Number: FL23502. Standard Units with panel sizes up to 36 inches (914 mm) wide x 96 inches (2438 mm) high; subject to manufacturer size chart.
          ** NOTE TO SPECIFIER ** Units rated STC 30 to STC 45 are possible depending on glass type and panel size track limitations.
          c.Noise Reduction: STC ___; tested according to ASTM E90 with ratings determined by ASTM E1332.
          ** NOTE TO SPECIFIER ** The NFRC 100, 200, 400 and 500 ratings of the Folding Glass Storefront System meet Prescriptive Method requirements for U-factor, SHGC, Air Leakage and CRF of California Title 24, Chapter 3, Building Envelope Requirements. Delete if not required.
          d.Thermal Performance: Unit to comply with the U value, rated, certified, labeled or simulated in accordance with NFRC 100, shown in manufacturer's latest published data for the glazing and sill specified.
          e.Solar Heat Gain Coefficient (SHGC) Visible Light Transmission (VT): NFRC 200 rated, certified and labeled (shown in manufacturer's latest published data for the glazing specified).
          f.Air Leakage: NFRC 400 rated, certified and labeled.
          g.Condensation Resistance Factor (CRF): NFRC 500 rated, certified and labeled.
          h.Swing Panel - Operation / Cycling Performance (AAMA 920): 500,000 cycles.
          i.System - Life Cycle Performance (DIN EN 1191/12400): 20,000 cycles.
          ** NOTE TO SPECIFIER ** EPA Energy Star. For guidance purposes only as Nana Wall Systems is not a participant of the Energy Star Program. Refer to Nana Wall Systems.
          j.EPA Energy Star: Unit with specific glazing to comply with US Environmental Protection Agency Energy Star Program requirements. Meets requirements with certain, specific glass.
          2.Frames and Panels:
          a.Extruded aluminum frame and panel profiles. Corner connectors, hinges, sliding and folding hardware, locking hardware and handles, glass and glazing, and weather stripping as specified.
          1)Factory pre-assembled. Shipped with components and installation instructions.
          b.Manufacturer's standard or post reinforced frame and panel profiles, with head track, side jambs and panels. Dimensions as shown on Drawings.
          c.Sizes and Configurations: Refer to Drawings for custom dimensions within maximum frame sizes indicated in manufacturer's literature. Refer to Drawings for number of panels and configuration.
          d.Panel Size (W x H): As indicated on Drawings.
          e.Top Track and Side Jambs Depth: 3-1/8 inch (80 mm).
          f.Stile and Rail Depth: 2-3/4 inch (70 mm).
          ** NOTE TO SPECIFIER ** Delete bottom rail width option not required.
          g.Bottom Rail Height: 2-5/16 inches (58 mm).
          h.Bottom Rail Height: Manufacturer's standard kick plate with height indicated.
          ** NOTE TO SPECIFIER ** Fill in blank below with a value from 6 inches to 12 inches (152 and 305 mm).
          1)Kick Plate Height (in/mm): ______.
          ** NOTE TO SPECIFIER ** The manufacturer's weather stripping is determined at the factory by the direction of swing, the panel configuration, the type of locking and the type of sill.
          3.Weather Stripping: Manufacturer's double layer EPDM between panels and EPDM gasket and Q-Lon gasket or brush seal between panel and frame or brush seals with two-layer polyamide fin attached to inner and outer edge of door panels with a recessed sill or on frame for sealing between panels and between panel and frame.
          ** NOTE TO SPECIFIER ** Delete panel glazing options not required.
          4.Panel Glazing: Double IGU; 15/16 inch (24 mm) thick.
          5.Panel Glazing: Double IGU; 1-3/8 inch (35 mm) thick.
          6.Panel Glazing: Triple IGU; 1-9/16 inch (40 mm) thick.
          ** NOTE TO SPECIFIER ** Delete panel lite/mullion options not required. Single lite is standard. Refer to manufacturer's size chart for glass panel sizes requiring the use of horizontal mullions.
          7.Panel Lite/Mullion Configuration: Standard single lite.
          8.Panel Lite/Mullion Configuration: Horizontal mullions at specified heights from bottom of the panel as shown on the Drawings.
          9.Panel Lite/Mullion Configuration: Simulated divided lites in pattern as shown on the Drawings.
          ** NOTE TO SPECIFIER ** Delete panel operation not required.
          10.Panel Operation: Inward opening unit.
          a.Stack Storage Configuration: Inside jamb.
          11.Panel Operation: Outward opening unit.
          a.Stack Storage Configuration: Outside jamb.
          ** NOTE TO SPECIFIER ** Delete swing direction option not required.
          12.Swing Direction: On configurations with a pair of swing panels, looking from inside, primary swing panel on the left.
          13.Swing Direction: On configurations with a pair of swing panels, looking from inside, primary swing panel on the right.
          14.Panel Pairing Configuration: Number of panels ganged and attached to each jamb as indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete aluminum threshold options not required.
          15.Aluminum Thresholds: Higher weather performance raised sill. Thermally broken with polyamide. Finish to match panel finish.
          16.Aluminum Thresholds: Flush sill. Thermally broken with polyamide. Clear anodized.
          17.Aluminum Thresholds: Flush sill. Thermally broken with polyamide. Dark bronze anodized.
          18.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Clear anodized.
          19.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Dark bronze anodized.
          20.Aluminum Thresholds: Surface mounted interior sill. Clear anodized.
          21.Aluminum Thresholds: Surface mounted interior sill. Dark bronze anodized.
          22.Aluminum Thresholds: Minimal interior sill. Clear anodized.
          23.Aluminum Thresholds: Minimal interior sill. Dark bronze anodized.
          ** NOTE TO SPECIFIER ** Select performance criteria paragraphs below to match choice of sill and choice of opening direction. Delete performance criteria paragraphs not required. Note that not all combinations of panel operation and aluminum thresholds will result in a corresponding performance criteria paragraph. Weeps, when required, are field drilled by the installer to manufacturer's requirements. It is expected that the installed system's performance would be not more than 2/3rds of the following certified laboratory test data in accordance with AAMA 502.
          24.Performance Criteria (Lab Tested): Standard Flush Sill - Inward Opening.
          a.Air Infiltration (ASTM E283) Inward Opening:
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.15 cu ft per min per sq ft (0.51 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.29 cu ft per min per sq ft (1.33 L per sec per sq m).
          b.Structural Loading (ASTM E330): Inward Opening.
          1)Wind load Resistance: Pass; C4.
          a)Design Pressure Positive: 70 psf (3350 Pa).
          b)Design Pressure Negative: 70 psf (3350 Pa).
          25.Performance Criteria (Lab Tested): Standard Flush Sill - Outward Opening.
          a.Air Infiltration (ASTM E283) Outward Opening:
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.14 cu ft per min per sq ft (0.56 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.30 cu ft per min per sq ft (1.49 L per sec per sq m).
          b.Structural Loading (ASTM E330): Outward Opening.
          1)Wind load Resistance: Pass; C4.
          a)Design Pressure Positive: 70 psf (3350 Pa).
          b)Design Pressure Negative: 70 psf (3350 Pa).
          26.Performance Criteria (Lab Tested): Low Profile Saddle Sill - Inward Opening.
          a.Air Infiltration (ASTM E283) Inward Opening:
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.15 cu ft per min per sq ft (0.51 L per sec per sq m).
          a)Without Weeps at 6.24 psf (300 Pa): 0.29 cu ft per min per sq ft (1.33 L per sec per sq m).
          b)With Weeps at 6.24 psf (300 Pa): 0.31 cu ft per min per sq ft (1.59 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at a static (with weeps) test pressure of 5.25 psf (250 Pa).
          c.Structural Loading (ASTM E330):
          1)Wind load Resistance: Pass; C4.
          a)Design Pressure Positive: 70 psf (3350 Pa).
          b)Design Pressure Negative: 70 psf (3350 Pa).
          27.Performance Criteria (Lab Tested): Low Profile Saddle Sill - Outward Opening.
          a.Air Infiltration (ASTM E283) Outward Opening:
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.14 cu ft per min per sq ft (0.56 L per sec per sq m).
          a)Without Weeps at 6.24 psf (300 Pa): 0.30 cu ft per min per sq ft (1.49 L per sec per sq m).
          b)With Weeps at 6.24 psf (300 Pa): 0.32 cu ft per min per sq ft (1.64 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at a static (with weeps) test pressure of 5.25 psf (300 Pa).
          c.Structural Loading (ASTM E330):
          1)Wind load Resistance: Pass; C4.
          a)Design Pressure Positive: 70 psf (3350 Pa).
          b)Design Pressure Negative: 70 psf (3350 Pa).
          28.Performance Criteria (Lab Tested): Higher Weather Performance Raised Sill - Inward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.02 to 0.16 cu ft per min per sq ft (0.41 to 1.54 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.20 to 0.30 cu ft per min per sq ft (1.02 to 1.54 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at a static test pressure of 9 psf (440 Pa).
          c.Dynamic Water Penetration (AAMA 520 / ASTM E2268):
          1)Performance Level 2 at 6-18 psf (300-860 Pa).
          d.Structural Load Deflection (TAS 202 / ASTM E330): DP-40 and DP-45.
          1)Wind load Resistance: Pass.
          a)Design Pressure Positive: 70 psf (3350 Pa); C4.
          b)Design Pressure Negative: 100 psf (4785 Pa); C3.
          29.Performance Criteria (Lab Tested): Higher Weather Performance Raised Sill - Outward Opening.
          a.Air Infiltration (ASTM E283):
          1)At static air pressure difference of 1.57 psf (75 Pa): 0.02 to 0.16 cu ft per min per sq ft (0.10 to 0.72 L per sec per sq m).
          2)At 6.24 psf (300 Pa): 0.08 to 0.30 cu ft per min per sq ft (0.36 to 1.54 L per sec per sq m).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at a static test pressure of 9 psf (440 Pa).
          c.Dynamic Water Penetration (AAMA 520 / ASTM E2268): Performance Level 1 at 5-15 psf (250-715 Pa).
          d.Structural Load Deflection (TAS 202 / ASTM E330): DP-40 and DP-45.
          1)Wind load Resistance: Pass.
          a)Design Pressure Positive: 100 psf (4785 Pa); C3.
          b)Design Pressure Negative: 70 psf (3350 Pa); C4.
          30.Forced Entry (AAMA 1304 / ASTM F842): Meets requirements for plus F1.
          31.Adjustment: Folding and sliding hardware capable of compensation and adjustment without removing panels from tracks.
          a.Width Adjustment: 1/16 inch (1.5 mm) per hinge.
          b.Height Adjustment: 1/16 inch (1.5 mm) up and down.
          ** NOTE TO SPECIFIER ** See manufacturer Drawings for selected custom dimensions within maximum frame sizes possible as indicated in manufacturer's literature. See Drawings for selected number of panels and configuration. Delete panel configuration options not required.
          32.Panel Configuration: Straight.
          33.Panel Configuration: Segmented curve.
          34.Panel Configuration: 90 degree angle turn/ open corner.
          35.Panel Configuration: 135 degree angle turn.
          36.Mounting: Upper guide carriage and lower running carriage with four vertical stainless steel wheels and two horizontal polyamide plastic wheels. The vertical wheels to ride on top of sill track and lie above the water run-off level. Carrying capacity of lower running carriage to be 440 lbs (200 kg).
          ** NOTE TO SPECIFIER ** Delete hinge option not required.
          37.Hinges: Zinc die cast with closest match to finish of frame and panels. Stainless steel security hinge pins and set-screws.
          38.Hinges: Stainless steel. Stainless steel security hinge pins and set-screws.
          39.Fasteners: Tapered pins or stainless screws for connecting frame components.
          ** NOTE TO SPECIFIER ** Low iron, solar bronze, solar gray and laminated glass types are available. Select and edit glass types to meet building code, wind-load design, acoustic, bullet resistant, impact resistance, and/or security, and other project requirements. Verify full range of available options with size and weight requirements of Nana Wall model selected. Contact Nana Wall for availability of many commercial glass and glazing types.
          40.Vision Glass: As selected by Architect from manufacturer's full range of standard available options.
          a.Safety Glazing: In compliance with ASTM C1036, ASTM C1048, ANSI Z97.1 and CPSC 16CFR 1201.
          ** NOTE TO SPECIFIER ** For storefront units requiring acoustic performance keep the following subparagraph. Edit to suit project conditions. Acoustical ratings are for the glass only and not the full panel system but will most likely be within 2-3 dB of the glass STC rating when the frame is added. Delete if not required.
          b.Acoustical Glass: Glass Acoustical Performance (ASTM E413 and ASTM E1332): STC.
          ** NOTE TO SPECIFIER ** Delete glass type lite options not required.
          c.Glass Lite Types: Tempered.
          d.Glass Lite Types: Laminated.
          e.Glass Lite Types: Tempered and laminated.
          ** NOTE TO SPECIFIER ** Delete glass treatment options not required.
          f.Glass Treatment: Standard.
          g.Glass Treatment: Low iron.
          h.Glass Treatment: Solar bronze.
          i.Glass Treatment: Solar gray.
          j.Glass Treatment: Bird safe.
          ** NOTE TO SPECIFIER ** Delete IGU Fill and Coating options not required. A Panel Glazing option must be selected in order to specify the IGU Fill. The IGU Fill is not required for single panel glazing.
          k.IGU Fill: Clear and air filled
          l.IGU Fill: Low-E and air filled.
          m.IGU Fill: Low-E and Argon filled.
          n.IGU Fill: Low-E and Krypton filled.
          41.Aluminum Extrusion: AIMgSi0.5 alloy, 6063-T5 (F-22 - European standard).
          a.Thickness: 0.078 inch (2.0 mm) nominal.
          b.Thermally broken with polyamide plastic reinforced with glass fibers.
          ** NOTE TO SPECIFIER ** Delete aluminum finish options not required.
          42.Aluminum Finish: Anodizing per AAMA 611.
          ** NOTE TO SPECIFIER ** Delete options not required.
          a.Interior: Dark bronze anodized.
          b.Interior: Clear anodized.
          c.Exterior: Dark bronze anodized.
          d.Exterior: Clear anodized.
          **NOTE TO SPECIFIER ** If choosing powder coat finish, delete either the AAMA 2604 option or the AAMA 2605 option. Delete both if not specifying a powder coat finish. Dual color options are only available with powder coated finishes.
          43.Aluminum Finish: Powder Coating per AAMA 2604.
          ** NOTE TO SPECIFIER ** Delete interior finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selections.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: PVDF Kynar finish, standard color as selected.
          e.Interior: Wood grain, standard pattern as selected.
          f.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete exterior finish options not required.
          g.Exterior: Match interior finish specified.
          h.Exterior: Color as selected from manufacturer's 50 standard color selections.
          i.Exterior: RAL high gloss finish, standard color as selected.
          j.Exterior: RAL matte finish, standard color as selected.
          k.Exterior: PVDF Kynar finish, standard color as selected.
          l.Exterior: Wood grain, standard pattern as selected.
          m.Exterior: Custom finish as selected by the Architect.
          44.Aluminum Finish: Powder Coating per AAMA 2605.
          ** NOTE TO SPECIFIER ** Delete interior finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selections.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: PVDF Kynar finish, standard color as selected.
          e.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete exterior finish options not required.
          f.Exterior: Match interior finish specified.
          g.Exterior: Color as selected from manufacturer's 50 standard color selections.
          h.Exterior: RAL high gloss finish, standard color as selected.
          i.Exterior: RAL matte finish, standard color as selected.
          j.Exterior: PVDF Kynar finish, standard color as selected.
          k.Exterior: Custom finish as selected by the Architect.
          45.Sliding and Folding Hardware: Manufacturer's combination sliding and folding hardware with top, bottom tracks and threshold.
          a.Running Carriages: Sealed, self-lubricating, ball bearing multi-rollers.
          b.Surface mounted hinges and running carriages will not be allowed.
          c.Weight of panels supported by the bottom of the track will not be allowed.
          d.Folding Door Hardware:
          ** NOTE TO SPECIFIER ** Delete locking type not required.
          1)Locking: Standard profile cylinder. Finish to match locking hardware and handles.
          ** NOTE TO SPECIFIER ** Delete key type not required.
          a)Keying: For applications with multiple units, all keyed alike.
          b)Keying: For applications with multiple units, all keyed independently.
          2)Locking: Adapter for small format interchangeable core (SFIC); core furnished by others. Finish to match locking hardware and handles.
          3)Locking Hardware and Handles:
          ** NOTE TO SPECIFIER ** Delete main entry panels options not required.
          a)Main Entry Panels for Models with Swing Panels: Manufacturer's standard lever handles on the inside and outside.
          1)Primary Panel Hardware: Standard lockset with lockable latch. Multi-point locking with concealed dead bolt and rods at top and bottom of panel.
          a)Depression of handles withdraws latch.
          b)Lifting of handles engages rods.
          c)Key or thumb turn engages deadbolt and operates lock.
          2)Secondary Swing Panel: Dummy handles. Concealed flush bolts operating rods at top and bottom.
          b)Main Entry Panels for Models with Swing Panels: Manufacturer's push/pull handles. Separate lockset. Dead bolt.
          ** NOTE TO SPECIFIER ** The following option is recommended with a door closer, but note that to slide the swing panel, the door closer will need to be disengaged if the swing panel is not attached to a side jamb.
          c)Main Entry Panels for Models with a Swing Panel: Field installed panic device by others.
          d)Main Entry Panels for Models with a Swing Panel: Provide lever handles on the inside and outside with single action, emergency egress, interconnected lock.
          e)Main Entry Panels on Inswing Models without a Swing Panel:
          1)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          2)Lockset Operation: Key turn from the outside and thumb turn from the inside.
          ** NOTE TO SPECIFIER ** Key operation from the inside may not meet egress requirements.
          f)Main Entry Panels on Outswing Models without a Swing Panel:
          1)Manufacturer's handle on inside and outside. Lockset with profile cylinder. Two point locking hardware operated by 180 degree turn of the handle.
          2)Lockset Operation: Key turn from the outside and key turn from the inside.
          ** NOTE TO SPECIFIER ** The option below is operable from inside only and there is no latch.
          g)Main Entry Panels for Models with a Main Entry Panel: Manufacturer's handle on inside with concealed two-point locking hardware operated by 180 degree turn of handle.
          h)Aluminum Locking Rods:
          1)Rod Stroke: 15/16 inch (24 mm).
          2)End Caps: Fiberglass reinforced meeting structural loading requirements of application. On top and bottom.
          ** NOTE TO SPECIFIER ** Delete bi-folding panels option not required.
          i)Bi-folding Panels: Manufacturer's handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolts not acceptable.
          j)Bi-folding Panels: Manufacturer's removable custodial handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolts not acceptable.
          k)Handle Height: 41-3/8 inches (1050 mm) centered from bottom of panel or as otherwise indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete finish not required.
          l)Hardware and Handle Finish: Stainless steel in titanium black finish.
          m)Hardware and Handle Finish: Stainless steel in brushed satin finish.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.4SINGLE-TRACK SLIDING GLASS WALL SYSTEMS
 
          A.Basis of Design: Model HSW60. Top-hung, single-track, interlocking, thermally broken aluminum framed storefront as manufactured by Nana Wall Systems, Incorporated.
          1.Performance Requirements:
          a.Provide from manufacturer that has independently tested typical units.
          1)Air infiltration per ASTM E283.
          2)Water penetration per ASTM E 547.
          3)Structural loading per ASTM E330.
          4)Forced entry per AAMA 1303 and AAMA 1304 or ASTM F842.
          b.Florida Product Approval for Wind Loading: Tested to AAMA 101/I.S.2/A440. Approved per Florida Building Code 2014, Section 1710.5 for panel sizes subject to manufacturer size charts.
          ** NOTE TO SPECIFIER ** Units rated STC 30 to STC 45 are possible depending on glass type and panel size track limitations.
          c.Noise Reduction: STC ___; tested according to ASTM E90 with ratings determined by ASTM E1332.
          ** NOTE TO SPECIFIER ** The NFRC 100, 200, 400 and 500 ratings meet Prescriptive Method requirements for U-factor, SHGC, Air Leakage and CRF of California Title 24, Chapter 3, Building Envelope Requirements. Delete if not required.
          d.Thermal Performance (U-factor): NFRC 100 rated, certified and labeled (shown in manufacturer's latest published data for glazing and sill specified).
          e.Solar Heat Gain Coefficient (SHGC) plus Visible Light Transmission (VT): NFRC 200 rated, certified and labeled (shown in manufacturer's latest published data for glazing specified).
          f.Air Leakage: NFRC 400 rated certified and labeled.
          g.Condensation Resistance Factor (CRF): NFRC 500 rated, certified and labeled.
          ** NOTE TO SPECIFIER ** EPA Energy Star. For guidance purposes only as Nana Wall Systems is not a participant of the Energy Star Program. Refer to Nana Wall Systems.
          h.EPA Energy Star: Unit with specific glazing to comply with US Environmental Protection Agency Energy Star Program requirements.
          i.The manufacturer must have a quality system registration per ISO 9001: 2015.
          j.The manufacturer must have an environmental management system registration per ISO 14001: 2015.
          2.Fabrication: Extruded aluminum frame and panel profiles, corner connectors and hinges, sliding hardware, locking hardware and handles, glass and glazing and weather stripping to construct a single track sliding glass wall.
          a.Factory pre-assembled. Shipped with components and installation instructions.
          b.Carefully match exposed work to produce continuity of line and design with all joints.
          c.No raw edges visible at joints.
          3.Frame and Panels: Manufacturer's standard profiles. Head track, stacking bays, side jambs, sliding panels, and swing panels.
          a.Dimensions shown on the Drawings.
          ** NOTE TO SPECIFIER ** The manufacturer's weather stripping is determined at the factory by the direction of swing, the panel configuration, the type of locking and the type of sill.
          4.Weather Stripping: Double layer EPDM between panels and EPDM gasket or brush seal between panel and frame brush seals with a two-layer fiberglass reinforced polyamide fin attached at both inner and outer bottom edge of door panels, with a recessed sill or on frame, for sealing between panels and between panel and frame.
          5.Sizes and Configurations: As indicated on Drawings for selected number and size of panels, location of swing panels, and location of tracks and stacking bays.
          ** NOTE TO SPECIFIER ** Delete panel type not required.
          a.Panel Type: Multiple unattached with Entry/Egress panel hinged to side jamb.
          b.Panel Type: Multiple unattached with Entry/Egress panel convertible to sliding panel.
          ** NOTE TO SPECIFIER ** Swing Panel Sizes (W x H): Up to 39 x 120 inch (1000 x 3048 mm).
Sliding Panel Sizes (W x H): Up to 54 x 120 inch (1372 x 3048 mm).
          c.Panel Size (W x H): As indicated on the Drawings.
          d.Corner Fittings: On all four corners of sliding panels and incorporated swing panels, thermally broken, die cast zinc multifunctional with carrier connectors, male and female locking receptacles. Hinges and hinge pins as required.
          1)Finish: Powder coated, closest match to finish of frame and panels.
          ** NOTE TO SPECIFIER ** Corner connectors are only available in powder-coated finishes. If anodized panel and frame finishes are selected, there may be aesthetic issues.
          2)Provide on the pivot side corner of the upper arm of the top rail of the incorporated swing panel a circular cover in polyamide with a silver gray finish.
          6.Sliding and Swinging Hardware: Manufacturer's standard hardware.
          a.For Each Sliding Panel: Two, three-wheeled, sintered bronze (oil impregnated) unidirectional sliding panel carriers with a one-wheeled, polyamide guide roller, attached to the panels with stainless steel rods.
          b.Carrying Capacity of Each Carrier: 330 lbs (150 kg).
          7.Mounting Type: Top-hung.
          a.Top Track Depth: 3-1/8 (80 mm).
          b.Panel Depth: 2-5/16 inches (59 mm).
          ** NOTE TO SPECIFIER ** Delete bottom rail height option not required.
          8.Bottom Rail Height: 2-3/8 inch (60 mm) for sliding panel and 4-5/16 inch (110 mm) incorporated swing panel.
          9.Bottom Rail Height: Manufacturer's standard kick plate with height indicated.
          ** NOTE TO SPECIFIER ** Fill in blank below with a value from 6 inches to 12 inches (152 and 305 mm) high.
          a.Kick Plate Height (in/mm): ______.
          ** NOTE TO SPECIFIER ** Low iron, solar bronze, solar gray and laminated glass types are available. Select and edit glass types to meet building code, wind-load design, acoustic, bullet resistant, impact resistant and/or security, and other project requirements. Verify full range of available options with size and weight requirements of Nana Wall model selected. Contact Nana Wall for availability of many commercial glass and glazing types.
          10.Vision Glass: As selected by Architect from manufacturer's full range of standard available options.
          a.Safety Glazing: In compliance with ASTM C1036, ASTM C1048, ANSI Z97.1 and CPSC 16CFR 1201.
          ** NOTE TO SPECIFIER ** For storefront units requiring acoustic performance, keep the following subparagraph. Acoustical ratings are for the glass only and not the full panel system but will most likely be within 2 dB of the glass STC rating when the frame is added. Delete if not required.
          b.Acoustical Glass: Glass Acoustical Performance (ASTM E413 and ASTM E1332): STC.
          ** NOTE TO SPECIFIER ** Delete glass lite type options not required.
          c.Glass Lite Types: Tempered.
          d.Glass Lite Types: Laminated.
          e.Glass Lite Types: Tempered and laminated.
          ** NOTE TO SPECIFIER ** Delete glass treatment options not required.
          f.Glass Treatment: Standard.
          g.Glass Treatment: Low iron.
          h.Glass Treatment: Solar bronze.
          i.Glass Treatment: Solar gray.
          j.Glass Treatment: Bird safe.
          ** NOTE TO SPECIFIER ** Delete IGU fill and coating options not required. A Panel Glazing option must be selected in order to specify the IGU Fill. The IGU Fill is not required for single panel glazing.
          k.IGU Fill: Clear and air filled
          l.IGU Fill: Low-E and air filled.
          m.IGU Fill: Low-E and Argon filled.
          n.IGU Fill: Low-E and Krypton filled.
          ** NOTE TO SPECIFIER ** Delete panel glazing subparagraphs below not required.
          11.Panel Glazing: Single; 1/4 inch (6 mm) thick.
          12.Panel Glazing: Double IGU; 15/16 inch (24 mm) thick.
          13.Panel Glazing: Triple IGU; 1-7/16 inch (36 mm) thick.
          ** NOTE TO SPECIFIER ** Specify with Low Profile Saddle Sills for resistance against wind driven rain. Weeps are to be drilled in the field by the installer to manufacturer's requirements. It is expected that the installed system's performance would be not more than 2/3rds of the following certified laboratory test data in accordance with AAMA 502. Flush Sills, Surface Mounted Interior Sills, and Floor Sockets without a Sill have no rating against wind driven rain. Delete aluminum thresholds options not required.
          14.Aluminum Thresholds: Standards flush sill. Thermally broken with polyamide. Clear anodized.
          15.Aluminum Thresholds: Standards flush sill. Thermally broken with polyamide. Dark bronze anodized.
          16.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Clear anodized.
          17.Aluminum Thresholds: Low profile saddle sill. Thermally broken with polyamide. Dark bronze anodized.
          18.Aluminum Thresholds: Surface mounted interior sill. Clear anodized.
          19.Aluminum Thresholds: Surface mounted interior sill. Dark bronze anodized.
          20.Aluminum Thresholds: No sill, units with adjustable floor sockets.
          ** NOTE TO SPECIFIER ** The performance criteria paragraph applies to Aluminum thresholds/low profile saddle sills only. Delete if not required. Weeps, when required, are field drilled by the installer to manufacturer's requirements. It is expected that the installed system's performance would be not more than 2/3rds of the following certified laboratory test data in accordance with AAMA 502.
          21.Performance Criteria (Lab Tested): Low Profile Saddle Sill.
          a.Air Infiltration with Incorporated Swing Panels (ASTM E283): 0.3 cu ft per min per sq ft (1.5 L per sec per sq m) at a static air pressure difference of 1.57 psf (75 Pa).
          b.Water Penetration (ASTM E331, ASTM E547): No uncontrolled water leakage at a static test pressure in:
          1)Units with weep holes from Middle Channel: 2.92 psf (140 Pa).
          2)Units with weep holes from Inner Channel: 6.0 psf (290 Pa).
          c.Structural Loading (ASTM E330): Pass.
          1)Load Structure: At 1.5 times design wind pressure with no glass breakage or permanent damage to fasteners or storefront components:
          a)Design Pressure Positive: 45 psf (2160 Pa).
          b)Design Pressure Negative: 45 psf (2160 Pa).
          d.Forced Entry (ASTM F842): Meets Type A, Grade 40.
          ** NOTE TO SPECIFIER ** In swing and outswing systems are approved by the State of Florida. FL 25540.1.
          e.Florida Product Approval; Wind Loading: Units with panel sizes up to 43 inch (1.07 m) wide x 120 inch (3.05 m) high subject to manufacturer size chart: FL 25540.1.
          f.Swing Panel; Operation and Cycling Performance (AAMA 920): 500,000 cycles.
          g.Sliding Glass Storefront Units tested to AAMA/WDMA/CSA 101/I.S.2/A440.
          22.Unit Operation: Adjustable sliding and swing hardware with top and bottom track.
          ** NOTE TO SPECIFIER ** Delete panel lite/mullion configuration options not required. Panels over 120 inches high require an intermediate horizontal mullion.
          23.Panel Lite/Mullion Configuration: Standard single lite.
          24.Panel Lite/Mullion Configuration: Horizontal mullions at specified heights from the bottom of the panel as shown on the Drawings.
          25.Panel Lite/Mullion Configuration: Simulated divided lites in pattern as shown on the Drawings.
          ** NOTE TO SPECIFIER ** See manufacturer Drawings for selected custom dimensions within maximum frame sizes possible as indicated in manufacturer's literature. See Drawings for selected number of panels and configuration. Delete panel configuration options not required.
          26.Panel Configuration: Straight.
          27.Panel Configuration: Segmented curve.
          28.Panel Configuration: 90 degree angle turn.
          29.Panel Configuration: 135 degree angle turn.
          30.Panel Configuration: Window/door combination.
          ** NOTE TO SPECIFIER ** Delete stack storage configuration options not required.
          31.Stack Storage Configuration: Remote pocket.
          32.Stack Storage Configuration: Jamb wall.
          33.Stack Storage Configuration: Behind swing door.
          34.Stack Storage Configuration: Straight wall.
          35.Stack Storage Configuration: Jamb wall pockets.
          36.Aluminum Extrusion: AIMgSi0.5 alloy, 6063-T5 (F-22 - European standard).
          a.Thickness: 0.078 inch (2.0 mm) nominal.
          ** NOTE TO SPECIFIER ** Delete aluminum finish options not required. Refer to manufacturer's literature for powder coat colors available.
          37.Aluminum Finish: Anodizing per AAMA 611.
          ** NOTE TO SPECIFIER ** Delete option not required.
          a.Interior: Dark bronze anodized.
          b.Interior: Clear anodized.
          c.Exterior: Dark bronze anodized.
          d.Exterior: Clear anodized.
          **NOTE TO SPECIFIER ** If choosing powder coat finish, delete one of the two options not required; either the AAMA 2604 option or the AAMA 2605 option. Delete both if not specifying a powder coat finish.
Dual color options are only available with powder coated finishes.
          38.Aluminum Finish: Powder Coating per AAMA 2604.
          ** NOTE TO SPECIFIER ** Interior options below apply to powder coating. Delete interior aluminum finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selection.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: Wood grain, standard pattern as selected.
          e.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Exterior options below apply to powder coating Delete exterior aluminum finish options not required.
          f.Exterior: Match interior finish specified.
          g.Exterior: Color as selected from manufacturer's 50 standard color selection.
          h.Exterior: RAL high gloss finish, standard color as selected.
          i.Exterior: RAL matte finish, standard color as selected.
          j.Exterior: Wood grain, standard pattern as selected.
          k.Exterior: Custom finish as selected by the Architect.
          39.Aluminum Finish: Powder Coating per AAMA 2605.
          ** NOTE TO SPECIFIER ** Interior options below apply to powder coating. Delete interior aluminum finish options not required.
          a.Interior: Color as selected from manufacturer's 50 standard color selection.
          b.Interior: RAL high gloss finish, standard color as selected.
          c.Interior: RAL matte finish, standard color as selected.
          d.Interior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Exterior options below apply to powder coating. Delete exterior aluminum finish options not required.
          e.Exterior: Match interior finish specified.
          f.Exterior: Color as selected from manufacturer's 50 standard color selection.
          g.Exterior: RAL high gloss finish, standard color as selected.
          h.Exterior: RAL matte finish, standard color as selected.
          i.Exterior: Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Delete hinge option not required.
          40.Hinges: Manufacturer's standard clear anodized aluminum hinges. Stainless steel hinge pins.
          41.Hinges: Manufacturer's dark bronze anodized aluminum hinges. Stainless steel hinge pins.
          42.Machine screws for connecting frame components.
          43.Adjustment: System capable of specified amount of adjustments without removing panels from tracks.
          44.Sliding Door Hardware:
          ** NOTE TO SPECIFIER ** Delete locking type not required.
          a.Locking: Standard profile cylinder. Finish to match locking hardware and handles.
          ** NOTE TO SPECIFIER ** Delete keying option not required.
          1)Keying: For applications with multiple units, all keyed alike.
          2)Keying: For applications with multiple units, all keyed independently.
          b.Locking: Adapter for small format interchangeable core (SFIC); core furnished by others. Finish to match locking hardware and handles.
          ** NOTE TO SPECIFIER ** Delete handles option not required.
          c.Handles: Stainless steel levers and flat handles in a titanium black finish.
          d.Handles: Stainless steel levers and flat handles in a brushed satin finish.
          ** NOTE TO SPECIFIER ** Delete locking hardware and handles, main entry panel options not required. Note that other compatible lever handle styles and finishes are available from other suppliers.
          e.Locking Hardware and Handles:
          1)Main Entry Panels for Models with a Swing Panel: Manufacturer's standard lever handles on inside and outside.
          a)Primary Panel Hardware: Standard lockset with lockable latch. Multi-point locking with concealed dead bolt and rods at top and bottom on primary panel.
          1)Depression of handles withdraws latch.
          2)Lifting of handles engages rods.
          3)Key or thumb turn engages deadbolt and operates lock.
          b)Manufacturer's push-pull handles, separate lockset, dead bolt and door closer.
          c)No hardware or locking provided by manufacturer; Field installed panic device by Section 08 71 00 - Door Hardware0.
          2)Main Entry Panels, on Sliding Panel to be Opened First for Models Without a Swing Panel:
          a)Manufacturer's standard L-shaped handle on the inside, flat handle on the outside and lockset with profile cylinder.
          1)Key turn from the outside and thumb turn from the inside with two point locking hardware operated by 180 degree turn of the handle.
          b)Manufacturer's standard flat handle on the inside and outside. Lockset with profile cylinder.
          ** NOTE TO SPECIFIER ** Key operation from the inside may not meet egress requirements. Note that with the following options, the main entry panel is operable from inside only and that there is no latch. Delete if not required.
          1)Key from outside and inside with two point locking hardware operated by 180 degree turn of the handle.
          3)Main Entry Panels for Models with a Main Entry Panel:
          a)Manufacturer's standard flat handle on inside only with concealed two point locking hardware operated by 180 degree turn of handle.
          f.Aluminum Locking Rods:
          1)Rod Stroke: 15/16 inch (24 mm).
          2)End Caps: Fiberglass reinforced to meeting structural loading requirements of application. On top and bottom.
          ** NOTE TO SPECIFIER ** Delete locking hardware and handles, secondary panels option not required.
          g.Locking Hardware and Handles, Secondary Panels: On all other secondary panels; flat handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolt locking will not be allowed.
          h.Locking Hardware and Handles, Secondary Panels: On all other secondary panels; removable custodial handles and concealed two-point locking hardware operated by 180 degree turn of handle.
          1)Face applied flush bolt locking will not be allowed.
          i.Handle Height: 41-3/8 inches (1050 mm) centered from bottom of panel or as otherwise indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.5INTERIOR ALL-GLASS WINDOW WALL SYSTEMS.
 
          A.Basis of Design: Model HSW75. Top-hung, single track sliding system with no vertical profiles as manufactured by Nana Wall Systems, Incorporated.
          1.Performance Requirements:
          a.Structural Load Deflection per ASTM E330:
          1)Positive Design Pressure: 30 psf (1436 Pa).
          2)Negative Design Pressure: 30 psf (1436 Pa).
          b.Forced Entry Resistance per AAMA 1304: Pass.
          c.Manufacturer must have a quality system registration per ISO 9001: 2015.
          d.Manufacturer must have an environmental management system registration per ISO 14001: 2015.
          2.Release System: 2-in-1, allowing a selected sliding panel to convert into a single and double action panel or vice versa.
          3.Frame and Panels: Manufacturer's standard top and bottom channel frame and panel profiles, with head track, stacking bays, side jambs, sliding swing panels.
          a.Dimensions as shown on Drawings.
          b.Panels: Single lite.
          c.Mounting Type: Top-hung.
          4.Unit Operation: Sliding with single and double action door type.
          5.Sizes and Configurations: As indicated on Drawings for selected number and size of panels, and location of swing panels.
          ** NOTE TO SPECIFIER ** Delete panel size options not required.
Sliding Panel Sizes (W x H): Up to 49 x 126 inch (1245 x 3200 mm).
Sliding Single and Double Action Panel Sizes (W x H): Up to 39 x 126 inch (1000 x 3200 mm).
Non-Sliding Single and Double Action Panel Sizes (W x H): Up to 43 x 126 inch (1092 x 3200 mm).
          a.Panel Size for Sliding Panels: As indicated on the Drawings.
          b.Panel Size for Sliding Single and Double Action Panels: As indicated on the Drawings.
          c.Panel Size for Non-Sliding Single and Double Action Panels: As indicated on the Drawings.
          ** NOTE TO SPECIFIER ** Delete panel configuration options not required.
          d.Panel Configuration: Straight.
          e.Panel Configuration: Segmented curve.
          f.Panel Configuration: True curve.
          g.Panel Configuration: 90 degree angle turn/ open corner.
          h.Panel Configuration: 135 degree angle turn.
          i.Panel Configuration: Window and door combination.
          ** NOTE TO SPECIFIER ** Delete stack storage configuration options not required.
          j.Stack Storage Configuration: Perpendicular to wall.
          k.Stack Storage Configuration: Parallel to wall.
          l.Stack Storage Configuration: Remote.
          m.Stack Storage Configuration: Pocket wall.
          6.Sill Type: Floor sockets with No floor track.
          7.Head Track (W x D): 2-7/8 x 2-3/4 inches (73 x 70 mm).
          8.Top and Bottom Rail Depth: 1-7/16 inches (36 mm).
          ** NOTE TO SPECIFIER ** Delete top rail width options not required. The first option is standard.
          9.Top Rail Width: 3-15/16 (100 mm).
          10.Top Rail Width: 5-1/4 inches (133 mm).
          11.Top Rail Width: 7-13/16 inches (198 mm).
          12.Top Rail Width: 10 inches (254 mm).
          ** NOTE TO SPECIFIER ** Custom top rail widths are available in 3/16 inch (5 mm) increments from 5-1/4 inch (133 mm) to 7-13/16 inch (198 mm).
          13.Top Rail Width (in/mm): ______.
          ** NOTE TO SPECIFIER ** Delete bottom rail width options not required. The first option below is standard.
          14.Bottom Rail Width: 3-15/16 (100 mm).
          15.Bottom Rail Width: ADA, chamfered door bottom rail, 4-5/8 inch (117 mm).
          16.Bottom Rail Width: 5-1/4 inch (133 mm).
          17.Bottom Rail Width: 7-13/16 inch (198 mm).
          18.Bottom Rail Width: ADA, 10 inch (254 mm) kick plate.
          19.Rail End Cap: Smooth with bumpers on one panel end mitered at corner panels.
          20.Rail Edges: Flat mitered at corner panels.
          21.Aluminum Extrusions: AIMgSi0.5 alloy, 6063-T5 (F-22 - European standard).
          a.Thickness: 0.078 inch (2.0 mm) nominal.
          22.Finish: Aluminum head track, hinges/pivot points and face of top and bottom rails.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          a.Finish: Anodized per AAMA 611. Clear.
          b.Finish: Anodized per AAMA 611. Dark bronze.
          c.Finish: Anodized per AAMA 611. Black.
          d.Finish: Anodized per AAMA 611. Brushed.
          e.Finish: Powder coat per AAMA 2604. Color as chosen from manufacturer's full RAL selection.
          ** NOTE TO SPECIFIER ** Delete option not required.
          1)High gloss.
          2)Matte.
          f.Finish: Powder Coat per AAMA 2604. Custom finish as selected by the Architect.
          ** NOTE TO SPECIFIER ** Specify post assembly clear coat for greater corrosion resistance.
          g.Post assembly clear coated.
          h.Metal Clad Aluminum Finish on Face of Top and Bottom Rails:
          ** NOTE TO SPECIFIER ** Delete metal and finish for cladding not required.
          1)Brushed stainless steel.
          2)Polished stainless steel.
          3)Polished brass.
          4)Satin brass.
          23.Hardware:
          a.Performance Criteria (Lab Tested):
          ** NOTE TO SPECIFIER ** Forced entry testing results are only applicable for the test unit type of locking. See manufacturer's latest published data regarding performance.
          1)Forced Entry (DIN EN 1191): Pass.
          2)Single/Double Action Panels with Pivot Points Operation and Cycling Performance (DIN EN ISO 12400): 100,000 cycles.
          ** NOTE TO SPECIFIER ** Refer to manufacturer's literature for hardware options.
          b.Carrier Hardware: Manufacturer's standard.
          c.Hinge Hardware: Manufacturer's standard.
          d.Locking Hardware: As available from manufacturer and selected by Architect.
          e.Handles: As available from manufacturer and selected by Architect.
          f.Push/Pull Handles, Knobs, Rosettes, or Panic Devices: As available from manufacturer and selected by Architect.
          24.Glass and Glazing:
          ** NOTE TO SPECIFIER ** Delete glazing thickness options not required.
          a.Glass Thickness: 1/2 inch (12 mm).
          b.Glass Thickness: 3/8 inch (10 mm).
          c.Glass Thickness: 9/16 inch (15 mm).
          d.Glass Thickness: 3/4 inch (19 mm).
          e.Glass Thickness: 13/16 inch (21 mm).
          f.Glass Thickness: 1 inch (25 mm).
          ** NOTE TO SPECIFIER ** Contact Nana Wall for availability of many other commercial glass and glazing types. Delete glass type option not required.
          g.Glass Type: Tempered.
          h.Glass Type: Laminated.
          25.Other Components:
          a.Edge Seals: Sealing brush for outside of top rail.
          ** NOTE TO SPECIFIER ** Bumpers prevent metal-to-metal or glass-to-glass contact.
          b.Bumpers: Recessed soft polyamide bumpers on one end of sliding panel end caps at the top and bottom.
          ** NOTE TO SPECIFIER ** Gaskets help reduce glass-to-glass contact, sound transmission, and airflow.
          c.Gaskets between Panels: Clear UV resistant edge mounted gaskets.
          ** NOTE TO SPECIFIER ** Delete accessories not required.
 
          2.6ACCESSORIES
          ** NOTE TO SPECIFIER ** Screen ONE XL is 'non-pleated' while Screen Classic is 'pleated.' Select 'ONE' or 'Classic' deleting option not chosen.
 
          A.Insect Screen Panels: Fully retractable non-pleated screen made of ultra-strong, UV resistant fiberglass mesh housed in a single cartridge riding on a single track.
          1.Basis of Design Product by Manufacturer: Screen ONE XL or an Architect acceptable equivalent subject to project requirements.
          2.Finish - Aluminum Top Track, Side Jambs and Vertical Struts:
          ** NOTE TO SPECIFIER ** Finish options are standard. Check with Nana Wall regarding other available finishes, which may require an upcharge.
          a.Powder Coating: White.
          b.Powder Coating: Black.
          c.Powder Coating: ________.
 
          B.Insect Screen Panels: A series of top-hung collapsible pleated UV resistant fiberglass mesh screen panels riding on a single narrow ADA compliant 1/4 inch (6 mm) floor track. Each 4 inch (102 mm) wide vertical cassette can expand to 39 inches (1000 mm) wide.
          1.Basis of Design Product by Manufacturer: Screen Classic or an Architect acceptable equivalent subject to project requirements.
          2.Finish - Aluminum Top Track, Side Jambs and Vertical Struts:
          ** NOTE TO SPECIFIER ** Options are standard. Check with Nana Wall regarding powder coated and other available finishes, which may require an upcharge.
          a.White powder coated.
          b.Clear anodized.
          c.Dark bronze anodized.
          d.Powder coated with color as selected by architect.
 
          C.Screen Track Stacking: Within opening or extended beyond opening as indicated or required.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Because of the large dimensions involved and the weight and movement of the panels, verify the structural integrity of the header such that the maximum deflection with both the live and dead loads is limited to be the lesser of L/720 of the span and 1/4 inches (6 mm). Provide structural support for lateral loads, and both wind load and eccentric load when the panels are stacked open.
 
          B.Examine surfaces of openings and verify dimensions. Verify rough openings are level, plumb, and square, with no unevenness, bowing, or bumps on floor. Do not begin installation until openings have been properly prepared.
 
          3.2PREPARATION
 
          A.Prepare openings using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
          3.3INSTALLATION
 
          A.Install frame in accordance with manufacturer's recommendations and installation instructions. Properly flash and waterproof around the perimeter of the opening.
 
          B.Securely attach anchorage devices to rigidly fit frame in place, level, straight, plumb and square. Install frame in proper elevation, plane and location, and in proper alignment with other work.
 
          C.When lower track is designed to drain, provide connections to allow for drainage.
 
          D.Install panels, handles, lockset and accessories in accordance with manufacturer's recommendations and instructions.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          E.Finishing: Field finish under Section 09 90 00 - Painting and Coating.
          ** NOTE TO SPECIFIER ** Delete if not required.
 
          F.Accessories: Screens; install in accordance with screen manufacturer's recommendations and installation instructions.
 
          3.4CLEANING AND PROTECTION
 
          A.Protect installed products until completion of project.
 
          B.Remove protective coatings and use manufacturer recommended methods to clean exposed surfaces.
 
         
END OF SECTION