| Find over 500 more construction specifications | Arcat.com |
![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||
This section is based on the products of Columbia Manufacturing Co. Ltd., which is located at: 4575 Tillicum St. Burnaby, BC, Canada V5J 3J9 Toll Free Tel: 888-437-5557 Tel: 604-437-3377 Fax: 604-437-4443 Email: request info Web: www.columbiaskylights.com [ Click Here ] for additional information. Columbia Manufacturing is an industry leading North American Skylight manufacturer. For over 50 years Columbia has been producing residential and commercial Skylights that stand up to the harshest climates. Harnessing traditions of smart engineering, product innovation, quality craftsmanship and courteous service Columbia offers the best in Range, Quality and Price. Columbia's Commercial unit Skylights have been included on Costco, Home Depot and Rona Stores. They have been used by leading general contractors in Canada and the United States on industrial manufacturing and distribution centers. Columbia Manufacturing product portfolio includes: Curb Mounted Skylights, Self Flashing Skylights, Wood Deck Mount Skylights, Curb Mount Pyramids, Sun Tubes, Circular Roof Domes and Roof Access Hatches. For more information please contact the Columbia customer service team. | ||||||||||||||||||||||||||||||||||||||||||||||||||
| PART 1 | GENERAL | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.1 | SECTION INCLUDES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Curb-mounted skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Self-flashing skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Wood deck mount skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Sun tubes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Circular roof domes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Roof access skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.2 | RELATED SECTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Section 07500 - Membrane Roofing: Coordination and installation of flashing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Section 07600 - Flashing and Sheet Metal: Coordination and installation of counter flashing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Section 07920 - Sealants: Products and installation provisions for perimeter sealant. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Section 08800 - Glass: Products and installation provisions for glass. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.3 | REFERENCES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | American Architectural Manufacturers Association (AAMA): AAMA 101 - Specification for windows, doors and skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | ASTM International (ASTM): | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | ASTM E 547 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Canadian Standards Organization (CSA): CSA A440 Specification for windows, doors and skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | North American Fenestration Standard (NAFS): Specification for windows, doors and skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Window and Door Manufacturers Association (WDMA): WDMA 1.S 2 - Specification for windows, doors and skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.4 | SUBMITTALS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Submit under provisions of Section 01300. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Product Data: Manufacturer's data sheets for each assembly specified, including but not limited to: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Performance characteristics. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Preparation instructions and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Storage and handling requirements and recommendations. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Installation Instructions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Shop Drawings: Provide shop drawings showing details including but not limited to plans, elevations, sections, fabrication, installation, anchorage, interface of the work of this section with the work of adjacent trades and details, indicating dimensions, tolerances and finishes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Selection Samples: For each assembly type, two complete sets of samples representing manufacturer's full range of available product assembly types and finishes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Verification Samples: For each finish product specified, two sample chips representing actual product assembly types and finishes specified. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.5 | QUALITY ASSURANCE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Manufacturer Qualifications: Skylight manufacturer shall have a minimum of twenty years experience in skylight manufacturing, qualified by having performed similar work and having experienced workmen to perform work of type required by contract documents and licensed where appropriate. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.6 | DELIVERY, STORAGE AND HANDLING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Store products indoors in manufacturer's or fabricator's original containers and packaging, with labels clearly identifying product name and manufacturer. Protect from damage. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.7 | PROJECT CONDITIONS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.8 | SEQUENCING AND SCHEDULING | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Conference: Convene a pre-installation conference to establish procedures to maintain optimum working conditions and to coordinate this work with related and adjacent work. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1.9 | WARRANTY | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Manufacturer's Standard Limited Warranty: To be free from defects in material and workmanship. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Warranty Period: 20 years for insulated sealed glass units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Warranty Period: 10 years for wood deck mount skylights and flashing components. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Warranty Period: 10 years for curb mount skylights and flashing components. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Warranty Period: 10 years for self flashing skylights | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Warranty Period: 10 years for sun tubes | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Warranty Period: 5 years for roof access hatches. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Warranty Period: 5 years for circular roof domes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Warranty Period: 5 years for polycarbonate skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Warranty Period: 5 years for motorized operators, rain sensors, handles, rods and manual operators. | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 2 | PRODUCTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.1 | MANUFACTURERS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Acceptable Manufacturer: Columbia Manufacturing Co. Ltd., which is located at: 4575 Tillicum St. ; Burnaby, BC, Canada V5J 3J9; Toll Free Tel: 888-437-5557; Tel: 604-437-3377; Fax: 604-437-4443; Email: request info; Web: www.columbiaskylights.com | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Substitutions: Not permitted. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Requests for substitutions will be considered in accordance with provisions of Section 01600. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.2 | CURB MOUNTED SKYLIGHTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Venting Curb Mount Skylights: OVCM-E ELITE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled curb mounted unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. Requires site built curb by others. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Sentry II Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: LED Remote, battery operated; controls an infinite number of skylights, includes a built in thermostat and group programming enabling simultaneous control of up to 9 skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Venting Curb Mount Skylights: OVCM-E DELUXE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. Requires site built curb by others. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: Slim Line infra-ed remote, battery operated; controls up to 6 skylights at 50 ft (15 m) range. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Venting Curb Mount Skylights: OVCM-E STANDARD as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. Requires site built curb by others. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited skylight motor, decorative cover and a wall switch designed for a standard single gang electrical box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Wall switch operates up to four skylights; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Venting Curb Mount Skylights: OVCM MANUAL as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. Requires site built curb by others. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| g. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| h. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| i. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| j. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| k. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Operation: Interchangeable removable handles with hexball adaptor for operation with extension poles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Operator: Truth Hardware manual white chain operator fitted to sash with bracket and removable pin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Maximum Chain Extension: 9 inches (229 mm) and includes limit stop. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Type: As scheduled and indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Type: Standard, crank handle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Type: Telescopic extension pole, 4 feet - 6 feet (1219 mm - 1829 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Type: Telescopic extension pole, 6 feet - 10 feet (1829 mm - 3048 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Fixed Curb Mount Skylights: VCM-IF (inside fastening) as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, site built (curb by others) curb mounted unit consisting of thermally broken, maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Attachment: Inside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Fixed Curb Mount Skylights: VCM-OF (outside fastening) as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken, maintenance free vinyl (PVC) extrusion base frame. Requires site built curb by others | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Fixed Curb Mount Skylights: ATCM-IF (inside fastening) as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken mill finish aluminum extrusion base frame. Requires site built curb by others. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Base Frame: Thermally broken aluminum base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Corners: Heliarc welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Inside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Fixed Curb Mount Skylights: ATCM-OF (outside fastening) as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, curb mounted unit consisting of thermally broken mill finish aluminum extrusion base frame. Requires site built curb by others | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Base Frame: Thermally broken aluminum base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Corners: Heliarc welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Flashing: As scheduled and indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Flashing: Standard flashing kit, pre-cut steps, counter flashing and pre-formed head and sill flashing; not for flat roofs. | |||||||||||||||||||||||||||||||||||||||||||||||||
| K. | Flashing: Cant strip and customized flashings as indicated on Drawings; for flat roofs. | |||||||||||||||||||||||||||||||||||||||||||||||||
| L. | Finishes: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Exterior Frame Finish: Custom color, _______________. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Exterior Frame Finish: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Exterior Frame Finish: Standard, baked enamel finish, Rideau brown. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Exterior Frame Finish: Black. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Exterior Frame Finish: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Exterior Frame Finish: Grey. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Exterior Frame Finish: Sandalwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Exterior Frame Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Exterior Frame Finish: Clear anodized. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interior Frame Finish: White vinyl base frame matches interior light shaft. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Interior Frame Finish: Mill finish aluminum base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| M. | Glazing: Dual seal Insulated glass units; refer to glazing schedule for technical attributes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: LoE3 Clear with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: LoE3 Neat with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: LoE3 i81 with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: LoE3 Triple Glazed Clear with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: LoE3 Bronze with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: LoE3 Solar Reflective Bronze with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Type: Heat Mirror 44 with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| N. | Glazing: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: Acrylic sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: Acrylic sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: Acrylic sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: Polycarbonate sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: Polycarbonate sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: Polycarbonate sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Color: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Glazing Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Glazing Color: Bronze (color code 2412) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Glazing Color: White (color code 2447) | |||||||||||||||||||||||||||||||||||||||||||||||||
| O. | Size: Curb rough opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Models: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Model 2020: 14.5 by 14.5 inches (368 by 368 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Model 2028: 14.5 by 22.5 inches (368 by 572 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Model 2036: 14.5 by 30.5 inches (368 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Model 2052: 14.5 by 46.5 inches (368 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Model 2076: 14.5 by 70.5 inches (368 by 1791 mm)*N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Model 2828: 22.5 by 22.5 inches (572 by 572 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Model 2836: 22.5 by 30.5 inches (572 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Model 2840: 22.5 by 34.5 inches (572 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Model 2852: 22.5 by 46.5 inches (572 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Model 2868: 22.5 by 62.5 inches (572 by 1588 mm)*N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Model 2876: 22.5 by 70.5 inches (572 by 1791 mm)*N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Model 28100: 22.5 by 94.5 inches (572 by 2400 mm)*N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Model 3636: 30.5 by 30.5 inches (775 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Model 3652: 30.5 by 46.5 inches (775 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Model 3668: 30.5 by 62.5 inches (775 by 1588 mm) *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Model 3676: 30.5 by 70.5 inches (775 by 1791 mm)*N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Model 4040: 34.5 by 34.5 inches (876 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Model 4052: 34.5 by 46.5 inches (876 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Model 4064: 34.5 by 58.5 inches (876 by 1486 mm) *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Model 4076: 34.5 by 70.5 inches (876 by 1791 mm) *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Model 4242: 36.5 by 36.5 inches (927 by 927 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Model 5252: 46.5 by 46.5 inches (1181 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Model 36100: 30.5 by 94.5 inches (775 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 25. | Model 40100: 34.5 by 94.5 inches (876 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 26. | Model 4280: 36.5 by 74.5 inches (927 by 1892 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 27. | Model 5264: 46.5 by 58.5 inches (1181 by 1486 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 28. | Model 5276: 46.5 by 70.5 inches (1181 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 29. | Model 6060: 54.5 by 54.5 inches (1384 by 1384 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 30. | Model 52100: 46.5 by 94.5 inches (1181 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 31. | Model 52120: 46.5 by 114.5 inches (1181 by 2908 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 32. | Model 60100: 54.5 by 94.5 inches (1384 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 33. | Model 60120: 54.5 by 114.5 inches (1384 by 2908 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 34. | Model 6464: 58.5 by 58.5 inches (1486 by 1486 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 35. | Model 6476: 58.5 by 70.5 inches (1486 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 36. | Model 64100: 58.5 by 94.5 inches (1486 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 37. | Model 7676: 70.5 by 70.5 inches (1791 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 38. | Model 76100: 70.5 by 94.5 inches (1791 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 39. | Model 76120: 70.5 by 114.5 inches (1791 by 2908 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 40. | Model 8484: 78.5 by 78.5 inches (1994 by 1994 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 41. | Model 84100: 78.5 by 94.5 inches (1994 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 42. | Model 100100: 94.5 by 94.5 inches (2400 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.3 | SELF FLASHING SKYLIGHTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Venting Self Flashing Skylights: OVSF-E ELITE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, site built self flashing unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Sentry II Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: LED Remote, battery operated; controls an infinite number of skylights, includes a built in thermostat and group programming enabling simultaneous control of up to 9 skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Venting Self Flashing Skylights: OVSF-E DELUXE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, site built self flashing unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: Slim Line infra-ed remote, battery operated; controls up to 4 skylights at 50 ft (15 m) range. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Venting Self Flashing Skylights: OVSF-E STANDARD as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, self flashing unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Products supplied with the following glass glazing shall bear the Energy Star label: Loe3 Clear, Loe3 Neat, Loe3 i81, Loe3 Triple glazed, Loe3 Bronze, Loe3 Solar reflective bronze and Heat Mirror 44 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited skylight motor, decorative cover and a wall switch designed for a standard single gang electrical box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Wall switch operates up to four skylights; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Motors: Require standard 110 volt wall outlet. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Venting Self Flashing Skylights: OVSF MANUAL as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, self flashing unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Each product supplied shall bear the Energy Star label. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Interchangeable removable handles with hexball adaptor for operation with extension poles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Operator: Truth Hardware manual white chain operator fitted to sash with bracket and removable pin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Maximum Chain Extension: 9 inches (229 mm) and includes limit stop. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Type: As scheduled and indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Type: Standard, crank handle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Type: Telescopic extension pole, 4 feet - 6 feet (1219 mm - 1829 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Type: Telescopic extension pole, 6 feet - 10 feet (1829 mm - 3048 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Fixed Self Flashing Skylights: VSF as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, self flashing unit consisting of thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Attachment: Inside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Flashing: Base frame includes a built in vinyl curb and wide flashing flange for optimum seal. Slotted fastening holes around perimeter of flange allow for expansion and contraction. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Finishes: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Exterior Frame Finish: Custom color, _______________. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Exterior Frame Finish: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Exterior Frame Finish: Standard, baked enamel finish, Rideau brown. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Exterior Frame Finish: Black. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Exterior Frame Finish: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Exterior Frame Finish: Grey. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Exterior Frame Finish: Sandalwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Exterior Frame Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Exterior Frame Finish: Clear anodized. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Frame Finish: White vinyl base frame matches interior light shaft. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Glazing: Dual seal Insulated glass units; refer to glazing schedule for technical attributes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: LoE3 Clear with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: LoE3 Neat with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: LoE3 i81 with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: LoE3 Triple Glazed Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: LoE3 Bronze with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: LoE3 Solar Reflective Bronze with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Type: Heat Mirror 44 with argon gas | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Glazing: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: Acrylic sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: Acrylic sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: Polycarbonate sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: Polycarbonate sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Color: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Color: Bronze (color code 2412) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Glazing Color: White (color code 2447) | |||||||||||||||||||||||||||||||||||||||||||||||||
| J. | Size: Rough opening | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Models as scheduled or indicated on drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Model 2020: 14.5 by 14.5 inches (368 by 368 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Model 2028: 14.5 by 22.5 inches (368 by 572 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Model 2036: 14.5 by 30.5 inches (368 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Model 2052: 14.5 by 46.5 inches (368 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Model 2076: 14.5 by 70.5 inches (368 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Model 2828: 22.5 by 22.5 inches (572 by 572 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Model 2836: 22.5 by 30.5 inches (572 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Model 2840: 22.5 by 34.5 inches (572 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Model 2852: 22.5 by 46.5 inches (572 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Model 2868: 22.5 by 62.5 inches (572 by 1588 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Model 2876: 22.5 by 70.5 inches (572 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Model 28100: 22.5 by 94.5 inches (572 by 2400 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Model 3636: 30.5 by 30.5 inches (775 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Model 3652: 30.5 by 46.5 inches (775 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Model 3668: 30.5 by 62.5 inches (775 by 1588 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Model 3676: 30.5 by 70.5 inches (775 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Model 4040: 34.5 by 34.5 inches (876 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Model 4052: 34.5 by 46.5 inches (876 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 20. | Model 4242: 36.5 by 36.5 inches (927 by 927 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 21. | Model 4280: 36.5 by 74.5 inches (927 by 1892 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 22. | Model 5252: 46.5 by 46.5 inches (1181 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 23. | Model 5276: 46.5 by 70.5 inches (1181 by 1791 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 24. | Model 6060: 54.5 by 54.5 inches (1384 by 1384 mm). *N/A in Venting option. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.4 | WOOD DECK MOUNTED SKYLIGHTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Venting Wood Deck Mount Skylights: CVS-E ELITE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, wood deck mount skylight consisting of Douglas fir wooden curb and thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Douglas Fir curb and PVC vinyl extrusion | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Sentry II Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: LED Remote, battery operated; controls an infinite number of skylights, includes a built in thermostat and group programming enabling simultaneous control of up to 9 skylights. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Venting Wood Deck Mount Skylights: CVS-E DELUXE as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, wood deck mount skylight consisting of Douglas fir wooden curb and thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited to skylight motor, decorative cover, remote control and rain sensor. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Douglas Fir curb and PVC vinyl extrusion | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Remote control operation; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Remote: Slim Line infra-ed remote, battery operated; controls up to 4 skylights at 50 ft (15 m) range. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Rain Sensors: Automatically close skylights during inclement weather. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Venting Wood Deck Mount Skylights: CVS-E STANDARD as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, wood deck mount skylight consisting of Douglas fir wooden curb and thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: Including but not limited skylight motor, decorative cover and a wall switch designed for a standard single gang electrical box. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Wall switch operates up to four skylights; outward opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Chain Mechanism: Marvel Electric chain drive venting operation designed by Truth Hardware. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Motors: Require standard 110 volt household current | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Motor Covers: Decorative covers for motors. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Venting Wood Deck Mount Skylights: CVS MANUAL as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, wood deck mount skylight consisting of Douglas fir wooden curb and thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Each product supplied shall bear the Energy Star label. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Removable Insect Screens: Factory installed; spring loaded pins to allow for removal and installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Operation: Interchangeable removable handles with hexball adaptor for operation with extension poles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Operator: Truth Hardware manual white chain operator fitted to sash with bracket and removable pin. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Maximum Chain Extension: 9 inches (229 mm) and includes limit stop. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Type: As scheduled and indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Type: Standard, crank handle. | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Type: Telescopic extension pole, 4 feet - 6 feet (1219 mm - 1829 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| f. | Type: Telescopic extension pole, 6 feet - 10 feet (1829 mm - 3048 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Attachment: Outside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Fixed Wood Deck Mount Skylights: CFS as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Factory assembled, wood deck mount skylight consisting of Douglas fir wooden curb and thermally broken, two-piece maintenance free vinyl (PVC) extrusion base frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: Tested in accordance with AAMA/WDMA/CSA101/I.S.2/A440NAFS. | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Unit skylights meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Unit skylights meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Components: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Base Frame: Vinyl extrusion. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Corners: Fusion welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Gasketing: Co-extruded santoptrene gasket between glazing and frames. | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Exterior Fasteners in Frame: 300 series stainless steel. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Frame Drainage: Large capacity condensation gutter with weep holes at the corners. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Attachment: Inside fastening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Flashing: Pre-cut steps, counter flashing and pre-formed head and sill flashing. Columbia flashing kit must be used with both venting and fixed wood deck mount skylights in order to maintain warranty | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Finishes: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Exterior Frame Finish: Custom color, _______________. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Exterior Frame Finish: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Exterior Frame Finish: Standard, baked enamel finish, Rideau brown. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Exterior Frame Finish: Black. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Exterior Frame Finish: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Exterior Frame Finish: Grey. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Exterior Frame Finish: Sandalwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Exterior Frame Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Exterior Frame Finish: Clear anodized. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interior Frame Finish: Douglas Fir | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Glazing: Dual seal Insulated glass units; refer to glazing schedule for technical attributes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: LoE3 Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: LoE3 Neat. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: LoE3 i81. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: LoE3 Triple Glazed Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: LoE3 Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: LoE3 Solar Reflective Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Type: Heat Mirror 44. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Wood Deck Mount Skylights: Factory assembled, site built deck mounted unit consisting of a Douglas Fir Curb. | |||||||||||||||||||||||||||||||||||||||||||||||||
| I. | Size: Rough openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Model 056: 14.5 by 45.25 inches (368 by 1150 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Model 101: 21.75 by 28 inches (553 by 711 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Model 104: 21.75 by 37 inches (553 by 940 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Model 106: 21.75 by 45.25 inches (553 by 1150 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Model 108: 21.75 by 55 inches (553 by 1397 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Model 112: 21.75 by 71 inches (553 by 1803 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Model 302: 29.75 by 29.75 inches (756 by 756 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Model 304: 29.75 by 37 inches (756 by 940 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Model 306: 29.75 by 45.25 inches (756 by 1150 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Model 308: 29.75 by 55 inches (756 by 1397 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Model 606: 45.25 by 46.5 inches (1150 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.5 | SUN TUBES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Sun Tubes: RST - SLOPED ROOF as supplied by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Rigid Sun Tube for sloped roof applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Sun Tubes meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration: Sun Tubes meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Sun Tubes meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Each product supplied shall bear the Energy Star label. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Size: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Size: 10 Inches (254 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Size: 13 inches (330 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Size: 18 inches (457 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Sun Tubes: RST - FLAT ROOF as supplied by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Rigid Sun Tube for flat roof applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Compliance: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Load Testing: Sun Tubes meeting requirements of uniform load test ASTM E 330; withstands positive and negative test pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Test Pressures: +/- __________ psf. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2) | Deflection of Framing Members: Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Air Infiltration Sun Tubes meeting requirements of ASTM E 283. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Air Infiltration: ____ cfm (___ cu. m/m) of total glazed surface area. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Water Infiltration: Unit skylights meeting requirements of ASTM E 547/E 331. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1) | Maximum Water Infiltration (at test pressure +/- ___ psf): Shall not exceed __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| d. | Performance Rating: __________ . | |||||||||||||||||||||||||||||||||||||||||||||||||
| e. | Energy Star Rating: Each product supplied shall bear the Energy Star label. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Size: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Size: 10 Inches (254 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Size: 13 inches (330 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Size: 18 inches (457 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Sun Tubes: RST-C as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Rigid Sun Tube for flat roof applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Size: 21 inches (533 mm diameter). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Roof Jacks: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Flat: Constructed of pure grade 1100 series aluminum, flat round flashing ring for installation on flat roofs. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Curb mounted: Constructed of pure grade 1100 series aluminum, square flashing fits easily over site built curb. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Finishing: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Hard rock: Standard Trim ring for sheet rock ceilings | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Drop ceiling: for standard office/ T bar applications. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | Warehouse version: warehouse trim ring for suspended applications | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Construction: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Tubes: Silver coated aluminum light pipe (98 percent reflectivity). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Domes: High impact modified acrylic dome. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Frames: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Residential RST: Black baked enamel heavy duty aluminum frame. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | Commercial RST-C: Mill finish aluminum frame | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Roof Jacks: Designed to accommodate roof slopes ranging from 0 degrees to 60. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Lens Diffusers: Double glazed, prismatic. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Lens Diffusers: Double glazed, soft white. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Ceiling Rings: Factory assembled powder coated, white. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Accessories: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Extension Pipes: 24 inch (610 mm) extension pipe constructed of silver coated aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Elbow: Silver coated aluminum, adjustable from 0 - 45 degrees | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Remote Dimmer Kits: Including but not limited to remote, rotating reflective dimmer panel, light pipe, 120volt motor, remote activated control box | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Electric Light Kits: Factory assembled lamp brackets attached to light pipe with supplied nuts and washers; kit wired to 120 VAC supply by a licensed electrician. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Turret Extensions: To accommodate additional height of S-tiles. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Tile Skirts: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.6 | CIRCULAR ROOF DOMES | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Circular Roof Domes: As manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Description: Fixed Circular Roof Dome | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Sizes: As indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Sizes: Model C48R - 42 inches (1067 mm) diameter rough opening | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Sizes: Model C72R - 66.5 inches (1689 mm) diameter rough opening. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Construction: Built in, non-condensation, double wall brown fiberglass curb and retaining frame. The built in curb measures six inches (152 mm) in height and includes a wide flashing flange to ensure optimum seal. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Glazing: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: Acrylic sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: Acrylic sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: Acrylic sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: Polycarbonate sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: Polycarbonate sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: Polycarbonate sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Color: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Glazing Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Glazing Color: Bronze (color code 2412) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Glazing Color: White. (color code 2447) | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.7 | ROOF ACCESS SKYLIGHTS | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Roof Access Skylights: ATCM-RAS with thermally broken frame as manufactured by Columbia Manufacturing. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Operation: Pull bar, locking latch, and hydraulic gas cylinders that support the skylight when in the open position. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Retaining Frame: Extruded aluminum. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Base Frame: Thermally broken frame, extruded aluminum, heliarc welded. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Finishes: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Exterior Frame Finish: Custom color, _______________. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Exterior Frame Finish: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Exterior Frame Finish: Standard, baked enamel finish, Rideau brown. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Exterior Frame Finish: Black. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Exterior Frame Finish: White. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Exterior Frame Finish: Grey. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Exterior Frame Finish: Sandalwood. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Exterior Frame Finish: Mill finish. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Exterior Frame Finish: Clear anodized. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Interior Frame Finish: White vinyl base frame matches interior light shaft. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Glazing: Dual seal insulated glass units; refer to glazing schedule for technical attributes. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Glazing Type: LoE3 Clear with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Glazing Type: LoE3 Neat with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Glazing Type: LoE3 i81 with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Glazing Type: LoE3 Triple Glazed Clear with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Glazing Type: LoE3 Bronze with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Glazing Type: LoE3 Solar Reflective Bronze with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Glazing Type: Heat Mirror 44 with argon gas. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Glazing Type: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Glazing Type: Acrylic sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Glazing Type: Acrylic sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Glazing Type: Acrylic sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Glazing Type: Polycarbonate sheet in single glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Glazing Type: Polycarbonate sheet in double glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Glazing Type: Polycarbonate sheet in triple glazed units. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Glazing Color: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Glazing Color: Clear. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 18. | Glazing Color: Bronze (color code 2412). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 19. | Glazing Color: White (color code 2447). | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Size: Rough openings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Models: As scheduled or indicated on Drawings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Model 2052: 14.5 by 46.5 inches (368 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Model 2076: 14.5 by 70.5 inches (368 by 1791 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Model 2828: 22.5 by 22.5 inches (572 by 572 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | Model 2836: 22.5 by 30.5 inches (572 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6. | Model 2840: 22.5 by 34.5 inches (572 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 7. | Model 2852: 22.5 by 46.5 inches (572 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 8. | Model 3636: 30.5 by 30.5 inches (775 by 775 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 9. | Model 3652: 30.5 by 46.5 inches (775 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 10. | Model 4040: 34.5 by 34.5 inches (876 by 876 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 11. | Model 2868: 22.5 by 62.5 inches (572 by 1588 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 12. | Model 2876: 22.5 by 70.5 inches (572 by 1791 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 13. | Model 3668: 30.5 by 62.5 inches (775 by 1588 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 14. | Model 3676: 30.5 by 70.5 inches (775 by 1791 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 15. | Model 4052: 34.5 by 46.5 inches (876 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 16. | Model 4242: 36.5 by 36.5 inches (927 by 927 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 17. | Model 5252: 46.5 by 46.5 inches (1181 by 1181 mm). | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2.8 | GLASS COATINGS SCHEDULE | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | LoE3 Insulated Glazing Units: 5/8 inch (16 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 2 Surface: LoE-366. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 64 percent. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Solar Heat Gain Coefficient: 0.28. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.32 | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.82 | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Insulated Glazing Units: 5/8 inch (16 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 2 Surface: LoE3 - 366 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 64 percent. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Solar Heat Gain Coefficient: 0.28 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.32. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.82 | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | LoE3 - i81 Insulated Glazing Units: 5/8 inch (16 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 2 Surface: LoE3-366. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Coating on No. 4 Surface: LoE-i81: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 58 percent. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Solar Heat Gain Coefficient: 0.25. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.26 | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.48 | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | LoE3 - Triple Insulated Glazing Units: 1 1/8 inch (28 mm) overall thickness, triple glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 2 Surface: LoE3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Coating on No. 5 Surface: LoE3. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: .461 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | Solar Heat Gain Coefficient: 0.28. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon. | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.16. | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 0.93 | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | LoE3 - Bronze Insulated Glazing Units: 5/8 inch (16 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 2 Surface: LoE3 Bronze. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 0.448 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Solar Heat Gain Coefficient: 0.269. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.315 | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.79 | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | LoE3 - Solar Reflective Bronze Insulated Glazing Units: 5/8 inch (16 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Coating on No. 3 Surface: LoE3 - 366. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 0.174 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Solar Heat Gain Coefficient: 0.253 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.32 | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.82 | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Heat Mirror 44 Insulated Glazing Units: 1 1/8 inch (28 mm) overall thickness, double glazed. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Visible Light: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Transparency: 0.384 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Solar Heat Gain Coefficient: 0.249 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | U-Factor: | |||||||||||||||||||||||||||||||||||||||||||||||||
| a. | Gas: Argon/ Argon | |||||||||||||||||||||||||||||||||||||||||||||||||
| b. | IP: 0.238 | |||||||||||||||||||||||||||||||||||||||||||||||||
| c. | SI: 1.35 | |||||||||||||||||||||||||||||||||||||||||||||||||
| PART 3 | EXECUTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.1 | EXAMINATION AND PREPARATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Prepare openings and substrates using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Do not proceed with installation until openings and substrates have been prepared using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Dissimilar Material Protection: | |||||||||||||||||||||||||||||||||||||||||||||||||
| 1. | Where aluminum will contact dissimilar metals, protect against galvanic action by painting contact surfaces with primer or by applying sealant or tape recommended by manufacturer for this purpose. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 2. | Where aluminum will contact concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3. | Where aluminum will contact pressure-treated wood, separate dissimilar materials by methods recommended by manufacturer. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.2 | INSTALLATION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Install in accordance with manufacturer's instructions. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Coordinate with installation of roof deck and other substrates to receive skylight units | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Provide thermal isolation when components penetrate or disrupt building insulation. Pack fibrous insulation in rough opening to maintain continuity of thermal barriers. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Coordinate with installation of vapor barriers, roof insulation, roofing, and flashing as required to assure that each element of the work performs properly and that combined elements are waterproof and weathertight. | |||||||||||||||||||||||||||||||||||||||||||||||||
| E. | Align skylights level, free of warp or twist, maintain dimensional tolerances. | |||||||||||||||||||||||||||||||||||||||||||||||||
| F. | Anchor units securely to supporting substrates, adequate to withstand lateral and thermal stresses as well as inward and outward loading pressures. | |||||||||||||||||||||||||||||||||||||||||||||||||
| G. | Counterflashing: Where counter flashing is required as component of the skylight, install to provide an adequate waterproof overlap with roofing or roof flashing. Seal with thick bead of mastic sealant, except where overlap is indicated to be left open for ventilation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| H. | Install manufacturer's engineered perimeter flashing in accordance with manufacturer's installation instructions to achieve weather tight installation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.3 | CLEANING AND PROTECTION | |||||||||||||||||||||||||||||||||||||||||||||||||
| A. | Protect installed products until completion of project. | |||||||||||||||||||||||||||||||||||||||||||||||||
| B. | Remove labels and protective material from surfaces. | |||||||||||||||||||||||||||||||||||||||||||||||||
| C. | Clean exposed metal and plastic surfaces according to manufacturer's instructions. Touch up damaged metal coatings. | |||||||||||||||||||||||||||||||||||||||||||||||||
| D. | Clean and polish plastic skylight units, inside and out prior to date of Substantial Completion. | |||||||||||||||||||||||||||||||||||||||||||||||||