Manufacturing partner

Membrane Roofing CAD Drawings

Free Membrane Roofing Architectural CAD drawings and blocks for download in dwg or pdf formats for use with AutoCAD and other 2D and 3D design software.

By downloading and using any ARCAT CAD drawing content you agree to the following license agreement.
Summary: The CSI section 075000, titled 'Membrane Roofing', pertains to roofing systems that utilize various types of membranes to provide a watertight seal for buildings. This section includes material specifications, installation methods, and performance criteria essential for designing and constructing membrane roofing systems. CAD files associated with this section provide detailed technical drawings that assist architects, engineers, and construction professionals in visualizing and accurately implementing membrane roofing solutions.

Membrane Roofing - Fleeceback

Carlisle SynTec Systems

FB-1B.1 - Coated Drip Edge Fascia - TPO, PVC or KEE HP

FB-1C.1 - Metal Bar Edge Termination

FB-1D.1 - SecurEdge 200

FB-1E.1 - SecurEdge 300

FB-1F.1 - SecurEdge 2000 & 3000

FB-2A - EPDM Membrane Splices - Projects with 10, 15, & 20 Year Warranties

FB-2A.1 - EPDM Membrane Splices - Projects with 145mil Membrane or 25/30 Year Warranties

FB-2B.1 - Thermoplastic Membrane Splices

FB-3A.1 - Deck-to-Deck Expansion Joint

FB-3B.1 - Deck-to-Wall Expansion Joint

FB-6A.1 - Roof Drain with Continuous Membrane

FB-6B.1 - Roof Drain with Separate Target Splice

FB-8A.1 - Pre-Molded Pipe Seals

FB-8B - Field Fabricated Pipe Flashing

FB-9 - Membrane Terminations (PAGE 1 OF 2)

FB-9 - Membrane Terminations (PAGE 2 OF 2)

FB-12A.1A - Parapet/Curb with Separate Membrane - Full Coverage

FB-12A.1B - Parapet/Curb with Separate Membrane - Bead Applied

FB-12B.1A - Parapet/Curb with Continuous Membrane - Full Coverage

FB-12B.1B - Parapet/Curb with Continuous Membrane - Bead Applied

FB-12C - Parapet/Curb with Water Based Adhesive

FB-15A.1 - EPDM Pressure Sensitive Inside Corner

FB-15B.1 - EPDM Pressure Sensitive Outside Corner

FB-15C.1 - Thermoplastic Pre-Molded Inside Corner

FB-15D.1 - Thermoplastic Pre-Molded Outside Corner

FB-16A.1 - EPDM Pressure Sensitive Pourable Sealer Pocket

FB-16B.1 - Thermoplastic Molded Sealant Pocket

FB-18A.1 - Through-Wall Scupper with Pressure Sensitive EPDM Flashing

FB-18B.1 - Through-Wall Scupper with SecurWeld or Sure-Flex Metal

FB-25.1 - Simulation of Metal Roof in Thermoplastic Membranes

FB-27 - Fleeceback Membrane Attachment Using Bead Adhesive

Thermoplastic Membrane - VersiFleece

Versico Roofing Systems

VF-1.1 - VersiTrim Drip Edge Fascia

VF-1.2A - VersiTrim Heat Weldable Drip Edge

VF-1.3A - Metal Bar Edge Termination

VF-1.4A - VersiTrim 200

VF-1.5A - VersiTrim 300

VF-1.6A - VersiTrim 2000 & 3000

VF-2.2A - Thermoplastic Membrane Splices

VF-3.1A - Deck-to-Deck Expansion Joint

VF-3.2A - Deck-to-Wall Expansion Detail

VF-6.1A - Roof Drain with Continuous Membrane

VF-6.2A - Roof Drain with Separate Target Splice

VF-8.1A - Pre-Molded Pipe Seal

VF-8.2 - Field Fabricated Pipe Flashing

VF-9.0 - Membrane Terminations (PAGE 1 OF 2)

VF-9.0 - Membrane Terminations (PAGE 2 OF 2)

VF-12.3 - Parapet/Curb with Water Based Adhesive

VF-12A.1A - Parapet/Curb with Separate Membrane - Full Coverage

VF-12A.1B- Parapet/Curb with Separate Membrane - Bead Applied

VF-12B.2A- Parapet/Curb with Continuous Membrane - Full Coverage

VF-12B.2B- Parapet/Curb with Continuous Membrane - Bead Applied

VF-15.3A - Thermoplastic Pre-Molded Inside Corner

VF-15.4A - Thermoplastic Pre-Molded Outside Corner

VF-16.2A - Thermoplastic Molded Sealant Pocket

VF-18.2A - Through-Wall Scupper with Thermoplastic Coated Metal

VF-25.1A - Simulation of Metal Roof in Thermoplastic Membranes

VF-27 - VersiFleece Membrane Attachment Using Bead Adhesive

What is the Membrane Roofing CSI section and why are these CAD files important?

Membrane Roofing, categorized under CSI section 075000, is a crucial component in modern building envelopes, particularly valued for its water-resistant properties and durability. This section typically includes various types of membranes, such as thermoplastic, thermoset, and modified bitumen, each offering unique benefits suited to different applications and environmental conditions. CAD files in this context are indispensable tools that offer detailed drawings and layouts of membrane roofing systems. These drawings include precise dimensions, layer compositions, and connection details, enabling architects and engineers to integrate these systems seamlessly into building designs. The CAD files serve as a visual aid that complements the written specifications and performance requirements found in this section, ensuring that the design intent is clearly communicated to all stakeholders. Furthermore, CAD drawings provide critical insights into the installation process, illustrating how various components interact and fit together. This visualization helps construction teams understand complex roofing configurations, ensuring that the installation adheres to both the manufacturer's guidelines and industry standards. Overall, CAD files in the context of membrane roofing are vital for achieving a high-quality, reliable, and efficient roofing system.

Frequently Asked Questions

What is the importance of CAD files in the Membrane Roofing section?

CAD files provide detailed design drawings that are essential for visualizing and planning membrane roofing installations. They help ensure accurate dimensions and facilitate collaboration between architects, engineers, and contractors.

How do CAD drawings assist in the installation of membrane roofing?

CAD drawings offer precise layout plans for the installation, including details such as roof slope, drainage, and material joints, which help in executing the project accurately and efficiently.

Can CAD files for membrane roofing be customized for specific project requirements?

Yes, CAD files can be customized to accommodate specific project needs, such as unique roof shapes, penetrations, and other specific architectural features, ensuring the design meets the project’s unique requirements.

Why should AEC professionals use CAD files over traditional 2D drawings for membrane roofing projects?

CAD files provide enhanced accuracy, ease of modification, and a higher level of detail. They allow for easy updates and revisions, which are crucial for complex roofing systems, compared to traditional 2D drawings.

How do CAD files improve collaboration in membrane roofing projects?

CAD files enable seamless sharing and integration of design information among project stakeholders, enhancing communication and coordination, which is vital for the successful completion of membrane roofing projects.