MasterFormat: 2014
SpecWizard: customize this spec    Download this Paints and Coatings Specification for   WORD | WP | RTF | TEXT
Find over 500 more construction specifications | Arcat.com
         
PPG Architectural Finishes, Incorporated - PPG Paints Paints and Coatings
 
         
SECTION 09900
 
         
PAINTS AND COATINGS
 
         
Copyright 2004 - 2019 ARCAT, Inc. - All rights reserved

          ** NOTE TO SPECIFIER ** PPG Architectural Finishes, Incorporated - PPG Paints; commercial and high performance coatings.
This section is based on the products of PPG Architectural Finishes, Incorporated. PPG Paints, which is located at:
400 Bertha Lamme Drive
Cranberry Township, PA 16066
Toll Free Tel: 888-PPG-IDEA
Fax: 888-434-3127
Email: request info (brian.joyce@ppg.com)
Web: www.ppgpaints.com
[ Click Here ] for additional information.

A tradition was established early with PPG - use the best technology, manufacture the best quality products and provide exceptional, dedicated service. Today, that steadfast commitment to excellence is evident in every aspect of our business. We offer solutions for architects,specifiers, paint dealers and contractors in all markets... commercial, industrial and residential.Today, PPG Paints and PPG Protective and Marine Coatings continue the foremost tradition of supplying high quality, comprehensive products lines, leading edge technologies and tailored support programs for each market segment.

Global Resources
PPG Paints and PPG Protective and Marine Coatings are from a global leader in coatings technology and a leading supplier to the building products industry. With over 100 years experience and R&D capabilities second to none, you can be sure we're bringing you the latest product advancements.

One of the Industry's Most Comprehensive Product Lines
Specially formulated to meet the requirements for each market, PPG Paints and PPG Protective and Marine Coatings offer a product for every application.

Commercial:
Building on a long heritage of quality and performance, we continue to update our commercial product line to meet all current specifications, as well as current and proposed environmental regulations. Count on PPG Paints for the products you need to meet the most demanding commercial applications.

Industrial:
PPG offers a complete line of protective and marine coatings for the most demanding environments. From epoxies and urethanes to polysiloxanes, PPG Protective & Marine coatings provide outstanding products and service to meet your needs.Institutional:Introducing a new low-odor, zero VOC PPG Paints product, Pure Performance, that offers excellent durability, washability, and touch-up. Ideal for schools, hotels, hospitals, office buildings, government offices, retail space - any space where job-site disruption is a concern and a top-performing, zero VOC product is needed.

Residential:
Exterior paints that stand up to the elements and still look great. Interior paints thatreflect the perfect mood and style. Wood stains and clears for decks and siding. Primers that start the job off right. No matter what the need, PPG Paints has the complete product line for today's residential applications.

See our SpecWizard: Click Here

 
          PART 1GENERAL
 
          1.1SECTION INCLUDES
          ** NOTE TO SPECIFIER ** Delete items below not required for project.
 
          A.Exterior Paint Systems: Surface preparation and field painting of exposed exterior items and surfaces.
 
          B.Exterior stain and natural finish woodwork systems.
 
          C.Interior Paint Systems: Surface preparation and field painting of exposed interior items and surfaces.
 
          D.Interior stain and natural finish woodwork systems.
 
          E.Exterior High Performance Coating Systems: Surface preparation and field application of exterior high-performance coating systems to items and surfaces scheduled.
 
          F.Interior High Performance Coating Systems: Surface preparation and field application of interior high-performance coating systems to items and surfaces scheduled.
 
          1.2RELATED SECTIONS
          ** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.
 
          A.Section 03 30 00 - Cast-in-Place Concrete.
 
          B.Section 05 12 13 - Architecturally-Exposed Structural Steel Framing.
 
          C.Section 05 50 00 - Metal Fabrications.
 
          D.Section 06 20 00 - Finish Carpentry.
 
          E.Section 08 11 13.13 - Standard Hollow Metal Doors and Frames.
 
          F.Section 09 21 16.33 - Gypsum Board Area Separation Wall Assemblies.
 
          G.Section 22 05 00 - Common Work Results for Plumbing.
 
          H.Section 26 05 00 - Common Work Results for Electrical.
 
          1.3REFERENCES
          ** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
 
          A.American Society for Testing and Materials (ASTM) D 16 - Standard Terminology for Paint, Related Coatings, Materials, and Applications.
 
          B.Steel Structures Painting Council (SSPC) SP6 - Commercial Blast Cleaning Procedures.
 
          C.Steel Structures Painting Council (SSPC) SP10 - Near White Blast Cleaning Procedure.
 
          1.4DEFINITIONS
 
          A.General: Standard coating terms defined in ASTM D 16.
          1.Flat: lusterless or matte. Gloss Range: Max 15 measured at 85 degree meter.
          2.Eggshell: Low-sheen. Gloss Range: 20 to 35 measured at 60 degree meter.
          3.Semi-Gloss: Medium-sheen. Gloss Range: 35 to 70 measured at 60 degree meter.
          4.Full Gloss: High-sheen. Gloss Range: Above 70 measured at a 60 degree meter.
 
          B.Environments: The following terms distinguish between different corrosive exposures:
          1.Severe Environments: Highly corrosive industrial atmospheres. Sustained exposure to high humidity and condensation and with frequent cleaning using strong chemicals. Environments with heavy concentrations of strong chemical fumes and frequent splashing and spilling of harsh chemical products are severe environments.
          2.Moderate Environments: Corrosive industrial atmospheres with intermittent exposure to high humidity and condensation, occasional mold and mildew development, and regular cleaning with strong chemicals. Environments with exposure to heavy concentrations of chemical fumes and occasional splashing and spilling of chemical products are moderate environments.
          3.Mild Environment: industrial atmospheres with normal exposure to moderate humidity and condensation, occasional mold and mildew development, and infrequent cleaning with strong chemicals. Environments with low levels of mild chemical fumes and occasional splashing and spilling of chemical products are mild environments. Normal outdoor weathering is also considered a mild environment.
 
          1.5SUBMITTALS
 
          A.Submit under provisions of Section 01 30 00 - Administrative Requirements.
 
          B.Product Data: For each paint system indicated, including:
          1.Material List: An inclusive list of required coating materials. Indicate each material and cross reference specific coating, finish system, and application. Identify each material by manufacturer's catalog number and general classification.
          2.Preparation instructions and recommendations.
          3.Manufacturer's Information: Manufacturer's technical information, including label analysis and instructions for handling, storing, and applying each coating material.
          ** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
 
          C.Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
 
          D.Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
 
          1.6QUALITY ASSURANCE
 
          A.Installer Qualifications: A firm or individual experienced in applying paints and coatings similar in material, design, and extent to those indicated for this Project, whose work has resulted in applications with a record of successful in-service performance.
 
          B.Obtain block fillers and primers for each coating system from the same manufacturer as the finish coats.
 
          C.Paint exposed surfaces. If an item or a surface is not specifically mentioned, paint the item or surface the same as similar adjacent materials or surfaces. If a color of finish is not indicated, Architect will select from standard colors and finishes available.
 
          D.Do not paint prefinished items, concealed surfaces, finished metal surfaces, operating parts, and labels.
          ** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
 
          E.Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
          1.Finish areas designated by Architect.
          2.Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.
          3.Refinish mock-up area as required to produce acceptable work.
 
          1.7DELIVERY, STORAGE, AND HANDLING
 
          A.Deliver materials to Project site in manufacturer's original, unopened packages and containers bearing manufacturer's name and label:
 
          B.Store materials not in use in tightly covered containers in a well-ventilated area at a minimum ambient temperature of 45 deg F (7 deg C). Maintain storage containers in a clean condition, free of foreign materials and residue.
 
          1.8PROJECT CONDITIONS
 
          A.Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
 
          B.Apply waterborne paints only when temperatures of surfaces to be painted and surrounding air are between 50 and 90 deg F (10 and 32 deg C).
 
          C.Apply solvent-thinned paints only when temperatures of surfaces to be painted and surrounding air are between 45 and 95 deg F (7 and 35 deg C).
 
          D.Do not apply paint in snow, rain, fog, or mist: or when relative humidity exceeds 85 percent: or at temperatures less than 5 deg F (3 deg C) above the dew point: or to damp or wet surfaces.
          1.Painting may continue during inclement weather if surfaces and areas to be painted are enclosed and heated within temperature limits specified by manufacturer during application and drying periods.
          ** NOTE TO SPECIFIER ** Extra materials may not be allowed for publicly funded projects. Do not include for High Performance Coatings (HPC). Delete if not required.
 
          1.9EXTRA MATERIALS
 
          A.Furnish extra paint materials from the same production run as the materials applied and in the quantities described below. Package with protective covering for storage and identify with labels describing contents. Deliver extra materials to Owner.
 
          B.Quantity: Furnish Owner with an additional three percent, but not less than 1 gal (3.8 l) or 1 case, as appropriate, of each material and color applied.
 
          PART 2PRODUCTS
 
          2.1MANUFACTURERS
 
          A.Acceptable Manufacturer: PPG Architectural Finishes, Incorporated - PPG Paints, which is located at: 400 Bertha Lamme Dr.; Cranberry Township, PA 16066; Toll Free Tel: 888-PPG-IDEA; Fax: 888-434-3127; Email: request info; Web: https://www.ppgpaints.com
          1.Basis of Design: PPG Paints as manufactured and supplied by PPG Architectural Finishes, Incorporated.
          ** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
 
          B.Substitutions: Not permitted.
 
          C.Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
 
          2.2PAINT MATERIALS - GENERAL
 
          A.Material Compatibility: Provide block fillers, primers, and finish-coat materials that are compatible with one another and with the substrates indicated under conditions of service and application, as demonstrated by manufacturer based on testing and field experience.
          ** NOTE TO SPECIFIER ** Revise VOC rating to suit local regulations or Owner's requirements. Delete if not required.
 
          B.VOC Classification: Provide high-performance coating materials, including primers, undercoats, and finish-coat materials, that meet the applicable local, state or federal VOC requirements.
 
          C.Color: Refer to Finish Schedule and Paint Legend for paint colors.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.3EXTERIOR PAINT SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required.
 
          A.Concrete, Stucco, and Masonry (Other Than Concrete Masonry Units): Provide the following finish systems over exterior concrete, stucco, and brick masonry substrates.
          1.Acrylic Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 4-603XI PERMA-CRETE Interior/Exterior Alkali Resistant Primer. Applied Dry Film Thickness: 1.4 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          d.Exterior High Build Flat Acrylic Finish: PPG Paints. 4-22XI Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.2 mils min.
          e.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min.
          f.Exterior High Build Satin Acrylic Finish: PPG Paints. 4-422 Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.0 mils min.
          g.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          h.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          i.Exterior Acrylic Texture Finish: PPG Paints. 4-50 Series Perma-Crete 100 Percent Acrylic Texture Coating. Applied Dry Film Thickness: 6.8 mils min.
          j.Exterior Elastomeric Coating: PPG Paints. 4-110XI Series Perma-Crete Pitt-Flex Elastomeric Coating. Applied Dry Film Thickness: 5.4 mils min.
 
          B.Concrete Masonry Unit: Provide the following finish systems over exterior concrete masonry units.
          1.Acrylic Finish: Two finish coats over a block filler.
          a.Block Filler: PPG Paints. 6-15XI Speedhide Interior/Exterior Acrylic Masonry Block Filler. Applied Dry Film Thickness: 8.0 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          b.Exterior Flat Acrylic Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          c.Exterior High Build Flat Acrylic Finish: PPG Paints. 4-22XI Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.2 mils min.
          d.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min.
          e.Exterior High Build Satin Acrylic Finish: PPG Paints. 4-422 Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.0 mils min.
          f.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min .
          g.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          h.Exterior Acrylic Texture Finish: PPG Paints. 4-50 Series Perma-Crete 100 Percent Acrylic Texture Coating. Applied Dry Film Thickness: 6.8 mils min.
          i.Exterior Elastomeric Coating: PPG Paints. 4-110XI Series Perma-Crete Pitt-Flex Elastomeric Coating. Applied Dry Film Thickness: 5.4 mils min.
 
          C.Mineral-Fiber-Reinforced Cement Panels: Provide the following finish systems over exterior, mineral-fiber-reinforced cement panels.
          1.Acrylic Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 4-603XI Perma-Crete Interior/Exterior Alkali Resistant Primer. Applied Dry Film Thickness: 1.4 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: Not less than 1.3 mils.
          d.Exterior High Build Flat Acrylic Finish: PPG Paints. 4-22XI Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.2 mils min.
          e.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min .
          f.Exterior High Build Satin Acrylic Finish: PPG Paints. 4-422 Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.0 mils min.
          g.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          h.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          i.Exterior Acrylic Texture Finish: PPG Paints. 4-50 Series Perma-Crete 100 Percent Acrylic Texture Coating. Applied Dry Film Thickness: 6.8 mils min.
          j.Exterior Elastomeric Coating: PPG Paints. 4-110XI Series Perma-Crete Pitt-Flex Elastomeric Coating. Applied Dry Film Thickness: 5.4 mils min.
 
          D.Exterior Gypsum Soffit Board: Provide the following finish systems over exterior gypsum soffit board.
          1.Acrylic Finish: Two finish coats over an alkali-resistant primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 4-603XI Perma-Crete Interior/Exterior Alkali Resistant Primer. Applied Dry Film Thickness: 1.4 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          d.Exterior High Build Flat Acrylic Finish: PPG Paints. 4-22XI Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.2 mils min.
          e.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min.
          f.Exterior High Build Satin Acrylic Finish: PPG Paints. 4-422 Series Perma-Crete High Build 100 Percent Acrylic Topcoat. Applied Dry Film Thickness: 3.0 mils min.
          g.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          h.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          i.Exterior Acrylic Texture Finish: PPG Paints. 4-50 Series Perma-Crete 100 Percent Acrylic Texture Coating. Applied Dry Film Thickness: 6.8 mils min.
 
          E.Smooth Wood: Provide the following finish systems over smooth wood siding, wood trim, and other smooth exterior wood surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 17-941NF Seal Grip Interior/Exterior Alkyd Primer. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          d.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mils min.
          e.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          f.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          g.Exterior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          F.Wood Trim: Provide the following finish systems over exterior wood trim.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness. 1.6 mils min.
          b.Primer: PPG Paints. 17-941NF Seal Grip Interior/Exterior Alkyd Primer. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Paint Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          d.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mils min.
          e.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          f.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          g.Exterior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          G.Plywood: Provide the following finish systems over exterior plywood.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 17-941NF Seal Grip Interior/Exterior Alkyd Primer. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Exterior Flat Acrylic Paint Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          d.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mils min.
          e.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          f.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          g.Exterior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          H.Ferrous Metal: Provide the following finish systems over exterior ferrous metal. Primer is not required on shop-primed items.
          1.Acrylic or Alkyd Finish: Two finish coats over a rust-inhibitive primer.
          a.Primer required for items not shop-primed.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          b.Primer/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          c.Primer: PPG Paints. 6-208 Series Speedhide Alkyd Metal Primer. Applied Dry Film Thickness: 2.3 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          d.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mils min.
          e.Exterior Satin Acrylic Enamel Finish: PPG Paints. 90-1110 Series Pitt-Tech Plus Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          f.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          g.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          h.Exterior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 4336H Series HPC Urethane Alkyd Semi-Gloss Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          i.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          j.Exterior Full-Gloss Alkyd Enamel Finish: PPG Paints. 7-282 Series 7-Line Industrial Gloss-Oil Interior/Exterior Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
 
          I.Zinc-Coated Metal: Provide the following finish systems over exterior zinc-coated metal surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a galvanized metal primer.
          a.Primer/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          b.Exterior Eggshell Acrylic Paint Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min.
          c.Exterior Satin Acrylic Enamel Finish: PPG Paints. 90-1110 Series Pitt-Tech Plus Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          d.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          e.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          f.Exterior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 4336H Series HPC Urethane Alkyd Semi-Gloss Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          g.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          h.Exterior Full-Gloss Alkyd Enamel Finish: PPG Paints. 7-282 Series 7-Line Industrial Gloss-Oil Interior/Exterior Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
 
          J.Aluminum: Provide the following finish systems over exterior aluminum surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          a.Primer/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          b.Exterior Flat Acrylic Paint Finish: PPG Paints. 6-610XI Series Speedhide Exterior House Paint Flat Latex. Applied Dry Film Thickness: 1.3 mils min.
          c.Exterior Eggshell Acrylic Finish: PPG Paints. 6-2045XI Series Speedhide Exterior House and Trim Satin-Acrylic Latex. Applied Dry Film Thickness: 1.0 mil min.
          d.Exterior Satin Acrylic Enamel Finish: PPG Paints. 90-1110 Series Pitt-Tech Plus Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          e.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 6-900XI Series Speedhide Exterior House and Trim Semi-Gloss Acrylic Latex Paint. Applied Dry Film Thickness: 1.5 mils min.
          f.Exterior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          g.Exterior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 4336H Series HPC Urethane Alkyd Semi-Gloss Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          h.Exterior Full-Gloss Acrylic Enamel Finish: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          i.Exterior Full-Gloss Alkyd Enamel Finish: PPG Paints: 7-282 Series 7-Line Industrial Gloss-Oil Interior/Exterior Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.4EXTERIOR STAIN AND NATURAL FINISH WOODWORK SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required.
 
          A.Stained Woodwork: Provide the following stain finishes over new exterior woodwork, for use with both vertical siding/trim and horizontal deck applications unless otherwise stated.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          1.Alkyd-Based Toner Wood Finish: Penetrating sealer/finish system applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coats option not required.
          a.Sealer/Finish Coats: Flood. FLD447 Flood CWF-OIL Penetrating Oil Wood Finish. Apply two coats using a wet-on-wet application. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          b.Sealer/Finish Coat: ProLuxe. SIK240 Series SRD Wood Finish (Transparent Matte). Apply 1 coat. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          c.Sealer/Finish Coat: ProLuxe. SIK250 Series SRD RE Wood Finish (Transparent Matte). Apply 1 coat.
          d.Sealer/Finish Coats: ProLuxe. SIK440 Series Premium Deck Wood Finish (Transparent Satin). Apply two coats. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          2.Alkyd-Based Toner Wood Finish for Vertical Siding/Trim Applications: Penetrating sealer/finish system applied on properly cleaned and prepared vertical wood surface. Not for deck applications.
          ** NOTE TO SPECIFIER ** Delete coating options not required.
          a.Sealer Coat: ProLuxe. SIK410 Series 1 Primary RE Wood Finish (Transparent Matte). Use with SIK430 Series 23 Top Coat RE Wood Finish.
          b.Finish Coats: ProLuxe. SIK430 Series 23 Top Coat RE Wood Finish (Transparent Satin). Apply 2 coats over SIK410 Series 1 Primary RE Wood Finish. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          c.Sealer/Finish Coats: ProLuxe. SIK480 Series Door and Window Wood Finish (Transparent Satin). Apply 3 coats. Not Compliant in SCAQMD.
          d.Sealer/Finish Coats: ProLuxe. SIK420 Series Log and Siding Wood Finish (Transparent Satin). Apply 2 coats. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          e.Clear Coat: ProLuxe. SIK48003 Door and Window Wood Finish (Transparent Satin). Apply over SIK480 Series as needed to maintain sheen. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          f.Clear Maintenance Coat: ProLuxe. SIK61003 Maintenance RE Wood Finish (Clear Satin). Apply over SIK420 or SIK 430 Series as needed to maintain sheen. Vertical applications only. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts.
          3.Acrylic-Oil Toner Wood Finish: Penetrating sealer/finish system applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coat option not required.
          a.Sealer/Finish Coat: Flood. FLD520 Series Flood CWF-UV Penetrating Wood Finish. Apply 1 coat.
          b.Sealer/Finish Coat: Flood. FLD565 Series Flood CWF-UV5 Penetrating Wood Finish. Apply 1 coat.
          4.Alkyd-Based Semi-Transparent Wood Finish: Penetrating sealer/finish systems applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coat options not required.
          a.Sealer/Finish Coat: Flood. FLD802 Series Flood Semi-Transparent Alkyd-Oil Wood Finish. Apply 1 coat. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts.
          5.Acrylic-Oil Semi-Transparent Wood Finish: Penetrating sealer/finish systems applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coat option not required.
          a.Sealer/Finish Coat: Flood. FLD812 Series Flood Semi-Transparent Acrylic-Oil Wood Finish. Apply 1 coat. Not compliant in SCAQMD.
          b.Sealer/Finish Coat: Flood. FLD832 Series Flood Semi-Transparent Acrylic-Oil Wood Finish. Apply 1 coat.
          6.Acrylic Based Semi-Transparent Wood Finish: Penetrating sealer/finish systems applied on properly cleaned and prepared wood surface.
          a.Sealer/Finish Coat: ProLuxe: SIK500 Series SRD Semi-Transparent Wood Finish (Matte). Apply 1 coat.
          7.Alkyd-Oil Semi-Opaque Wood Finish: Penetrating sealer/finish systems applied on properly cleaned and prepared wood surface.
          a.Sealer/Finish Coat: Flood: FLD842 Series Flood Semi-Opaque Alkyd-Oil Wood Finish. Apply 2 coats using a wet-on-wet application. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts.
          8.Acrylic Solid Color Wood Finish: Acrylic topcoat systems applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coats option not required.
          a.Sealer/Finish Coats: Flood. FLD820 Series Flood Acrylic Solid Color Matte Wood Finish. Apply 2 coats.
          b.Sealer/Finish Coats: ProLuxe. SIK710 Series Premium Solid Stain Wood Finish (Matte). Apply 2 coats.
 
          B.Natural Finish Woodwork: Provide the following stained finishes over new exterior woodwork.
          1.Alkyd-Based Varnish Finish: Two finish coats of alkyd based clear varnish over a properly prepared wood surface. Provide wood filler on open-grain wood before applying first varnish coat. Not for deck applications.
          ** NOTE TO SPECIFIER ** Delete paste wood filler coat below for tight grained wood such as birch or poplar. Keep filler coat for Oak and Walnut and similar open-grain woods. Delete finish coats options not required,
          a.Filler Coat: Open-Grain Wood Filler.
          b.Finish Coats: Deft. DFT26 Defthane Polyurethane Interior/Exterior Oil-Based 275 g/L; Satin.
          c.Finish Coats: Deft. DFT123 Defthane Polyurethane Interior/Exterior Oil-Based 275 g/L; Semi-Gloss.
          d.Finish Coats: Deft. DFT21 Defthane Polyurethane Interior/Exterior Oil Based 275 g/L; Gloss.
          ** NOTE TO SPECIFIER ** This finish is a waterborne alternative to solvent-based finishes. Delete if not required.
          2.Waterborne Varnish Finish: Two finish coats of waterborne clear varnish over a properly prepared wood surface. Wipe wood filler before applying stain. Not for deck applications.
          ** NOTE TO SPECIFIER ** Delete paste wood filler coat below for tight-grained wood such as birch or poplar. Keep filler coat for Oak and Walnut and similar open-grain woods. Delete finish coats options if not required.
          a.Filler Coat: Open-Grain Wood Filler.
          b.Finish Coats: Deft: DFT259 Clear Deft Polyurethane Interior/Exterior Water-Based Acrylic Satin.
          c.Finish Coats: Deft: DFT258 Clear Deft Polyurethane Interior/Exterior Water-Based Acrylic Semi-Gloss.
          d.Finish Coats: Deft: DFT257 Clear Deft Polyurethane Interior/Exterior Water-Based Acrylic Gloss.
          3.Clear Penetrating Wood Finish: Penetrating sealer/finish systems applied on properly cleaned and prepared wood surface.
          ** NOTE TO SPECIFIER ** Delete sealer/finish coat options not required.
          a.Sealer/Finish Coats: Flood: FLD540 Flood CWF Multi-Surface Waterproofing Clear Sealant. Apply 2 coats using a wet-on-wet application.
          b.Sealer/Finish Coat: Flood: FLD542 Flood CWF-UV Clear/Natural Penetrating Wood Finish. Apply 1 coat.
          c.Sealer/Finish Coat: Flood: FLD565 Flood CWF-UV5 Clear/Natural Penetrating Wood Finish. Apply 1 coat.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.5INTERIOR PAINT SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required.
 
          A.Concrete and Masonry (Other Than Concrete Unit Masonry): Provide the following paint systems over interior concrete and brick masonry substrates.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 4-603XI Perma-Crete Interior/Exterior Alkali Resistant Primer. Applied Dry Film Thickness: 1.4 mils min.
          c.Primer: PPG Paints. 6-2 Speedhide Interior Quick-Drying Latex Sealer. Applied Dry Film Thickness: 1.0 mils min.
          d.Primer-Zero VOC: PPG Paints. 6-4900XI Speedhide zero Interior Zero VOC Latex Primer. Applied Dry Film Thickness: 1.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          e.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          f.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          g.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          j.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          k.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          l.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          m.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          n.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          o.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          p.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          q.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          r.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          B.Concrete Unit Masonry: Provide the following finish systems over interior concrete masonry.
          1.Acrylic or Alkyd Finish: Two finish coats over a block filler.
          ** NOTE TO SPECIFIER ** A second coat of block filler may be needed over very coarse concrete masonry substrates. Delete block filler options if not required.
          a.Block Filler: PPG Paints. 6-7 Speedhide Interior/Exterior Masonry Latex Block Filler. Applied Dry Film Thickness: 6.0 to 14.0 mils min.
          b.Block Filler: PPG Paints. 6-15XI Speedhide Interior/Exterior Acrylic Masonry Block Filler. Applied Dry Film Thickness: 8.0 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          d.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          e.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          f.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          g.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          i.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          j.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          k.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          l.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          m.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          n.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          o.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          p.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          C.Gypsum Board: Provide the following finish systems over interior gypsum board surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 6-2 Speedhide Interior Quick-Drying Latex Sealer. Applied Dry Film Thickness: 1.0 mils min.
          c.Primer-Zero VOC: PPG Paints. 6-4900XI Speedhide zero Interior Zero VOC Latex Primer. Applied Dry Film Thickness: 1.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          d.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          e.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          f.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          g.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          j.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          k.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          l.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          m.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          n.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          o.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          p.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          q.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          D.Plaster: Provide the following finish systems over new interior plaster surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 6-2 Speedhide Interior Quick-Drying Latex Sealer. Applied Dry Film Thickness: 1.0 mils min.
          c.Primer-Zero VOC: PPG Paints. 6-4900XI Speedhide zero Interior Zero VOC Latex Primer. Applied Dry Film Thickness: 1.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          d.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          e.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          f.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          g.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          j.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          k.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          l.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          m.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          n.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          o.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          p.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          q.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          E.Acoustical Plaster: Provide the following finish system over interior acoustical plaster surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 6-2 Speedhide Interior Quick-Drying Latex Sealer. Applied Dry Film Thickness: 1.0 mils min.
          c.Primer-Zero VOC: PPG Paints. 6-4900XI Speedhide zero Interior Zero VOC Latex Primer. Applied Dry Film Thickness: 1.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          d.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          e.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          f.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          g.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          j.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          k.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          l.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          m.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          n.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          o.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          p.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          q.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          F.Wood and Hardboard: Provide the following paint finish systems over new interior wood surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Choose primer either for acrylics or alkyd topcoats. Delete primer options not required.
          a.Primer for Acrylic-Enamel Finishes: PPG Paints. 17-921XI Series Seal Grip 100 Percent Acrylic Universal Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer: PPG Paints. 6-2 Speedhide Interior Quick-Drying Latex Sealer. Applied Dry Film Thickness: 1.0 mils min.
          c.Primer-Zero VOC: PPG Paints. 6-4900XI Speedhide zero Interior Zero VOC Latex Primer. Applied Dry Film Thickness: 1.2 mils min.
          d.Primer for Alkyd-Enamel Finishes: PPG Paints. 17-941NF Seal Grip Interior/Exterior Alkyd Primer. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          e.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          f.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          g.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Eggshell Water-Based Epoxy Finish: PPG Paints. 16-310 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          j.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          k.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          l.Interior Satin Alkyd Enamel Finish: PPG Paints. 39-10 Series Glyptex Interior Alkyd Enamel Satin. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          m.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          n.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          o.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 439-10 Series Glyptex Interior Alkyd Enamel Semi-Gloss. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          p.Interior Semi-Gloss Water-Based Epoxy Finish: PPG Paints. 16-510 Series Pitt Glaze WB1 Interior Pre-Catalyzed Acrylic Epoxy. Applied Dry Film Thickness: 1.5 mils min.
          q.Interior Full-Gloss Acrylic Enamel Finish: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          r.Interior Full Gloss Alkyd Enamel Low Odor Finish: PPG Paints. 4139-10 Series Glyptex Interior/Exterior Alkyd Gloss Enamel. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts. Applied Dry Film Thickness: 1.8 mils min.
 
          G.Ferrous Metal: Provide the following finish systems over ferrous metal.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Most architectural coatings withstand surface temperatures to approximately 200 deg F (93 deg C) without problems. For hot-water and steam piping systems that are expected to exceed 200 deg F (93 deg C), insert a suitable acrylic or alkyd organic coating or a suitable epoxy coating. Delete primer option not required.
          a.Primer/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          b.Primer: PPG Paints. 6-208 Series Speedhide Alkyd Metal Primer. Applied Dry Film Thickness: 2.3 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          d.Interior Flat Acrylic Finish-Zero VOC: PPG Paints: 6-4110XI Series Speedhide Zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          e.Interior Eggshell Acrylic Enamel Finish: PPG Paints: 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          f.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          g.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          h.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          i.Interior Satin Acrylic Enamel Finish: PPG Paints. 90-1110 Series Pitt-Tech Plus Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          j.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          k.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          l.Interior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          m.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 4336H Series HPC Urethane Alkyd Semi-Gloss Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          n.Interior Gloss Acrylic Enamel Finish: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          o.Interior Full-Gloss Alkyd Enamel Finish: PPG Paints. 7-282 Series 7-Line Industrial Gloss-Oil Interior/Exterior Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          2.Dry Fall Finish: Two finish coats over a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          b.Primer: PPG Paints. 6-208 Series Speedhide Alkyd Metal Primer. Applied Dry Film Thickness: 2.3 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          c.Interior Water-Based Flat Finish: PPG Paints. 6-725XI Series Speedhide Super Tech WB Interior Dry-Fog Flat Latex. Applied Dry Film Thickness: 2.2 mils min.
          d.Interior Water-Based Eggshell: PPG Paints. 6-724XI Speedhide Super Tech WB Interior 100 percent Acrylic Dry-Fog Eggshell Latex. Applied Dry Film Thickness: 2.0 mils min.
          e.Interior Water-Based Semi-Gloss: PPG Paints. 6-727XI Speedhide Super Tech WB Interior 100 percent Acrylic Dry-Fog Semi-Gloss Latex. Applied Dry Film Thickness: 2.2 mils min.
 
          H.Zinc-Coated Metal: Provide the following finish systems over interior zinc-coated metal surfaces.
          1.Acrylic or Alkyd Finish: Two finish coats over a primer.
          a.Prime/Flat Acrylic Finish: PPG Paints. 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          b.Interior Flat Acrylic Finish: PPG Paints. 6-70 Series Speedhide Interior Wall Flat-Latex Paint. Applied Dry Film Thickness: 1.3 mils min.
          c.Interior Flat Acrylic Finish-Zero VOC: PPG Paints. 6-4110XI Series Speedhide zero Interior Zero VOC Flat Latex. Applied Dry Film Thickness: 1.4 mils min.
          d.Interior Eggshell Acrylic Enamel Finish: PPG Paints. 6-411 Series Speedhide Eggshell Acrylic Latex Enamel. Applied Dry Film Thickness: 1.5 mils min.
          e.Interior Eggshell Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4310XI Series Speedhide zero Interior Zero VOC Eggshell Latex. Applied Dry Film Thickness: 1.5 mils min.
          f.Interior Satin Acrylic Enamel Finish: PPG Paints. 6-3511 Series Speedhide Interior Satin Latex. Applied Dry Film Thickness: 1.3 mils min.
          g.Interior Satin Acrylic Enamel Finish-Zero VOC: PPG Paints. 6-4410XI Series Speedhide zero Interior Zero VOC Satin Latex. Applied Dry Film Thickness: 1.5 mils min.
          h.Interior Satin Acrylic Enamel Finish: PPG Paints. 90-1110 Series Pitt-Tech Plus Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          i.Interior Semi-Gloss Acrylic Enamel: PPG Paints. 6-500 Series Speedhide Interior Semi-Gloss Latex. Applied Dry Film Thickness: 1.4 mils min.
          j.Interior Semi-Gloss Acrylic Enamel-Zero VOC: PPG Paints. 6-4510XI Series Speedhide zero Interior Zero VOC Semi-Gloss Latex. Applied Dry Film Thickness: 1.3 mils min.
          k.Interior Semi-Gloss Acrylic Enamel Finish: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          l.Interior Semi-Gloss Alkyd Enamel Finish: PPG Paints. 4336H Series HPC Urethane Alkyd Semi-Gloss Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          m.Interior Gloss Acrylic Enamel Finish: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          n.Interior Full-Gloss Alkyd Enamel Finish: PPG Paints: 7-282 Series 7-Line Industrial Gloss-Oil Interior/Exterior Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          2.Dry Fall Finish: Two finish coats over a primer.
          a.Primer/Flat Acrylic Finish: PPG Paints: 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          b.Interior Water-Based Flat Finish: PPG Paints. 6-725XI Series Speedhide Super Tech WB Interior Dry-Fog Flat Latex. Applied Dry Film Thickness: 2.2 mils min.
          c.Interior Water-Based Eggshell: PPG Paints. 6-724XI Speedhide Super Tech WB Interior 100 percent Acrylic Dry-Fog Eggshell Latex. Applied Dry Film Thickness: 2.0 mils min.
          d.Interior Water-Based Semi-Gloss: PPG Paints. 6-727XI Speedhide Super Tech WB Interior 100 percent Acrylic Dry-Fog Semi-Gloss Latex. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.6INTERIOR STAIN AND NATURAL FINISH WOODWORK SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required.
 
          A.Stained Woodwork: Provide the following stained finishes over new interior woodwork.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          1.Alkyd Varnish Finish over Stain: Two finish coats of alkyd-based clear varnish over a sealer coat and wood stain. Wipe wood filler before applying stain.
          ** NOTE TO SPECIFIER ** Delete paste wood filler coat below for tight-grained wood such as birch or poplar. Keep filler coat for Oak and Walnut and similar open-grain woods. Delete filler coat if not required.
          a.Filler Coat: Open-Grain Wood Filler.
          ** NOTE TO SPECIFIER ** Delete either stain coat or sealer coat paragraph.
          b.Stain Coat: Deft. DFT400 Oil-Based Wood Stain. Not Compliant in SCAQMD.
          c.Sealer Coat: Deft. DFT61 Sanding Sealer Interior Water-Based.
          ** NOTE TO SPECIFIER ** Delete finish coat options not required.
          d.Finish Coats: Deft. DFT129 Polyurethane Interior Oil-Based 350 g/L Satin.
          e.Finish Coats: Deft. DFT128 Polyurethane Interior Oil-Based 350 g/L Semi-Gloss.
          f.Finish Coats: Deft. DFT127 Polyurethane Interior Oil-Based 350 g/L Gloss.
          2.Waterborne Varnish Finish over Stain: Two finish coats of waterborne clear varnish over a sealer coat and wood stain. Wipe wood filler before applying stain.
          ** NOTE TO SPECIFIER ** Delete filler coat below for tight grained wood such as birch or poplar. keep filler coat for Oak and Walnut and similar open-grain woods. Delete filler coat if not required.
          a.Filler Coat: Open-Grain Wood Filler.
          ** NOTE TO SPECIFIER ** Delete either stain coat or sealer coat paragraph.
          b.Stain Coat: Deft. DFT300 Water-Based Wood Stain.
          c.Sealer Coat: Deft. DFT61 Sanding Sealer Interior Water-Based.
          ** NOTE TO SPECIFIER ** Delete finish coat options not required.
          d.Finish Coats: Deft. DFT159 Clear Polyurethane Interior Water-Based Acrylic Satin.
          e.Finish Coats: Deft. DFT158 Clear Polyurethane Interior Water-Based Acrylic Semi-Gloss.
          f.Finish Coats: Deft. DFT157 Clear Polyurethane Interior Water-Based Acrylic Gloss.
          3.Alkyd-Based Stain Wax-Polished Finish: Three finish coats of paste wax over a sealer coat and wood stain. Wipe wood filler before applying stain.
          ** NOTE TO SPECIFIER ** Delete either filler coat or stain coat paragraph.
          a.Filler Coat: Open-Grain Wood Filler.
          b.Stain Coat: Deft: DFT400 Deft Oil-Based Wood Stain. Not Compliant in SCAQMD.
          c.Sealer Coat: Deft: DFT60 Deft Sanding Sealer Interior Oil-Based. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts.
          d.Finish Coats: Paste wax.
          4.Waterborne Stain Wax-Polished Finish: Three finish coats of paste wax over a sealer coat and wood stain. Wipe wood filler before applying stain.
          ** NOTE TO SPECIFIER ** Delete either filler coat or stain coat paragraph.
          a.Filler Coat: Open-Grained Wood Filler.
          b.Stain Coat: Deft: DFT300 Deft Water-Based Wood Stain.
          c.Sealer Coat: Deft: DFT61 Deft Sanding Sealer Interior Water-Based.
          d.Finish Coats: Paste wax.
 
          B.Natural Finish Woodwork: Provide the following natural finishes over new interior woodwork.
          ** NOTE TO SPECIFIER ** Delete finish options not required.
          1.Alkyd-Based Varnish Finish: Two finish coats of alkyd based clear varnish over a sanding sealer. Provide wood filler on open-grain wood before applying first varnish coat.
          a.Filler Coat: Open-Grain Wood Filler.
          b.Sealer Coat: Deft: DFT61 Sanding Sealer Interior Water-Based.
          ** NOTE TO SPECIFIER ** Delete finish coat options not required.
          c.Finish Coats: Deft. DFT129 Deft Polyurethane Interior Oil-Based 350 g/L Satin.
          d.Finish Coats: Deft: DFT128 Deft Polyurethane Interior Oil-Based 350 g/L Semi-Gloss.
          e.Finish Coats: Deft. DFT127 Deft Polyurethane Interior Oil-Based 350 g/L Gloss.
          2.Waterborne Satin-Varnish Finish: Two finish coats of waterborne clear varnish over a sanding sealer. Wipe wood filler before applying stain.
          ** NOTE TO SPECIFIER ** Delete paste wood filler coat below for tight-grained wood such as birch or poplar. Keep filler coat for Oak and Walnut and similar open-grain woods. Delete filler coat if not required.
          a.Filler Coat: Open-Grain Wood Filler.
          b.Sealer Coat: Deft. DFT61 Sanding Sealer Interior Water-Based.
          ** NOTE TO SPECIFIER ** Delete filler coat options not required.
          c.Finish Coats: Deft. DFT159 Clear Polyurethane Interior Water-Based Acrylic Satin.
          d.Finish Coats: Deft. DFT158 Clear Polyurethane Interior Water-Based Acrylic Semi-Gloss.
          e.Finish Coats: Deft. DFT157 Clear Polyurethane Interior Water-Based Acrylic Gloss.
          ** NOTE TO SPECIFIER ** Three coats of wax are usually adequate for most work. Delete if not required.
          3.Alkyd-Based Sealer Wax-Polished Finish: Three finish coats of paste wax over a sanding-sealer. Wipe wood filler before applying stain.
          a.Filler Coat: Open-Grained Wood Filler.
          b.Sealer Coat: Deft: DFT60 Deft Sanding Sealer Interior Oil-Based. Not Compliant in OTC Phase I and II, LADCO, CARB 2000 and 2007, SCAQMD, CT, DE, MD, NH, UT and Maricopa County Arizona Air Quality Districts.
          c.Finish Coats: Paste wax.
          4.Waterborne Sealer Wax-Polished Finish: Three finish coats of paste wax over a sanding-sealer. Wipe wood filler before applying stain.
          a.Filler Coat: Open-Grained Wood Filler.
          b.Sealer Coat: Deft: DFT61 Deft Sanding Sealer Interior Water-Based.
          c.Finish Coats: Paste wax.
          ** NOTE TO SPECIFIER ** Flat finishes are not in this Article since flat high-performance coatings are seldom used on exteriors. If flat finish is required, consult manufacturers for recommendation. Delete article if not required.
 
          2.7EXTERIOR HIGH PERFORMANCE COATING SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required. Keep paragraph below for high-gloss polyurethane finish over concrete or brick masonry surfaces.
 
          A.Concrete and Masonry (Other Than Concrete Masonry Units): Provide the following finish systems over exterior concrete and brick masonry surfaces.
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          c.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          d.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          e.Intermediate Coat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          f.Topcoat: Semi-Gloss, Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          g.Topcoat: High-Gloss, Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          h.Topcoat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          ** NOTE TO SPECIFIER ** Keep paragraph below for high-gloss polyurethane finish over concrete masonry block.
 
          B.Concrete Masonry Units: Provide the following finish systems over exterior concrete masonry block:
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a block filler.
          a.Block Filler: PPG Paints. Amerlock 400BF Epoxy Block Filler. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat option not required.
          b.Intermediate Coat: Epoxy: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          c.Intermediate Coat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          d.Topcoat: Semi-Gloss, Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          e.Topcoat: High-Gloss, Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          f.Topcoat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          ** NOTE TO SPECIFIER ** Keep paragraph below for high-gloss acrylic finish over wood.
 
          C.Wood: Provide the following finish systems over exterior wood surfaces:
          1.Acrylic Finish: One finish coat over an intermediate coat and a primer.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip Interior/Exterior Acrylic Latex Stain Blocking Primer: Applied Dry Film Thickness: 1.6 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          b.Intermediate Coat: PPG Paints. 90-1110 Series Pitt-Tech Plus Tech Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          c.Intermediate Coat: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          d.Intermediate Coat: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          e.Intermediate Coat: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          f.Topcoat: PPG Paints. 90-1110 Series Pitt-Tech Plus Tech Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          g.Topcoat: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          h.Topcoat: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          i.Topcoat: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Keep paragraph below for high-gloss polyurethane finish over ferrous metal. Delete if not required.
 
          D.Ferrous Metal: Provide the following finish systems over exterior ferrous-metal surfaces:
          ** NOTE TO SPECIFIER ** Delete finish option not required.
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          c.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          d.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          e.Intermediate Coat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          f.Topcoat: Semi-Gloss, Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          g.Topcoat: High-Gloss, Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          h.Topcoat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          2.Fluoropolymer System: One finish coat applied over an epoxy primer.
          a.Primer: PPG Paints. Coraflon ADS Epoxy Primer ADS 573/ADS574. Not Compliant in SCAQMD. Applied Dry Film Thickness: 3.0 mils min.
          b.Finish: PPG Paints. Coraflon ADS Fluoropolymer. Not Compliant in SCAQMD. Apply per instructions on the technical data bulletin. Metallic finishes may require an additional clear coat of Coraflon ADS.
 
          E.Nonferrous Metal: Provide the following finish systems over exterior nonferrous-metal surfaces:
          ** NOTE TO SPECIFIER ** Delete finish option not required. Keep finish option below for high-gloss finish over nonferrous metal.
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          c.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          d.Intermediate Coat: Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          e.Intermediate Coat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          f.Topcoat: Semi-Gloss, Aliphatic Polyurethane Enamel: PPG Paints: 95-8801/95-859 Series Pitthane High Build Semi-Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          g.Topcoat: High-Gloss, Aliphatic Polyurethane Enamel: PPG Paints. 95-812/95-819 Series Pitthane Ultra Gloss Urethane Enamel. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 2.0 mils min.
          h.Topcoat: PPG Paints. AMV-3 Series Amershield VOC Low VOC Gloss Polyester Acrylic Polyurethane. Applied Dry Film Thickness: 3.0 mils min.
          2.Fluoropolymer System: One finish coat applied over an epoxy primer.
          a.Primer: PPG Paints. Coraflon ADS Epoxy Primer ADS 573/ADS574. Not Compliant in SCAQMD. Applied Dry Film Thickness: 3.0 mils min.
          b.Finish: PPG Paints. Coraflon ADS Fluoropolymer. Not Compliant in SCAQMD. Apply per instructions on the technical data bulletin. Metallic finishes may require an additional clear coat of Coraflon ADS.
          ** NOTE TO SPECIFIER ** Delete article if not required.
 
          2.8INTERIOR HIGH PERFORMANCE COATING SYSTEMS
          ** NOTE TO SPECIFIER ** Delete paragraphs not required.
 
          A.Concrete and Masonry (Other Than Concrete Masonry Units): Provide the following finish systems over interior concrete and brick masonry surfaces:
          1.Epoxy Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. 98E-46/98E-99 Series Aquapon WB EP Two-Component Waterborne Epoxy Primer. Applied Dry Film Thickness: 2.0 mils min.
          c.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          d.Intermediate Coat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          e.Intermediate Coat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          f.Intermediate Coat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          g.Intermediate Coat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          h.Intermediate Coat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          i.Topcoat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          j.Topcoat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          k.Topcoat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          l.Topcoat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          m.Topcoat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
 
          B.Concrete Masonry Units: Provide the following finish systems over interior concrete masonry block:
          ** NOTE TO SPECIFIER ** Keep finish below for high gloss finish over interior concrete masonry block.
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a block filler.
          a.Block Filler: PPG Paints. Amerlock 400BF Epoxy Block Filler. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          b.Intermediate Coat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          c.Intermediate Coat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          d.Intermediate Coat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          e.Intermediate Coat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          f.Intermediate Coat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          g.Topcoat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          h.Topcoat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          i.Topcoat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          j.Topcoat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          k.Topcoat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Keep paragraph for semigloss finish over interior concrete masonry block.
 
          C.Wood: Provide the following finish systems over interior wood surfaces:
          ** NOTE TO SPECIFIER ** Keep finish below for high gloss finish over interior wood surfaces. Delete if not required.
          1.Acrylic Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer option not required.
          a.Primer: PPG Paints. 17-921XI Series Seal Grip Interior/Exterior Acrylic Latex Stain Blocking Primer. Applied Dry Film Thickness: 1.6 mils min.
          b.Primer/Flat Acrylic Finish: PPG Paints: 4020 PF Pitt-Tech Plus Interior/Exterior Waterborne Acrylic Primer Finish. Applied Dry Film Thickness: 2.2 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          c.Intermediate Coat: PPG Paints. 90-1110 Series Pitt-Tech Plus Tech Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          d.Intermediate Coat: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          e.Intermediate Coat: PPG Paints 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          f.Intermediate Coat: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          g.Topcoat: PPG Paints. 90-1110 Series Pitt-Tech Plus Tech Interior/Exterior Satin DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
          h.Topcoat: PPG Paints. 4216 HP Series Pitt-Tech Plus Interior/Exterior high performance waterborne Semi-Gloss DTM Enamel. Applied Dry Film Thickness: 1.5 mils min.
          i.Topcoat: PPG Paints. 6-8534 Series Speedhide Interior/Exterior High Gloss Acrylic Paint. Applied Dry Film Thickness: 1.2 mils min.
          j.Topcoat: PPG Paints. 90-1310 Series Pitt-Tech Plus Interior/Exterior High Gloss DTM Industrial Enamel. Applied Dry Film Thickness: 2.0 mils min.
 
          D.Ferrous Metal: Provide the following finish systems over interior ferrous-metal surfaces:
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. 98E-46/98E-99 Series Aquapon WB EP Two-Component Waterborne Epoxy Primer. Applied Dry Film Thickness: 2.0 mils min.
          c.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          d.Intermediate Coat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          e.Intermediate Coat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          f.Intermediate Coat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          g.Intermediate Coat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          h.Intermediate Coat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          i.Topcoat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          j.Topcoat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          k.Topcoat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          l.Topcoat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          m.Topcoat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          2.Fluoropolymer System: One finish coat applied over an epoxy primer.
          a.Primer: PPG Paints. Coraflon ADS Epoxy Primer ADS 573/ADS574. Not Compliant in SCAQMD. Applied Dry Film Thickness: 3.0 mils min.
          b.Finish: PPG Paints. Coraflon ADS Fluoropolymer. Not Compliant in SCAQMD. Apply per instructions on the technical data bulletin. Metallic finishes may require an additional clear coat of Coraflon ADS.
 
          E.Nonferrous Metal: Provide the following finish systems over interior nonferrous-metal surfaces:
          1.Epoxy with Urethane Finish: One finish coat over an intermediate coat and a primer.
          ** NOTE TO SPECIFIER ** Delete primer options not required.
          a.Primer: PPG Paints. 95-245/95-249 Series Pitt-Guard Rapid Coat DTR Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          b.Primer: PPG Paints. 98E-46/98E-99 Series Aquapon WB EP Two-Component Waterborne Epoxy Primer. Applied Dry Film Thickness: 2.0 mils min.
          c.Primer: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          ** NOTE TO SPECIFIER ** Delete intermediate coat options not required.
          d.Intermediate Coat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          e.Intermediate Coat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          f.Intermediate Coat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          g.Intermediate Coat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          h.Intermediate Coat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          ** NOTE TO SPECIFIER ** Delete topcoat options not required.
          i.Topcoat: PPG Paints. 97-1212/97-139 Series Aquapon High Build Semi-Gloss Polyamide Epoxy Coating. Not Compliant in OTC Phase II, CARB 2007, SCAQMD, CT, DE, MD and UT Air Quality Districts. Applied Dry Film Thickness: 4.0 mils min.
          j.Topcoat: PPG Paints. 98E-1/98E-100 Series Aquapon WB EP Two-Component Waterborne Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          k.Topcoat: PPG Paints. AK2V-3 Series Amerlock 2 VOC Fast Dry, High Solids Semi-Gloss Epoxy Coating. Applied Dry Film Thickness: 4.0 mils min.
          l.Topcoat: PPG Paints. 95-501/95-506 Series High Gloss Polyamide-Epoxy Coating. Not Compliant in SCAQMD. Applied Dry Film Thickness: 4.0 mils min.
          m.Topcoat: PPG Paints. 98E-1/98E-98 Series Aquapon WB EP Two-Component Waterborne Gloss Epoxy Coating. Applied Dry Film Thickness: 2.0 mils min.
          2.Fluoropolymer System: One finish coat applied over an epoxy primer.
          a.Primer: PPG Paints. Coraflon ADS Epoxy Primer ADS 573/ADS574. Not Compliant in SCAQMD. Applied Dry Film Thickness: 3.0 mils min.
          b.Finish: PPG Paints. Coraflon ADS Fluoropolymer. Not Compliant in SCAQMD. Apply per instructions on the technical data bulletin. Metallic finishes may require an additional clear coat of Coraflon ADS.
 
          PART 3EXECUTION
 
          3.1EXAMINATION
 
          A.Do not begin installation until substrates have been properly prepared.
 
          B.If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
 
          C.Coordination of Work: Review other Sections in which primers are provided to ensure compatibility of the total system for various substrates. On request, furnish information on characteristics of finish materials to ensure use of compatible primers.
          1.Notify Architect about anticipated problems when using the materials specified over substrates primed by others.
          ** NOTE TO SPECIFIER ** Coordinate primers specified in other Sections with undercoats and finish coats specified in this Section to ensure compatibility of materials. Some high-performance coatings will lift incompatible primers or have poor adhesion when applied over zinc-based or baked primers. Delete if not required.
          2.If a potential incompatibility of primers applied by others exists, obtain the following from the primer Applicator before proceeding:
          a.Confirmation of primer's suitability for expected service conditions.
          b.Confirmation of primer's ability to be top coated with materials specified.
 
          3.2PREPARATION
 
          A.General: Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items already installed that are not to be painted. If removal is impractical or impossible because of size or weight of the item, provide surface-applied protection before surface preparation and painting.
          1.After completing painting operations in each space or area, reinstall items removed using workers skilled in the trades involved.
 
          B.Cleaning: Before applying paint or other surface treatments, clean substrates of substances that could impair bond of the various coatings. Remove oil and grease before cleaning.
          1.Schedule cleaning and painting so dust and other contaminants from the cleaning process will not fall on wet, newly painted surfaces.
 
          C.Surface Preparation: Clean and prepare surfaces to be painted according to manufacturer's written instructions for each particular substrate condition and as specified.
          1.Provide barrier coats over incompatible primers or remove and reprime.
          ** NOTE TO SPECIFIER ** Coordination of shop-applied prime coats with high-performance coatings is critical. If compatibility problems exist, it may be necessary to provide barrier coats over primers or to remove primer and reprime substrate. Delete if not required.
          2.Provide barrier coats over incompatible primers or remove primers and reprime substrate.
          ** NOTE TO SPECIFIER ** Delete subparagraph and associated subparagraphs below if cementitious surfaces are not to be coated, or revise to suit Project.
          3.Cementitious Substrates: Prepare concrete, brick, concrete masonry block, and cement plaster surfaces to be coated. Remove efflorescence, chalk, dust, dirt, grease, oils, and release agents. Roughen as required to remove glaze. If hardeners or sealers have been used to improve curing, use mechanical methods to prepare surfaces.
          a.Use abrasive blast-cleaning methods if recommended by coating manufacturer.
          b.Determine alkalinity and moisture content of surfaces by performing appropriate tests. If surfaces are sufficiently alkaline to cause the finish paint to blister and burn, correct this condition before application. Do not coat surfaces if moisture content exceeds that permitted in manufacturer's written instructions.
          ** NOTE TO SPECIFIER ** Delete subparagraph and associated subparagraphs below if wood surfaces are not to be coated, or revise to suit Project.
          4.Wood Substrates: Clean surfaces of dirt, oil, and other foreign substances with scrapers, mineral spirits, and sandpaper, as required. Smoothly sand surfaces exposed to view and dust off.
          a.Scrape and clean small, dry, seasoned knots, and apply a thin coat of white shellac or other recommended knot sealer, before applying primer.
          b.Immediately on delivery, prime edges, ends, faces, undersides, and backsides of wood to be coated.
          c.After priming, fill holes and imperfections in the finish surfaces with putty or plastic wood filler. Sand smooth when dried.
          ** NOTE TO SPECIFIER ** Delete subparagraph and associated subparagraphs below if ferrous metal surfaces are not to be coated, or revise to suit Project.
          5.Ferrous Metal Substrates: Clean ungalvanized ferrous-metal surfaces that have not been shop coated: remove oil, grease, dirt, loose mill scale, and other foreign substances. Use solvent or mechanical cleaning methods that comply with SSPC recommendations.
          ** NOTE TO SPECIFIER ** Delete subparagraph below if blast cleaning is not required. SSPC-SP 10 requires a higher level of preparation than may be justified. Reduce preparation to SSPC-SP 6 if circumstances warrant.
          a.Blast-clean steel surfaces as recommended by coating manufacturer and according to SSPC-SP 10.
          ** NOTE TO SPECIFIER ** Delete subparagraph below if this treatment is not required.
          b.Treat bare and sandblasted or pickled clean metal with a metal treatment wash coat before priming.
          ** NOTE TO SPECIFIER ** Delete subparagraph below if touchup painting of shop-applied primers will be done by material erector or Installer.
          c.Touch up bare areas and shop-applied prime coats that have been damaged. Wire brush, solvent clean, and touch up with same primer as the shop coat.
          ** NOTE TO SPECIFIER ** Delete subparagraph and associated subparagraph below if nonferrous metal surfaces are not to be coated, or revise to suit Project.
          6.Nonferrous-Metal Substrates: Clean nonferrous and galvanized surfaces according to manufacturer's written instructions for the type of service, metal substrate, and application required.
          a.Remove pretreatment from galvanized sheet metal fabricated from coil stock by mechanical methods.
 
          D.Material Preparation: Carefully mix and prepare coating materials according to manufacturer's written instructions.
          1.Maintain containers used in mixing and applying coatings in a clean condition, free of foreign materials and residue.
          2.Stir materials before applying to produce a mixture of uniform density. Stir as required during application. Do not stir surface film into the material. Remove film and, if necessary, strain coating material before using.
          3.Use only the type of thinners approved by manufacturer and only within recommended limits.
          ** NOTE TO SPECIFIER ** If tinting is not required, delete below. Different tints will show through as topcoat erodes.
          4.Tinting: Tint each undercoat a lighter shade to simplify identification of each coat when multiple coats of same material are applied. Tint undercoats to match the color of the finish coat, but provide sufficient differences in shade of undercoats to distinguish each separate coat.
 
          3.3APPLICATION
          ** NOTE TO SPECIFIER ** Commercial coatings only. Delete if not required.
 
          A.General: Apply paint according to manufacturer's written instructions. Use applicators and techniques best suited for substrate and type of material being applied.
          ** NOTE TO SPECIFIER ** High performance coatings only. Delete if not required.
 
          B.General: Apply high-performance coatings according to manufacturer's written instructions.
          1.Use applicators and techniques best suited for the material being applied.
          2.Do not apply high-performance coatings over dirt, rust, scale, grease, moisture, scuffed surfaces, or conditions detrimental to forming a durable coating film.
          3.Coating surface treatments, and finishes are indicated in the coating system descriptions.
          4.Provide finish coats compatible with primers used.
          5.The term "exposed surfaces" includes areas visible when permanent or built-in fixtures, convector covers, grilles, covers for finned-tube radiation, and similar components are in place. Extend coatings in these areas, as required, to maintain system integrity and provide desired protection.
 
          C.Application Procedures: Apply coatings by brush, roller, spray, or other applicators according to manufacturer's written instructions.
          1.The number of coats and film thickness required is the same regardless of application method.
          2.Completed Work: Match approved Samples for color, texture, and coverage. Remove, refinish, or recoat work that does not comply with specified requirements.
 
          3.4FIELD QUALITY CONTROL
 
          A.Owner reserves the right to invoke the following test procedure at any time and as often as Owner deems necessary during the period when paint is being applied:
          1.Owner will engage a qualified independent testing agency to sample paint material being used. Samples of material delivered to Project will be taken, identified, sealed, and certified in the presence of Contractor.
          2.Owner may direct Contractor to stop painting if test results show material being used does not comply with specified requirements. Contractor shall remove noncomplying paint from Project site, pay for testing, and repaint surfaces previously coated with the noncomplying paint. If necessary, Contractor may be required to remove noncomplying paint from previously painted surfaces if, on repainting with specified paint, the two coatings are incompatible.
 
          3.5CLEANING
 
          A.After completing painting, clean glass and paint spattered surfaces. Remove spattered paint by washing and scraping without scratching or damaging adjacent finished surfaces.
 
          3.6PROTECTION
 
          A.Protect work of other trades, whether being painted or not, against damage from painting. Correct damage by cleaning, repairing or replacing, and repainting, as approved by Architect.
 
          B.Provide "Wet Paint" signs to protect newly painted finishes. After completing painting operations, remove temporary protective wrappings provided by others to protect their work.
 
          C.After work of other trades is complete, touch up and restore damaged or defaced painted surfaces.
 
         
END OF SECTION